PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Microfluidics”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12Linked to original sources

A novel microfluidic device for male subfertility screening.

PURPOSE: To our knowledge no simple, disposable and accurate test of semen quality currently exists. A novel technique to assess the motile sperm concentration of the human ejaculate has been designed and its results are presented. MATERIALS AND METHODS: In a micromachined device fluorescently labeled motile sperm traverse a hydrostatic microfluid line to a target detection cuvette. A microfluorometer assesses the fluorescence signal generated by sperm accumulating there throughout a 50-minute study period. A total of 21 semen specimens from men presenting to our university based reproductive endocrinology and infertility center were tested a total of 67 times. Semen parameters determined by computer assisted semen analysis were compared to the signal reported by the microfluidic device. RESULTS: The fluorescence signal increased throughout the data collection period for all samples. Pearson r values relating the device signal to total and progressive motile concentration were 0.79 and 0.80, respectively (each p <0.001). A signal threshold based on the aggregate data were established, correlating with the WHO standard of the normal total motile sperm concentration. As a screening test, the device was 94% sensitive and 97% specific for identifying samples with less than the WHO standard for the total motile concentration, and 96% sensitive and 90% specific when considering the progressive motile concentration. CONCLUSIONS: A novel microfluidic device is presented that enables accurate assessment of the motile sperm concentration in human ejaculate compared to computer assisted semen analysis. Its size and design demonstrate the feasibility of applying laboratory on chip technology to male infertility screening.

Diagnostic Techniques, Urological↗

The promise of macromolecular crystallization in microfluidic chips.

Microfluidics, or lab-on-a-chip technology, is proving to be a powerful, rapid, and efficient approach to a wide variety of bioanalytical and microscale biopreparative needs. The low materials consumption, combined with the potential for packing a large number of experiments in a few cubic centimeters, makes it an attractive technique for both initial screening and subsequent optimization of macromolecular crystallization conditions. Screening operations, which require a macromolecule solution with a standard set of premixed solutions, are relatively straightforward and have been successfully demonstrated in a microfluidics platform. Optimization methods, in which crystallization solutions are independently formulated from a range of stock solutions, are considerably more complex and have yet to be demonstrated. To be competitive with either approach, a microfluidics system must offer ease of operation, be able to maintain a sealed environment over several weeks to months, and give ready access for the observation and harvesting of crystals as they are grown.

Biopolymers↗

Planar microcoil-based microfluidic NMR probes.

Microfabricated small-volume NMR probes consisting of electroplated planar microcoils integrated on a glass substrate with etched microfluidic channels are fabricated and tested. 1H NMR spectra are acquired at 300 MHz with three different probes having observed sample volumes of respectively 30, 120, and 470 nL. The achieved sensitivity enables acquisition of an 1H spectrum of 160 microg sucrose in D2O, corresponding to a proof-of-concept for on-chip NMR spectroscopy. Increase of mass-sensitivity with coil diameter reduction is demonstrated experimentally for planar microcoils. Models that enable quantitative prediction of the signal-to-noise ratio and of the influence of microfluidic channel geometry on spectral resolution are presented and successfully compared to the experimental data. The main factor presently limiting sensitivity for high-resolution applications is identified as being probe-induced static magnetic field distortions. Finally, based on the presented model and measured data, future performance of planar microcoil-based microfluidic NMR probes is extrapolated and discussed.

Electronics↗

A microfluidic electrocapture device in sample preparation for protein analysis by MALDI mass spectrometry.

The design and operation of a microfluidic device for sample preparation in MALDI mass spectrometry of peptides and proteins is described. It is particularly useful for proteomics applications and for mass determination of proteins in salt- and detergent-containing solutions. The system consists of a flow channel with two conductive areas or electrical junctions where proteins and peptides are retained by means of an electric field. The microfluidic device is made of PEEK tubing, and the junctions are covered with a conductive polymeric membrane. A syringe pump connected to the device produces a flow stream, and injection of sample is carried out manually via hydrodynamic pressure. Proteolytic peptides and intact proteins in salt- and detergent-containing acidic media were captured at the cathode junction followed by exchange of the original solution to a solvent suitable for subsequent mass spectrometry. Using this principle, a significant desalting effect was obtained for tryptic peptides in mass-mapping experiments. Protein sequence coverages were high (up to 40%) at subpicomole levels with results better than those obtained using reversed-phase solid-phase extraction. In contrast to the latter technique, the microfluidic device has the capacity to efficiently remove detergents such as CHAPS before peptide mapping and protein analysis.

Animals↗

Integrated hydrogenated amorphous Si photodiode detector for microfluidic bioanalytical devices.

Hydrogenated amorphous silicon (a-Si:H) PIN photodiodes have been developed and characterized as fluorescence detectors for microfluidic analysis devices. A discrete a-Si:H photodiode is first fabricated on a glass substrate and used to detect fluorescent dye standards using conventional confocal microscopy. In this format, the limit of detection for fluorescein flowing in a 50-microm deep channel is 680 pM (S/N = 3). A hybrid integrated detection system consisting of a half-ball lens, a ZnS/YF3 multilayer optical interference filter with a pinhole, and an annular a-Si:H photodiode is also developed that allows the laser excitation to pass up through the central aperture in the detector. Using this integrated detection device, the limit of detection for fluorescein is 17 nM, and DNA fragment sizing and chiral analysis of glutamic acid are successfully performed. The a-Si:H detector exhibits high sensitivity at the emission wavelengths of commonly used fluorescent dyes and is readily microfabricated and integrated at low cost making it ideal for portable microfluidic bioanalyzers and emerging large scale integrated microfluidic technologies.

Bacteriophage phi X 174↗

DNA mutation detection in a polymer microfluidic network using temperature gradient gel electrophoresis.

A miniaturized system for DNA mutation analysis, utilizing temperature gradient gel electrophoresis (TGGE) in a polycarbonate (PC) microfluidic device, is reported. TGGE reveals the presence of sequence heterogeneity in a given heteroduplex sample by introducing a thermal denaturing gradient that results in differences between the average electrophoretic mobilities of DNA sequence variants. Bulk heater assemblies are designed and employed to externally generate temperature gradients in spatial and temporal formats along the separation channels. TGGE analyses of model mutant DNA fragments, each containing a single base substitution, are achieved using both single- and 10-channel parallel measurements in a microfluidic platform. Additionally, a comprehensive polymer microfluidic device containing an integrated microheater and sensor array is developed and demonstrated for performing spatial TGGE for DNA mutation analysis. The device consists of two PC modular substrates mechanically bonded together. One substrate is embossed with microchannels, and the other contains a tapered microheater, lithographically patterned along with an array of temperature sensors. Compared with the external heating approaches, the integrated platform provides significant reduction in power requirement and thermal response time while establishing more accurate and highly effective control of the temperature gradient for achieving improved separation resolution.

DNA Mutational Analysis↗

Patterning enzymes inside microfluidic channels via photoattachment chemistry.

We have developed a general method for photopatterning well-defined patches of enzymes inside a microfluidic device at any location. First, a passivating protein layer was adsorbed to the walls and floor of a poly(dimethylsiloxane)/glass microchannel. The channel was then filled with an aqueous biotin-linked dye solution. Using an Ar+/Kr+ laser, the fluorophore moieties were bleached to create highly reactive species. These activated molecules subsequently attached themselves to the adsorbed proteins on the microchannel walls and floor via a singlet oxygen-dependent mechanism. Enzymes linked to streptavidin or avidin could then be immobilized via (strept)avidin/biotin binding. Using this process, we were able to pattern multiple patches of streptavidin-linked alkaline phosphatase inside a straight microfluidic channel without the use of valves under exclusively aqueous conditions. The density of alkaline phosphatase in the patches was calculated to be approximately 5% of the maximum possible density by comparison with known standards. Turnover was observed via fluorogenic substrate conversion and fluorescence microscopy. A more complex two-step enzyme reaction was also designed. In this case, avidin-linked glucose oxidase and streptavidin-linked horseradish peroxidase were sequentially patterned in separate patches inside straight microfluidic channels. Product formed at the glucose oxidase patch became the substrate for horseradish peroxidase, patterned downstream, where fluorogenic substrate turnover was recorded.

Animals↗

A soft lithographic approach to fabricate patterned microfluidic channels.

The control of surface properties and spatial presentation of functional molecules within a microfluidic channel is important for the development of diagnostic assays and microreactors and for performing fundamental studies of cell biology and fluid mechanics. Here, we present a simple technique, applicable to many soft lithographic methods, to fabricate robust microchannels with precise control over the spatial properties of the substrate. In this approach, the patterned regions were protected from oxygen plasma by controlling the dimensions of the poly(dimethylsiloxane) (PDMS) stamp and by leaving the stamp in place during the plasma treatment process. The PDMS stamp was then removed, and the microfluidic mold was irreversibly bonded to the substrate. The approach was used to pattern a nonbiofouling poly(ethylene glycol)-based copolymer or the polysaccharide hyaluronic acid within microfluidic channels. These nonbiofouling patterns were then used to fabricate arrays of fibronectin and bovine serum albumin as well as mammalian cells. In addition, further control over the deposition of multiple proteins onto multiple or individual patterns was achieved using laminar flow. Also, cells that were patterned within channels remained viable and capable of performing intracellular reactions and could be potentially lysed for analysis.

Animals↗

Ligase detection reaction/hybridization assays using three-dimensional microfluidic networks for the detection of low-abundant DNA point mutations.

We have fabricated a flow-through biochip assembly that consisted of two different microchips: (1) a polycarbonate (PC) chip for performing an allele-specific ligation detection reaction (LDR) and (2) a poly(methyl methacrylate) (PMMA) chip for the detection of the LDR products using an universal array platform. The operation of the device was demonstrated by detecting low-abundant DNA mutations in gene fragments (K-ras) that carry point mutations with high diagnostic value for colorectal cancers. The PC microchip was used for the LDR in a continuous-flow format, in which two primers (discriminating primer that carried the complement base to the mutation being interrogated and a common primer) that flanked the point mutation and were ligated only when the particular mutation was present in the genomic DNA. The miniaturized reactor architecture allowed enhanced reaction speed due to its high surface-to-volume ratio and efficient thermal management capabilities. A PMMA chip was employed as the microarray device, where zip code sequences (24-mers), which were complementary to sequences present on the target, were microprinted into fluidic channels embossed into the PMMA substrate. Microfluidic addressing of the array reduced the hybridization time significantly through enhanced mass transport to the surface-tethered zip code probes. The two microchips were assembled as a single integrated unit with a novel interconnect concept to produce the flow-through microfluidic biochip. A microgasket, fabricated from an elastomer poly(dimethylsiloxane) with a total volume of the interconnecting assembly of <200 nL, was used as the interconnect between the two chips to produce the three-dimensional microfluidic network. We successfully demonstrated the ability to detect one mutant DNA in 100 normal sequences with the biochip assembly. The LDR/hybridization assay using the assembly performed the entire assay at a relatively fast processing speed: 6.5 min for on-chip LDR, 10 min for washing, and 2.6 min for fluorescence scanning (total processing time 19.1 min) and could screen multiple mutations simultaneously.

Base Sequence↗

Integrated lectin affinity microfluidic chip for glycoform separation.

Lectin affinity chromatography was miniaturized into a microfluidic format, which results in improvement of performance, as compared to the conventional method. A lectin affinity monolith column was prepared in the microchannel of a microfluidic chip. The porous monolith was fabricated by UV-initiated polymerization of ethylene dimethacrylate (EDMA) and glycidyl methacrylate (GMA) in the presence of porogeneities, followed by immobilization of pisum sativum agglutinin (PSA) on the monolith matrix. Using electroosmosis as the driven force, lectin affinity chromatographies of three kinds of glycoprotein, turkey ovalbumin (TO), chicken ovalbumin (CO), and ovomucoid (OM), were carried out on the microfluidic system. All the glycoproteins were successfully separated into several fractions with different affinities toward the immobilized PSA. The integrated system reduces the time required for the lectin affinity chromatography reaction to approximately 3%, thus, the overall analysis time from 4 h to 400 s. Only 300 pg of glycoprotein is required for the whole separation process. Moreover, troublesome operations for lectin affinity chromatography are simplified.

Adsorption↗

Microfluidic T-form mixer utilizing switching electroosmotic flow.

This paper presents a microfluidic T-form mixer utilizing alternatively switching electroosmotic flow. The microfluidic device is fabricated on low-cost glass slides using a simple and reliable fabrication process. A switching DC field is used to generate an electroosmotic force which simultaneously drives and mixes the fluid samples. The proposed design eliminates the requirements for moving parts within the microfluidic device and delicate external control systems. Two operation modes, namely, a conventional switching mode and a novel pinched switching mode, are presented. Computer simulation is employed to predict the mixing performance attainable in both operation modes. The simulation results are then compared to those obtained experimentally. It is shown that a mixing performance as high as 97% can be achieved within a mixing distance of 1 mm downstream from the T-junction when a 60 V/cm driving voltage and a 2-Hz switching frequency are applied in the pinched switching operation mode. This study demonstrates how the driving voltage and switching frequency can be optimized to yield an enhanced mixing performance. The novel methods presented in this study provide a simple solution to mixing problems in the micro-total-analysis-systems field.

Electrochemistry↗

A microfluidic system for large DNA molecule arrays.

Single molecule approaches offer the promise of large, exquisitely miniature ensembles for the generation of equally large data sets. Although microfluidic devices have previously been designed to manipulate single DNA molecules, many of the functionalities they embody are not applicable to very large DNA molecules, normally extracted from cells. Importantly, such microfluidic devices must work within an integrated system to enable high-throughput biological or biochemical analysis-a key measure of any device aimed at the chemical/biological interface and required if large data sets are to be created for subsequent analysis. The challenge here was to design an integrated microfluidic device to control the deposition or elongation of large DNA molecules (up to millimeters in length), which would serve as a general platform for biological/biochemical analysis to function within an integrated system that included massively parallel data collection and analysis. The approach we took was to use replica molding to construct silastic devices to consistently deposit oriented, elongated DNA molecules onto charged surfaces, creating massive single molecule arrays, which we analyzed for both physical and biochemical insights within an integrated environment that created large data sets. The overall efficacy of this approach was demonstrated by the restriction enzyme mapping and identification of single human genomic DNA molecules.

DNA↗

Passive microfluidic control of two merging streams by capillarity and relative flow resistance.

In the progress of microfluidic devices, a simple and precise control of multiple streams has been essential for complex microfluidic networks. Consequently, microfluidic devices, which have a simple structure, typically use external energy sources to control the multiple streams. Here, we propose a pure passive scheme that uses capillarity without using external force or external regulation to control the merging of two streams and even to regulate their volumetric flow rate (VFR). We accomplish this process by controlling the geometry of two inlets and a junction, and by regulating the hydrophilicity of a substrate. Additionally, we use the relative flow resistance to control the VFR ratio of the merged two streams. Our results will significantly simplify the control of multiple streams without sacrificing precision.

Capillary Action↗

Development of a microfluidic platform with an optical imaging microarray capable of attomolar target DNA detection.

In this paper, DNA hybridization in a microfluidic manifold is performed using fluorescence detection on a fiber-optic microarray. The microfluidic device integrates optics, sample transport, and fluidic interconnects on a single platform. A high-density optical imaging fiber array containing oligonucleotide-labeled microspheres was developed. DNA hybridization was observed at concentrations as low as 10 aM with response times of less than 15 min at a flow rate of 1 microL/min using 50 microL of target DNA samples. The fast response times coupled with the low sample volumes and the use of a high-density, fiber-optic microarray format make this method highly advantageous. This paper describes the initial development, optimization, and integration of the microfluidic platform with imaging fiber arrays.

Bacillus thuringiensis↗

Microfluidic biosensor based on an array of hydrogel-entrapped enzymes.

Here we show that a microfluidic sensor based on an array of hydrogel-entrapped enzymes can be used to simultaneously detect different concentrations of the same analyte (glucose) or multiple analytes (glucose and galactose) in real time. The concentration of paraoxon, an acetylcholine esterase inhibitor, can be quantified using the same approach. The hydrogel micropatch arrays and the microfluidic systems are easy to fabricate, and the hydrogels provide a convenient, biocompatible matrix for the enzymes. Isolation of the micropatches within different microfluidic channels eliminates the possibility of cross talk between enzymes.

Acetylcholinesterase↗

Fabrication of porous polymer monoliths in polymeric microfluidic chips as an electrospray emitter for direct coupling to mass spectrometry.

Coupling of polymeric microfluidic devices to mass spectrometry is reported using porous polymer monoliths (PPM) as nanoelectrospray emitters. Lauryl acrylate-co-ethylene dimethacrylate porous polymer monolith was photopatterned for 5 mm at the end of the channel of microfluidic devices fabricated from three different polymeric substrate materials, including the following: poly(dimethylsiloxane) (PDMS), poly(methyl methacrylate) (PMMA), and cyclic olefin copolymer (COC). Spraying directly from the end of the chip removes any dead volume associated with inserted emitters or transfer lines, and the presence of multiple pathways in the PPM prevents the clogging of the channels, which is a common problem in conventional nanospray emitters. Spraying from a microfluidic channel having a PPM emitter produced a substantial increase in TIC stability and increased sensitivity by as much as 70x compared to spraying from an open end chip with no PPM. The performance of PPM emitter in COC, PMMA, and PDMS chips was compared in terms of stability and reproducibility of the electrospray. COC chips showed the highest reproducibility in terms of chip-to-chip performance, which can be attributed to the ease and reproducibility of the PPM formation due to the favorable optical and chemical properties of COC. We have further tested the performance of the COC chips by constant infusion of poly(propylene glycol) solution at organic content ranging from 10 to 90% methanol and at flow rates ranging from 50 to 1000 nL/min, showing optimum spraying conditions (RSD < 5%) at 50-70% organic content and at flow rates from 100 to 500 nL/min. The PPM sprayer was also used for protein preconcentration and desalting prior to mass spectrometric detection, and results were comparable with a chip spraying from an electrospray tip.

Microfluidics↗

Fluorescence monitoring of ATP-stimulated, endothelium-derived nitric oxide production in channels of a poly(dimethylsiloxane)-based microfluidic device.

Intracellular nitric oxide (NO) production in a microfluidic endothelium is detected using fluorescence microscopy. Bovine pulmonary artery endothelial cells (bPAECs) were loaded with the fluorescence probe diaminodifluorofluorescein diacetate (DAF-FM DA), and the subsequent fluorescent DAF-FM DA/NO adduct was measured. Solutions of bradykinin, a well-known stimulus of endothelium-derived NO, activated nitric oxide synthase (NOS) in the immobilized bPAECs. This activation was inhibited using l-nitro arginine methyl ester (L-NAME), a competitive inhibitor of NOS. Importantly, the NO production was also stimulated with adenosine triphosphate (ATP) using concentrations as low as 1 microM. Previous reports on stimulating NO production using an immobilized endothelium in microfluidic channels were limited by the requirement of ATP concentrations of at least 100 microM, a value that is not physiologically relevant. The ability to monitor NO production with ATP concentrations that are similar to in vivo levels of ATP in the microcirculation represents a major advance in the use of microfluidic technology as an in vitro model of the microcirculation.

Adenosine Triphosphate↗

Electrokinetic protein preconcentration using a simple glass/poly(dimethylsiloxane) microfluidic chip.

We discovered that a protein concentration device can be constructed using a simple one-layer fabrication process. Microfluidic half-channels are molded using standard procedures in PDMS; the PDMS layer is reversibly bonded to a glass base such as a microscope slide. The microfluidic channels are chevron-shaped, in mirror image orientation, with their apexes designed to pass within approximately 20 microm of each other, forming a thin-walled section between the channels. When an electric field is applied across this thin-walled section, negatively charged proteins are observed to concentrate on the anode side of it. About 10(3)-10(6)-fold protein concentration was achieved in 30 min. Subsequent separation of two different concentrated proteins is easily achieved by switching the direction of the electric field in the direction parallel to the thin-walled section. We hypothesize that a nanoscale channel forms between the PDMS and the glass due to the weak, reversible bonding method. This hypothesis is supported by the observation that, when the PDMS and glass are irreversibly bonded, this phenomenon is not observed until a very high E-field was applied and dielectric breakdown of the PDMS is observed. We therefore suspect that the ion exclusion-enrichment effect caused by electrical double layer overlapping induces cationic selectivity of this nanochannel. This simple on-chip protein preconcentration and separation device could be a useful component in practically any PDMS-on-glass microfluidic device used for protein assays.

Animals↗