PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Resolution”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12Linked to original sources

Understanding Dispute Resolution Processes for American and Australian Public Wildlands: Towards a Conceptual Framework for Managers.

/ The last 20 years have seen the successful application of environmental dispute resolution processes, where people voluntarily negotiate toward mutually acceptable solutions, to many environmental disputes. The effects of contextual influences, such as the number of parties and presence of deadlines, on outcomes are known and frequently described. Less well documented and understood are the interaction processes themselves. This paper draws on two case studies to develop a conceptual framework describing these processes. Disputes associated with management planning for the Bob Marshall Wilderness Complex in the United States and Fitzgerald River National Park in Australia provided the cases. The conceptual framework derived had eight sequential stages: (1) joint definition of problems, (2) uncertainty about what to do, (3) agreement on group procedures, (4) realization of interdependence, (5) enthusiasm about collective possibilities, (6) commitment to working together, (7) consolidation of the group, and (8) implementation of a resolution. The framework provides new insights for managers of public wildlands, especially the need for varying but ongoing managerial involvement in dispute resolution processes. High levels of involvement and influence are essential at the beginning in problem definition and group procedure design and at the end in implementing resolutions. Conversely, agency members must be willing to exert less influence, while still being involved and committed to collective purposes, during the middle stages. Also apparent from the conceptual framework is the importance of developing shared understandings and of allowing sufficient time for understanding to develop, if successful resolution is to be achieved. KEY WORDS: Environmental dispute resolution; Conceptual framework; Public wildlands; Shared understandings; Australia

Journal Article↗

Resolution and accuracy in two dimensional echocardiography.

The resolution and accuracy of commercially available two dimensional echocardiographic systems were tested by imaging two types of in vitro test objects. One consisted of a series of fine parallel threads spaced at known intervals and the other was a tissue phantom in which a series of holes of known size had been cut. The echocardiographic systems tested included a mechanical single element sector scanner, a three element rotary sector scanner and a phased array system. Azimuthal resolution, lateral resolution and accuracy of horizontal distance measurements were assessed at depths of 2 and 6 cm. For each system, azimuthal resolution was better than lateral resolution, especially when assessed with use of the parallel threads. When the tissue phantom was imaged, the best resolution (2 mm in azimuthal and lateral directions) was obtained with the highest frequency transducer tested (3.5 MHz). The apparent size of a tissue defect was sensitive to gain settings, especially at a depth of 2 cm with lower frequency transducers; at a depth of 6 cm, echographic measurements of defect size were accurate to within 2.5 mm. Recent applications of two dimensional echocardiography require near the apparent limits of current equipment. It is recommended that the highest frequency transducer and lowest possible gain settings be used in these situations.

Cardiomyopathies↗

Resolution of the enantiomers of various alpha-substituted ornithine and lysine analogs by high-performance liquid chromatography with chiral eluant and by gas chromatography on Chirasil-Val.

A reversed-phase high-performance liquid chromatography method, with L-proline and copper as chiral mobile phase, is described for the enantiomeric resolution of various alpha-substituted ornithine and lysine analogs. Although ornithine gives no separation with the chiral eluant used, excellent resolutions are obtained for various alpha-alkyl-, alpha-halogenomethyl-, alpha-vinyl-, and alpha-ethynyl-substituted ornithines. Similar separations are also observed for the dehydroornithine and lysine analogs. Gas chromatography on a chiral stationary phase, Chirasil-Val, allows the resolution of the ornithine and lysine analogs after derivatization into the monofluoroacyl derivatives of their corresponding lactams. No resolution or only a poor resolution is obtained by GC on Chirasil-Val for the dehydroornithine analogs as their di-N-perfluoroacyl alkyl esters. The chiral eluant HPLC procedure is easily scaled up for the semipreparative resolution of several ornithine analogs, i.e., alpha-fluoromethylornithine, alpha-difluoromethylornithine, alpha-chlorofluoromethylornithine, and alpha-fluoromethyldehydroornithine, which are known as potent ornithine decarboxylase inhibitors in vitro and in vivo.

Chromatography, Gas↗

High resolution autoradiography at the regional topographic level with [14C]2-deoxyglucose and [3H]2-deoxyglucose.

After injection of 2-deoxyglucose (2-DG) labeled with tritium or carbon-14, autoradiograms were produced by thaw-mounting 4 micron frozen sections of rat brains on nuclear emulsion-coated slides. The results show that the distribution of radioactivity among different brain regions was similar and that the resolution at the regional topographical level was virtually identical for both compounds. The resolution obtained with the thaw-mounting of thin frozen sections onto nuclear emulsion was considerably greater than the resolution demonstrated in published results in the literature, when carbon-14 or tritium-labeled 2-deoxyglucose were used with 20 micron frozen sections and X-ray film or tritium-sensitive film. The results indicate that section thickness, detection medium and intimacy of contact between section and photographic emulsion influence resolution. At the regional level, the detection medium apparently influences resolution to a greater extent than the energy differences of the beta particles emitted from 14C or 3H. Although diffusion of radiolabeled 2-deoxyglucose and metabolites during the thaw-mounting process precludes single cell resolution of these autoradiograms, the improvement of visualizing regional topographic detail demonstrates that the described technique is a valuable approach with which to study regional 2-DG uptake.

Animals↗

Emission microscopy and related techniques: resolution in photoelectron microscopy, low energy electron microscopy and mirror electron microscopy.

A unified treatment of the resolution of three closely related techniques is presented: emission electron microscopy (particularly photoelectron microscopy, PEM), low energy electron microscopy (LEEM), and mirror electron microscopy (MEM). The resolution calculation is based on the intensity distribution in the image plane for an object of finite size rather than for a point source. The calculations take into account the spherical and chromatic aberrations of the accelerating field and of the objective lens. Intensity distributions for a range of energies in the electron beam are obtained by adding the single-energy distributions weighted according to the energy distribution function. The diffraction error is taken into account separately. A working resolution is calculated that includes the practical requirement for a finite exposure time, and hence a finite non-zero current in the image. The expressions for the aberration coefficients are the same in PEM and LEEM. The calculated aberrations in MEM are somewhat smaller than for PEM and LEEM. The resolution of PEM is calculated to be about 50 A, assuming conventional UV excitation sources, which provide current densities at the specimen of 5 x 10(-5) A/cm2 and emission energies ranging up to 0.5 eV. A resolution of about 70 A has been demonstrated experimentally. The emission current density at the specimen is higher in LEEM and MEM because an electron gun is used in place of a UV source. For a current density of 5 x 10(-4) A/cm2 and the same electron optical parameters as for PEM, the resolution is calculated to be 27 A for LEEM and 21 A for MEM.

Mathematics↗

Prospects for using an IVEM with a FEG for imaging macromolecules towards atomic resolution.

Specimen preparation and imaging techniques for biological macromolecules have been improved to the point where attention to the electron-optical imaging conditions becomes a significant factor for achieving high resolution. A field emission gun (FEG) can provide an illumination source with a better spatial and temporal coherence suitable for imaging near atomic resolution. Our computational analysis of carbon film images taken between Scherzer focus and 1.1 microns underfocus (20x Scherzer focus) with the Hitachi 200 kV microscope with a cold field emission gun shows detectable contrast beyond 3.5 A resolution. In biological imaging, a large defocus is often used to optimize the low-resolution contrast in order to facilitate the subsequent steps in computer reconstruction. An intermediate-voltage electron microscope (IVEM) would optimize the contrast at high resolution by reducing the temporal coherent effects. In theory, the IVEM would give a greater depth of field so that large macromolecular assemblies such as viruses and cellular structures can be interpreted and reconstructed reliably using the projection approximation. These experimental and theoretical considerations provide a rationale for designing a future IVEM with a FEG suitable for biological macromolecule imaging close to atomic resolution.

Fourier Analysis↗

Capillary zone electrophoresis of peptides: prediction of the electrophoretic mobility and resolution.

The determination of the pKa values of some selected peptides of similar size was performed by microtitration, which makes possible an accurate determination of the peptide charge as a function of the solution pH. Capillary zone electrophoresis separation of these peptides on modified capillaries at acidic pH showed that the electrophoretic mobility correlates with the peptide charge. This observation suggests that when an appropriate charge value is used, the basic electrophoretic equation is respected and, at least at a peptide charge value less than 1, the utilization of alternative semi-empirical predictions is not necessary. As a general rule, a peptide separation at acidic pH values is to be preferred to that at basic pH values. In fact, at basic pH a separation in the absence of both electroosmotic flow and of spurious interactions between the peptides and the inner wall of the capillary is difficult, owing to the instability of capillary modification. Further, from the differences in the peptide charge, a prediction of the best resolution as a function of the pH could be obtained; in fact, the resolution, for peptides of similar size and in the absence of electroosmotic flow, is connected to a simple equation, where the principal term depends on the effective charge of the peptides, which is a function of the pH of the solution and the pKa values of the peptides. The predictions of resolution at acidic pH agreed well with the experimental results; the spatial resolution measured in the separation of met- and leu-enkephalin was virtually coincident with the predicted resolution; in the case of a mixture of four model tetrapeptides of sequence GGNA, GGQA, GGDA and GGEA some anomalous results with respect to the predicted resolutions were observed. Nevertheless, an acceptable prediction can also be made in this case.

Amino Acid Sequence↗

Poly(ethyleneoxide) for high-resolution and high-speed separation of DNA by capillary electrophoresis.

Capillary electrophoresis (CE) with polyacrylamide gels has already been demonstrated to allow single-base resolution of single-stranded DNA. However, linear polyacrylamide is not an ideal matrix because of a high viscosity and difficulties in preparing the polymer with well defined pore sizes. Alternatively, poly(ethyleneoxide) (PEO) with a large range of molecular masses from 300,000 to 8,000,000 is available commercially. In addition, it is easy to prepare homogeneous solutions to provide highly reproducible separation performance with sufficient resolution. Single-base resolution of double-stranded DNA between 123 and 124 base pairs can be achieved by the use of homogeneous matrices prepared from PEO (2.5% M(r) 8,000,000), and even better resolution is achieved by using mixed polymer matrices. With further work, it should be possible to change the fractions and the total amounts of polymers to achieve even higher resolution for different samples with different size ranges of fragments. Another advantage of mixed polymer matrices is that relatively high resolution can be obtained while maintaining a relatively low viscosity compared to linear polyacrylamide with identical contents of formamide and urea, which makes it easier to fill these matrices into small capillaries.

DNA↗

Low resolution spin echo: a simple timesaving technique for MRI liver exams.

MR evaluation of the liver at mid-field strength requires relatively lengthy T2-weighted sequences (T2W) for differentiation of benign cavernous hemangiomas from malignant lesions. A short duration T2W, which maintains standard signal-to-noise ratio and also contrast relationships, can be easily implemented by increasing the pixel size in the phase-encoding direction (thus reducing spatial resolution) and proportionally decreasing the number of phase-encoding steps in the matrix (thus reducing acquisition time). Blinded interpretations of a quick (4 min), low resolution (3.4 mm x 1.7 mm pixel) T2W sequence (matrix 64 x 256, FOV 21.7 cm phase x 43.5 cm frequency) were compared to the 17 min standard resolution (1.7 mm x 1.7 mm) T2W sequence (256 x 256 matrix, FOV 43 x 43 cm) in 25 patients suspected of having liver metastasis. Lesions felt to be cavernous hemangiomas showed a 100% (24/24) agreement for interpreter "A" and 96% (22/23) agreement for interpreter "B" when 4 min low resolution T2W was compared to the standard 17 min sequence. Sensitivity (for all types of lesions) of the low resolution T2W sequence ranged from 100% (31/31) for interpreter "A" to 80% (28/35) for interpreter "B." Missed lesions (interpreter "B") were either partially obscured by excessive fat (wrap around) (N = 4), less than 1 cm in size (N = 2), or degraded by motion artifact (N = 1). Thus in many situations low resolution T2 may provide a substantial timesaving alternative to standard T2W particularly where T2W is used primarily for lesion classification in normal sized patients.

Adult↗

Improved endocardial border resolution during dobutamine stress echocardiography with intravenous sonicated dextrose albumin.

OBJECTIVES: The purpose of this study was to determine whether intravenous sonicated dextrose albumin could improve endocardial border resolution during dobutamine stress echocardiography. BACKGROUND: Sonicated albumin improves endocardial border resolution in patients undergoing exercise stress echocardiography. Because a sonicated mixture of albumin with dextrose results in better transpulmonary passage than sonicated albumin alone, this agent could be utilized to further improve endocardial border resolution during dobutamine stress echocardiography. METHODS: We gave intravenous injections of sonicated dextrose and albumin to 50 patients undergoing dobutamine stress echocardiography. Left ventricular video intensity, contrast agent persistence (in seconds), number of contrast agent-enhanced cardiac cycles and improvement in endocardial border resolution were assessed from the apical four-chamber view at baseline, low dose (10 micrograms/kg body weight per min) and peak dobutamine infusion. RESULTS: There was significantly better left ventricular peak video intensity at peak dobutamine infusion than after the same injection at baseline (p < 0.005, analysis of variance). The number of contrast agent-enhanced cardiac cycles in the left ventricular cavity was also significantly longer at peak infusion. Endocardial border resolution was improved (mainly in lateral segments) in 93% of patients at low dose and 95% of patients at peak infusion. CONCLUSIONS: Intravenous sonicated dextrose albumin improves endocardial border resolution during dobutamine stress echocardiography.

Aged↗

Time course of resolution of persistent air leak in spontaneous pneumothorax.

Persistent air leak (PAL) following tube drainage for spontaneous pneumothorax (SP) is a potentially troublesome complication. The optimum time to intervene surgically is not known. We therefore investigated the rate of resolution of PAL (defined as continued air leak at 2 days after tube insertion) in patients treated medically. We retrospectively reviewed the records of 214 patients presenting with SP over 5 yr. One hundred and forty-two (67%) had tube drainage and in 73 (51%) of these a PAL developed. Overall median time to resolution in the 43 patients with PAL treated medically was 8 days from tube insertion, but PAL resolution was longer in those with underlying lung disease (n = 19) than those without such disease (11 days vs. 7 days, P = 0.05). In patients with normal lungs 20/24 had resolved by 9 days but subsequently the rate of resolution was much slower. In those with abnormal lungs only 8/19 had resolved by 9 days (P < 0.05 compared with those with normal lungs) but the rate of resolution in such patients appeared to change little subsequently. The size of the initial SP did not influence the rate of resolution of PAL. For patients with PAL and normal lungs, surgery at 7-9 days from tube insertion would provide a reasonable opportunity for the PAL to resolve with medical treatment. For those with underlying lung disease there is no clear optimal time and decisions need to be taken on an individual basis.

Adolescent↗

Two-dimensional crystallization of Escherichia coli-expressed bacteriorhodopsin and its D96N variant: high resolution structural studies in projection.

Highly ordered two-dimensional (2-D) crystals of Escherichia coli-expressed bacteriorhodopsin analog (e-bR) and its D96N variant (e-D96N) reconstituted in Halobacterium halobium lipids have been obtained by starting with the opsin protein purified in the denaturing detergent sodium dodecyl sulfate. These crystals embedded in glucose show electron diffraction in projection to better than 3.0 A at room temperature. This is the first instance that expressed bR or a variant has been crystallized in 2-D arrays showing such high order. The crystal lattice is homologous to that in wild-type bR (w-bR) in purple membranes (PM) and permit high resolution analyses of the structure of the functionally impaired D96N variant. The e-bR crystal is isomorphous to that in PM with an overall averaged fractional change of 12.7% (26-3.6-A resolution) in the projection structure factors. The projection difference Fourier map e-bR-PM at 3.6-A resolution indicates small conformational changes equivalent to movement of approximately < 7 C-atoms distributed within and in the neighborhood of the protein envelope. This result shows that relative to w-bR there are no global structural rearrangements in e-bR at this 3.6 A resolution level. The e-D96N crystal is isomorphous to the e-bR crystal with a smaller (9.2%) overall averaged fractional change in the structure factors. The significant structural differences between e-D96N and e-bR are concentrated at high resolution (5-3.6 A); however, these changes are small as quantified from the 3.6 A resolution e-D96N-e-bR Fourier difference map. The difference map showed no statistically significant peaks or valleys within 5 A in projection from the site of D96 substitution on helix C. Elsewhere within the protein envelope the integrated measure of peaks or valleys was < approximately 3 C-atom equivalents. Thus, our results show that for the isosteric substitution of Asp96 by Asn, the molecular conformation of bR in its ground state is essentially unaltered. Therefore, the known effect of D96N on the slowed M412 decay is not due to ground-state structural perturbations.

Bacteriorhodopsins↗

Complementary mobile-phase optimisation for resolution enhancement in high-performance liquid chromatography.

An optimisation methodology in high-performance liquid chromatography (HPLC) is presented for the selection of two or more mobile phases having an optimal complementary resolution. The complementary mobile phases (CMPs) are selected in such a way that each one resolves optimally only some compounds in the mixture, while the remainder, resolved by the other mobile phase(s), can overlap among them. The methodology is based on the computation of a peak purity measurement for each solute, using an asymmetrical peak model for peak simulation. Two global resolution criteria (product of elementary resolutions and worst elementary resolution) and two methods for solving the problem (a systematic examination of all possible solute arrangements, and the use of genetic algorithms to expedite the calculation time) were used to find the optimal CMPs. The CMP optimisation methodology was applied to the resolution of a mixture of 10 diuretics and beta-blockers, which could not be resolved using a single mobile phase; virtual baseline resolution was achieved, however, with two CMPs.

Algorithms↗

Resolution of inflammation.

Acute inflammatory reactions, in contrast to chronic inflammatory reactions, are usually self-limiting and resolve. We have investigated the resolving phase of a number of immune and non-immune inflammatory reactions induced in the pleural cavity of rats. COX-2 is expressed during resolution of these models. Using carrageenan pleurisy, we showed that this enzyme has a proinflammatory role as the reaction develops but an antiinflammatory role as the lesion resolves. This antiinflammatory role is associated with production of cyclopentenone prostaglandins and the absence of PGE2. Dual COX-1/COX-2 inhibitors or COX-2 inhibitors when given at the peak of the inflammatory response delay resolution, an effect reversed by replacing CyPGs into the pleural space. PGF2alpha like the CyPGs appears to have a role in resolving this reaction. Stress proteins are also induced in a variety of acute inflammatory models during resolution. Heme oxygenase-1 (HO-1) is one such protein so too are members of the hsp70 family. An inducer of HO-1 promotes resolution whereas an inhibitor is proinflammatory. In most cases it appears to be the macrophage that is the source of proteins necessary for resolution to occur. Understanding how proinflammatory pathways switch to the antiinflammatory pathways necessary for resolution to take place may eventually allow the exploitation of endogenous antiinflammatory pathways in the treatment of chronic inflammation.

Animals↗

Accuracy of high-resolution computed tomography in cochlear implantation.

Multichannel cochlear implants are a proven method for the auditory rehabilitation of individuals who have severe-to-profound sensorineural hearing loss. These devices typically require insertion into the scala tympani of the cochlea to provide auditory stimulations. A patent scala provides the best chance for an adequate insertion of the electrode array. Preoperative high-resolution computed tomography imaging has traditionally been used to determine the patency of the scala tympani. Its ability to accurately predict the patency of the cochlea has been questioned in several retrospective studies. A prospective study was undertaken in 28 consecutive individuals undergoing cochlear implant surgery to compare the findings on high-resolution computed tomography with the surgical findings in an attempt to determine high-resolution computed tomography's accuracy. Cochlear obstruction caused by ossification was accurately predicted in six of six individuals but overestimated in the round window region in three individuals. High-resolution computed tomography accurately predicted patent cochleas in 19 individuals. No false-negative results were encountered. In this study sensitivity of high-resolution computed tomography was 100%, and specificity was 86%. High-resolution computed tomography appears to be more helpful than previously reported for determining cochlear patency.

Acoustic Stimulation↗

Dietary essential fatty acids, long-chain polyunsaturated fatty acids, and visual resolution acuity in healthy fullterm infants: a systematic review.

BACKGROUND: Biologically active neural tissue is rich in docosahexaenoic acid (DHA), an omega-3 long-chain polyunsaturated fatty acid (LCPUFA). We conducted a systematic review to examine the nature of discordant results from studies designed to test the hypothesis that dietary DHA leads to better performance on visually-based tasks in healthy, fullterm infants. We also conducted a meta-analysis to derive combined estimates of behavioral- and electrophysiologic-based visual resolution acuity differences and sample sizes that would be useful in planning future research. STUDY DESIGN AND METHODS: Twelve empirical studies on LCPUFA intake during infancy and visual resolution acuity were identified through bibliographic searches, examination of monograph and review article reference lists, and written requests to researchers in the field. Works were reviewed for quality and completeness of information. Study design and conduct information was extracted with a standardized protocol. Acuity differences between groups consuming a source of DHA and groups consuming DHA-free diets were calculated as a common outcome from individual studies; this difference score was evaluated against a null value of zero and then used, with the method of DerSimonian and Laird (Meta-analysis in clinical trials. Control Clin Trials 1986;7:177-188), to derive combined estimates of visual resolution acuity differences within seven age categories. RESULTS OF RANDOMIZED COMPARISONS: The combined visual resolution acuity difference measured with behaviorally based methods between DHA-supplemented formula fed groups and DHA-free formula fed groups is 0.32+/-0.09 octaves (combined difference+/-S.E.M., P=0.0003) at 2 months of age. The direction of this value indicates higher acuity in DHA-fed groups. RESULTS OF NON-RANDOMIZED STUDY DESIGNS: The combined visual resolution acuity difference measured with behaviorally based methods between human milk fed groups and DHA-free formula fed groups is 0.49+/-0.09 octaves (P< or =0.000001) at 2 months of age and 0.18+/-0.08 octaves (P=0.04) at 4 months of age. Acuity differences for electrophysiologic-based measures are also greater than zero at 4 months (0.37+/-0.16 octaves, P=0.02). CONCLUSION: Some aspect of dietary n-3 intake is associated with performance on visual resolution acuity tasks at 2, and possibly, 4 months of age in healthy fullterm infants. Whether n-3 intake confers lasting advantage in the development of visually based processes is still in question.

Bottle Feeding↗

The influence of the resolution and contrast on measuring the articular cartilage volume in magnetic resonance images.

The progression of OA in patients may be followed by measuring the volume of articular cartilage from MR images. We attempted to determine the reproducibility of volume measurements of articular cartilage made from magnetic resonance images of the knees and the dependence of the reproducibility on image resolution and contrast-to-noise. A fat-suppressed 3D technique was used to generate four image sets with different image resolution. Each patient was imaged twice to obtain image pairs at each resolution. To assess the dependence of reproducibility on noise we generated six image sets for each patient by adding noise to the original images and repeating the comparison. On each image set, the femoral, tibial, and patellar cartilage were outlined by a combination of computer and manual methods, and the images were used to calculate the volume of each cartilage plate. Comparing the coefficient of variance between the volume measurements made from the two visits, the volume measurements made from images with the highest resolution (0.275 x 0.275 x 1.0 mm) had the highest reproducibility. The high resolution images of the tibia and femur had the least partial-volume averaging and, as a result, better defined the boundaries between cartilage and adjacent tissues. A different trend was evident for the patella. For studies of osteoarthritis therapies, we recommend using MR images with the highest possible in-plane spatial resolution to provide the most reproducible volume measurements of knee cartilage.

Body Mass Index↗

Examples of marginal resolution of NMR relaxation peaks using UPEN and diagnostics.

The multiexponential inversion program UPEN by the authors [J. Magn. Reson. 1998; 132: 65-77; Ibid. 2000;147:273-85] employs negative feedback to a regularization penalty to implement variable smoothing when both sharp and broad features appear on a single distribution of relaxation times. This allows a good fit to relaxation data that correspond to a sum of decaying exponentials plus random noise, but it usually does not give a good fit to data that are distorted by systematic errors from instrument problems, which can cause erroneous "resolution" or erroneous non-resolution of peaks. UPEN provides a series of diagnostic parameters to help identify such data problems that can lead to interpretation errors, and, in particular, to warn when a close call on the resolution or non-resolution of nearby peaks might be questionable. Examples are given from a series of T(2) data sets from desiccated bone samples, with examples where the presence of two peaks is required by good data, examples where the presence of two peaks is negated by good data, and examples where the resolution or non-resolution of peaks cannot be trusted because of instrumental distortions revealed by UPEN diagnostic parameters. It is suggested that processing relaxation data with UPEN in nearly real time could permit retaking data while a sample is still available if the diagnostic parameters show instrumental problems.

Bone and Bones↗