PubMed HealthSearch

SEARCH · PubMed Health

Results for “Computer Terminals”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12Linked to original sources

[Pregnancy in women working on video terminal units].

Only a small proportion of pregnancy failures could be explained by simple genetic or clear--cut environmental/occupational factors. Adverse reproductive outcomes (spontaneous abortion, preterm delivery, low birth weight and congenital malformations), have been reported in a certain number of retrospective studies which were designed to examine the possible role of occupation and working or living conditions and pregnancy outcome. Future prospective projects should assess the (non)existence of the relationship between radiological risks and job stress with pregnancy outcome. Future prospective projects should assess the (non)existence of the relationship between radiological risks and job stress with pregnancy outcome among female video terminal operators.

Abortion, Spontaneous

Computer-assisted 3D reconstruction of the terminal branches of the cerebral arteries. I. Anterior cerebral artery.

We present a three-dimensional anatomical computer model of the terminal branches of the anterior cerebral artery, acquired from equidistant serial anatomical slices of three brains. The reconstructions provide a clear picture from all angles of the complicated course of the terminal branches of the cerebral arteries, which can help to identify them on conventional and magnetic resonance angiography. Our rendition of the cerebral arteries can also be matched with CT, MR or PET images to indicate the areas of extension of individual branches, allowing neuromorphological and functional correlations.

Adult

Computer-assisted 3D reconstruction of the terminal branches of the cerebral arteries. II. Middle cerebral artery.

We present a three-dimensional anatomical computer model of the terminal branches of the middle cerebral artery, acquired from equidistant serial anatomical slices of three brains. The reconstructions provide a clear picture from all angles of the complicated course of the terminal branches of the cerebral arteries, which can help to identify them on conventional angiography and magnetic resonance angiography. The arteries can also be matched with CT, MR or PET images to indicate the areas of extension of individual branches, allowing neuromorphological and functional correlations.

Adult

Construction of parametric model of operator and workstation.

The purpose of development of a parametric model and the construction and formulation of the parametric model are described. To validate the parametric model, the distribution of the difference between the preferred and theoretical seat height settings of a number of office workers was evaluated from the standpoint of the static posture that does not change with time. The results of precise measurements made for an engineering workstation and an operator were also evaluated. Finally, the theoretical seat height settings with dynamic posture were evaluated. The validity of the parametric model was verified under the experimental conditions.

Algorithms

Visual design for the user interface, Part 2: Graphics in the interface.

Highly interactive multimedia electronic documents pose unique graphic information design problems. This paper is a discussion of some of the graphic design considerations that are unique to electronic documents, including the challenges of adapting existing graphic design skills to electronic documents that are displayed and read from computer screens.

Computer Graphics

Preferred viewing distances for handheld and structurally fixed displays.

This research was conducted to define viewing distance characteristics of individuals engaged in ordinary reading tasks. Specific attention was directed to assessing the potential relationship between observed distance and individual resting point accommodation. Consistent, statistically significant differences were observed across variable handheld and structurally-fixed hardcopy display configuration conditions. Relationships between observed viewing distance and resting point accommodation were not apparent. These findings suggest that simple eye-to-display viewing distance is fundamentally different for handheld text presentations and for the same text presented in a configuration similar to that of a video display terminal.

Accommodation, Ocular

Detection of interstitial lung abnormalities on picture archive and communication system video monitors.

The purpose of this study was to compare the detection of interstitial lung abnormalities on video display workstation monitors between radiologists experienced with video image interpretation and radiologists who lack this experience. Twenty-four patients with interstitial lung abnormalities documented by high-resolution computed tomography (HRCT) and lung biopsy, and 26 control patients with no history of pulmonary disease or a normal HRCT and normal chest radiographs were studied. Images were acquired using storage phosphor digital radiography and displayed on 1,640 x 2,048 pixel resolution video monitors. Five board-certified radiologists evaluated the images in a blinded and randomized manner by using a six-point presence of abnormality grading scale. Three radiologists were from 1 to 4 years out of residency and considered to be experienced workstation monitor readers with between 1 to 3 years of video monitor image interpretation. For the inexperienced readers, one radiologist had no prior experience with reading images from a video monitor and was direct out of residency, and the other radiologist had less than 4 months of intermittent exposure and was 1 year out of residency. Sensitivity and specificity were determined for individual readers. Positive predictive values, negative predictive values, accuracy, and receiver-operating curves were also generated. A comparison was made between experienced and inexperienced readers. For readers experienced with video monitor image interpretation, the sensitivity ranged from 87.5% to 92%, specificity from 69% to 92%, positive predictive value (PPV) from 73% to 87.5%, negative predictive value (NPV) from 87% to 90%, and accuracy from 80% to 88%. For inexperienced readers, these values were sensitivity 58%, specificity 50% to 65%, PPV 52% to 61%, NPV 56.5% to 63%, and accuracy 54% to 62%. Comparing image interpretation between experienced and inexperienced readers, there were statistically significant differences for sensitivity (P < .01), specificity (P < .01), PPV (P < .05), NPV (P < .05), accuracy (P < .05), and area under the receiver operator curve (Az) (P < .01). Within the respective experienced and inexperienced groups, no statistical significant differences were present. Our results show that digitally acquired chest radiographs displayed on high-resolution workstation monitors are adequate for the detection of interstitial lung abnormalities when the images are interpreted by radiologists experienced with video image interpretation. Radiologists inexperienced with video monitor image interpretation, however, cannot reliably interpret images for the detection of interstitial lung abnormalities.

Adult

A method of measuring fingertip loading during keyboard use.

A single keycap on a standard alphanumeric computer keyboard was instrumented with a piezoelectric load cell and the fingertip motion was recorded with a high-speed video motion analysis system. Contact force histories between the fingertip and the keycap were recorded while four subjects typed a standard text for five minutes. Each keystroke force history is characterized by three distinct phases: (I) keyswitch compression, (II) finger impact and (III) fingertip pulp compression and release. Each keystroke force history contained two relative maxima, one in phase II and one in phase III. The subject mean peak forces ranged from 1.6 to 5.3 N and the subject mean peak fingertip velocities ranged from 0.3 to 0.7 m/s. Motion analyses and force measurements suggest a ballistic model of finger motion during typing.

Computer Terminals

Obstacles encountered in the development of the low vision enhancement system.

The Johns Hopkins Wilmer Eye Institute and the NASA Stennis Space Center are collaborating on the development of a new high technology low vision aid called the Low Vision Enhancement System (LVES). The LVES consists of a binocular head-mounted video display system, video cameras mounted on the head-mounted display, and real-time video image processing in a system package that is battery powered and portable. Through a phased development approach, several generations of the LVES can be made available to the patient in a timely fashion. This paper describes the LVES project with major emphasis on technical problems encountered or anticipated during the development process.

Audiovisual Aids

On-line computer processing of pressure data from cardiac catheterizations.

A flexible program system for on-line analysis of pressure data from cardiac catheterizations is described. The programs are implemented on an IBM 1800 computer, equipped with remote oscilloscope/keyboard terminals. The current computer system can handle any combination of up to 4 pressure signals. During catheterization, measurement specifications (i.e. calibration levels or sites of pressure recordings) are entered via the keyboard immediately before each recording. As an option the whole expected measurement sequence may be stored on disk before the catheterization starts. This method will minimize the necessary interaction with the computer when the same catheterization procedure is used on several occasions. Changes from the predetermined scheme may, however, be undertaken before each recording to meet with unexpected events that may arise during the catheterization. After computer detection of calibration levels, the recorded signals are digitized during 20 seconds and analysed beat-by-beat. Calculated values are averaged and presented on the terminal oscilloscope in tabular and/or graphic form. The waveform analysis performed by the program system is validated in a statistical comparison between manually and automatically computed values.

Cardiac Catheterization