[CULTIVATION OF TAHYN'A VIRUS IN RABBIT LUNG TISSUE CELL LINES AND ITS USE IN THE VIRUS NEUTRALIZATION TEST. PRELIMINARY REPORT].
Explore the source record for details and available documents.
SEARCH · PubMed Health
Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
An ELISA-based micro-neutralization (Nt) test in MRC-5 cells for titration of neutralizing antibodies against human cytomegalovirus (CMV) in human plasma and preparations of immune globulins was developed to eliminate microscopic reading of cytopathic effect (CPE), a process that is subjective and time consuming. Un-neutralized CMV from the Nt reaction and grown in MRC-5 cells as per the standard micro-Nt test was coated in the same plates by various methods and CMV antigen was quantified by polyclonal or monoclonal CMV antibodies. Optimal coating of plates with CMV antigen (100 TCID50 of virus grown on MRC-5 cells for 7 days) was obtained by freezing/thawing of virus infected MRC-5 cells in phosphate buffered saline, ph 7.2. The CMV antigen treated sequentially with CMV monoclonal antibody to late nuclear protein antigen, goat anti-mouse IgG3 alkaline phosphatase conjugate and phosphatase substrate gave an absorbance of 1 at 410 nm wavelength whereas uninfected MRC-5 cells treated under similar conditions did not show any absorbance. The optimal Nt reaction occurred at 37 degrees C for 1-2 h and was unaffected by complement. At 4 degrees C, CMV was inactivated in 1-2 h. The antibody titres were affected by the virus dose used in the Nt test over a range of 20 to 798 TCID50. When the titre was determined against a reference serum, the effect of virus dose on the Nt titre was reduced. Complete neutralization virus read microscopically correlated with ELISA absorbance of < 0.1. CPE produced by approximately 1 TCID50 of CMV showed an absorbance of 0.1 or more. The correlation coefficient (r) between Nt titres and CMV IgG antibodies determined by ELISA was 0.69 (P < 0.001) for 257 human plasma samples and 0.85 (P < 0.001) for 50 immune globulin preparations.
The active coexistence of two pathogenic arenaviruses, Junin (JUNV) and lymphocytic choriomeningitis (LCMV), in the same region of Argentina, has been known since the early 70's, and records of clinical and subclinical human infections by one and/or the other agent have been continuously produced for the last 25 years. Anti-LCMV antibody is currently searched only by indirect immunofluorescence, a test that shows cross reactions among a number of arenaviruses yielding, in the cases of LCMV and JUNV consecutive infections, a concomitant seroconversion for both viruses, as an inconclusive diagnostic result. In contrast, neutralization (NT) tests reveal arenavirus antibodies directed to unique epitopes on these virus envelopes, thus allowing to disclose the sequence in the cases of consecutive infections. In this paper, the characteristics of neutralization (NT) test for LCMV in cell cultures are described, as well as its performance in the field diagnosis of LCMV human infections. The native LCMV strain Cba An 13065 was inoculated on L-929 cell (ATCC CCL 1), and procedures were followed to perform a constant virus-variable serum NT test. Final points of sera titrations were expressed as the maximal serum dilution that yielded 75% of pfu inhibition. This NT test was assayed on paired serum samples of 36 patients with confirmed Argentine hemorrhagic fever (AHF) (a disease caused by JUNV), who had had a known previous contact with LCMV through IFI. The use of this one test led to confusing diagnosis of the disease due to concomitant seroconversion for JUNV and LCMV. By using NT test, it was shown that: some of them were possibly not infected by LCMV, and that 30/36 cases (83.3%) had a pre-existing level of LCMV antibody, with titers in the range of 5 to 640, remaining unchanged 60 days after the clinical AHF. This shows that NT antibodies to LCMV are not influenced by the outcome of the immune response to JUNV, thus confirming the efficiency of NT test as identificator among arenaviruses. To assess the performance of this NT test in individuals having only IFI antibodies to LCMV, 126 serum samples obtained through serological surveillance in a rural area of Argentina, were used. It was found that NT had improved coincidence with IFI as IFI titers increased. Interpretations were based on the pan-arenavirus antibody response obtained by using IFI as the only test. Results presented herein prove that the described NT test is a valuable tool for the detection of LCMV infections, particularly when a previous infection with LCMV has to be demonstrated during the acute phase of Argentine hemorrhagic fever.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Four commercially available enzyme immunoassay (EIA) kits were evaluated in comparison with the plaque reduction neutralization (PRN) test for detection of measles virus antibody. The EIA kits, Enzygnost (Behring), Diamedix, Vidas (bioMerieux Vitek), and Measlestat (Biowhittaker), were assessed with two PRN cutoff titers: a PRN titer of 8, the lowest detectable antibody level by the PRN test under the test conditions, and a titer of 120, which has been shown to be the minimum protective antibody titer. At a PRN cutoff titer of 8, the sensitivity was 88.2, 91.1, 74.6, and 69.8% for Behring, Diamedix, Vidas, and Biowhittaker EIA tests, respectively, with negative predictive values ranging from 22.7 to 45.5%. The specificity was 93.8% for Diamedix and 100% for the rest. At a PRN cutoff titer of 120, the sensitivity and specificity, respectively, were 100 and 90.7% (Behring), 98.2 and 58.8% (Diamedix), 90.6 and 94.5% (Vidas), and 85.7 and 96.4% (Biowhittaker). At this PRN cutoff titer, the negative predictive values of all EIA tests improved considerably, ranging from 70.7 to 100%. The EIA results showed an excellent association with PRN results when the PRN titers of the test samples were either < 8 or > 1,052. Discrepancies occurred especially when testing samples having PRN titers in the range of 8 to 120, indicating lack of sensitivity of the EIA tests in detecting measles virus antibody at low levels. Maternally derived measles virus antibody at this level has been shown to interfere with measles vaccine response in children and hence has implications from the standpoint of measles immunization. The ready availability, ease of operation, and rapid turnaround time are strong plus points of the EIA kits, and they could be useful in a clinical laboratory setting for routine application, but they may have limited use in vaccine-related studies and seroepidemiological surveys.
An indirect enzyme-linked immunosorbent assay (ELISA) for the detection of serum antibody to bovine respiratory syncytial virus (BRSV) was developed and compared with complement-fixation (CF) and viral neutralization (VN) tests. Tissue culture-grown viral antigens were used in the tests. Serum samples from various sources were compared, including serum samples from 10 calves which were infected experimentally with BRSV by aerosol exposure. The ELISA compared favorably with the VN test for detecting serologic responses and for detecting passively acquired antibody in young calves. Approximately 98% (109/111) of field serum samples which were positive by the VN test were also positive by ELISA. The ELISA and the CF test both failed to detect early appearing (1 to 4 weeks after exposure) antibody in 2 experimental calves with subclinical infection with BRSV. The CF test appeared to be less specific in that it gave positive reactions with some sera which were negative by both the ELISA and the VN test. The CF test did not detect antibody in 50% of serum samples obtained at the farm from young feeder calves which were positive by both ELISA and the VN test. The ELISA appears to be a sensitive and specific serologic procedure for detecting serum antibody to BRSV and has the advantage of giving test results within several hours, whereas the VN test requires 5 to 6 days for completion.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Titers of hemorrhagic fever with renal syndrome virus were estimated by counting foci stained with peroxidase-antiperoxidase or by using immunofluorescence methods. Foci stained with PAP were clearer and easier to count. The peroxidase-antiperoxidase method showed a linear relationship between virus concentration and the number of foci. A focus-reduction neutralizing antibody test was performed with immune rat sera and sera from patients. Again, the peroxidase-antiperoxidase method proved to be more convenient and reliable than the immunofluorescence method. Antigenic differences between Hantaan virus, 76-118 and hemorrhagic fever with renal syndrome virus B-1 were clearly demonstrated by the neutralizing antibody test.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
We established a 50% plaque reduction analyzing method of neutralizing antibody for human serum to Japanese encephalitis virus (JEV) in Vero cells, called the '3 points least-squares regression method' (3LSRM). Our method shows a high correlation with the chick embryo cell method (the current standard method for human serum), using the chart method established by the National Institute of Infectious Diseases of Japan, which is an equation made with retrospective data obtained with the 50% plaque reduction method as a standard measurement method for neutralizing antibody titers to JEV. Our new method is much simpler and more reliable than the current method in that it uses an established cell line, Vero cells, and its results are computed by the 3LSRM.