Role of hemoglobin denaturation and band 3 clustering in initiating red cell removal.
Explore the source record for details and available documents.
SEARCH · PubMed Health
Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Measurement of complement components in serum may not accurately assess the degree of activation of the complement system. An alternative approach is the measurement of conversion products of the complement components. The relation between the presence of an increased concentration of C3-conversion products and the metabolism of C3 was investigated. In a group of patients, circulating immune complexes were also measured (Clq-binding test) to see whether the combination of those markers yielded information on the C3 metabolism. In this study it is shown that static measurements of serum C3 levels is of no value for the degree of complement activation. Measurement of C3-conversion products may indicate C3 hypercatabolism (in 8 of the 11 patients with C3-conversion products), but it does not imply depressed C3 synthesis. Detection of circulating immune complexes by the C1q-binding assay did not always indicate a C3 hypercatabolism. Of 12 SLE patients studied, in 9 of them, a C3 hypercatabolism was detected, and 5 of these patients were clinically characterized by the presence of minor disease symptoms. Overall, the results indicated that detection of circulating immune complexes and/or C3-conversion products could not be used as an absolute measure for insight into the C3 metabolism.
Activation of C3 and factor B in normal human serum by P. ovale was demonstrated using a standard unidirectional immunoelectrophoresis technique. Activation of complement by the alternative (properdin) pathway is a possible mechanism by which P. ovale may mediate an inflammatory response.
In a girl with recurrent haemolytic uraemic syndrome (HUS), persistently low serum levels of C3 were found. Analysis of complement phenotype revealed a hypomorphic variant of C3 Fast in the patient (C3fS) and a normal heterozygous pattern in both parents and the brother (C3FS). Other complement aberrations in the patient were: the presence of a null gene for C4A and C4B and low serum levels of factor H. The father also had partial factor H deficiency. It is hypothesized that the hypomorphic C3 variant may predispose to recurrent HUS. In the acquired forms the role of uraemia in alteration of C3F should be considered.
Small unilamellar vesicles containing clodronate (SUVc) injected intravenously will deplete splenic macrophages and the degree of histological depletion can be assessed by determining the clearance and uptake of monoclonal antibody coated erythrocytes. Splenic Fc dependent clearance, assessed in decomplemented animals, provides a more sensitive index of the effects of large multilamellar liposome encapsulated clodronate (MLVc) and SUVc than does the clearance of complement coated erythrocytes on macrophage depletion in the spleen. MLVc were more efficient than SUVc in inducing a reduction in the number of red pulp macrophages within the spleen. Receptor specific red cell uptake in the spleen could be used as an alternative to histology when assessing splenic macrophage depletion. Encapsulation of clodronate is crucial to its depleting effect since the free drug in saline does not change splenic macrophage number or function.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Measurement of the complement activation products C1s:C1-inh, C3bP and C5b-9 by ELISA in plasma samples from normals, rheumatoid arthritis (RA) and systemic lupus erythematosis (SLE) patients showed significantly elevated levels in the two patient groups (P less than 0.0001 for C1s:C1-inh, C3bP and C5b-9) compared to normals. In seropositive RA patients there were significant correlations between the levels of the three complement activation complexes and IgM-RF, IgG-RF and IgA-RF. However, IgM-RF did not interfere with any of the ELISA systems. Mean levels of C1s:C1-inh, C3bP and C5b-9 were the same in paired plasma and synovial fluids; however, C3bP levels in the paired samples did not correlate with one another by rank. Our conclusions are that: (a) elevated plasma levels of these complement activation products are detectable in rheumatic diseases; (b) plasma levels of these complement activation products are related to Rheumatoid factor (RF) levels in seropositive RA patients; and (c) IgM-RF does not influence these solid-phase ELISA procedures.
Explore the source record for details and available documents.
Complement activation is believed to be of importance in the development of complications arising after cardiopulmonary bypass. The effect on complement activation of priming the extracorporeal circuit with crystalloid alone, crystalloid plus albumin, or crystalloid plus the plasma expander polygeline was assessed in 36 patients undergoing coronary artery operations with cardiopulmonary bypass using a bubble oxygenator. Activation of the alternative and common complement pathways was monitored before, during, and after the bypass period by measuring concentrations of factor B and its fragment Ba and C3 and its fragment C3d. Complement activation occurred in all three groups of patients, with no difference between the crystalloid and crystalloid-albumin groups. In contrast, Ba fragment concentrations were persistently and significantly lower during and after bypass in the polygeline group, denoting reduced complement activation. C3d levels also showed a tendency to be lower in this group. Our results indicate that addition of polygeline to the priming solution reduces complement activation. Because complement activation is associated with morbidity after cardiopulmonary bypass, addition of polygeline to the priming solution may offer an inexpensive method of reducing morbidity after cardiopulmonary bypass.
Plasma concentrations of the granulocyte cell marker calprotectin were assessed during operation and 24 hours postoperatively in patients undergoing coronary artery bypass grafting with cardiopulmonary bypass, abdominal aneurysmectomy with implantation of an aortic graft, or thoracotomy without implantation of synthetic material. The concentration of calprotectin increased significantly (p < 0.01) in all three groups. Ten of the 30 patients in the group undergoing cardiopulmonary bypass received methylprednisolone at the start of the operation. No difference in calprotectin concentration was seen between the two subgroups (p > 0.05). Plasma concentration of calprotectin was shown to increase rapidly in patients undergoing cardiopulmonary bypass and aneurysmectomy, in whom complement activation also took place. However, the calprotectin concentration increased slowly during the operation and the postoperative period in patients undergoing a thoracotomy, in whom complement was not activated. At wound closure the calprotectin concentration was significantly elevated in the cardiopulmonary bypass and aneurysmectomy groups compared with the thoracotomy group (p < 0.05). The calprotectin concentration remained elevated during the postoperative period in all three groups. Our results indicate that calprotectin may serve as a suitable cellular marker when the biocompatibility of artificial surfaces is studied.
BACKGROUND: Centrifugal pumps are being used increasingly for short-term extracorporeal circulation purposes such as during heart operations. Whether the centrifugal pump improves the cardiopulmonary bypass biocompatibility has not been fully documented. METHODS: A roller pump (n = 20) was compared in vivo with a centrifugal pump (n = 20) in groups of patients in which cardiopulmonary bypass circuits that were either totally heparin coated (Carmeda BioActive Surface; n = 20) or uncoated (n = 20) were used. We expected the heparin coating to attenuate blood activation, thus possibly making the comparison of the two pumps easier with respect to their different blood activation potentials. Samples of blood plasma, obtained during cardiopulmonary bypass from low-risk coronary artery bypass grafting patients, were analyzed for hemolysis (plasma haemoglobin), complement activation (C3bc and the terminal complement complex), a complement lytic inhibitor (vitronectin), coagulation activation (fibrinopeptide A), granulocyte activation (lactoferrin), and platelet activation (beta-thromboglobulin). RESULTS: The concentrations of terminal complement complex, lactoferrin, and beta-thromboglobulin were significantly lower in association with heparin-coated surfaces. The concentration of plasma hemoglobin was significantly lower in association with the centrifugal pump. In uncoated circuits, the beta-thromboglobulin level was significantly higher in association with the roller pump than with the centrifugal pump, but this significant reduction in the beta-thromboglobulin level did not hold true for the heparin-coated circuit group. CONCLUSIONS: A heparin-coated cardiopulmonary bypass surface reduces the blood activation potential during cardiopulmonary bypass, and the centrifugal pump causes less hemolysis than the roller pump.