PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Angiography”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12Linked to original sources

Evaluation of left ventricular systolic function by 3D echocardiography: a comparative study with X-ray angiography and radionuclide angiography.

OBJECTIVE: the aim of this study was to evaluate left ventricular systolic function by 3D ultrasound as compared to with radionuclide and X-ray angiographies. METHODS: one hundred and four patients were examinated by 3D ultrasound (3D-US) but only 72 examinations were successful. Thirty patients were investigated by 3D-US, M-mode US or bidimensional (2D) US, and X-ray angiography (group I) and 42 patients were investigated by 3D-US, M-mode, or 2D, and radionuclide angiography (group II). RESULTS: the correlation between ejection fraction (EF) evaluated by 3D-US and reference methods was found to be good and similar for the two groups (r=0.75; P<10(-4) for group I and r=0.76; P<10(-4) for group II). The correlation between EF calculated by conventional 2D-US and by reference methods was lower (r=0.60; P=0.04 for group I and r=0.54; P=0.001 for group II). The correlation between EF evaluated by 3D- and 2D-US was modest (r=0. 55; P=0.001 for the whole group). The correlation between 3D-US left ventricle end-diastolic volume (EDV) and end-systolic volume (ESV) and those evaluated by X-ray angiography was also modest (r=0.33; NS for EDV and r=0.60; P<10(-4) for ESV). The correlations between EDV and ESV in 3D-US, and those evaluated from radionuclide angiography were fairly good and in the same range (r=0.76; P<10(-4) and r=0.87; P<10(-4)). CONCLUSION: the 3D-US system using a rotating probe in an apical view is valuable for evaluation of left ventricular systolic function.

Angiocardiography↗

Oral fluorescein angiography with the scanning laser ophthalmoscope in diabetic retinopathy: a case controlled comparison with intravenous fluorescein angiography.

AIM: To compare the performance of oral fundus fluorescein angiography with a confocal scanning laser ophthalmoscope (SLO) with intravenous fundus fluorescein angiography (IVFFA) with a fundus camera in the assessment of sight-threatening diabetic retinopathy. PATIENTS AND METHODS: A total of 25 patients undergoing IVFFA to investigate their diabetic retinopathy were recruited. Participants returned 1 week later and an oral angiogram with the SLO was performed. Six facets of the oral and intravenous angiograms were scored and compared: visualization of the foveal avascular zone (FAZ); branch retinal identification; macular leakage; identification of microaneurysms in areas of macular leakage; peripheral nonperfusion, and leakage from neovascular complexes. RESULTS: Compared to IVFFA, the FAZ was unreliably visualized with oral angiography (Kappa 0.1, 95% CI 0-0.3). In contrast, macular leakage (Kappa 0.78, 95%, CI 0.72-0.83), identification of microaneurysms in areas of macular leakage (Kappa 0.78, 95%, CI 0.72-0.83), and neovascular complexes (Kappa 1.0) were reliably seen. Analysis of the visualization of peripheral nonperfusion was complicated by the finding that profuse dye leakage from neovascular complexes obscured the view of the peripheral retina. If the five angiograms in which this occurred were excluded, oral angiography identified 23 of the 24 eyes in which significant nonperfusion was found on IVFFA. CONCLUSION: Oral angiography with the SLO can provide high-quality angiograms that allow judgments to be made about the presence of treatable diabetic maculopathy, proliferative diabetic retinopathy, and peripheral nonperfusion. In the presence of coexisting macular oedema, it proved to be an unreliable technique with which to investigate foveal ischaemia.

Administration, Oral↗

Elongated eccentric soft coronary plaque: major diagnostic pitfall on quantitative coronary angiography overpowered by computed tomography coronary angiography and intravascular ultrasound.

We describe a significant left anterior descending coronary lesion in a patient with unstable angina pectoris. This lesion was erroneously underestimated using quantitative coronary angiography; however, CT coronary angiography correctly showed a significant, elongated, eccentric, soft plaque that was later confirmed by repeated quantitative coronary angiography with intravascular ultrasound. As showed, CT coronary angiography may offer a reliable non-invasive alternative to quantitative coronary angiography and intravascular ultrasound by enabling a true 3-D coronary lumenogram combined with plaque detection and characterization.

Angioplasty, Balloon, Coronary↗

Free-breathing 3D steady-state free precession coronary MR angiography with radial k-space sampling: comparison with cartesian k-space sampling and cartesian gradient-echo coronary MR angiography--pilot study.

The authors compared radial steady-state free precession (SSFP) coronary magnetic resonance (MR) angiography, cartesian k-space sampling SSFP coronary MR angiography, and gradient-echo coronary MR angiography in 16 healthy adults and four pilot study patients. Standard gradient-echo MR imaging with a T2 preparatory pulse and cartesian k-space sampling was the reference technique. Image quality was compared by using subjective motion artifact level and objective contrast-to-noise ratio and vessel sharpness. Radial SSFP, compared with cartesian SSFP and gradient-echo MR angiography, resulted in reduced motion artifacts and superior vessel sharpness. Cartesian SSFP resulted in increased motion artifacts (P <.05). Contrast-to-noise ratio with radial SSFP was lower than that with cartesian SSFP and similar to that with the reference technique. Radial SSFP coronary MR angiography appears preferable because of improved definition of vessel borders.

Adult↗

Bronchial and nonbronchial systemic arteries at multi-detector row CT angiography: comparison with conventional angiography.

PURPOSE: To retrospectively evaluate bronchial and nonbronchial systemic arteries at multi-detector row helical computed tomography (CT) compared with conventional angiography in patients undergoing endovascular treatment of hemoptysis. MATERIALS AND METHODS: Neither institutional board approval nor informed consent was required. Forty-eight consecutive patients (39 men, nine women; mean age, 55.7 years; range, 20-82 years) with hemoptysis of bronchial and nonbronchial systemic artery origin underwent multi-detector row helical CT angiography of the thorax with use of a four-detector row (n = 31) or 16-detector row (n = 17) scanner prior to embolization. Findings on CT angiograms, including CT scans, maximum intensity projections, and three-dimensional volume-rendered images, were used to evaluate the depiction of bronchial and nonbronchial systemic arteries. Retrospective analysis of the ostium and the course of bronchial and/or nonbronchial systemic arteries on CT angiograms enabled evaluation of the accuracy of this technique in identification of the relevant vasculature. RESULTS: Among the 46 patients initially treated with bronchial artery embolization, 58 bronchial arteries were identified at CT and/or angiography. In 50 (86%) cases, concordant findings were observed with both modalities. In five (9%) cases, CT could not be used to identify the ostia of bronchial arteries. In three (5%) cases, CT depicted bronchial arteries that could not be selectively catheterized. Three-dimensional images were found to be superior to transverse CT scans in depicting the ectopic origin of the bronchial arteries, which enabled the interventional radiologists to perform successful embolization after direct catherization of the ectopic vessel in every case. In five (11%) patients, the nonbronchial systemic origin of bronchial bleeding was identified on CT angiograms. CONCLUSION: Multi-detector row helical CT angiography provides more precise depiction of bronchial and nonbronchial systemic arteries than does conventional angiography.

Adult↗

Renal artery stenosis: detection and quantification with spiral CT angiography versus optimized digital subtraction angiography.

PURPOSE: To compare spiral computed tomographic (CT) angiography with optimized digital subtraction angiography (DSA) for accurate detection and quantification of renal artery stenosis. MATERIALS AND METHODS: In 71 consecutive patients with possible renovascular hypertension, spiral CT angiography was performed of the renal arteries before DSA. Optimized DSA (performed with projection angles calculated from axial spiral CT source images) was used as the standard. Two independent observers evaluated spinal CT angiograms for the presence and grade of renal artery stenosis. Sensitivity, specificity, and interobserver variability were calculated. RESULTS: With spiral CT angiography, all 166 renal arteries and accessory arteries were identified correctly by both reviewers. Overall sensitivity and specificity for assessment of stenoses of grade 0 (none), grade 1 (1%-49%), grade 2 (51%-99%), and grade 3 (occlusion) were 97% and 100%, 92% and 98%, 96% and 96%, and 100% and 100%, respectively. Agreement was strong between spiral CT angiographic and DSA findings in assessment of all grades of stenosis (kappa coefficient, 0.9 and 0.9, respectively) for the two observers. CONCLUSION: Spiral CT angiography enabled accurate assessment of renal artery stenosis in patients with possible renovascular hypertension and may assist in selecting patients for interventional treatment.

Adult↗

Diagnosing acute pulmonary embolism: effect of chronic obstructive pulmonary disease on the performance of D-dimer testing, ventilation/perfusion scintigraphy, spiral computed tomographic angiography, and conventional angiography. ANTELOPE Study Group. Advances in New Technologies Evaluating the Localization of Pulmonary Embolism.

In patients with chronic obstructive pulmonary disease (COPD), differentiating a pulmonary embolism (PE) from an exacerbation of COPD can be difficult, since clinical signs and symptoms of the two conditions overlap. Development of reliable noninvasive or minimally invasive techniques for the diagnosis of PE is, especially in these patients, necessary. In this study we assessed the effect of COPD on the accuracy of the clinical probability estimate (CPE), spiral computed tomographic angiography (SCTA), D-dimer analysis, ventilation perfusion (V/Q) scintigraphy, and pulmonary angiography for the diagnosis of PE. From May 1997 through March 1998, 627 consecutive patients with suspected PE were investigated in six teaching hospitals. In these patients, D-dimer testing, CPE, V/Q scintigraphy, and SCTA and/or pulmonary angiography were performed according to a strict diagnostic protocol. The patients were also independently categorized as having COPD or not. A diagnosis of COPD was established in 91 patients (15%). The prevalence of PE was similar in patients with and without COPD (29% and 31%, respectively), notwithstanding the larger proportion of nondiagnostic V/Q scan results in patients with COPD (46% versus 21%, p < 0.001). The distribution of CPEs, diagnostic value of the D-dimer assay and SCTA, and reproducibility of pulmonary angiography were comparable among patients with and without COPD. The presence of COPD does not affect the diagnostic performance of CPE, D-dimer testing, SCTA, or pulmonary angiography. Furthermore, although more nondiagnostic V/Q scan results can be expected in the presence of COPD, V/Q scintigraphy remains a valuable screening test in patients with COPD.

Acute Disease↗

Operation of arteriovenous malformations assisted by stereoscopic navigation-controlled display of preoperative magnetic resonance angiography and intraoperative ultrasound angiography.

OBJECTIVE: To study the application of navigated stereoscopic display of preoperative three-dimensional (3-D) magnetic resonance angiography and intraoperative 3-D ultrasound angiography in a clinical setting. METHODS: Preoperative magnetic resonance angiography and intraoperative ultrasound angiography are presented as stereoscopic images on the monitor during the operation by a simple red/blue technique. Two projections are generated, one for each eye, according to a simple ray casting method. Because of integration with a navigation system, it is possible to identify vessels with a pointer. The system has been applied during operations on nine patients with arteriovenous malformations (AVMs). Seven of the patients had AVMs in an eloquent area. RESULTS: The technology makes it easier to understand the vascular architecture during the operation, and it offers a possibility to identify and clip AVM feeders both on the surface and deep in the tissue at the beginning of the operation. All 28 feeders identified on the preoperative angiograms were identified by intraoperative navigated stereoscopy. Twenty-five were clipped at the beginning of the operation. The other three were clipped at a later phase of the operation. 3-D ultrasound angiography was useful to map the size of the nidus, to detect the degree of brain shift, and to identify residual AVM. CONCLUSION: Stereoscopic visualization enhances the surgeon's perception of the vascular architecture, and integrated with navigation technology, this offers a reliable system for identification and clipping of AVM feeders in the initial phase of the operation.

Adult↗

Three-dimensional spiral CT angiography in pancreatic surgical planning using non-tailored protocols: comparison with conventional angiography.

The aim of this study was to investigate three-dimensional spiral computed tomography (3DCT) as an adjunct to routine pancreatic CT scanning, with particular regard to the identification of surgically important hepatic arterial anomalies, correlated with conventional visceral angiography. 32 patients underwent spiral CT scans prior to pancreatic surgery using established protocols. Oral contrast medium was used throughout. 150 ml of intravenous contrast medium was given at 3 ml s-1 with a 24 s spiral CT sequence starting 35 s after the start of infusion. Two protocols were employed, both with a pitch of 1:3 mm table feed/collimation (n = 17) and 5 mm table feed/collimation (n = 15). Overlapping (1 mm minimum) axial reformats were reconstructed. 3DCT shaded-surface displays of the visceral arteries were assessed for visceral arterial anomalies. Visceral angiography (n = 23) was independently correlated. Satisfactory 3D angiograms were performed in all but one patient, in whom the coeliac axis was missed. (i) 3 mm protocol: 3DCT (n = 17) showed three anomalous right hepatic arteries (ARHA), one trifurcation anomaly and one splenic artery with an aortic origin. Angiography (n = 11) confirmed these findings, although one patient with an ARHA did not have angiography. A left gastric arterial supply to the left liver was not detected. (ii) 5 mm protocol: 3DCT (n = 15) showed two cases of ARHA. While confirming these findings, angiography (n = 12) showed a third case of ARHA, in which the coeliac and superior mesenteric artery had very close origins. A left gastric supply to the left liver was also missed. It is concluded that satisfactory 3DCT is possible without changing existing scanning protocols, although narrow sections are required for the confident assessment of right hepatic arterial anomalies, and any left hepatic supply via the left gastric artery was poorly assessed in this series.

Adolescent↗

Comparison of CT angiography with conventional arterial angiography in aortoiliac occlusive disease.

This study compared the results of conventional and CT angiography of the aortoiliac segment in 35 patients with occlusive disease. Disease severity was graded into five categories. Two assessors independently assessed the segment from the distal abdominal aorta to the proximal superficial femoral artery and a consensus was formed. There was interobserver agreement in 87% of segments for conventional angiography and in 78% for CT angiography. Comparison of the two modalities gave identical grading in 84% of segments. Dissimilar grading was found in 16%, with a roughly equal number of undergrading and overgrading. CT angiography has the advantages of being minimally invasive, requiring only an intravenous injection of contrast medium and imaging surrounding soft tissues. Multiplanar reconstruction aids the visualization of asymmetrical stenoses, and collateral blood supply is readily appreciated. However, CT angiography may fail to demonstrate short stenoses owing to limited z-axis resolution.

Angiography, Digital Subtraction↗

Continuous bleeding from a basilar terminus aneurysm imaged with CT angiography and conventional angiography.

We report a case of fatal subarachnoid hemorrhage from nontraumatic rupture of an aneurysm at the basilar terminus in which both computed tomography angiography and conventional angiography showed evidence of active bleeding. The time period from initial ictus to CT angiography was 30-50 minutes and to conventional angiography was 120-140 minutes. This case illustrates that aneurysmal bleeding is not necessarily as brief as a few seconds and can last up to 30 to 50 minutes and perhaps longer. Continued bleeding from an intracranial aneurysm is a rare event that can be recognized using computed tomography angiography and likely indicates a poor prognosis.

Adult↗

Comparison of preoperative standard angiography with preoperative balloon occlusion femoral angiography of the lower extremity.

The use of saphenous vein in situ bypass for limb salvage has increased the need for adequate visualization of distal lower extremity vessels. Preoperative angiographic techniques are often inadequate, requiring multiple films, extensive patient manipulation, or excessive dye loads. Intraoperative prereconstructive angiography permits adequate distal vessel visualization, but at a significant waste of time and expense if no usable distal vessels are found. There is a need for a reliable means of preoperative angiography in patients being evaluated for saphenous vein in situ bypass. Preoperative balloon occlusion femoral angiography was compared to preoperative standard angiography of the lower extremity in 39 patients referred to the University of Minnesota for limb salvage. Balloon occlusion femoral angiography significantly improved the preoperative ability to visualize lower extremity vessels distal to the superficial femoral artery in this group of patients.

Adult↗

[Comparison of magnetic resonance angiography and digital angiography of the epiaortic vessels].

Atheromasic lesions and other pathologic conditions of the arterial vessels of the neck are the most frequent causes of cerebrovascular disease. Diagnostic imaging currently employs digital subtraction angiography (DSA), Doppler, and color-Doppler US to study these conditions. Digital subtraction intraarterial angiography (DSAA) can provide both an early diagnosis and an accurate preoperative depiction of neck vessels; however, in spite of its effective value, it still remains an invasive technique. Magnetic Resonance angiography (angio-MR) is the latest technique allowing the depiction of neck vessels morphology. It shares with digital angiography the capability of supplying spatial depiction of all the examined vascular structures, and with US its noninvasiveness. The authors investigated angio-MR capabilities in providing accurate and detailed images of neck arteries; the images were then compared with DSA ones. Thirty patients with cerebrovascular diseases were studied. MR imaging was performed with a 1.5 T unit with a dedicated coil, and gradient-echo sequences were employed. Refocused sequences for flow were acquired on both the coronal and the sagittal planes, with the following parameters: TR 40, TE 10, flip angle 25 degrees, acquisition volumes 80-35 mm, 64-15 frames. Digital angiography demonstrated 101 vascular lesions: 27 slight stenoses (less than 30%), 19 mild stenoses (31-70%), 12 severe stenoses (71-99%), 7 occlusions, 14 coilings, 7 kinkings, and 15 hypoplasias of vertebral artery. In slight stenoses, angio-MR underestimated the condition in 11/27 patients. In mild and severe stenoses, as well as in occlusive diseases, angio-MR tended to overestimate the condition. In coiling, kinking, and hypoplasia, angio-MR yielded the same results as DSA.

Angiography, Digital Subtraction↗

Radiologic diagnosis of liver metastases in colo-rectal carcinoma. Prospective evaluation of the accuracy of angiography, ultrasonography, computed tomography and computed tomographic angiography.

To evaluate the accuracy of radiologic methods in liver metastases from colo-rectal carcinoma, a prospective investigation of 71 patients was performed. These patients were examined by angiography, ultrasound (US), computed tomography (CT) and computed tomographic angiography (CTA). The primary aim of the investigation was to determine the accuracy of CTA. The results of these examinations were then compared with the results from inspection and palpation of the liver at laparotomy. An analysis of liver tumor distribution, as well as a lesion-by-lesion analysis, was performed. In 20 patients, tumor growth was found in the liver in 36 lobes/segments at laparotomy. Three patients called false positives (angiography 2, US, CT and CTA 3 patients) turned out to be true positives since the lesions were overlooked at operation. The changes in sensitivity obtained when these patients are considered are given in parentheses. Of the lobes/segments affected by tumor growth at surgery, angiography revealed 47 (48) per cent, US 69 (71) per cent, CT 80 (82) per cent and CTA 83 (84) per cent. At a lesion-by-lesion analysis, angiography showed 33 per cent, US 69 per cent, CT 61 per cent and CTA 76 per cent of the lesions. Because of a larger number of false positives recorded with CTA compared with CT the former examination is not suitable as a single method for evaluating resectability of liver metastases.

Adult↗

[Angiography during interventional procedures with carbon dioxide (CO2) (carbo-angiography) in patients with increased contrast media risk].

Within the last 18 months we examined 130 patients with known complications or contraindications using iodinated contrast media for angiography by using carbon dioxide as contrast agent in digital subtraction angiography technique. These were diagnostic pelvis-leg angiographies (n = 106) with simultaneous consecutive interventional radiologic therapy in 68 cases. In 19 dialysis access fistulas 11 angioplasties were performed in the same session. In 5 cases of renal allografts no interventional radiologic therapy was necessary. For CO2 application an electronic controlled special injector was used. Carbon dioxide has a number of advantages: no adverse reactions, nonallergenic and can be used several times without increasing risks and is cost-saving. CO2 angiography is a sensitive method, for detection vessel wall processes below the diaphragm. It can replace conventional angiography.

Angiography, Digital Subtraction↗

Intracranial stenoocclusive disease: double-detector helical CT angiography versus digital subtraction angiography.

BACKGROUND AND PURPOSE: To our knowledge, no large-scale studies comparing the accuracy of CT angiography (CTA) to intraarterial digital subtraction angiography (DSA) of intracranial stenosis have been reported. We attempted to determine the diagnostic value of intracranial CT angiography (CTA) of normal vasculature and variants as well as of stenoocclusive disease. METHODS: One-hundred and twelve patients underwent CTA and intraarterial angiography, and 2205 vascular segments were examined to ascertain presence, visibility, and degree of arterial stenoses (n = 105) as well as anatomic variants. Source, maximum intensity projection (MIP), and MIP-generated multiplanar reformatted (MPR) images were evaluated. RESULTS: All 55 anatomic variants were identified correctly. Visibility of small-vessel segments was increased from 75% to 83% by using source images. MPR was helpful in differentiating distal vertebral hypoplasia from stenosis and in overcoming artifacts. All 43 occlusive segments were graded correctly (sensitivity = 100%, predictive value = 93.4%) as follows: severely stenotic ([n = 23], sensitivity = 78%, predictive value = 81.8%); moderately stenotic ([n = 36], sensitivity = 61%, predictive value = 84.6%); and mildly stenotic ([n = 3], sensitivity = 66%, predictive value = 28%). Normal segments (n = 2100) had a sensitivity of 99.5%, and CTA evinced a specificity of 99% for detecting stenoocclusive disease. Approximately one-third of wrong assessments were related to the petrous segment of the carotid artery. CONCLUSION: CTA with double-detector technology and advanced postprocessing algorithms, including MPR, is about as reliable as MRA in depicting the vasculature of the anterior and posterior circulation and in grading intracranial stenoocclusive lesions, with the exception of the petrous segment of the carotid artery. CTA might be superior to MRA in the evaluation of poststenotic low-flow segments.

Angiography, Digital Subtraction↗

Transaxillary angiography: an acceptable approach when perfemoral angiography is not acceptable.

Transaxillary angiography has been performed in a consecutive series wherever patients were unsuitable for perfemoral angiography. Between 1984 and 1986, transaxillary angiography was performed for 103 patients (81 males and 22 females with a mean age of 64 years). Major complications occurred in 2 patients (1.9%) who required surgical embolectomy with no long term sequelae. Three (2.9%) had a transient neurological deficit which lasted less than 1 week. In our hands transaxillary angiography is the best alternative when perfemoral angiography is not possible.

Adult↗

Comparison of conventional pulmonary angiography with intravenous digital subtraction angiography for pulmonary embolic disease.

Intravenous digital subtraction pulmonary angiography was performed in 33 patients with suspected pulmonary embolism. It was performed as the initial examination, followed immediately by conventional film-screen pulmonary angiography performed with selective right or left main pulmonary injections. Intravenous studies of diagnostic quality were obtained in 31 of 33 patients (93.9%). Of the satisfactory intravenous studies, pulmonary embolism was correctly diagnosed in 12 cases and excluded in 18 cases. Emboli were detected in major and second-order branches, and occasionally in third-order branches as well. There was one false-positive intravenous pulmonary study, but the overall accuracy was 90.9% considering all studies and 96.8% excluding the two inadequate intravenous examinations. It is concluded that intravenous pulmonary angiography is an acceptable substitute for routine pulmonary angiography in most patients with suspected major pulmonary embolism. The technique is less expensive, and is safer, faster, and easier to perform than conventional pulmonary angiography.

Diagnosis, Computer-Assisted↗