PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Volatile Organic Compounds”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11Linked to original sources

Volatile organic compound concentrations and emission rates in new manufactured and site-built houses.

Concentrations of 54 volatile organic compounds (VOCs) and ventilation rates were measured in four new manufactured houses over 2-9.5 months following installation and in seven new site-built houses 1-2 months after completion. The houses were in four projects located in hot-humid and mixed-humid climates. They were finished and operational, but unoccupied. Ventilation rates ranged from 0.14-0.78 h-1. Several of the site-built houses had ventilation rates below the ASHRAE recommended value. In both manufactured and site-built houses, the predominant airborne compounds were alpha-pinene, formaldehyde, hexanal, and acetic acid. Formaldehyde concentrations were below or near 50 ppb with a geometric mean value for all houses of 40 ppb. Similarities in the types of VOCs and in VOC concentrations indicated that indoor air quality in the houses was impacted by the same or similar sources. Major identified sources included plywood flooring, latex paint and sheet vinyl flooring. One site-built house was operated at ventilation rates of 0.14 and 0.32 h-1. VOC emission rates calculated at the two conditions agreed within +/- 10% for the most volatile compounds. Generally, the ratios of emission rates at the low and high ventilation rates decreased with decreasing compound volatility. Changes in VOC emission rates in the manufactured houses over 2-9.5 months after installation varied by compound. Only several compounds showed a consistent decrease in emission rate over this period.

Air Pollution, Indoor↗

Ambient air concentrations, source profiles, and source apportionment of 71 different C2-C10 volatile organic compounds in urban and residential areas of Finland.

Ambient air concentrations and source contributions of 71 volatile organic compounds (VOCs) including C2-C10 nonmethane hydrocarbons, halogenated hydrocarbons, and carbonyls were studied at urban and residential sites in Finland. On the basis of the emission profile and concentration measurements, the contributions of different sources were estimated using a chemical mass balance (CMB) receptor model. It was shown that it is possible to apply CMB in the case of a large number of different compounds with different properties. However, the performance of the model varies significantly for the different compounds. According to the CMB analysis, major sources for these VOCs at the urban site were traffic and distant sources. At the residential site, the contribution due to traffic was minor while distant sources, liquid gasoline, and wood combustion made higher contributions. However, different compound groups or compounds were found to have totally different sources. It was also shown that a biogenic compound, isoprene, also has significant anthropogenic sources and that at some locations wood combustion can be an important source for some VOCs usually considered as traffic-related compounds (e.g., benzene).

Air Pollutants↗

Characterization of microbial and chemical composition of shuttle wet waste with permanent gas and volatile organic compound analyses.

Solid-waste treatment in space for Advanced Life Support, ALS, applications requires that the material can be safely processed and stored in a confined environment. Many solid-wastes are not stable because they are wet (40-90% moisture) and contain levels of soluble organic compounds that can contribute to the growth of undesirable microorganisms with concomitant production of noxious odors. In the absence of integrated Advanced Life Support systems on orbit, permanent gas, trace volatile organic and microbiological analyses were performed on crew refuse returned from the volume F "wet" trash of three consecutive Shuttle missions (STS-105, 109, and 110). These analyses were designed to characterize the short-term biological stability of the material and assess potential crew risks resulting from microbial decay processes during storage. Waste samples were collected post-orbiter landing and sorted into packaging material, food waste, toilet waste, and bulk liquid fractions deposited during flight in the volume F container. Aerobic and anaerobic microbial loads were determined in each fraction by cultivation on R2A and by acridine orange direct count (AODC). Dry and ash weights were performed to determine both water and organic content of the materials. Experiments to determine the aerobic and anaerobic biostability of refuse stored for varying periods of time were performed by on-line monitoring of CO2 and laboratory analysis for production of hydrogen sulfide and methane. Volatile organic compounds and permanent gases were analyzed using EPA Method TO15 by USEPA et al. [EPA Method TO15, The Determination of Volatile Organic Compounds (VOCs) in Ambient Air using SUMMA, Passivated Canister Sampling and Gas Chromatographic Analysis,1999] with gas chromatography/mass spectrometry and by gas chromatography with selective detectors. These baseline measures of waste stream content, labile organics, and microbial load in the volume F Shuttle trash provide data for waste subsystem analysis and atmospheric management within the ALS Project.

Aerobiosis↗

Characterization of emissions of volatile organic compounds from interior alkyd paint.

Alkyd paint continues to be used indoors for application to wood trim, cabinet surfaces, and some kitchen and bathroom walls. Alkyd paint may represent a significant source of volatile organic compounds (VOCs) indoors because of the frequency of use and amount of surface painted. The U.S. Environmental Protection Agency (EPA) is conducting research to characterize VOC emissions from paint and to develop source emission models that can be used for exposure assessment and risk management. The technical approach for this research involves both analysis of the liquid paint to identify and quantify the VOC contents and dynamic small chamber emissions tests to characterize the VOC emissions after application. The predominant constituents of the primer and two alkyd paints selected for testing were straight-chain alkanes (C9-C12); C8-C9 aromatics were minor constituents. Branched chain alkanes were the predominant VOCs in a third paint. A series of tests were performed to evaluate factors that may affect emissions following application of the coatings. The type of substrate (glass, wallboard, or pine board) did not have a substantial impact on the emissions with respect to peak concentrations, the emissions profile, or the amount of VOC mass emitted from the paint. Peak concentrations of total volatile organic compounds (TVOCs) as high as 10,000 mg/m3 were measured during small chamber emissions tests at 0.5 air exchanges per hour (ACH). Over 90% of the VOCs were emitted from the primer and paints during the first 10 hr following application. Emissions were similar from paint applied to bare pine board, a primed board, or a board previously painted with the same paint. The impact of other variable, including film thickness, air velocity at the surface, and air-exchange rate (AER) were consistent with theoretical predictions for gas-phase, mass transfer-controlled emissions. In addition to the alkanes and aromatics, aldehydes were detected in the emissions during paint drying. Hexanal, the predominant aldehyde in the emissions, was not detected in the liquid paint and was apparently an oxidation product formed during drying. This paper summarizes the results of the product analyses and a series of small chamber emissions tests. It also describes the use of a mass balance approach to evaluate the impact of test variables and to assess the quality of the emissions data.

Air Pollutants, Occupational↗

Concentrations of volatile organic compounds in the passenger side and the back seat of automobiles.

The in-vehicle volatile organic compound (VOC) concentrations during commutes have previously been measured in only one single interior sampling location, considering a sample collected in the single interior location as representative of overall VOC concentrations within an automobile. The present study evaluated if the potential differences in VOC concentrations occur in the automobiles' interior during idling and commuting under different driving conditions associated with the use of air cleaning devices (ACDs) and interior fan. The experiments were conducted under the low ventilation condition with the windows and the vent closed and the fan off. The difference of VOC concentrations between passenger side and back seat during idling was small. The variability of VOC concentrations with location inside automobiles while commuting was not significant at p < 0.05, regardless of the use of ACDs and/or the interior fan, while inter-vehicle variability was significant at p < 0.05. In addition, currently available ACDs equipped with activated carbon filters in Korea were ineffective at removing VOCs from the interior of automobiles. The concentrations of the two lightest ones of the target compounds, benzene and toluene, were significantly higher inside two vehicles than in the roadway air at p < 0.05, while the in-vehicle and roadway concentrations of the other target compounds did not differ significantly at p < 0.05 for both vehicles. The concentrations of all target VOCs, except benzene, were significantly higher (p < 0.05) in the interior of older car than of newer car. Median in-vehicle concentrations of benzene, toluene, ethylbenzene, p-xylene, m-xylene, and o-xylene were 38.3, 107, 9.2, 7.8, 16.9, and 10.7 micrograms/m3, respectively.

Air Pollution, Indoor↗

Volatile organic compounds from arctic bacteria of the Cytophaga-Flavobacterium-Bacteroides group: a retrobiosynthetic approach in chemotaxonomic investigations.

Volatile organic compounds emitted by different marine arctic strains of the Cytophaga-Flavobacterium-Bacteroides group were investigated by using a modified closed-loop stripping apparatus (CLSA). Seven of nine strains emitted volatiles, dominated by methyl ketones, in specific patterns. The methyl ketones were aliphatic saturated, or unsaturated, and comprised 12 to 18 C-atoms, sometimes with terminal Me branches. They were identified by GC/MS, retention-index calculations, derivatization with dimethyl disulfide for C=C bond location, and GC/FTIR to elucidate their uniform (Z)-configuration. The proposed structures of all methyl ketones were subsequently confirmed by synthesis, while the absolute configuration of chiral volatiles was elucidated by stereoselective synthesis. From retrobiosynthetic considerations, it was found that strain ARK10267 uses mainly valine, and strain ARK10063 mainly isoleucine for formation of starters for the ketone biosynthesis, which is correlated to fatty acid biosynthesis. Four strains (ARK10223, ARK10044, ARK10141, and ARK10146) use leucine. These separations are supported by phylogenetic affiliations based on 16S rRNA. Strain ARK10255b, in the course of this study found to be not a member of the Cytophaga-Flavobacterium-Bacteroides phylum, did not emit aliphatic ketones of medium chain length, but methionine-derived 4-(methylsulfanyl)butan-2-one and corresponding 4-(methylsulfanyl)butan-2-ol. Most of the compounds described have not been reported previously from nature.

Arctic Regions↗

On the cytotoxicity of some microbial volatile organic compounds as studied in the human lung cell line A549.

The cytotoxicity of 13 microbial volatile organic compounds (MVOC) was studied using a human lung carcinoma epithelial cell line A549 in a colony formation assay and two colorimetric assays: the microculture tetrazolium assay (MTT assay) and the cellular protein assay (methylene blue-MB assay). For comparison, two known cytotoxic substances: the non-volatile mycotoxin gliotoxin and the mono-functional alkylating agent methyl methanesulfonate (MMS) were studied. Concentration-response curves for each agent were established and the IC50 value (concentration resulting in 50% inhibition of colony growth or absorbance) was estimated. There are differences in toxicity levels between the MVOC tested and gliotoxin and MMS. The most toxic MVOC was 1-decanol which was as effective as MMS in all test systems. 1-decanol was about 10-fold more toxic than the other MVOC. All MVOC tested were more than 1000-fold less toxic than gliotoxin.

Bacteria↗

Silicon microfabricated column with microfabricated differential mobility spectrometer for GC analysis of volatile organic compounds.

A 3.0-m-long, 150-microm-wide, 240-microm-deep channel etched in a 3.2-cm-square silicon chip, covered with a Pyrex wafer, and coated with a dimethyl polysiloxane stationary phase is used for the GC separation of volatile organic compounds. The column, which generates approximately 5500 theoretical plates, is temperature-programmed in a conventional convection oven. The column is connected through a heated transfer line to a microfabricated differential mobility spectrometer. The spectrometer incorporates a 63Ni source for atmospheric-pressure chemical ionization of the analytes. Nitrogen or air transport gas (flow 300 cm(3)/min) drives the analyte ions through the cell. The spectrometer operates with an asymmetric radio frequency (RF) electric field between a pair of electrodes in the detector cell. During each radio frequency cycle, the ion mobility alternates between a high-field and a low-field value (differential mobility). Ions oscillate between the electrodes, and only ions with an appropriate differential mobility reach a pair of biased collectors at the downstream end of the cell. A compensation voltage applied to one of the RF electrodes is scanned to allow ions with different differential mobilities to pass through the cell without being annihilated at the RF electrodes. A unique feature of the device is that both positive and negative ions are detected from a single experiment. The combined microfabricated column and detector is evaluated for the analysis of volatile organic compounds with a variety of functionalities.

Chromatography, Gas↗

Airway symptoms among house painters in relation to exposure to volatile organic compounds (VOCS)--a longitudinal study.

The increased use of water-based paint (WBP) for indoor application during the last decade has drastically changed the exposure conditions for Swedish house painters. WBP has a lower emission of volatile organic compounds (VOCs) than solvent-based paint (SBP), but contains more reactive compounds, such as biocides, glycol ethers, and other high molecular solvents. The aim of this study was to compare the incidence of airway symptoms and self-reported asthma in house painters with a different degree of use of WBP and SBP. The incidence of seven general airway symptoms, and three work-related symptoms, was analysed by means of a self-administered questionnaire, in a cohort of 207 house painters followed from 1989 to 1992. Different airway symptoms were compared with clinical information obtained by a methacholine challenge test and dynamic spirometry in a selected subgroup of 44 painters. Information on the degree of use of SBP and WBP was used to estimate the total exposure to volatile organic compounds (TVOC) for each individual. In total, 175 men in the cohort worked as painters during the study period. No increase of asthma or respiratory symptoms was observed among those 50 painters with a pure exposure to WBP (estimated TVOC 1-3 mg m-3). Most painters (N = 125) had a mixed exposure to SBP and WBP, the main source of the TVOC being the limited use of SBP. WBP was perceived as less irritative than SBP, but complaints on airway irritation from WBP increased during the study period. The most pronounced increase of airway irritation in relation to both SBP and WBP, was observed among those 35 painters with the highest solvent exposure (estimated TVOC 100-380 mg m-3). An increase of respiratory symptom index and shortness of breath, in relation to estimated TVOC exposure was also observed. Selection effects were detected. Painters leaving their job during the study period had more non-specific hyper-reactivity symptoms, and more airway irritation from WBP, as compared to painters remaining at their occupation. Our study indicates that VOC emissions from SBPs may contribute to the development of respiratory symptoms and airway irritation. We found no increase of respiratory symptoms among painters exposed only to WBPs. There were, however, indications that VOC exposure from WBPs may cause airway irritation in some subjects. Because of selection effects, cross-sectional studies on respiratory symptoms in relation to occupational exposure to paint emissions may be inconclusive.

Adult↗

Public bus and taxicab drivers' work-time exposure to aromatic volatile organic compounds.

Information on the work-time exposure of public bus and taxicab drivers to volatile organic compounds (VOCs) may be a critical factor in exploring the association between occupational exposure and health effects. Accordingly, this study evaluated the work-time VOC exposure of public bus and taxicab drivers by measurement of six selected aromatic VOC concentrations in the personal air of public bus and taxicab drivers during winter and summer. Two groups of five public bus drivers (smokers and nonsmokers) and two groups of five taxicab drivers (smokers and nonsmokers) were recruited for the study. The taxicab drivers were found to be exposed to higher aromatic compound levels than the bus drivers during their daily work time. The personal exposure of the bus and taxicab drivers was influenced by whether or not they smoked plus the season. It was also established that the potential exposure of bus drivers to aromatic VOCs did not exceed that of an unemployed reference group, whereas the potential exposure of taxicab drivers did. Meanwhile, based on comparison of the calculated in-vehicle concentrations with those from a previous study, the VOC levels inside public buses and taxicabs were found to be lower than those inside automobiles.

Adult↗

Exposure to airborne microorganisms and volatile organic compounds in different types of waste handling.

Occupational exposure of workers to airborne microorganisms and volatile organic compounds (VOC) in different types of waste treatment situations was examined during summer time. Microorganisms were collected as stationary samples using a six-stage Andersen impactor, while for VOCs both personal and stationary sampling was conducted. The exposure at the waste handling facility was considerably greater than at landfill sites or in waste collection. The concentrations of viable fungi were maximally 10(5) cfu/m3, and the concentrations of both total culturable bacteria and Gram-negative bacteria exceeded the proposed occupational exposure limit values (OELV), being 10(4) and 10(3) cfu/m3, respectively. Exposure to VOCs in the waste handling facility was three times higher than at the landfill sites, being at highest 3000 microg/m3, considered to be the limit for discomfort. The use of personal protective equipment at work, thorough hand washing and changing clothes after the work shift are strongly recommended in the waste handling facility and the landfill sites.

Air Microbiology↗

Odor and volatile organic compound treatment by biotrickling filters: pilot-scale studies at hyperion treatment plant.

A pilot-scale biotrickling filter was installed at the Hyperion Treatment Plant in Los Angeles, California, to study hydrogen sulfide (odor) and volatile organic compound (VOC) removal from headworks waste air. The performance of the reactor was continuously monitored during a 10-month period. At an average empty bed gas residence time of 24 seconds, 10 to 50 ppm of hydrogen sulfide was consistently removed at greater than 98% efficiency, corresponding to an average volumetric elimination capacity of 5.2 g/m3 x h. Concentration profiles over the height of the reactor indicated nearly complete removal in the first section of the reactor, suggesting that elimination capacities up to 30 g/m3 x h could be obtained. The odor reduction (as dilution to threshold) was 98%, which correlated with the efficiency of removal of hydrogen sulfide as the primary pollutant. Volatile organic compounds were present at concentrations up to 225 ppb. Moderate but significant removal of toluene and benzene was observed when the biotrickling filter was operated with pH control to neutralize sulfuric acid production from hydrogen sulfide oxidation. Xylenes and chlorinated VOCs were not removed regardless of experimental conditions in the reactor. The results led to the conclusion that VOC removal is the limiting process in biotrickling filters for the simultaneous removal of hydrogen sulfide and VOCs at publicly owned treatment works.

Bioreactors↗

[Study on monitoring index of individual exposure dose of volatile organic compounds in environment].

In order to study the monitoring index of individual exposure dose of volatile organic compounds (VOCs) in environment, the thermal desorption capillary gas chromatographic (TD-GC) analysis was used to examine the VOCs level in air and the expired breath of female workers. Headspace solid phase micro-extraction gas chromatography (SPME-GC) was applied to determine the blood concentration of VOCs in female workers. The results from epidemiological study showed clearly that concentration of 10 subtypes of VOCs in blood, environmental air and expired breath from exposure group were higher than those from control group. The findings from the study suggested that the blood concentration of VOCs was sensitive and specific and this index might be one of good indexes in assessment of individual exposure dose of VOCs.

Adult↗

Determination of microbial volatile organic compounds adsorbed on house dust particles and gypsum board using SPME/GC-MS.

UNLABELLED: Adsorption of microbial volatile organic compounds (MVOCs) on house dust was analyzed by performing solid phase microextraction (SPME) in combination with gas chromatography-mass spectrometry (GC-MS). Settled dust samples were exposed to five selected MVOCs and to cultures of the molds Stachybotrus chartarum, Aspergillus versicolor, and Chaetomium globosum. Considerable desorption of the MVOCs adsorbed on the dust occurred spontaneously within a few hours at room temperature and within several days or weeks after storage at -20 degrees or -80 degrees C. Similar results were found for a sample of a gypsum board cultivated with A. versicolor. SPME/GC-MS analysis performed immediately after sampling revealed several of the studied MVOCs on gypsum board and settled dust collected in a house garage with visible mold growth. MVOCs adsorbed on respirable particles of house dust can be inhaled and reach deep into the respiratory system, which may partly explain health effects that have been found to be associated with the presence of low concentrations of MVOCs in air. Particle-bound MVOCs can easily be detected by SPME/GC-MS analysis, thus this technique may prove to be very useful in indoor air research for identifying factors that affect human health. PRACTICAL IMPLICATIONS: We used SPME combined with GC-MS to study the adsorption and desorption of MVOCs on house dust particles that had been exposed to cultivated molds and molds in a damp building. Adsorbed MVOCs desorb spontaneously but this process can be slowed down by storing samples at -20 degrees or -80 degrees C. This opens up a possibility to apply SPME/GC-MS to reveal mold growth in buildings and to determine MVOCs in respirable dust particles that may reach deep in the respiratory system and lead to respiratory illnesses.

Air Microbiology↗

Building related illness involving formaldehyde and other volatile organic compounds.

A large percentage of the occupants in a 96,000 ft2 office building were suffering multiple adverse health symptoms continuing and/or reoccurring for over 4 years. The symptoms were believed to be the result of building related illness. Detailed indoor air quality and product emission studies realed the presence of formaldehyde and volatile organic compounds contamination primarily resulting from furniture constructed of pressed wood products (formaldehyde source) and a chemical deodorizer (volatile organic compound source).

Deodorants↗

A comparison study of sampling and analyzing volatile organic compounds in air in Kuwait by using Tedlar bags/canisters and GC-MS with a cryogenic trap.

Kuwait experiences desert climatic weather. Due to the extreme hot and dry conditions in this country, some analytical phenomena have been discovered. Therefore, a systematic study of sampling and analyzing volatile organic compounds in air by using GC-MS with a cryogenic trap is reported in this paper. This study included comparisons of using different sample containers such as Tedlar bags and SUMMA canisters, and different cryogenic freezing-out air volumes in the trap. Calibration curves for different compounds and improvement of replicated analysis results were also reported here. The study found that using different sample containers produced different results. Analysis of ambient air samples collected in Tedlar bags obtained several volatile organic compounds with large concentrations compared to using SUMMA canisters. Therefore, to choose a sample container properly is a key element for successfully completing a project. Because GC-MS with a cryogenic trap often generates replicated results with poor agreement, an internal standard added to gas standards and air samples by using a gas syringe was tested. The study results proved that it helped to improve the replicated results.

Air Pollutants↗

Ambient volatile organic compound (VOC) concentrations around a petrochemical complex and a petroleum refinery.

Air samples were collected between September 2000 and September 2001 in Izmir, Turkey at three sampling sites located around a petrochemical complex and an oil refinery to measure ambient volatile organic compound (VOC) concentrations. VOC concentrations were 4-20-fold higher than those measured at a suburban site in Izmir, Turkey. Ethylene dichloride, a leaded gasoline additive used in petroleum refining and an intermediate product of the vinyl chloride process in the petrochemical complex, was the most abundant volatile organic compound, followed by ethyl alcohol and acetone. Evaluations based on wind direction clearly indicated that ambient VOC concentrations measured were affected by the refinery and petrochemical complex emissions. VOC concentrations showed seasonal variations at all sampling sites. Concentrations were highest in summer, followed by autumn, probably due to increased evaporation of VOCs from fugitive sources as a result of higher temperatures. VOC concentrations generally increased with temperature and wind speed. Temperature and wind speed together explained 1-60% of the variability in VOC concentrations. The variability in ambient VOC concentrations that could not be explained by temperature and wind speed can be attributed to the effect of other factors (i.e. wind direction, other VOC sources).

Journal Article↗

Removing the smoking confounder from blood volatile organic compounds measurements.

Because smoking is a major contributor to the internal dose levels of many volatile organic compounds (VOCs), it is difficult to assess other VOC exposures among smokers. Purge and trap/gas chromatography/isotope-dilution mass spectrometry was used to determine the internal dose of VOCs of smokers and nonsmokers. Median whole blood concentrations of benzene, styrene, and toluene were shown to be approximately two times higher among smokers than among nonsmokers. In addition, smoking elevated the blood levels of ethylbenzene, m-/p-xylene, and o-xylene when the log-transformed data were compared. Smoking also led to greatly increased levels of 2,5-dimethylfuran. These results indicate that blood levels of many VOCs are highly correlated with blood levels of 2,5-dimethylfuran and that this effect is primarily a result of smoking. The smoking confounder to blood levels of VOCs can be removed by including the concentration of blood 2,5-dimethylfuran concentration when evaluating results from a health and exposure evaluation. Determining the blood 2,5-dimethylfuran concentration appears to be an effective means of correcting the confounding influence of smoking and supplies a way of determining lower-level exposures that previously could not have been distinguished from the effects of smoking.

Air Pollutants↗