PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Device Removal”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12Linked to original sources

Complications of removing percutaneous endoscopic gastrostomy tubes in children.

BACKGROUND: Little information has been reported regarding the frequency and type of complications arising from removal of percutaneous endoscopic gastrostomy (PEG) tubes in children. METHODS: The records of 397 patients who had PEG tubes placed from 1993 through 1998 were reviewed for complications after removal. Data collected included length of time the tube was in place, age of the patient at insertion, type of tube removed, and patient diagnosis. RESULTS: Fifty-four children had the PEG tube removed by traction or endoscopy. The only complication was persistent leaking through a gastrocutaneous fistula in 13 patients (24%). Leaking ceased in 6 children coincident with H2-antagonist therapy and silver nitrate cautery, and surgical closure of the fistula was required in 7 patients. Comparison of these 7 children with those who did not require surgery (n = 47) showed a longer duration of tube placement (mean +/- SE of 20.6+/-3.6 months, range 11-31 months vs. 11.1+/-1.3 months, range 1-35 months; P<0.05). Further analysis showed no child with a PEG tube removed before 11 months (n = 23) after insertion required surgery, whereas 7 (23%) of 31 children with a PEG tube removed after 11 or more months required surgery. Age at insertion, type of feeding device removed, and patient diagnoses were not different between the two groups. CONCLUSIONS: These data indicate that persistent leaking necessitating surgical closure of a gastrocutaneous fistula does not occur in children with a PEG tube removed within 11 months of insertion. In contrast, 23% of children with a PEG tube removed 11 or more months after insertion require surgery. In patients identified as candidates for tube removal, this time frame may be important in clinical decision making.

Child, Preschool↗

Deep wound infection after vagus nerve stimulator implantation: treatment without removal of the device.

Effective treatment of deep wound infection without removal of a previously implanted foreign body is difficult. The Neurocybernetic Prosthesis (NCP) System (Cyberonics Inc., Webster, TX, U.S.A.), implanted for vagus nerve stimulation in patients with medically refractory epilepsy, uses coil-like electrodes placed around the left vagus nerve after exposure of the nerve in the carotid sheath. Infection within this compartment endangers the contained structures and makes removal of the system hazardous. We report the case of one patient implanted with the NCP who underwent successful open wound treatment without removal of the system. A 35-year-old man had local signs of wound infection 5 weeks after implantation of a vagus nerve stimulator. Systemic signs of infection were absent. C-reactive protein was slightly elevated, but all other laboratory values were normal. After open wound debridement and thorough rinsing with bacitracin-containing solution, the wound was packed with 3% iodoformized gauze. The NCP was left in place. Systemic antibiotic therapy with fosfomycin and cefmenoxim was started. Cultures confirmed an infection with Staphylococcus aureus. The wound was rinsed daily with 3% hydrogen peroxide solution and 5% saline until cultures were sterile and granulation tissue started to fill the wound. Delayed primary closure was performed 2 weeks later. Wound healing was accomplished without removal of the device. No signs of recurrent infection were observed during a follow-up of 1 year. Open wound treatment without removal of the implanted vagus nerve stimulator is feasible in cases of deep cervical wound infection and can be an alternative if removal of the device appears hazardous.

Adult↗

Intracardiac echocardiography to guide closure of atrial septal defects in children less than 15 kilograms.

BACKGROUND: Intracardiac echocardiography (ICE) is increasingly replacing transesophageal echocardiography (TEE) as the primary imaging technique to guide device closure of atrial septal defects (ASD). Owing to the length of the procedure, the use of TEE requires general anesthesia. Investigators have reported the usefulness of ICE in adults and children. However, little is known about the use of ICE in children whose weight is <15 kg. Therefore, this study examines the use of ICE guided secundum ASD closure in children <15 kg. METHODS: Nineteen patients with a median age of 3.1 years (range 1.8-4.8), and median weight of 13.2 kg (range 8.0-14.4) underwent transcatheter occlusion (Amplatzer occluder) of a secundum ASD using ICE guidance. ICE was performed using an Acunav catheter. The ICE catheter (10 F shaft) was introduced into an 11 F sheath in a contralateral femoral vein. Diagnostic as well as periprocedure imaging was obtained. RESULTS: Sixteen patients had single, and three had multiple defects. Median defect size as measured by ICE was 16 mm (range 2.5-25). The median balloon stretched diameter (obtained in eight patients) was 18 mm (range 10-21); the median size of the defect for these eight patients was 15 mm (range of 8-20). Both techniques for measuring the defect correlated well with r = 0.94. The ASD occluder size ranged from 7 to 26 mm with a median of 18 mm. The procedure was successful in 16 patients who had a device implanted and no residual shunt. ASD occlusion was not attempted in two patients due to deficient rims and in one patient, the attempt failed due to left atrial disk prolapse through the ASD. Four patients experienced transient complications during the catheter procedure, including supra ventricular tachycardia, sinus bradycardia, and two with complete heart block (resolving with device removal); all had subsequent successful device placement. No complications were attributed to the use of ICE and specifically, no vascular injury was noted. CONCLUSIONS: Comparable to results with larger patients, ICE provides adequate imaging (preprocedure diagnosis and periprocedure guidance) during device occlusion of secundum ASDs with no significant complications. Thus, ICE can successfully be used in the closure of ASD in smaller patients (<15 kg) and eliminate the need for endotracheal intubation.

Body Weight↗

Implantable LVAD infections: implications for permanent use of the device.

BACKGROUND: Infection in implantable left ventricular assist device (LVAD) patients is common and has serious implications regarding permanent use of the LVAD. METHODS: Thirty-three patients had HeartMate LVAD insertion as a bridge to heart transplantation. The mean length of hospital stay was 8 days before LVAD insertion. Before insertion 6 patients (18%) had positive pulmonary cultures and 5 patients (15%) had bacteremia. RESULTS: During LVAD support 18 patients (55%) had bloodstream infection. Of 24 patients (73%) successfully bridged to transplantation, 12 (50%) had positive blood cultures including Staphylococcus species (n = 9), Candida (n = 3), Pseudomonas (n = 2), and Enterococcus (n = 2). Infectious complications encountered in this series included driveline infection requiring surgical revision, septic embolus, "cleared" device infection, "suppressed" device infection, and LVAD infection treated by device removal in 1 patient and device exchange in another. CONCLUSIONS: Infection in implantable LVAD patients is common, especially in patients in whom multiple organ failure develops, requiring prolonged stay in the intensive care unit. Strategies are needed to prevent these infections in recipients of the permanent LVADs because treatment of an established infection is difficult and expensive.

Adult↗

Successful treatment of diabetes with the biohybrid artificial pancreas in dogs.

We have investigated a new hybrid artificial pancreas device to transplant islet allografts without immunosuppression. The device consists of a chamber through which passes a copolymer membrane connected to standard vascular grafts. Islets are placed inside the chamber but are outside of the blood stream. Nominal molecular porosity of 80,000 daltons permits free diffusion of nutrients and insulin across the membrane but inhibits the entry of immunoglobulins and immunocytes from the blood stream into the chamber. Initial studies focused on the technical feasibility of implanting the unseeded (no islets) devices. In 12 normal mongrel dogs, the arterial limb of the device was anastomosed end-to-end to the common iliac artery and the venous limb end-to-side to the common iliac vein. Vascular patency was monitored by an audible bruit over the device. Two devices currently remain patent at 388 and 421 days. The remaining experiments failed due to thrombosis and membrane rupture, with 2 failing as late as 170 and 279 days. In a second series, both arterial and venous anastomoses were done end-to-side and dogs were placed on low-dose aspirin therapy. All 8 dogs are currently maintaining patent unseeded devices (96-226 days postimplantation). Subsequent studies determined the function of devices seeded with isolated canine pancreatic islet allografts in totally pancreatectomized, severely diabetic dogs. Diabetes was controlled by once-a-day insulin injection. After 2-3 weeks of diabetic control, a seeded device was implanted. Diabetic control was monitored by fasting blood levels and postprandial and intravenous glucose tolerance tests, and vascular patency by the loudness of the bruit. In the first series of 6 dogs given seeded devices without aspirin, no significant function was discernible, with failure attributable to thrombosis, poor islet viability, and surgical complications. In the second series of 13 dogs given aspirin, 8 dogs have required an appreciably lower dose of injected insulin to maintain fasting blood glucose at acceptable levels. Of note are 4 dogs that required virtually no exogenous insulin for at least 3 weeks. One dog lost function on day 74 and another still requires no insulin at 267 days postimplantation. However, despite normal fasting glucose levels, the glucose tolerance tests showed delayed return to normal levels. Weight lost following pancreatectomy was rapidly regained in the presence of a functioning seeded device. Histologic examination of the removed devices revealed no signs of rejection.

Animals↗

Percutaneous snare retrieval of a partially embedded Wallstent.

Although removal of a stent is a well described method for treating an acutely dislodged or embolized device, removal of a previously deployed stent is unusual. We describe a case where a partially dislodged wallstent in a saphenous vein graft was removed using a snare to permit deployment of a balloon mounted stent across a proximal vein graft stenosis.

Aged↗

Re-insertion of a progesterone-containing intravaginal device to synchronise returns to oestrus in dairy heifers.

Recommendations for oestrus synchronisation of dairy heifers using progesterone-containing intravaginal devices suggest re-insertion of used devices 16 days after first insemination for a period of 5 days to allow a second opportunity for artificial insemination. Controlled studies on the effectiveness of re-using intravaginal devices to synchronise returns to oestrus in non-pregnant dairy heifers are lacking. A clinical trial was conducted involving 750 Friesian heifers in 13 herds. After an initial synchronisation programme, the used intravaginal devices were re-inserted 14 or 16 days after first insemination into half of the heifers in each herd for a period of 5 days. After the first synchronisation programme, 47.5% of heifers remained non-pregnant. Re-insertion of used intravaginal devices for 5 days significantly increased the number of non-pregnant heifers detected in oestrus and inseminated by 48 hours after device removal compared to heifers in which devices were not re-inserted (45.2% v. 27.3%, p < 0.05, in herds where intravaginal devices were re-inserted on day 14; 48.8% v. 13.6%, p < 0.05, in herds where intravaginal devices were re-inserted on day 16). Re-insertion at 14 or 16 days after first insemination was equally effective in increasing visible returns to service. However, the number of non-pregnant heifers synchronised for a second round of artificial insemination was less than expected. Conception rate to the re-synchronised oestrus was unaffected by the treatment. It is concluded that the additional procedures of CIDR re-insertion, removal, tailpainting and insemination involved in there-synchrony programme, and the relatively low in-calf rate to the re-synchronised round of insemination, reduced the potential benefits of re-synchronisation.

Journal Article↗

An assessment of the use of Implanon in three community services.

AIMS: The aims of the study were three-fold, namely to assess continuation rates with Implanon fitted in clients from three contraception and sexual health services; to identify factors associated with early removal of Implanon; and to assess clinician compliance with recommended practice in counselling and insertion. METHODS: Retrospective review of client records, and comparison with audit criteria. Postal survey. MAIN FINDINGS: One hundred and ninety women had Implanon inserted in the study period. Continuation rates were between 84% and 88% at 6 months and 67% and 78% at 12 months. There were no pregnancies or procedure complications. The main reasons for removal were identified as intolerance of recognised side effects or a change of mind about wanting contraception. Younger women were more likely to have the device removed early. There was evidence of excellent or good recording of many criteria for best practice in counselling and insertion. The assessment highlighted certain issues around counselling and insertion that services needed to consider further. CONCLUSIONS: The three services have been reassured that they are providing a good standard of care to clients requesting Implanon and that their 'real life' 6- and 12-month continuation rates are reasonable.

Adolescent↗

Successful management of an infected implantable cardioverter defibrillator with oral antibiotics and without removal of the device.

Infection of an implantable cardioverter defibrillator developed 2 weeks after implantation, presenting with fever, swelling, redness, and tenderness of the skin above the generator site. A cloxacillin resistant coagulase-negative staphylococcus was repeatedly cultured from the abdominal wall pocket fluid. The infection was successfully treated with a combination of two antibiotics, fusidic acid and rifampin, given orally for 3 months. Although the device was not removed, infection did not recur during a 24-month follow-up.

Administration, Oral↗

Two years of intrauterine contraception with levonorgestrel and with copper: a randomized comparison of the TCu 380Ag and levonorgestrel 20 mcg/day devices.

IUDs releasing 20 mcg/day of levonorgestrel (LNg20) were in randomized trial together with the Copper T, model TCu 380Ag, in seven centers involving 2244 women. Two-year (25 months) gross cumulative pregnancy rates were 0.2 +/- 0.2 and 0.9 +/- 0.3 for the levonorgestrel and copper releasing devices, respectively (P greater than 0.05). There were no ectopic pregnancies in more than 1600 woman-years of use of each device. Removal rates for bleeding and/or pain or for medical reasons other than menstrual problems did not differ significantly between devices. Oligomenorrhea or amenorrhea prompted 10.7 per hundred (gross rate, 8.4 net rate) women using the LNg 20 IUD to request removal in the two-year period, significantly above the 0.2 per hundred rate among women with the Copper IUD (P less than 0.001). At the end of two years an estimated 59.4 per 100 women were continuing use of the LNg 20 IUD, and 67.5 per 100 (P less than 0.001) with the TCu 380Ag. This difference is almost wholly ascribable to a marked reduction in bleeding episodes and days among women using the LNg 20 device with concomitant removal of device. Hemoglobin rose an average of 0.5 g/dl (P less than 0.001) for this group whereas women using the TCu 380Ag experienced a decline of 0.2 g/dl compared with baseline values (P less than 0.001).

Adolescent↗

The "chewing wheel" device: plaque-removing efficiency and use in oral hygiene programs.

Control of bacterial plaque on tooth surfaces is the most important method of controlling dental disease. The patient's ability to achieve good plaque control is of utmost importance in preventing the occurrence of periodontal disease and in maintaining periodontal health. The search for better methods that enable easier and more effective plaque control has led to the development of the "chewing wheel." A clinical trial was conducted to compare the plaque-removing efficiency of the chewing wheel to that of a manual toothbrush. The tested device removed 18% to 37% of the accumulated dental deposits. In spite of its limited efficiency, the wheel can be used as part of an oral hygiene program for individuals with perceptomotor dysfunctions.

Adult↗

Vagal nerve stimulator pocket infections.

Vagal nerve stimulator pocket infections are uncommon but can cause considerable morbidity. We describe 3 children from our institution and 8 others previously reported with infection after vagal nerve stimulator implantation for seizure control. Infection was suppressed but recurred despite appropriate antimicrobial therapy when the device remained in situ. Device removal was required in all patients to achieve cure.

Anti-Bacterial Agents↗

Incidence of root fractures and methods used for post removal.

AIM: This study was undertaken to determine the incidence of root fractures during post removal, as well as the methods used and the success rates achieved with various post removal devices and techniques. METHODOLOGY: Patient records from a specialist endodontic practice were examined. A total of 1600 teeth from which posts were removed were identified. These teeth had no preoperative signs or symptoms to suggest root fractures. The incidence of root fractures was determined and a subset of 234 patient records were examined in detail to determine the methods used to remove different types of posts. RESULTS: Only one tooth fractured during post removal (0.06%) and all posts were successfully removed, typically in about 3 min. Most cast posts were removed with an Eggler post remover but some dislodged when the crown was removed; ultrasonics was used occasionally. Most parallel-sided posts were removed with ultrasonics and threaded posts were unscrewed. The Masserann kit and ultrasonics were combined to remove fractured cast posts and some parallel-sided posts. CONCLUSIONS: This study indicates that, with good case selection, post removal is a predictable procedure. If appropriate techniques and devices are used for the particular type of post being removed, then root fracture is a rare occurrence.

Cohort Studies↗

Infectious complications of implantable venous access devices in patients with sickle cell disease.

PURPOSE: To evaluate the incidence of implantable venous access device infection in patients with sickle cell disease. MATERIALS AND METHODS: The authors performed a retrospective search of their hospital's information system from January 1, 1996 to December 31, 2001 to identify hospital admissions with ICD-9 codes related to sickle cell anemia. This search yielded 2703 admissions in 293 patients. A search of the radiology information system identified 23 of these patients who had placement of an implantable venous access device. Excluding two patients who were lost to follow-up, the population of this study included eight men and 13 women aged 23 to 62 years old (mean, 37 years). A total of 30 implantable venous access devices (25 venous ports, five tunneled catheters) were placed by interventional radiologists. Cases of device infection were identified based on clinical data, microbiology, reports of device removal, and clinical follow-up. Infections were defined according to the Centers for Disease Control criteria for catheter-related bloodstream infection. The incidence of infection, organism, and time from device placement to infection was determined. RESULTS: In 21 patients with 30 devices, 18 device infections (60%) occurred in 12 patients (57%) involving 15 venous ports and three tunneled catheters. There were a total of 12389 days of catheter use and a rate of 1.5 infections per 1000 catheter days. Infections occurred from 16 to 1542 days (mean, 349 days) after device placement. Blood, wound, and catheter tip cultures yielded solitary organisms in 13 cases and mixed organisms in four cases. Staphylococcus aureus was the most common pathogen (59%). One patient was considered infected based on clinical signs and purulent discharge from the port site, despite negative cultures after partial antibiotic treatment. One patient died of sepsis resulting from an infected port. CONCLUSION: This study shows a high incidence of infection associated with placement of implantable venous access devices in patients with sickle cell disease. Therefore, the authors avoid placing these devices in this patient population.

Adult↗

Staphylococcus aureus bacteremia and endocarditis associated with a removable infected intravenous device.

Records of 21 patients with Staphylococcus aureus bacteremia associated with a removable infected intravenous device were reviewed. Sixteen patients had a peripheral intravenous catheter, four had a central venous catheter and one had a transvenous cardiac pacer. The duration of the indwelling intravenous device in situ prior to the detection of infection ranged from two to 11 (mean 5.2) days. The infected intravenous device was promptly removed as soon as bacteremia was suspected. Endocarditis was diagnosed in eight patients: in two patients an aortic murmur developed; in two the diagnosis was made clinically and was confirmed at necropsy (one mitral and one aortic); in four the diagnosis was made at necropsy (two tricuspid and two atrial wall). In patients with Staph. aureus bacteremia associated with a removable infected intravenous device, the risk of endocarditis developing was significant.

Adult↗

Uterine perforation by GyneFix frameless IUD: two case reports.

Two cases of uterine perforation are described, occurring 11 days and 4 months, respectively, after the insertion of GyneFix, a frameless intra-uterine contraceptive device (IUD). In both the cases initial ultrasound scan showed the intra-uterine position of the device. Removal of the IUD, either by laparoscopy or laparotomy, had to be carried out. Awareness of this complication, insertion of GyneFix by a trained operator, appropriateness of ultrasound scan monitoring and possible underreporting of this complication are discussed.

Adult↗

Chronic Pseudomonas infections of cochlear implants.

OBJECTIVE: To discuss chronic, refractory Pseudomonas infections of cochlear implants and their management. DESIGN: Retrospective case series. SETTING: Two university-based cochlear implant programs. PATIENTS: Twenty-eight-year-old (Case 1) and 4-year-old (Case 2), different devices. INTERVENTIONS: Medical and surgical management. MAIN OUTCOME MEASURES: Clinical course. RESULTS: Both patients had delayed presentations, 4 months and 3 years postimplantation, respectively, with fluctuating scalp edema and pain resistant to multiple courses of oral antibiotics. Infections began as localized granulation and progressed to complete encasement of both devices with rubbery, poorly vascularized tissue. In each case, two different strains of multiresistant Pseudomonas aeruginosa were cultured. Infections progressed despite local debridement and targeted antipseudomonal antibiotic coverage, and sensitive organisms continued to appear in cultures of refractory granulation tissue. Both patients underwent partial explantation, with the electrode array left in the cochlea, then received 2 to 3 more months of further medical therapy and observation and then were reimplanted successfully with new devices. Both have shown excellent performance and no sign of recurrent infection. CONCLUSIONS: Infections of cochlear implants are uncommon, and cases of successful conservative management without device explantation have been reported. However, our experience and the implanted device literature suggest that chronic Pseudomonas infections may represent a distinct clinical entity, likely to fail protracted therapy and ultimately require device removal. Fortunately, successful reimplantation is possible.

Adult↗

Internal craniofacial distraction with biodegradable devices: early stabilization and protected bone regeneration.

Internal craniofacial distraction has several advantages over distraction with external devices. The scars may be less conspicuous; the devices are buried and therefore easier for patients to tolerate; and the devices are more rigidly secured to bone, preventing uncontrolled rotation of the advancing segments. There are several types of internal devices. The Modular Internal Distraction System developed by one of the authors (S.R.C.) and Stryker-Leibinger, Inc. has had widespread use for midface distraction, but requires a substantial surgical procedure for device removal. This is justified in selected children with syndromic craniosynostosis, who frequently need secondary orbitocranial reconstruction at the conclusion of distraction with any type of device. It would be preferable to develop a device that would retain the positive characteristics of the Modular Internal Distraction system, while allowing easy removability. Moreover, the entire distraction procedure would benefit from a technique that would assist in bone regeneration within the distraction gap. Such a biodegradable, stabilizing device may enable early explanation, accelerating the recovery period, while providing fixation of the distraction gap and protected bone regeneration. Accordingly, we have developed a new, biodegradable distraction device with Macropore, Inc. that may be used with the Modular Internal Distraction system to permit easy removability of the device without the need for a large operation for exposure. Second, we have developed a biodegradable stabilizer that permits earlier removal of the distraction device while providing simultaneous fixation and protected bone regeneration. Last, we have demonstrated the feasibility of midcourse correction of the distraction procedure, should this be necessary for whatever reason.

Absorbable Implants↗