PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Denture, Partial, Fixed”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12Linked to original sources

Retrospective evaluation of complete-arch fixed partial dentures connecting teeth and implant abutments in patients with normal and reduced periodontal support.

STATEMENT OF PROBLEM: The clinical outcome of complete-arch fixed prostheses supported by implants and natural tooth abutments in patients with normal or reduced periodontal support has been reported by few studies, with controversial results. PURPOSE: The purpose of this study was to report on the implant success rate, prosthetic complications, and the occurrence of tooth intrusion, when complete-arch fixed prostheses, supported by a combination of implants and teeth, were fabricated for patients with normal and reduced periodontal support. MATERIAL AND METHODS: Nineteen patients with residual teeth that served as abutments were consecutively treated with combined tooth- and implant-supported complete-arch fixed prostheses and were retrospectively evaluated after a period varying from 24 to 94 months. Nine patients showed reduced periodontal support as a result of periodontal disease and treatment (RPS group), and 10 patients had normal periodontal support of the abutment teeth (more than 2/3 of periodontal support [NPS group]). Ninety implants and 72 tooth abutments were used to support 19 fixed partial dentures. Screw- and cement-retained metal-ceramic and metal-resin prostheses were fabricated with rigid and nonrigid connectors. Implant survival and success rates, occurrence of caries and tooth intrusion, and prosthetic complications were recorded. The number of teeth, implants, prosthetic units, fixed partial dentures, and nonrigid connectors were compared with a t test to assess differences between the 2 groups, while data for the occurrence of intrusions and prosthetic complications were compared with the Fisher exact test (alpha=.05). RESULTS: One of the 90 implants was lost (99% survival rate) over 24 to 94 months, while 3 implants showed more than 2 mm of crestal bone loss (96% success rate) over the same period. No caries were detected, but 5.6% (4/72) of the abutment teeth exhibited intrusion. Intrusion of abutment teeth was noted in 3 patients who had normal periodontal support (13% of teeth in NPS group) of the abutment teeth and was associated with nonrigid connectors. No intrusion of teeth was noted in the patients exhibiting reduced periodontal support regardless of the type of connector or when a rigid connector was used for either group. The number of intruded teeth was significantly greater in patients with intact periodontal support (P=.03). CONCLUSIONS: Complete-arch fixed prosthesis supported by implant and tooth abutments may be associated with intrusion of teeth with intact periodontal support when nonrigid connectors are used to join the implant- and tooth-supported sections of the prostheses. However, fixed partial dentures supported by implants and teeth with reduced periodontal support were not associated with tooth intrusion, regardless of the type of connectors used.

Adult↗

Long-term observations of extensive fixed partial dentures on mandibular canine teeth.

Twelve patients were followed for 15 years after treatment with a 12-unit cantilever fixed partial denture on the mandibular canines opposite to a complete maxillary denture. Four constructions failed and had to be removed but four were still in function after 15 years. Four patients died during the observation period still wearing their constructions. Endodontic complications, pulpal necrosis and loss of retention of posts were the most frequent, while caries and periodontal lesions were rare. The maintenance costs over the years were fairly low even compared to maintenance costs for patients treated with implants. Extensive mandibular cantilever fixed partial dentures may be used in the rehabilitation of patients with a very reduced dentition and a history of difficulties adapting to removable dentures.

Adult↗

Influence of water storage and thermal cycling on the fracture strength of all-porcelain, resin-bonded fixed partial dentures.

The purpose of this in vitro study was to evaluate the influence of water storage and thermal cycling on the fracture strength of two designs of all-porcelain, resin-bonded fixed partial dentures made with the glass-infiltrated alumina ceramic In-Ceram. Forty frameworks of In-Ceram ceramic veneered with Vitadur-N porcelain were made to replace an upper central incisor bonded to extracted natural teeth. In 20 of the restorations the pontic was veneered only labially with Vitadur-N porcelain and no proximal box preparations were made (design A). The other 20 restorations had additional box preparations proximal to the pontic and the In-Ceram ceramic pontic framework was shifted to the labial aspect and veneered circumferentially with Vitadur-N porcelain (design B). Subgroups of 10 restorations were stored for 7 days in thymol solution or alternatively for 150 days in artificial saliva with thermal cycling for 18,750 cycles between 5 degrees and 55 degrees C. Restorations with design B had a statistically significantly higher fracture strength than restorations with design A. Storage in artificial saliva with thermal cycling significantly reduced the fracture strength of the resin-bonded In-Ceram fixed partial dentures. Therefore, the long-term clinical behavior of resin-bonded In-Ceram fixed partial dentures must be evaluated before general clinical use can be recommended.

Aluminum Oxide↗

The use of a dental implant as an abutment in three unit implant-tooth supported fixed partial denture: a case report and 32 month follow-up.

The combined use of dental implants and teeth as abutments in fixed partial dentures may offer advantages to both patients and practitioners in certain clinical situations. An implant-tooth retained prosthesis may reduce surgical intervention and cost to the patient. It may also mean that anatomical restrictions to the provision of an implant-retained fixed prosthesis may be overcome. In this case report, the steps in provision of a three unit implant-to-tooth fixed partial denture are described and the treatment planning and prognosis of a restoration of this type are discussed.

Dental Abutments↗

[A photoelastic study of the stress distribution in the surrounding tissues of the abutments of a fixed partial denture with tilted molar abutments].

The purpose of this study was to evaluate the stress distributions to the abutments of a fixed partial denture with tilted molar abutments. In cases of the lower 1st molar being missing four 2-dimensional photoelastic models with 3- unit fixed partial dentures of which the 2nd molars were tilted 0 degrees, 10 degrees, 20 degrees and 30 degrees toward the 2nd premolar were made. A vertical load of 50 lbs was applied to the 1st and 2nd molar in each case. Two-dimensional photoelastic stress analysis was used, and the stress areas were recorded photographically. The results were as follows; 1. When the vertical load was applied to pontic and 2nd molar on the central fossae, the magnitude of stress distribution of the surrounding tissues of the root of the 2nd premolar was increased incrementally with increasing inclination. 2. Under two loading conditions, the stress distributions were directed to the long axis of the abutments. 3. In this experiment, no stress distributions were observed on the mesial area of the mesial root of the second molar.

Dental Abutments↗

In vitro strain gauge analysis of axial and off-axial loading on implant supported fixed partial dentures.

The purpose of this study was to compare the in vitro strains on dental implants supporting cement-retained fixed partial dentures under axial and off-axial loading conditions. Ten implants incorporating strain gauges were placed in a certain configuration to simulate different clinical situations and were embedded in an experimental model. Two implant supported three-unit fixed partial dentures were fabricated on four groups of implants, and each group consisted of seven restorations. The prostheses were cemented with a temporary cement. Fifty N vertical load was applied on predetermined axial and off-axial loading locations on the prostheses. Strain indicator readings were recorded at a standardized time following each loading sequence. The point of load transfer affected strains on implants. For all prosthetic designs, off-axial loading generated more strain than axial loading on implants (P < 0.05). In comparison with axial loading, off-axial loading causes bending of the implants that may affect bone loss around the implant collar. Axial loading of implants should be provided by using wide diameter implants, narrow occlusal tables, and proper occlusal contacts on implant restorations.

Analysis of Variance↗

Occlusal force pattern during mastication in dentitions with mandibular fixed partial dentures supported on osseointegrated implants.

The occlusal force pattern during chewing and biting was studied in eight edentulous patients whose dentitions had been restored with mandibular bilateral posterior two-unit cantilever fixed prostheses supported on osseointegrated titanium fixtures and occluding with complete maxillary dentures. The chewing pattern was comparable to that reported for subjects with complete healthy dentitions or with tooth-supported cross-arch fixed partial dentures. However, during chewing and swallowing the voluntary capacity of the jaw-closing muscles was used to a much greater extent. Contrary to reports for cantilevers in tooth-supported cross-arch unilateral posterior two-unit cantilever fixed partial dentures occluding with natural teeth, the posterior cantilever segments in the present fixture-supported cantilever prostheses occluding with complete dentures regularly exhibited the largest local forces. Despite this, material failures of this type of fixed prostheses are rare, as demonstrated in long-term follow-up studies.

Adult↗

Alternative method for connecting a removable gingival extension and fixed partial denture: a clinical report.

In terms of esthetics and hygiene, defects in the alveolar ridge can complicate the design and fabrication of fixed partial dentures. When missing anterior teeth are restored, it may be difficult to achieve a satisfactory appearance without the correction of soft tissue and alveolar defects. When surgical intervention is not an option, a removable gingival extension and fixed prosthesis may be considered. This clinical report describes the use of a custom-made pin system (rather than intra- or extra-coronal attachments) to esthetically connect a removable gingival extension to a fixed partial denture.

Acrylic Resins↗

Three-year clinical evaluation of fiber-reinforced composite fixed partial dentures using prefabricated pontics.

PURPOSE: The purpose of this study was to evaluate the clinical performance of surface-retained adhesive composite fixed partial dentures reinforced by an ultra-high molecular weight polyethylene (UHMWP) fiber (Ribbond THM). MATERIALS AND METHODS: Twenty-three surface-retained fiber reinforced composite (FRC) fixed partial dentures (FPD) were placed by two operators in 23 patients, each with a single missing tooth. The restorations included prefabricated composite resin pontics, and no preparations were done on the lingual surfaces of the abutment teeth. The patients were recalled for examinations every year for up to 3 years. Restorations were evaluated directly using the modified Ryge criteria. The minimum observation period was 1 year and the maximum observation period was 3 years. RESULTS: At baseline, 23 restorations were graded as Alpha for all parameters. At one year and two years (n = 21), three Bravos for wear resistance and surface texture/gingival inflammation and two Bravos for color match were observed. Twenty-one of 23 restorations were retained at the end of two years (91.3%) and 78.3% were retained after a maximum of 3 years. CONCLUSION: The results of this clinical study suggestthat UHMWP FRC FPDs are quite acceptable at least forthree years. However, further clinical investigations are still needed for improved long-term clinical performance.

Adolescent↗

Resin-bonded fixed partial dentures and splints in periodontally compromised patients: a 10-year follow-up.

In the present study, 139 periodontally compromised patients received a complete periodontal treatment; in 104 cases this was followed by orthodontic treatment. At the end of the entire therapy, a total of 150 Maryland restorations (69 resin-bonded fixed partial dentures and 81 resin-bonded splints) was placed and then followed for a period of up to 10 years (mean 6.7 y). Thirteen fixed partial dentures and 16 splints failed during the observation period; the 10-year cumulative survival rate from lifetable analysis was 76.2% (70.6% for fixed partial dentures and 80.7% for splints).

Adult↗

Two-dimensional photoelastic simulation of a castable ceramic fixed partial denture.

Two-dimensional photoelastic models were used to determine the optimum design and loading conditions for a three-unit castable ceramic fixed partial denture. Findings relating to design and material variables can be summarized as follows. 1. Higher modulus cements impart more rigidity to the fixed partial denture design and result in lower stresses. 2. A short connector results in higher stress than a long connector; however, the length of the connector should not exceed one half the mesial-to-distal length of the pontic. 3. An intermediate thickness of cement results in the best stress distribution. 4. The male connector is best attached to the bulkier abutment. 5. Occlusal cement eccentricity is less desirable than cervical eccentricity. 6. The most undesirable loading site is directly above the connector.

Dental Stress Analysis↗

Twenty-year experience with 12-unit fixed partial dentures supported by two abutments.

Eleven patients who had only two remaining natural teeth, vital mandibular canines, were treated using experimental 12-unit fixed partial dentures and complete maxillary dentures. The marginal bone support was 60% in one patient and 80% to 100% in the others. The patients were studied for 20 years. After 15 years, seven patients had prostheses that were still functional, two had prostheses that failed, one lost the prosthesis following treatment for oral cancer, and one patient died. Nine of the 22 abutments required endodontic treatment. After 15 years, the fixed partial dentures began to tilt distally and considerable resorption was found under the pontics. The periodontal tissues withstood the increased stress, and the prostheses were stable.

Adult↗

Retrofitting an esthetic post and core to salvage a six-unit fixed partial denture.

Teeth restored with post and core restorations present a clinical dilemma if they fracture. An individual with a maxillary anterior six-unit fixed partial denture had one of the canine abutment teeth fracture. The other abutment debonded and the post separated from the core. The fixed partial denture was salvaged by retrofitting a porcelain-fused-to-metal post and core restoration in the fractured abutment.

Cuspid↗

Tooth structure loss apical to preparations for fixed partial dentures when using self-limiting burs.

STATEMENT OF PROBLEM: Burs with guide pins may be used to limit the depth of tooth preparation for fixed partial dentures. The effects of guide pins on tooth structure apical to the finish line after tooth preparation for fixed partial dentures has not been recorded. PURPOSE: This in vitro study recorded loss of tooth structure within 1.0 mm apical to the finish line of teeth prepared with straight cylinder and tapered cylinder self-limiting burs and one conventional bur. MATERIAL AND METHODS: Forty-five extracted human teeth were randomly divided into three groups. The facial surface of each tooth was prepared with two types of diamond burs with guide pins and a conventional diamond for the control. The surface was profiled before and after tooth preparation. Profiled surfaces were analyzed and the groups were compared using analysis of variance and the Tukey-Kramer HSD test (alpha = 0.05). RESULTS: No significant difference was recorded between the control group and the group prepared with a round-ended tapered cylinder self-limiting pin. However, there was a statistically significant difference between the control and cylindrical pin groups, and between the two groups prepared with self-limiting diamonds. CONCLUSION: This study revealed abrasion apical to the finish line of the preparation in all groups. The cylindrical guide pin group exhibited the greatest loss of tooth surface.

Analysis of Variance↗

Stress analysis of a cantilevered fixed partial denture with normal and reduced bone support.

A two-dimensional finite element model was constructed to analyze the simulated mechanical behavior of a cantilevered fixed partial denture. The variations of the models were made by altering the degree of bone support, the number of splinted abutments, and the length of the pontics. High stress concentrations were observed around the connectors of the fixed prosthesis and the tooth closest to the cantilever. Reduced bone support increased the deflection and stress concentrations. There was reduction in displacement and stress concentration when the teeth were splinted together. To improve the prognosis of the fixed partial denture cantilever, the number of abutments should be increased and the number of pontics decreased.

Alveolar Bone Loss↗

Stress concentration in all-ceramic posterior fixed partial dentures.

Two-dimensional finite-element analysis was used to study levels and distribution patterns of stress within three-unit fixed partial dentures (mandibular first premolar to first molar) constructed of different materials (Type III gold alloy, Dicor, and In-Ceram) and with different connector heights (3.0 mm versus 4.0 mm). In the computer models, 10 MPa of stress was applied centrally to the prosthesis. Resultant von Mises stresses were concentrated within the connectors; the greatest stress occurred at the axial location of the connector. Stresses were 40% to 50% lower for 4.0-mm connectors. Patterns of stress distribution were similar for premolar and molar connectors. Stress levels within In-Ceram models were lower than for the other two materials and represented a lower percentage of the ultimate strength of the material. Based on a two-dimensional finite-element analysis model, In-Ceram would appear to be the best choice for posterior fixed partial dentures.

Aluminum Oxide↗

Treatment of a juvenile patient with a maxillary all-ceramic resin-bonded fixed partial denture: a case report.

Treatment of juvenile patients with a missing maxillary incisor is difficult, because an implant cannot be placed until growth is completed. The other minimally invasive alternatives are also problematic: Removable dentures are rarely accepted by juvenile patients, and the conventional resin-bonded fixed partial denture often provides a poor esthetic result because the metal retainer causes the abutment teeth to lose their natural translucency and to become grayish. Moreover, the alveolar ridge defect makes it easy to identify the prosthesis in the pontic area. The present case report describes the prosthetic treatment of a juvenile patient who had lost a maxillary incisor to trauma. To avoid the disadvantages of conventional therapies, subepithelial connective tissue was grafted to reshape the alveolar ridge. The space was closed with an all-ceramic resin-bonded fixed partial denture.

Adolescent↗