PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “AIR POLLUTION, RADIOACTIVE”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12Linked to original sources

Indoor radon concentration forecasting in South Tyrol.

In this paper a modern statistical technique of multivariate analysis is applied to an indoor radon concentration data base. Several parameters are more or less significant in determining the radon concentration inside a building. The elaboration of the information available on South Tyrol makes it possible both to identify the statistically significant variables and to build up a statistical model that allows us to forecast the radon concentration in dwellings, when the values of the same variables involved are given. The results confirm the complexity of the phenomenon.

Air Pollutants, Radioactive↗

Radon mapping in south Tyrol: comparison between two different procedures.

In this paper two different procedures for radon mapping have been compared on the same database referring to indoor radon records of South Tyrol. The first procedure is based on descriptive statistics applied to administrative units while the second one implies a more complicated statistical analysis applied to a regular grid: it involves floor level normalization of radon data, filling and smoothing algorithms for the territory cells.

Air Pollutants, Radioactive↗

Radon in the workplace: implications of studies of post-remediation monitoring.

Radon gas has been shown to cause an increased incidence of lung cancer. In affected areas, levels in the overground workplace can be sufficiently high to be a health risk and remediation is required. In the UK, the workplace Action Level is 400 Bq m(-3). The variation of radon levels in the workplace was studied both before and after remediation. In most rooms, remediation resulted in a greater reduction at night than during the working day. The dose reduction, and therefore the health benefit, to workers is less than that predicted by the drop in radon averaged over 24 h. In order to obtain a health benefit to 75% of workers in our series, the 24 h average radon level in each room must be reduced to <225 Bq m(-3). It is recommended that UK Regulatory Agencies adopt a post-remediation workplace Action Level of 225 Bq m(-3).

Air Pollutants, Occupational↗

Multiple radon survey in spa of Loutra Edipsou (Greece).

Various investigators are involved with radon research in Greece. Numerous measurements have been reported for different regions around the country. In this study we focus on the city of Loutra Edipsou, a spa centre of about 4000 inhabitants in the northern part of the island of Evia (Greece). This city is built on an area of high geothermal activity, a fact that served as a guide to our study. The aim was to estimate the dose delivered to inhabitants, the potential alpha energy exposure of bathers and spa personnel and to investigate the radon background in this area. The detectors used were of active type. Measurements are reported for dwellings, which were grouped into two different sets: one representing typical summer periods (July and August 2002) and the other typical winter periods (October and November 2002) The Potential Alpha Energy Exposure (PAEE) of the bathers during treatment lies in the range between (45 +/- 3) and (110 +/- 5) mWLM (1 WLM = 12.97 J s m(-3)). The PAEE of the working personnel lies in the range between (34 +/- 3) and (100 +/- 20) mWLM.

Air Pollutants, Radioactive↗

Radiological maps of outdoor and indoor gamma dose rates in Greek urban areas obtained by in situ gamma spectrometry.

The results obtained from 259 indoor and outdoor in situ gamma spectrometry measurements with a portable Ge detector and 707 total gamma dose rate measurements with an NaI detector in urban areas of 16 Greek islands are presented. From the in situ gamma spectra, the absorbed dose rate in air due to Uranium series, Thorium series, (40)K and (137)Cs are derived and discussed. The results obtained from the present work in conjunction with those reported previously were used for the realization of a complete indoor and outdoor gamma radiation map of Greek urban areas using in situ gamma spectrometry with portable Ge detector.

Air Pollutants, Radioactive↗

Radon hazard and risk in Sussex, England and the factors affecting radon levels in dwellings in chalk terrain.

A survey was undertaken of radon levels in 1013 dwellings in Sussex, UK. A number of dwellings were identified with high radon levels in an area previously considered to offer low radon risk from geological sources. Multiple regression was used to determine the relative influence of the various geographical and building-related factors on indoor radon levels. The radon hazard, independent of building-related effects, was determined for each surveyed location by standardising radon measurements to a 'model' dwelling. These were entered into a geographic information system and related to surface geology. The highest radon levels were found to be associated with the youngest Chalk formations, Tertiary deposits and Clay-with-flints Quaternary deposits in the area. Radon potentials were also determined for the area which can be used to estimate radon risk and assist in environmental planning and development control.

Air Pollutants, Radioactive↗

Fraction of the positive 218Po and 214Pb clusters in indoor air.

The fraction of the positively charged unattached radon decay products, 218Po and 214Pb in indoor air was determined by model calculations. The results of the calculations were confirmed by measurements in a test chamber (volume: 8 m3). The fraction of both radionuclides depends on the attachment parameter (S(1)) and the neutralisation rate (nu) in room air. The total removal parameter S1 = lambda1 + v + q(f) + X = lambda1 C1f/C0 considers the attachment rate to aerosol particles (X), plate-out rate to room surfaces (q(f)) and the ventilation rate (nu) (lambda1: decay constant of 218Po). The S1-value of room can be determined by measurement of the concentration of the unattached 218Po clusters (C1f) and radon (C0). The neutralisation rate (nu) in environmental air depends mainly on the ion production rate. The influence of the relative humidity in the range 30-95% (temperature: 20 degrees C) is negligible. In addition, equal neutralisation rates for 218Po and 214Pb could be derived. In room air with ion production rates between 5 and 500 nC kg(-1) h(-1) mainly generated by the alpha emitters of radon, thoron and their short-lived decay products, the fractions for positive 218Po clusters vary between 55 and 17% and for 214Pb clusters between 53 and 14%. For a typical average concentration of radon (50 Bq m(-3)) and thoron (10 Bq m(-3)) in homes, 48% of 218Po clusters and 45% of 214Pb clusters are positively charged.

Aerosols↗

Field comparison of two different passive radon detectors.

The present paper describes field performance of two different passive radon monitor devices formed, respectively, by a CR-39 track detector enclosed in a diffusion chamber and a cellulose nitrate detector (LR-115) in a heat-sealed polyethylene bag. The most important scope of these investigations was to study the performance of these detectors directly in the field. To this end, two different types of radon monitors mentioned above have been exposed simultaneously in 100 school rooms within the Italian region Friuli Venezia Giulia. Finally, the accuracy of their responses has been evaluated by exposing them under extreme humidity conditions and/or together with other radon measurement instruments.

Air Pollutants, Radioactive↗

Anomalous indoor radon concentration in a dwelling in Qatif City, Saudi Arabia.

An indoor radon survey was carried out recently in nine cities of Saudi Arabia using nuclear track detectors (NTD)-based passive radon detectors. The survey included Qatif City in the Eastern Province of Saudi Arabia, where 225 detectors were collected back successfully. It was found that the average indoor radon concentration in the dwellings was 22 +/- 15 Bq m(-3). However, one of the dwellings showed an anomalous radon concentration of 535 +/- 23 Bq m(-3). This finding led to a detailed investigation of this dwelling using active and passive techniques. In the active technique, an AlphaGUARD 2000 PRQ radon gas analyser was used. In the passive technique, CR-39 based passive radon detectors were used in all the rooms of the dwelling. Radon exhalation from the wall and the floor was also measured using the can technique. The active measurement confirms the passive one. Before placing the passive radon detectors in all the rooms of the two-storey building, the inhabitant was advised to ventilate his house regularly. The radon concentration in the different rooms was found to vary from 124 to 302 Bq m(-3). Radon exhalation from the floor and the wall of the room with the anomalous radon concentration was found to vary from 0.5 to 0.8 Bq m(-2) h(-1). These low radon exhalation rates suggest that the anomalous radon concentration is most probably due to underground radon diffusion into the dwelling through cracks and joints in the concrete floor.

Air Pollutants, Radioactive↗

Development of a radon trap device using a corona discharge.

Radon is one of the noble gases, which are chemically inert and do not make any reactants under normal conditions. In this experiment we demonstrated an enigmatic reaction between radon and fluorine when a corona discharge is used as a promoter. Distinctive changes in radon concentrations were caused by the discharge and a trap efficiency of >99.5% was estimated. The mass balance between the trapped and the released radon was found to be reasonable. This indicates the existence of chemical reactions with radon. This trap phenomenon has application as a technique for reducing radon concentration in radon-contaminated air. It is possible that this technique will be applicable to other noble gases.

Air Pollutants, Radioactive↗

Study on radon and radon progeny in some living rooms.

In the first part of this work, the potential alpha energy concentration (PAEC) of radon progeny, the equilibrium factor (F), the activity concentration of 222Rn gas (Co) and the unattached fraction (fp), were determined in 15 living rooms at El-Minia City, Egypt. The activity size distribution of (214)Pb was measured by using a low pressure Berner impactor. Based on the parameters of that distribution the total effective dose through the human lung was evaluated by using a dosimetric model calculation of ICRP. An electrostatic precipitation method was used for the determination of 222Rn gas concentration. The mean activity concentration of 222Rn gas (Co) was found to be 123 +/- 22 Bq m(-3). A mean unattached fraction (fp) of 0.11 +/- 0.02 was obtained at a mean aerosol particle concentration (Z) of (3.0 +/- 0.21) x 10(3) cm(-3). The mean equilibrium factor (F) was determined to be 0.35 +/- 0.03. The mean PAEC was found to be 37 +/- 8.1 Bq m(-3). The activity size distribution of (214)Pb shows mean activity median diameter of 290 nm with mean geometric standard deviation (sigma) of 2.45. At a total deposition fraction of approximately 23% the total effective dose to the lung was determined to be approximately 1.2 mSv. The second part of this paper deals with a study of natural radionuclide contents of samples collected from the building materials of those rooms under investigation given in part one of this paper. Analyses were performed in Marinelli beakers with a gamma multichannel analyser provided with a NaI(Tl) detector. The samples have revealed the presence of the uranium-radium and thorium radioisotopes as well as (40)K. Nine gamma-lines of the natural radioisotopes that correspond to 212Pb, 214Pb, 214Bi, 228Ac, 40K and 208Tl were detected and measured. The activity concentrations of 226Ra, 232Th and 40K were determined with mean specific activities of 65 +/- 22, 35 +/- 12 and 150 +/- 60 Bq kg(-1), respectively. These activities amount to a radium equivalent (Ra(eq)) of 126 Bq kg(-1) and to a mean value of external hazard index of 0.34.

Aerosols↗

Assessment of external dose indoors in Lithuania.

The aim of this paper was an assessment of external exposure indoors and its dependence on construction materials and indoor radon concentrations in Lithuanian living houses. Relationship of absorbed dose rate in air indoors and activity indexes of the most commonly used construction materials (wood, concrete and bricks) have been studied using results received in measurements done in >4700 rooms in 1995-2005. Possible connections of dose rate indoors with indoor radon concentrations are also discussed. Findings of this study helped to make an assessment of the mean value of effective dose of Lithuanian population due to external exposure indoors which is equal to 0.58 mSv y-1. The received data might also be used in improvement of quality of personal dosimetric measurements done in premises constructed of different construction materials.

Air Pollutants, Radioactive↗

Radon survey and exposure assessment in hospitals.

In this study radon (222Rn) in indoor air was surveyed in 201 rooms of 26 major hospitals in Slovenia and annual effective doses for 1025 persons working in the rooms surveyed were estimated. Instantaneous radon concentrations were measured with alpha scintillation cells, long-term average concentrations with etched track detectors and electret detectors, and radon, its progeny and equilibrium factor were continuously recorded with portable devices. Effective doses were estimated by using ICRP Publication 65 methodology. Only in seven rooms did the average radon concentration, obtained by 1 month exposing etched track detectors, exceed the national limit of 400 Bq m-3; and these places will be mitigated; elsewhere it was lower. Annual effective doses for 966 persons (94.2%) were estimated as <1 mSv, but for 10 persons they were between 2.1 and 7.3 mSv. The results warn that in an environment with generally low radon levels, 'hot' points may be found, and therefore radon surveys should be carefully designed and performed in order not to miss them.

Air Pollutants, Radioactive↗

Indoor radon concentration measurement in the dwellings of Al-Jauf region of Saudi Arabia.

Indoor radon concentration measurement in the dwellings of Al-Jauf region of Saudi Arabia was carried out using passive radon dosemeters. The objective of this radon survey was to obtain representative indoor radon data of Al-Jauf region. The study is a continuation of radon survey in main cities of Saudi Arabia which constitutes a baseline for Saudi Arabia in the Radon World Atlas. A total of 318 passive radon dosemeters were distributed randomly in the region and placed for a period of 1 y starting from April 2004 to April 2005. The results of indoor radon concentration measurement in 136 dwellings distributed in Al-Jauf region are presented. The remaining dosemeters were lost in the dwellings or mishandled. The results showed that the average, minimum, maximum radon concentrations and standard deviation were 35, 7, 168 and 30 Bq m(-3), respectively. Geometric mean and geometric standard deviation of the radon distribution were found to be 28 and 1.83, respectively.

Air Pollutants, Radioactive↗

Influence of environmental changes on continuous radon monitors. Results of a Spanish intercomparison exercise.

The first Spanish intercomparison exercise for continuous radon monitors was carried out with the participation of nine monitoring systems from eight laboratories. The exposures were carried out in the radon and thoron chambers at the Institute of Energy Techniques (INTE) of the Technical University of Catalonia (UPC), which is considered to be the Spanish reference chamber. The monitors were exposed to three different temperatures (13, 20 and 30 degrees C), relative humidities (30, 45 and 80%) and radon concentrations (450, 2000 and 9000 Bq m(-3)). Exposures in the thoron chamber were carried out at concentrations of approximately 450 Bq m(-3). The response of the ionisation chambers and scintillation monitors was acceptable. However, the response of monitors based on electrostatic collection was found to be influenced by external climatic conditions. Moreover, all radon monitors were sensitive to thoron concentration, which was especially significant for scintillation monitors.

Air Pollutants, Radioactive↗

Indoor air radon concentration in schools in Prizren, Kosovo.

Indoor air radon ((222)Rn) concentrations were measured in spring and winter in 30 rooms of 9 elementary schools and 19 rooms of 6 high schools in Prizren, Kosovo, using alpha scintillation cells. Only in three rooms of elementary schools and four rooms of high schools did winter concentrations exceed 400 Bq m(-3).

Air Pollutants, Radioactive↗

Prediction of 222Rn in Danish dwellings using geology and house construction information from central databases.

A linear regression model has been developed for the prediction of indoor (222)Rn in Danish houses. The model provides proxy radon concentrations for about 21,000 houses in a Danish case-control study on the possible association between residential radon and childhood cancer (primarily leukaemia). The model was calibrated against radon measurements in 3116 houses. An independent dataset with 788 house measurements was used for model performance assessment. The model includes nine explanatory variables, of which the most important ones are house type and geology. All explanatory variables are available from central databases. The model was fitted to log-transformed radon concentrations and it has an R(2) of 40%. The uncertainty associated with individual predictions of (untransformed) radon concentrations is about a factor of 2.0 (one standard deviation). The comparison with the independent test data shows that the model makes sound predictions and that errors of radon predictions are only weakly correlated with the estimates themselves (R(2) = 10%).

Air Pollutants, Radioactive↗

Indoor radon in rural dwellings of the South-Pannonian region.

The results of indoor radon survey in the South-Pannonian Province Vojvodina (Serbia and Montenegro) are presented. The sampling strategy was oriented towards suburban and urban regions in the Province. For the dwellings typical for such regions the geometric mean annual radon activity concentration of 76.1 Bq m(-3) is measured (1000 measurements). This result leads to the annual dose estimate of 4.3 mSv y(-1), which is above the recommended action limit of ICRP. For urban dwellings in Novi Sad (the Province capital), the annual mean value of 54 Bq m(-3) (220 measurements) is obtained. By comparison of these two results it is concluded that radon surveys based on measurements in urban environment may seriously underestimate the radon-related health risk. The elevated radon levels could not be explained by elevated uranium levels of surface soil.

Air Pollutants, Radioactive↗