PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “continuous glucose monitoring”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11Linked to original sources

The next generation: continuous glucose monitors.

These "real-time" monitors promise to change the way we chart ups and downs, by delivering readings every few minutes around the clock. But don't toss your old monitors just yet!

Blood Glucose Self-Monitoring↗

Performance of subcutaneously implanted glucose sensors for continuous monitoring.

Despite a considerable amount of research attributed to the development of an implantable glucose sensor, to date there is no clinically applicable concept for continuous glucose monitoring. Investigations to validate the subcutaneous tissue for continuous glucose sensing mostly comprised short-term implantations of glucose sensors. Most implanted glucose sensors showed a significant drift in sensitivity over the implantation period. This bioinstability was not to be expected from the in vitro performance of the sensors. In this paper, the influence of possible failure mechanisms on the poor in vivo performance of subcutaneously implanted glucose sensors is reviewed.

Animals↗

Evolution of the Artificial Pancreas: Components and Integration-CGMs, Insulin, and AP Systems.

The landmark Diabetes Control and Complications Trial (DCCT) showed that glucose control is critical to reducing the risk of diabetes-related complications. This chapter outlines a series of innovations and investigations that followed the DCCT, aimed at minimizing the risk of hypoglycemia while further improving glucose control. The chapter presents an example of innovations in wired enzyme technology that facilitated the movement from capillary glucose monitoring to continuous glucose monitoring (CGM) and ultimately, the first-factory calibrated CGM system. The next glycemic management innovation was to connect CGM data to an insulin pump containing an algorithm able to adjust insulin delivery based on the changing glucose levels and trends. The key features of automated insulin delivery (AID) systems, currently approved in the United States, are presented. The AID summary table includes type of pump, type and function of the insulin delivery algorithm, the data management system, and the indications for use. The next section explores the innovation of alternative routes of insulin delivery to move toward the goal of a fully automated insulin delivery system. The main trials in developing and implementing an implantable intraperitoneal programmable system are summarized. The last section explores if sensor input in addition to glucose levels such as continuous sensing of ketone, lactate, or insulin levels may provide valuable feedback to move us closer to a fully autonomous AID system. Much of this diabetes innovation and investigation work has been supported by the National Institute of Diabetes and Digestive and Kidney Diseases over that last 75 years.

Humans↗

Continuous monitoring of blood glucose.

Continuous blood glucose monitoring aims to: better evaluate glycaemic variations; better detect hypoglycaemia; and, ultimately, automatize insulin delivery (artificial beta cell). The sensors can be fully implantable, with the challenge of constructing durable systems to avoid repeated implantations. In-dwelling needle-like electrodes and microdialysis fibres with a pump that brings the dialysate to the glucose sensor are inserted in the subcutaneous tissue through the skin. The GlucoWatch is an almost non-invasive technique that extracts the extracellular fluid by iontophoresis. In these systems, the glucose oxidase generates the electrical signal, proportional to the glucose concentration. Non-invasive techniques aim at measuring the glucose concentration without breaching the skin, using absorption of light in the infrared spectrum. These techniques have not reached the necessary reliability for use as glycaemic alarms, and even less as artificial beta cells. Currently, glucose sensors are mainly used as glycaemic holters to help in the management of insulin therapy.

Blood Glucose↗

Progress in practical endocrinology. The Glucosensor Unitec Ulm--a portable monitor for continuous blood glucose measurement.

The Glucosensor Unitec Ulm is the first portable glucose sensor for continuous glucose monitoring in blood. The Glucosensor weighs 850 g and has a size of 15 x 19 x 7 cm. Over a 24 hr period 15-25 ml of blood are withdrawn for continuous measurement, depending on the pumping velocity. Its storing capacity for data of blood glucose readings amounts to 32 KB. With the Glucosensor "long-term glucograms" under near-normal conditions can be registered. The glucograms enable the physician to recognize the different deteriorations of glucose met- abolism eg. periods of silent hypoglycemia during the night as well as postprandial hyperglycemia. The degree of glycemic control of diabetic patients can be analyzed and the effect of blood glucose lowering therapeutics can be realistically assessed.

Blood Glucose↗

Strength and endurance training lead to different post exercise glucose profiles in diabetic participants using a continuous subcutaneous glucose monitoring system.

BACKGROUND: Although both strength training (ST) and endurance training (ET) seem to be beneficial in type 2 diabetes mellitus (T2D), little is known about post-exercise glucose profiles. The objective of the study was to report changes in blood glucose (BG) values after a 4-month ET and ST programme now that a device for continuous glucose monitoring has become available. MATERIALS AND METHODS: Fifteen participants, comprising four men age 56.5 +/- 0.9 years and 11 women age 57.4 +/- 0.9 years with T2D, were monitored with the MiniMed (Northridge, CA, USA) continuous glucose monitoring system (CGMS) for 48 h before and after 4 months of ET or ST. The ST consisted of three sets at the beginning, increasing to six sets per week at the end of the training period, including all major muscle groups and ET performed with an intensity of maximal oxygen uptake of 60% and a volume beginning at 15 min and advancing to a maximum of 30 min three times a week. RESULTS: A total of 17,549 single BG measurements pretraining (619.7 +/- 39.8) and post-training (550.3 +/- 30.1) were recorded, correlating to an average of 585 +/- 25.3 potential measurements per participant at the beginning and at the end of the study. The change in BG-value between the beginning (132 mg dL(-1)) and the end (118 mg dL(-1)) for all participants was significant (P = 0.028). The improvement in BG-value for the ST programme was significant (P = 0.02) but for the ET no significant change was measured (P = 0.48). Glycaemic control improved in the ST group and the mean BG was reduced by 15.6% (Cl 3-25%). CONCLUSION: In conclusion, the CGMS may be a useful tool in monitoring improvements in glycaemic control after different exercise programmes. Additionally, the CGMS may help to identify asymptomatic hypoglycaemia or hyperglycaemia after training programmes.

Aged↗

Evaluation of metabolic control using a continuous subcutaneous glucose monitoring system in patients with type 1 diabetes mellitus who achieved insulin independence after islet cell transplantation.

This study evaluated the Medtronic MiniMed Continuous Glucose Monitoring System (CGMS) in patients with type 1 diabetes mellitus who underwent successful islet cell transplantation (ICT). The results are compared to standardized self-monitoring (SMBG) of hyperglycemia and mean amplitude of glycemic excursions (MAGE). We studied 19 patients (mean age 40.0 +/- 6.7 years) in three groups: six patients post-ICT, seven patients awaiting ICT, and six normal volunteers (controls). Continuous glucose monitoring post-ICT showed remarkable glucose stability compared with patients awaiting ICT. The CGMS group showed modestly higher glucoses (mean 111.5 mg/dl) compared with controls (88 mg/dl). Postprandial glucoses in ICT recipients rarely exceeded 180 mg/dl and were similar to controls. There was no difference in asymptomatic hypoglycemia between control and post-ICT groups. However, a higher incidence of hypoglycemia was observed in patients awaiting ICT. HbA1c and MAGE pre- and post-ICT were 8.3 +/- 0.9% and 6 +/- 0.3% (p < 0.001) and 109 +/- 34 and 41 +/- 11 (p < 0.001), respectively. No complications were associated with CGMS. This study suggests ICT significantly improves metabolic control and rate of hypoglycemia when compared with controls and patients awaiting ICT. Similar improvement in metabolic control was observed with SMBG, HbA1c, and MAGE. Although CGMS was not demonstrated to be a superior tool for routine assessment in ICT, it is very helpful in special clinical situations.

Adult↗

Continuous subcutaneous glucose monitoring in children with type 1 diabetes.

PURPOSE: To determine whether the use of continuous subcutaneous glucose monitoring will help in detecting unrecognized nocturnal hypoglycemia and in lowering hemoglobin A1c (HbA1c) levels (without increasing the risk for severe hypoglycemia) in children with type 1 diabetes. METHODS: Eleven children with type 1 diabetes and HbA1c values consistently >8.0% were randomized either to the Continuous Glucose Monitoring System (CGMS) group or to the control group. The CGMS group used 6 3-day sensors within a 30-day period. Both groups self-monitored their blood glucose levels a minimum of 4 times daily. HbA1c levels were measured at the start, at 1-month, and after 3 months of study. RESULTS: The 5 children using the CGMS had 17 asymptomatic episodes (85%) of glucose levels below 60 mg/dL (3.25 mmol/L) and 3 symptomatic episodes (15%) during the night in the study month. The 6 control children had 4 symptomatic nocturnal low episodes during the month. After the 30-day period of wearing the CGMS, the 5 children had a significantly lower mean HbA1c value compared with their initial value (mean +/- standard error of the mean [SEM] decrease =.36% +/-.07%). The mean decrease for the controls was.2% +/-.2%. After 3 months, 4 of the 5 children who used the CGMS continued to have lower HbA1c values in comparison to their initial values (mean +/- SEM decrease = 1.04% +/-.43%). Three of the 6 control participants also had lower HbA1c values at 3 months (mean +/- SEM decrease for the group =.62% +/-.44%). No severe hypoglycemic events occurred in either the CGMS or the control groups. CONCLUSION: In this pilot trial, continuous subcutaneous glucose monitoring was helpful in detecting asymptomatic nocturnal hypoglycemia as well as in lowering HbA1c values without increasing the risk for severe hypoglycemia in children with type 1 diabetes.

Adolescent↗

Efficacy of continuous real-time blood glucose monitoring during and after prolonged high-intensity cycling exercise: spinning with a continuous glucose monitoring system.

BACKGROUND: Hypoglycemia is the most common and serious side effect of insulin therapy in type 1 diabetes (T1DM), frequently occurring both during and after vigorous exercise. Late-onset hypoglycemia (LOH) is of great concern, occurring 1-36 h after exercise, often going unnoticed during sleep. Repeated exposure to LOH causes autonomic glucose counterregulatory failure and sometimes coma and death. Continuous glucose monitoring systems have recently emerged as a potentially important tool in diabetes management, allowing individuals to track glucose levels continuously and learn how various behaviors influence glucose control. METHODS: In this pilot study, we determined the efficacy of using a real-time continuous glucose monitoring system (Guardian RT, Minimed, Northridge, CA) to detect blood glucose excursions associated with exercise and LOH (i.e., blood glucose concentration <4 mM) after exercise in individuals with T1DM. Five subjects with T1DM were monitored before, during, and after a 60 min vigorous spin class using Guardian RT (48 h in total). RESULTS: Following the exercise, three of the five subjects had LOH, while the other two experienced decreases in blood glucose concentrations to 4 mM. The Guardian RT monitor was effective in notifying all of the subjects of such glycemic excursions over the 48 h surveillance period. A strong correlation (r = 0.89, P < 0.001) was found between conventional self-monitoring of blood glucose and Guardian RT data pairs. CONCLUSION: These limited data suggest that nocturnal LOH occurs commonly following vigorous exercise and that a Guardian RT is a useful and important diagnostic tool. Further study into clinical strategies for preventing hypoglycemia associated with this common form of mixed aerobic and anaerobic exercise is urgently needed through insulin modification and carbohydrate supplementation.

Adult↗

Continuous subcutaneous glucose monitoring improved metabolic control in pediatric patients with type 1 diabetes: a controlled crossover study.

OBJECTIVE: To improve metabolic control and prevent complications, both acute and late, we need to adjust treatment on the basis of the blood glucose (BG) profile, as not even the most active BG self-monitoring gives sufficient information. DESIGN: We have used Continuous Glucose Monitoring System (CGMS; Medtronic MiniMed, Northridge, CA) in a controlled crossover study including 27 diabetic patients aged 12.5 +/- 3.3 (mean; standard deviation; range: 5-19) years. All patients were treated with intensive insulin therapy, 14 with multiple injections, and 13 with pumps. The patients were randomized into an open or blind study arm. Both arms wore the CGMS sensor for 3 days every 2 weeks. CGMS profiles were used in the open study arm to adjust insulin therapy at follow-up visits every 6 weeks. Both the patients and the diabetes team were masked to the CGMS profiles in the blinded arm, and insulin therapy adjustments were based solely on 7-point BG profiles performed by the patients. At 3 months the 2 study arms were crossed over. RESULTS: Despite initial problems with a device new to both patients and the diabetes team, hemoglobin A(1)C decreased significantly in the open arm (from 7.70%-7.31%) but not in the blind arm (7.75%-7.65%). A total of 26/27 patients experienced daytime low subcutaneous glucose (<3.0 mmol/L;.8 episodes/day; duration 58 +/- 29 minutes; 5.5% of total time), and 27/27 patients had at least 1 nocturnal episode of low subcutaneous glucose (.4 episodes/night; duration 132 +/- 81 minutes; 10.1% of total time). CONCLUSIONS: Use of CGMS facilitated an improved treatment, and patients received new insight and increased motivation. In this study, we found CGMS to be a useful tool for education and improving metabolic control.

Adolescent↗

Undiagnosed asymptomatic hypoglycemia: diet, insulin, and glyburide for gestational diabetic pregnancy.

OBJECTIVE: The role of maternal hypoglycemia during pregnancy has not yet been established. We sought to estimate the prevalence of undiagnosed, asymptomatic hypoglycemic events that occur in diabetic patients. METHODS: All patients were evaluated using a continuous glucose monitoring system for 72 consecutive hours. The continuous glucose monitoring system measures in subcutaneous tissue interstitial glucose levels within a range of 40-400 mg/dL every 5 minutes for a total of 288 measurements per day. All patients were instructed regarding diabetic diet and assigned to pharmacological treatment as needed. Patients documented the time of food intake, insulin or glyburide administration, and all clinical hypoglycemic events. An asymptomatic hypoglycemic episode was defined as more than 30 consecutive minutes of glucose value below 50 mg/dL detected only by continuous glucose monitoring system reading without patient awareness. RESULTS: An evaluation of 82 patients with gestational diabetes was performed; 30 were insulin-treated, 27 were managed by diet only, and 25 were patients treated with glyburide. For purposes of comparison, data were obtained from 35 nondiabetic gravid women. Asymptomatic hypoglycemic events were identified in 19 of 30 (63%) insulin-treated patients and in 7 of 25 (28%) glyburide-treated patients. No hypoglycemic events were identified in patients with gestational diabetes mellitus treated by diet alone or in nondiabetic subjects. The mean recorded hypoglycemic episodes per day was significantly higher in insulin-treated patients (4.2 +/- 2.1) than in glyburide-treated patients (2.1 +/- 1.1), P =.03. In insulin-treated patients, the majority of the hypoglycemic events were nocturnal (84%), whereas in glyburide-treated patients, episodes were identified equally by day and night. CONCLUSION: Our data suggest that asymptomatic hypoglycemic events are common during pharmacological treatment in gestational diabetic pregnancies. We speculate that this finding may be explained by treatment modality rather than by the disease itself.

Adult↗