Development of a perchlorate reductase-based biosensor for real time analysis of perchlorate in water.

Perchlorate (ClO4-) contamination of ground water is a widespread problem in the U.S., which can adversely affect human health and wildlife. Current methods for detecting and quantifying ClO4- in water are time consuming, expensive and sometimes subject to complex procedures. This study reports the construction of a ClO4- reductase-based biosensor for rapid determination of ClO4- in water. Using a 3 mm GCE (glass carbon electrode), a ClO4- sensing bio-electrode was constructed by coating an aliquot of a Dechlorosoma sp. ClO4- reductase on nafion (ion-exchange matrix) layer pre-coated on the polished surface of the GCE. The response time to ClO4- was approximately 111+/-28 s. Kinetic evaluation of the sensor response to ClO4- revealed linear increases (r2>99%) in 10 min with k values of 10.3, 24.2, 33.9 and 48.2 at 25, 50, 75 and 100 microg/L, respectively. A strong linear correlation was established between biosensor response (nA) and ion-chromatography conductivity readings (microS). Biosensor response to ClO4- was maximal at applied potential range of -0.6 to -1.0 V. ClO4- reduction was maximal in the range of 7.6 to 8.0. The ClO4- biosensor was significantly stable after repeated use (24 analyses conducted on day 1 over a 10-h period at room temperature). This study indicates great potential for the development of a portable biosensor for real time analysis of ClO4- in water.

Biosensing Techniques↗

Determination of affinities and antigenic epitopes of bovine cardiac troponin I (cTnI) with monoclonal antibodies by surface plasmon resonance biosensor.

A surface plasmon resonance (SPR) biosensor based on wavelength modulation was used for real-time detection of the interaction of three monoclonal antibodies and antigens of bovine cardiac troponin I (cTnI). In order to recognize antigenic epitopes of bovine cTnI, two experimental modes were applied. In the first experimental mode, three monoclonal antibodies were divided into three groups and three experiments were performed on biosensor surfaces prepared with protein A. In the second experimental mode, antigen was immobilized on the biosensor surface prepared by the amine-coupling method and three monoclonal antibodies were detected in turn. The results obtained by the two modes are consistent. In addition, the affinities of the monoclonal antibodies for the antigen were also determined by the association rate and the disassociation rate in real-time. These results validate the biosensor technology and illustrate how biosensors based on wavelength modulation can be used to study the interaction of monoclonal antibodies and antigens in real time.

Animals↗

A lightweight measuring device for the continuous in vivo monitoring of glucose by means of ultraslow microdialysis in combination with a miniaturised flow-through biosensor.

BACKGROUND: Tight regulation of blood glucose levels from patients suffering from diabetes mellitus can significantly reduce the complications associated with this disease. For this reason, elaborate research efforts have been devoted to the development of a glucose sensor for the continuous in vivo monitoring of glucose. Although the use of microdialysis as a sampling interface between the body and the biosensor is widely accepted, a major drawback of conventional microdialysis is the limited in vivo recovery. Here, ultraslow microdialysis is proposed in order to obtain (near) quantitative in vivo recoveries. To avoid, however, unacceptable long delay times, the need for a small and low dead volume measuring device was recognised. METHODS: A portable lightweight measuring device for continuous in vivo monitoring of glucose in subcutaneous tissue is presented. The measuring device consists of a miniaturised flow-through biosensor, connected to a microdialysis probe and a semi-vacuum pump. The biosensor is based on the amperometric detection of hydrogen peroxide after conversion of glucose by immobilised glucose oxidase. A portable potentiostat equipped with data logging is used for detection and registration. RESULTS: The device was validated for its accuracy, precision, linearity, sensitivity, selectivity and stability during ex vivo and in vivo experiments. The linearity was found to be up to 30 mmol/l with a limit of detection of 0.05 mmol/l. The precision, depending on the biosensor tested was found to be 2-4%. No contribution to the signal could be observed from several tested electroactive species. The accuracy was found to be well in accordance with the criteria set for methods of Self Monitoring of Blood Glucose for patients with diabetes mellitus. The biosensors could be used for up to 3 days in the continuous mode. In vivo monitoring of glucose in dialysate of subcutaneous sampled tissue during glucose tolerance tests in healthy volunteers demonstrated the potential of this measuring device. CONCLUSIONS: A portable lightweight measuring device is presented which can measure continuously glucose in vivo without excessive calibration steps. The performance characteristics determined justify the application of this measuring device for the in vivo monitoring of glucose in subcutaneous sampled interstitium of diabetic patients.

Biosensing Techniques↗

Evaluation of a biosensor for the measurement of lactate in whole blood.

OBJECTIVES: Evaluation of the analytical performance of a biosensor for the measurement of lactate in whole blood samples and comparison of the results of patients samples with a routinely used spectrophotometric enzymatic method. DESIGN AND METHODS: Heparinized whole blood samples of patients and aqueous control samples were used to determine precision and carry-over. For comparison of the lactate biosensor and the enzymatic method human blood samples were split and measured. RESULTS: Satisfactory within-run (n = 7) and day-to-day (n = 15) precision was found, while carry-over was minimal (<0.2%). A statistically significant relation between the lactate levels in whole blood samples (n = 31) and the corresponding plasma samples was found: y = 0.98x - 0.05 and r = 1.00. No correlation was found between the hematocrit (range 0.23-0.51) and the difference in lactate concentration between plasma and whole blood. When comparing patient results (n = 722) obtained with the spectrophotometric method and the biosensor method, the biosensor measured 13% higher lactate levels. A correction on the basis of the hematocrit minimized this difference. CONCLUSION: The combination of analytical performance, easy handling, rapid analysis, and measurement in whole blood makes the biosensor suitable for lactate STAT-analyses. Care must be given to the interpretation of the results as well as to the preanalytical aspects.

Biosensing Techniques↗

Inhibiting effects of chloroform on anaerobic microbial consortia as monitored by the Rantox biosensor.

The Rantox biosensor was designed for anaerobic wastewater treatment process control, and detects modifications of the feed based on the response of the acetoclastic methanogens contained in the sensor to periodic pulses of a concentrated organic substrate. The biosensor was tested under various operating conditions at the laboratory scale, in parallel with a digester under control fed on the same substrate. The aim was to evaluate the response of the biosensor in the presence of an incoming organic toxic compound (CHCl3). The experimental set-up, i.e. the biosensor and the digester, was connected to an automated control system developed under LabVIEW environment for data acquisition and operational sequence programming (the Rantox Virtual Instrument). Biomasses with different activities were used as inocula, and inhibition was induced by dosing chloroform according to two different procedures. The results showed good sensitivity and rapid response of the biosensor to feed intoxication. The presence of chloroform was detected by the Rantox with a rapid and visible response, and well in advance with respect to the digester.

Anaerobiosis↗

Bioprocess monitoring: an optical biosensor for rapid bioproduct analysis.

The use of an optical biosensor for rapid bioproduct analysis is described. The biosensor, which is sensitive to changes in the concentration of bioproduct at its biologically active surface, has been shown to provide concentration data within 10 s of sample addition to the device. This has been achieved through the use of linear regression analysis to extract information from the early part of the biosensor interaction profiles. The system has been used to monitor both the production and purification of antibody fragments expressed during batch fermentation of recombinant Escherichia coli. Data obtained using the biosensor have been used to provide real-time profiles describing the location of antibody fragments during bioprocessing. Biosensor data have also been compared with those obtained from ELISA, the traditional method of retrospective analyses of samples collected during bioprocessing.

Animals↗

Drug metabolism biosensors: electrochemical reactivities of cytochrome P450cam immobilised in synthetic vesicular systems.

Biosensors containing cytochrome P450cam in a didodecyldimethylammonium bromide vesicular system were prepared by cross-linking onto a glassy carbon electrode (GCE) with glutaraldehyde in the presence of bovine serum albumin. Cyclic voltammetric responses of the sensor in air-free buffer solution showed that the sensor exhibited reversible electrochemistry due to direct electron exchange between the haem Fe(3+/2+) redox system and the GCE surface. In air-saturated solution containing camphor, the biosensor gave an irreversible electrocatalytic current which is compatible with the monooxygenation of the substrate. Steady state amperometric experiments with camphor, adamantanone and fenchone were performed with a biosensor prepared by cross-linking P450cam with glutaraldehyde onto a Pt disc electrode. The sensor was characterised by fast amperometric responses, attaining steady-state in about 20 s in a cobalt sepulchrate mediated electrochemical system. The kinetic parameters of the biosensor were analysed using the electrochemical Michaelis Menten equation. The estimated apparent Michaelis-Menten constant, Km, values for the biosensors were in the range of 1.41-3.9 mM.

Animals↗

DNA based biosensors.

Compared to advances in enzyme sensors, immunosensors, and microbial biosensors, relatively little work exists on DNA based biosensors. Here we review the DNA based biosensors that rely on nucleic acid hybridization. Major types DNA biosensors--electrochemical, optical, acoustic, and piezoelectric--are introduced and compared. The specificity and response characteristics of DNA biosensors are discussed. Overall, a promising future is foreseen for the DNA based sensor technology.

Journal Article↗

Biosensor technology and surface plasmon resonance for real-time detection of HIV-1 genomic sequences amplified by polymerase chain reaction.

BACKGROUND: The recent development of biosensor technologies for biospecific interaction analysis enables the monitoring of a variety of molecular reactions in real time by surface plasmon resonance (SPR). If the ligand is a biotinylated single stranded DNA, this technology could monitor DNA-DNA hybridization. This approach could be of great interest in virology, since the hybridization step is oftenly required to confirm specificity of molecular diagnosis. OBJECTIVES: To determine whether real-time molecular diagnosis of human immunodeficiency virus type I (HIV-1) could be performed using biosensors and SPR technology. STUDY DESIGN: Specific hybridization of a biotinylated HIV-1 oligonucleotide probe immobilized on a sensor chip to single stranded DNA obtained by asymmetric polymerase-chain reaction (PCR) was determined using the BIAcore biosensor. RESULTS: Direct injection of asymmetric PCR to a sensor chip carrying an internal HIV-1 oligonucleotide probe allows detection of hybridization by SPR using biosensor technology. This enabled us to apply a real-time, one-step, non-radioactive protocol to demonstrate the specificity of amplification of HIV-1 genomic sequences by PCR. CONCLUSION: The procedure described in this study for HIV-1 detection is simple, fast (PCR and SPR analyses take 30 min), reproducible and could be proposed as an integral part of automated diagnostic systems based on the use of laboratory workstations and biosensors for DNA isolation, preparation of PCR reactions and analysis of PCR products.

Biosensing Techniques↗

Microbial biosensors.

A microbial biosensor consists of a transducer in conjunction with immobilised viable or non-viable microbial cells. Non-viable cells obtained after permeabilisation or whole cells containing periplasmic enzymes have mostly been used as an economical substitute for enzymes. Viable cells make use of the respiratory and metabolic functions of the cell, the analyte to be monitored being either a substrate or an inhibitor of these processes. Bioluminescence-based microbial biosensors have also been developed using genetically engineered microorganisms constructed by fusing the lux gene with an inducible gene promoter for toxicity and bioavailability testing. In this review, some of the recent trends in microbial biosensors with reference to the advantages and limitations are been discussed. Some of the recent applications of microbial biosensors in environmental monitoring and for use in food, fermentation and allied fields have been reviewed. Prospective future microbial biosensor designs have also been identified.

Bacteria↗

Development and optimisation of biosensors based on pH-sensitive field effect transistors and cholinesterases for sensitive detection of solanaceous glycoalkaloids.

Highly sensitive biosensors based on pH-sensitive field effect transistors and cholinesterases for detection of solanaceous glycoalkaloids have been developed, characterised and optimised. The main analytical characteristics of the biosensors developed have been studied under different conditions and an optimal experimental protocol for glycoalkaloids determination in model solution has been proposed. Using such a biosensor and an enzyme reversible inhibition effect, the total potato glycoalkaloids content can be determined within the range of 0.2-100 microM depending on the type of alkaloid, with lowest detection limits of 0.2 microM for alpha-chaconine, 0.5 microM for alpha-solanine and 1 microM for solanidine. The dynamic ranges for the compounds examined show that such biosensors are suitable for a quantitative detection of glycoalkaloids in real potato samples. High reproducibility, operational and storage stability of the biosensor developed have been shown.

Biosensing Techniques↗

A conductometric biosensor for biosecurity.

The paper describes the development of a conductometric biosensor for detecting foodborne pathogens. The biosensor consists of two components: an immunosensor that is based on electrochemical sandwich immunoassay, and a reader for signal measurement. The architecture of the immunosensor utilizes a lateral flow system that allows the liquid sample to move from one pad to another. The biosensor provides a specific, sensitive, low volume, and near real-time detection mechanism. Results are presented to highlight the performance of the biosensor for enterohemorrhagic Escherichia coli O157:H7 and Salmonella spp., which are of concern to biosecurity. The lower limit of detection is approximately 7.9 x 10(1) colony forming units per milliliter within a 10-min process. The ability to change the specificity of the antibodies will enable the biosensor to be used as a detection device for other types of foodborne pathogens.

Biosensing Techniques↗

Studies on the electrochemical performance of glucose biosensor based on ferrocene encapsulated ORMOSIL and glucose oxidase modified graphite paste electrode.

The electrochemical performance of a new glucose biosensor is reported. The glucose biosensor is developed using glucose oxidase (GOD) and ferrocene encapsulated palladium (Pd)-linked organically modified sol-gel glass (ORMOSIL) material incorporated within graphite paste electrode. The ORMOSIL material incorporated within graphite paste electrode behaves as an excellent electrocatalyst for the oxidation of enzymatically reduced GOD. The electrochemical behavior of new glucose biosensor has been examined by cyclic volammetry and amperometric measurements. The bioelectrocatalysis of ORMOSIL embedded within graphite paste as a function of storage time and varying concentration of ORMOSIL is reported. The initial amperometric response on glucose sensing is recorded to be 145 microA at 15% (w/w) concentration of the ORMOSIL which is decreased to 20 microA at 5% of the same keeping GOD concentration constant. The variation of electrochemical behavior of the ORMOSIL embedded within graphite paste as a function of time has also been studied based on cyclic voltammetry. The voltammograms showing the reversible electrochemistry of ORMOSIL encapsulated ferrocene is changed into a plateau shape as a function of time, however, the electrocatalytic behavior is still retained. The practical usability of new glucose sensor has been compared with earlier developed glucose sensor. The sensitivity, response time and linearity of the new glucose biosensor are found to be excellent over earlier reported glucose biosensor. The amperometric response, calibration curve and practical applications of new glucose sensor are reported.

Biosensing Techniques↗

Fabrication of glucose oxidase/polypyrrole biosensor by galvanostatic method in various pH aqueous solutions.

The pH effect of pyrrole electropolymerization in the presence of glucose oxidase (GODx) on the performance and characteristic of galvanostatically fabricated glucose oxidase/polypyrrole (Ppy) biosensor is reported. Preparing the GODx/Ppy biosensors in 0.1 M KCl saline solution with various pH containing 0.05 M pyrrole monomer and 0.5 mg/ml GODx at 382 microA/cm2 current density for 100 mC/cm2 film thickness, both the galvanostatic responses and characteristics of these resulted biosensors were obtained. The results revealed that the galvanostatic glucose biosensor fabricated at neutral pH condition exhibited much higher sensitivity than those fabricated at lower or higher pH conditions, and had a good linearity form zero to 10 mM glucose with the sensitivity of 7 nA/mM. Finally, the long-term stability and the kinetic parameters, Michaelis constant and maximum current, of this biosensor were also reported.

Biosensing Techniques↗

Biosensors for determination of total and natural antioxidant capacity of red and white wines: comparison with other spectrophotometric and fluorimetric methods.

Research was carried out to experimentally evaluate the antioxidant capacity of several red and white wines using a superoxide dismutase (SOD) biosensor recently developed by the present authors. Measurements were performed by comparing the biosensor response to increasing concentration of the superoxide radical produced in solution by the xanthine/xanthine oxidase system, both in the presence and absence of the test sample.The results were compared with those of two traditional spectrophotometric methods and of a spectrofluorimetric method described in literature.Lastly, also the polyphenol, sulfite and ascorbic acid contents of the different wine samples examined were measured using a tyrosinase biosensor, a sulfite oxidase biosensor and an ascorbate oxidase biosensor, respectively.

Antioxidants↗

Multianalyte biosensors on optical imaging bundles.

We present an optical biosensor design that expands the utility of enzyme biosensors. These biosensors are fabricated by site-selective photodeposition of analyte-sensitive polymer matrices on optical imaging fibres. These dual-analyte arrays allow for the simultaneous, independent measurement of the analyte of interest and the transducing analyte. The first integrated optical-biosensors using this design have been prepared that allow both the dependent and independent analytes to be measured simultaneously, for example penicillin and pH (Healey & Walt, 1995) or glucose and O2 (Li & Walt, 1995). Independent measurement of the transducing analyte allows penicillin or glucose to be quantitated in the presence of a concurrent pH or O2 change, respectively. Penicillin can be measured in the range 0.25-10.0 mM in the pH range 6.2-7.5. Glucose can be measured in the range 0.6-20.0 mM in the O2 range 20-100%. The utility of the sensor design was demonstrated by using the penicillin-dual-analyte biosensor to quantitate penicillin produced during a Penicillium chrysogenum fermentation.

Biosensing Techniques↗

Calibration of glucose biosensors by using pre-steady state kinetic data.

A new method for biosensor calibration and data processing, allowing the prediction of steady state parameters from the analysis of transient response curves (Rinken et al., 1996. Analytical Letters 29, 859), has been evaluated in the case of an oxygen sensor based two-substrate enzyme electrode for glucose determination. The electrochemical glucose biosensor was prepared by covering the surface of oxygen sensor with glucose oxidase (EC 1.1.3.4) immobilized in nylon mesh. This decreased the oxygen flow to the sensor in the presence of glucose and resulted in time-dependent decrease of the biosensor signal. Except the lag period of the response in the beginning of the assay, the oxygen consumption by the immobilized enzyme was described by an exponential function: [formula: see text] The parameter C, which corresponded to the steady-state output of the biosensor, was found to be the most suitable for glucose determination. The non-linear fitting for data of over 1000 independent experiments to the equation above always revealed correlation coefficients greater than 0.97. The calculation of the steady state parameter from the transient phase data makes the analysis fast and precise, especially for sensors with thick membranes, being convenient to use in the case of enzyme electrodes. The theoretical essence of the parameter C also gives valuable information for the optimal design of biosensors.

Biosensing Techniques↗

Development of renewable surface biosensors to meet industrial needs for measurement of glucose in fruit juices.

Most biosensors reported to date have been prepared, studied and used under laboratory conditions. The feasibility of a very great number of biosensors seems to be demonstrated and their characteristics, very often, established as corresponding to the demands of the modern analysis. The operational stability of the biosensors, according to authors, is almost always acceptable. The long term storage, with analytical quality conservation that is necessary to commercialise products, has rarely been studied. The stability of biosensors has to remain not only during the fabrication step or their subsequent utilisation, but also throughout the whole commercial shelf-life of the sensor, from producer to end user, through wholesaler and/or retailer. We developed the manufacturing processes, on a large scale, of renewable surface electrodes modified with enzymes such as oxidoreductases. The process consisting of several steps is described and the analytical behaviours of resulting biosensors is studied and correlated with the effects of different constraints applied during the fabrication process.

Beverages↗