PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Polymethyl Methacrylate”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12Linked to original sources

A stem design change to reduce peak cement strains at the tip of cemented total hip arthroplasty.

A series of 3-dimensional finite element models was created to assess different designs of the tip of the stems of cemented femoral components of total hip arthroplasty that would decrease the peak axial tensile cement strains developed near the tip. Features of stem design that would facilitate positioning the femoral component in a neutral position centered in uniform cement mantle of adequate thickness also were evaluated. These studies showed that a stem that had a narrow tip profile that would accept an externally applied polymethyl methacrylate centralizer shaped similar to a napkin ring and had a gradual transition zone to join the body of the implant achieved these objectives. Such a combination resulted in the reduction of the peak axial strains to less than half the magnitude of the peak strains around a conventional tip (830 vs 1,868 microstrain). The reduction in peak axial strains was to one third the magnitude of the strains developed adjacent to a stem with a hole drilled into the tip to accept the commonly used fin-type polymethyl methacrylate centralizer (830 vs 2,466 microstrain). These goals were achieved because a stem that is designed to accept a napkin ring-style centralizer i) has a lower bending stiffness at the tip of the implant, ii) allows room for a thicker cement mantle, and iii) avoids creating a stress riser adjacent to the edge of the drill hole. The peak cement strains adjacent to a stem of this design are well below the endurance limit of cement as long as the transition zone where the narrow tip meets the body of the implant is gradual.

Biomechanical Phenomena↗

Corneal optical aberrations and retinal image quality in patients in whom monofocal intraocular lenses were implanted.

OBJECTIVES: To compare retinal image quality and optical corneal aberrations in patients in whom monofocal polymethyl methacrylate intraocular lenses (IOLs) were implanted with those in healthy subjects of a similar older age (60-70 years old) and to use the results to suggest improved optical designs of IOLs to maximize retinal image quality. METHODS: A double-pass apparatus was used to measure retinal image quality for 3-, 4-, and 6-mm pupil diameters. Corneal aberrations for a 4-mm pupil were calculated by a ray-tracing technique from the elevations provided by corneal topography. Two groups of 20 subjects of a similar older age were studied: in one group, polymethyl methacrylate monofocal IOLs were implanted; and in a second group, healthy subjects were used as a reference. RESULTS: The average retinal image quality was similar in older healthy patients and in patients in whom IOLs were implanted, with both groups having a significantly worse image quality than healthy younger subjects (aged 20-30 years). Both groups were more tolerant to defocus than younger subjects. CONCLUSIONS: The average retinal image quality of patients in whom IOLs were implanted was worse than that of healthy younger subjects despite the good optical quality of isolated IOLs. This apparent paradox can be understood by the nature of the aberration coupling in the eyes that undergo implantation. The ideal substitute for the natural lens is not an IOL with the best-isolated optical performance, but rather one designed to compensate for the aberrations of the cornea-a design somehow inspired by the crystalline lens of younger subjects.

Aged↗

The effect of triphenylbismuth on the radiopacity and performance properties of compression- and injection-molded denture resins.

PURPOSE: Methods of incorporating radiopaque triphenylbismuth into an experimental compression-molded and injection-molded heat-polymerized resins were determined. The transverse flexural properties, radiopacity, and color stability of the resins containing triphenylbismuth were then compared with a commercially available, compression-molded denture resin. MATERIALS AND METHODS: Varying levels of triphenylbismuth were added to both the monomer and polymer in heat-polymerized denture resin systems to determine the level of the additive that was necessary to achieve a radiopacity similar to 0.2 mm of copper with minimum resin porosity. Specimens were then prepared by incorporating 0% or 30% wt/wt triphenylbismuth into resins. The commercially available polymethyl methacrylate resin served as a benchmark for physical property comparison, and no additive was included during its polymerization. At 30% wt/wt triphenylbismuth, resin color stability, transverse deflection, and radiopacity were evaluated using methods described in International Standards Organization Standard 4049 and American Dental Association Specification No. 12. The transverse deflection results among the resin groups were compared with a reference resin using the Kruskal-Wallis method (alpha = 0.05). RESULTS: Incorporation of triphenylbismuth into the monomer of the injection material, resulting in 30% wt/wt in the polymerized resin, produced a level of radiopacity similar to 0.2 mm copper. Although the injection-molded resin with 30% wt/wt triphenylbismuth remained translucent, the compression-molded resin was opaque, indicating excessive air-entrapment porosity. The additive caused a faint yellowing in both types of resins, but color stability was not affected. Transverse deflection of the injection-molded resin (4.5 +/- 0.5 mm) and the injection-molded resin with triphenylbismuth (3.8 +/- 1.7 mm) was greater than that of the experimental resin (3.5 +/- 0.2 mm), which was equal to the commercial resin (3.6 +/- 0.2 mm). Triphenylbismuth at 30% wt/wt significantly reduced transverse deflection for the experimental resin (2.6 +/- 0.5 mm). CONCLUSIONS: Triphenylbismuth at a final concentration of 30% wt/wt can be added to polymethyl methacrylate injection-molded resins to provide a high level of detection on chest or abdominal radiographs without adversely affecting resin color stability and transverse deflection.

Benchmarking↗

Femoroplasty-augmentation of mechanical properties in the osteoporotic proximal femur: a biomechanical investigation of PMMA reinforcement in cadaver bones.

OBJECTIVE: To determine the feasibility of polymethyl-methacrylate injection into the osteoporotic proximal femur and its effect on the mechanical properties. DESIGN: In vitro pairwise comparison of non reinforced and reinforced bones in a load to failure loading mode. BACKGROUND: Hip fractures represent an important public healthcare problem. Continued growth in the elderly population will raise the incidence of hip fractures and their associated costs dramatically in the near future. METHODS: Twenty pairs of osteoporotic femurs were mechanically tested either in a single-limb stance configuration or simulating a fall on the greater trochanter. From each pair, one femur was augmented with bone cement, with the contralateral femur serving as a control. The surface temperature at the femoral neck was recorded until twenty minutes after injection. The fracture load and the energy absorption were calculated. The Wilcoxon signed rank test was used to test for differences in fracture load and energy absorption between the reinforced femurs and the native controls. RESULTS: Volumes of 28-41 ml of cement (mean, 36 ml) could be injected. The increase of surface temperature at the femoral neck ranged from delta18.4 to delta29.8 degrees C. For the single limb stance configurations, the peak fracture load was increased by 21%, (P < 0.002) and for the simulated fall on the hip by 82%, (P < 0.002). The corresponding values for energy absorption were +48%; and +188% (P < 0.002) respectively. CONCLUSIONS: The feasibility and mechanical effectiveness of the in vitro procedure could be demonstrated. The heat generation due to polymethyl-methacrylate polymerisation is high. RELEVANCE: Prophylactic reinforcement of the femur could become a treatment option to solve the problems with osteoporotic hip fractures in patients at risk. Reinforcement materials with less exothermic reaction need to be evaluated further and also the feasibility of fracture repair after reinforcement.

Aged↗

Long-term changes in corneal endothelial morphology after discontinuation of low gas-permeable contact lens wear.

PURPOSE: Low gas-permeable contact lens wear of polymethyl methacrylate or hydroxyethyl methacrylate material is known to cause morphologic abnormalities in the corneal endothelial cell layer. These lenses were widely prescribed and successfully worn until their use was actively discouraged in the late 1980s and early 1990s. This study was designed to investigate whether discontinuation of low gas-permeable contact lens wear leads to an improvement of corneal endothelial cell morphology. METHODS: At the time of discontinuation and at least 5 years after discontinuation of low gas-permeable contact lens wear, noncontact specular photographs of the central corneal endothelium were made in 66 patients (14 male and 52 female, mean age 37.7 +/- 8.4, range 24.6-69.0). By computer analysis of endothelial photographs, parameters for polymegethism and pleomorphism were calculated, as well as cell density. RESULTS: Mean follow-up time between photographs was 6.8 years (SD 1.1). Sixty-one patients were refitted with rigid high gas-permeable contact lenses or high-water-content soft lenses, and 5 patients switched to spectacle wear. A small but significant recovery of the corneal endothelial cell morphology was found for the mean coefficient of variation of cell area, from 37.5 to 35.7 (P = 0.022), and for the coefficient of variation of the number of sides, from 13.1 to 12.4 (P = 0.004). The mean percentage of hexagonal cells increased from 54.2 to 56.2 (P = 0.013). Although the corneal endothelial cell morphology improved significantly on cessation of LGP contact lens wear, the values did not return to levels observed in normal, non-contact lens wearing individuals. During follow-up, the mean endothelial cell density decreased significantly (P = 0.001) from 2994 to 2890 (a 3.5% cell loss in 6.8 years), which is similar to the known normal age-related cell loss of 0.6% per year in non-contact lens wearing healthy individuals. CONCLUSION: Endothelial polymegethism and pleomorphism caused by PMMA or HEMA contact lens wear is partly reversible.

Adult↗

Simultaneous histological preparation of bone, soft tissue and implanted biomaterials for light microscopic observations.

Block specimens of formalin fixed bone, soft tissue and endosseous implanted biomaterials can be successfully embedded in polymethyl methacrylate by employing vacuum desiccation during the dehydration steps and refrigeration during the infiltration step. One-hundred-micrometer histological sections can be obtained from the cured polymethyl methacrylate blocks by cutting with a low concentration diamond wafering blade on a Buehler Isomet Circular Low Speed Saw using Buehler Isocut fluid. The sections can be readily stained and details of individual cells studied by light microscopy, thus allowing interpretation of the relationship between biomaterial and surrounding tissues. The advantage of this method is that it allows observations of the entire specimen in situ. The details of the procedure are presented.

Animals↗

Use of antibiotic-impregnated cement during hip and knee arthroplasty in the United States.

A survey of practicing orthopaedists regarding their use of antibiotic(s) in bone-cement (ABC) was carried out. The initial sampling of 2,139 orthopaedists spanned the continental United States. Responses that passed fail-edit criteria were obtained from 1,015 physicians. Clinical practice patterns are highly variable. Adult reconstructive orthopaedic practitioners' belief in antibiotic(s) in bone-cement for the treatment of patients with previous sepsis is favorable. This opinion can be supported at the guideline level. Guidelines suggesting that liquid antibiotics should not be used as additions to polymethyl methacrylate are also supportable. The need for careful scientific inquiry and cost-effectiveness evaluation of the benefits and risks relating to the use of antibiotic additions to polymethyl methacrylate cement in joint arthroplasty exists. On the basis of such inquiry, educational dissemination to reduce practice variation would be indicated.

Anti-Bacterial Agents↗

Periprosthetic femoral osteolysis around an uncemented nonmodular Moore prosthesis.

Periprosthetic osteolysis is a major problem in total joint arthroplasty surgery today. The particulate debris from ultrahigh-molecular-weight polyethylene, polymethyl methacrylate, and corrosion products from modular connections have been implicated in this process. A case of femoral osteolysis at the tip of a nonmodular Moore prosthesis, in the absence of polyethylene, polymethyl methacrylate, and modular connections, is reported. In the area of osteolysis, histochemical and in situ hybridization techniques established the expression of messenger ribonucleic acid encoding for certain cytokines implicated in bone resorption, preferentially in the area of osteolysis. This case illustrates that the etiology of periprosthetic osteolysis is multifactorial and can occur in the absence of polyethylene, methacrylate, or modular components. All joint implants should be monitored for the development of this complication.

Aged↗

Custom impression trays: Part I--Mechanical properties.

Dimensional stability of custom impression trays is an important factor in determining the degree of accuracy achieved in forming a master cast. Such trays must remain stable over time and must not exhibit permanent deformation when a completed impression is removed from the oral cavity. Measurement of the mechanical properties allows comparison between various tray materials and is useful in interpreting data on stresses incurred during removal of the completed impression. In Part I of this three-part series, the various mechanical properties of five tray resins: one autopolymerizing polymethyl methacrylate, one light-polymerizing, and three brands of thermoplastic resins were recorded and compared. The thermoplastic resins studied in this investigation exhibited lower measured values for the strength and elastic modulus properties than the light-polymerizing resin and the autopolymerizing polymethyl methacrylate resin studied.

Dental Impression Technique↗

[Treatment of spinal metastases by posterolateral approach].

OBJECTIVE: To evaluate the value of spondylectomy, circumferential decompression, and spinal reconstruction for the treatment of spinal metastases using posterolater approach. METHODS: Thirteen patients with spinal metastases were treated by spondylectomy, circumferential spinal cord decompression, and spinal reconstruction with pedicle fixation and polymethyl methacrylate. The outcome was assessed by pain relief and the improvement in neurologic symptoms. RESULTS: Pain relief was obvious in all patients. Neurologic symptoms improved to various degrees in 6 patients. CONCLUSION: Spondylectomy, spinal cord circumferential decompression and spinal reconstruction with pedicle fixation and polymethyl methacrylate using posterolateral approach are effective surgical method for spinal metastases.

Adult↗

Renal cell carcinoma and osseous metastases. Case report and literature review.

Renal cell carcinoma is one of the great mimics in medicine. The diagnosis is complicated by clinical presentations involving a multitude of symptoms, often associated with the sites of metastasis. A high percentage of renal cell carcinomas have metastasized at the time of initial presentation, and symptoms associated with this metastasis may actually initiate the diagnosis. Because the site of tumor origin is frequently unknown, a diagnostic strategy for identifying the primary source has been proposed. The prognosis for renal cell carcinoma with metastasis is poor, with fewer than 9% of patients surviving at 5 years. Consequently, treatment is directed primarily at palliation of painful symptoms and stabilization of bony structures. With these goals in mind, treatment modalities run the gamut from radiotherapy, to curettage with polymethyl methacrylate augmentation, to amputation. In the case reported here, renal cell carcinoma was diagnosed in the course of evaluation of a painful lytic lesion of the foot. Treatment alternatives and associated risks and complications were discussed at some length and the patient chose curettage and packing with polymethyl methacrylate in combination with radiotherapy. This approach was successful in palliation of pain and maintenance of walking ability and independence.

Aged↗

Plasma levels of main granulocyte components during hemodialysis: effects of immunosuppression.

Plasma levels of granulocyte lactoferrin, granulocyte myeloperoxidase and granulocyte elastase in complex with alpha 1-proteinase inhibitor were investigated during hemodialysis in oliguric patients following cadaveric renal transplantation (CRT). The results were compared with those of patients undergoing regular hemodialysis treatment (RDT) using different membrane materials. In RDT patients, plasma lactoferrin levels increased from 61.9 +/- 10.2 to 417.9 +/- 96.7 using dialyzers made of cuprophane. Dialyzers made of polymethyl methacrylate induced an increase of lactoferrin from 166.6 +/- 28.5 to 712.5 +/- 165.9 and dialyzers made of polyacrylonitrile an increase from 122.6 +/- 23.5 to 647.7 +/- 203.6 ng/ml. In CRT patients, in contrast, plasma lactoferrin levels increased from 49.1 +/- 10.9 to 199.6 +/- 45.9 (cuprophane), from 30.1 +/- 6.9 to 252.5 +/- 46.9 (polymethyl methacrylate), and from 43.3 +/- 9.1 to 174.2 +/- 39.3 ng/ml (polyacrylonitrile). On the other hand, the plasma levels of myeloperoxidase and elastase in complex with alpha 1-proteinase inhibitor increased comparably in both groups of patients. Our data suggest that immunosuppression might prevent degranulation of specific granules independently of the used dialyzer membrane material, whereas no effect was observed on two main components of azurophilic granules.

Adult↗

[An experimental study of the pathogenetic mechanisms of uveitis following cataract extraction and implantation of an artificial lens].

The paper analyses results after experimental investigations for detection of some mechanisms of postoperative anterior uveitis after lens extraction and implantation of intraocular lens. The methods used were preliminary sensitization of animals by the lens antigen and polymethyl methacrylate, blast transformation reaction, thermometric and biochemical investigations. It is stated that preliminary sensitization stimulates development of a more expressed postoperative inflammatory reaction producing increased sensitivity of animals to antigens. At this, the role of a sensitizing factor can be realized by the lens protein as well as by polymethyl methacrylate. Preliminary immunization of animals in the postoperative period is accompanied by the increase of temperature values and concentration of protein the aqueous humor.

Animals↗

Dynamic mechanical thermal analysis studies of polymer films prepared from aqueous dispersion.

Dynamic Mechanical Thermal Analysis of cast and sprayed films of an aqueous dispersion of polymethyl methacrylate (Eudragit NE30D) and mixtures with an aqueous dispersion of ethylcellulose (Aquacoat ECD-30) has been undertaken. Such analysis allows the identification of glass transition temperatures and the degree of miscibility of the polymers. It was found that the two polymers formed as cast or sprayed films were not miscible but had an optimal composition of 30% of the ethylcellulose dispersion in the polymethyl methacrylate dispersion.

Acrylates↗

The effect of gypsum products and separating materials on the typography of denture base materials.

The typography of polymethyl methacrylate processed against various gypsum products coated with various separating materials was studied under an SEM. Tinfoil and two commercial tin foil substitutes were used as separating material during processing, and the surfaces of the resulting acrylic resin forms were studied for topographical differences. Tinfoil and alpha 2 hemihydrates produced the smoothest surfaces. As a practical solution, a good quality tinfoil substitute and alpha 1 hemihydrate could be used when processing polymethyl methacrylate resin.

Acrylic Resins↗

Variation of cortical hypertrophy depending on the medullary filling material. An experimental study of canine tibial diaphysis.

In order to evaluate the mineralization of bone after polymethyl methacrylate cementation, measurements of the periosteal apposition were made histologically and measurements of the bone-mineral content were made by dual-photon absorptiometry of the tibial diaphysis in 15 adult mongrel dogs in paired studies. Six dogs were investigated 4 weeks after intramedullary reaming of both sides and obturation of the medullary cavity with bone-wax on one side. Nine dogs were reamed on both sides. The medullary cavities were filled with polymethyl methacrylate bone-cement and bone-wax, respectively. The authors found (1) an increased bone-mineral content and an increased periosteal apposition after filling with bone-wax in comparison with the reamed side and (2) a decreased bone-mineral content and a decreased periosteal apposition on the cemented side in comparison with bone-wax. These findings are interpreted as consequential upon repair processes with a high remodeling and mineralization rate after reaming or filling with bone-wax, whereas remodeling in inhibited after filling with acrylic bone-cement.

Absorptiometry, Photon↗

Comparison of serum protein removal in haemodialysis therapy by partly protein-permeable haemodialysers.

Partly protein-permeable haemodialysers were evaluated during haemodialysis therapy for removal of serum low-molecular-mass proteins (10,000-76,000) in patients with chronic renal failure. The six haemodialyser membranes used were cuproammonium rayon (CL-S12W), cellulose acetate (Duo-Flux HP and FF-22), ethylene-vinyl alcohol copolymer (KF-101-15), polyacrylonitrile (H12-2400S) and polymethyl methacrylate (BK2.0H). The analysis was carried out by gel permeation chromatography, sodium dodecyl sulphate polyacrylamide gel electrophoresis (SDS-PAGE) and two-dimensional gel electrophoresis (2-DE). The removal of ten serum proteins per haemodialysis therapy was also carried out by the immunodiffusion method. The protein removal in each haemodialyser is qualitatively comparable to that obtained by SDS-PAGE and 2-DE. beta 2-Microglobulin in the haemodialysate obtained with BK2.0H was removed to a lesser extent than that from the other haemodialysers, which seems to be the reason for its adsorption in the BK2.0H haemodialyser, which contains a polymethyl methacrylate membrane. The amount of serum protein excretion during haemodiafiltration treatment using the partly protein-permeable haemodialysers decreased in the order KF-101-15C greater than BK2.0H greater than CL-S12W greater than Duo-Flux HP greater than FF-22 greater than H12-2400S.

Blood Proteins↗

Reduction of granulocyte activation during hemodialysis with regional citrate anticoagulation: dissociation of complement activation and neutropenia from neutrophil degranulation.

Neutropenia and degranulation of neutrophils during hemodialysis with cellulosic membranes have been linked to complement activation, whereas in the synthetic polymethyl methacrylate (PMMA) membrane, degranulation occurs without notable complement activation. The mechanisms of neutrophil degranulation under these conditions have not yet been elucidated. Ionized calcium is an important prerequisite of granulocyte activation during in vitro blood contact with both types of artificial surfaces. This study compared the effect of normal ionized calcium during heparin anticoagulation with the effect of extracorporeal calcium depletion during regional citrate anticoagulation on activation of blood components. Because ionized calcium is reduced only in the extra-corporeal circuit, citrate anticoagulation in addition helps to differentiate between extracorporeal and systemic activation phenomena. Twelve chronic hemodialysis patients were dialyzed with polymethyl methacrylate (PMMA, 16 treatments) or cuprophane (CUP, 16 treatments) membranes either during regional citrate anticoagulation or while anticoagulated with heparin. During hemodialysis with CUP, anticoagulation with citrate significantly reduced neutropenia, C3a levels, and lactoferrin release. Elastase concentrations, however, were not reduced by citrate, probably because elastase release occurred not locally in the cuprophane dialyzer, but mostly in the systemic circulation of the patient. PMMA did not elevate C3a levels, and neutropenia was only mild. Both parameters were not influenced by citrate anti-coagulation. However, PMMA profoundly induced elastase and lactoferrin release during heparin anti-coagulation. Depletion of ionized calcium markedly reduced PMMA-mediated neutrophil degranulation in the extracorporeal circuit. The results indicate that ionized calcium is a requirement for neutrophil degranulation during hemodialysis. In PMMA membranes, neutrophil degranulation occurs independent of high complement levels, occurs at least partially inside the dialyzer, and requires the presence of ionized calcium in the extracorporeal circuit. In cuprophane membranes, degranulation was uncoupled from neutropenia and did not correlate with the degree of complement activation. Even in cuprophane dialysis, degranulation of secondary granules was markedly dependent on ionized calcium levels in the extracorporeal circuit.

Anticoagulants↗