PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “SHOULDER FRACTURES”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12Linked to original sources

Two-part and three-part fractures: open reduction and internal fixation versus closed reduction and percutaneous pinning.

Surgical management of two-part and three-part proximal humerus fractures is difficult and requires familiarity with more than one method of fixation. Poor bone quality, comminution, and the deforming forces of the rotator cuff on the tuberosities influence the choice of operative approach and fixation techniques. Closed reductions and percutaneous pinning offer the potential advantage of minimal soft-tissue dissection; however, good bone quality and minimal comminution are prerequisites. Selected two-part surgical neck fractures and valgus-impacted fractures lend themselves well to this technique. Open reduction and internal fixation is indicated in two-part surgical neck fractures with poor bone quality or extensive comminution, two-part greater tuberosity or lesser tuberosity fractures, and most three-part fractures. The choice of surgical approach is dictated by the fracture pattern and includes an extended deltopectoral approach and a superior deltoid-splitting approach. Fixation techniques are myriad and are dependent on the fracture pattern. Potential fixation methods include intramedullary rods, interfragmentary sutures or wires, and extramedullary plates and screws or blade plates. Successful results are predicated on obtaining adequate enough fixation to allow early passive motion. Results also are influenced by the quality of the reduction and patient compliance.

Bone Nails↗

[Percutaneous surgical treatment of two epiphyseal plate fractures of the proximal humerus].

We report two cases of Salter 2 displaced epiphyseal detachment of the proximal humerus treated successfully by percutaneous reduction and centromedular nailing. This surgical treatment was required because of the irreducibility of the lesion in one patient and instability in the other. This percutaneous technique can be recommended after failure of orthopedic treatment and is an attractive alternative to open surgery.

Adolescent↗

Bone ingrowth into a porous-coated total shoulder component retrieved postmortem.

An uncemented porous-coated humeral component, which functioned in vivo for over 2 1/2 years, was retrieved postmortem and examined histologically. Radiographs of the specimen revealed close approximation to the endosteal cortex medially and laterally. Apposition was limited or absent anteriorly and posteriorly. The overall extent of bone ingrowth was approximately 11% of the available pore volume with over 95% of ingrowth occurring in the medial and lateral quadrants. Bone ingrowth was limited anteriorly and posteriorly to regions in which spot welds were identified radiographically. There were no loose beads or coating failure observed.

Adult↗

Shoulder complications as a cause of delay in rehabilitation of spinal cord injured patients. (Case reports and review of the literature).

We describe ten patients with spinal cord disease or injury who developed upper extremity and shoulder complications during rehabilitation. These shoulder complications caused delay in rehabilitation. We discuss the aetiology, treatment and management of shoulder complications in spinal patients and in patients with other neurological diseases.

Adult↗

[Nuclear magnetic resonance tomography diagnosis of changes in the glenoid process in patients with unstable shoulder joints].

UNLABELLED: In 4 fresh specimens and in 14 healthy volunteers we studied normal anatomy of the glenoid labrum by MRI. In a total of 124 patients we examined the shoulder joints by MRI. 69 patients had any kind of subacromial pathology. 55 patients showed a glenohumeral instability. All MRI findings were compared with the surgical findings during arthroscopy and during open surgery. 44 patients showed a recurrent anterior instability, 7 patients showed a multidirectional instability, 2 patients showed a posterior instability, and 2 patients presented acute anterior dislocation. We found significant variability in the labral shape as well as significant variability of anterior capsular attachment. The pathologic changes of the glenoid labrum were classified in four different types. In 78% we found a concomitant Hill-Sachs lesion of various diameter. 5 patients suffered from an additional complete rotator cuff tear. Compared to the intraoperative findings MRI had a sensitivity of 95%, a specificity of 94%, an accuracy of 94%, a positive predictive value of 91%, and a negative predictive value of 96% in detecting labral pathology. CLINICAL RELEVANCE: Presenting a high diagnostic value for detecting Bankart lesions, MRI may replace other diagnostic modalities like CT-arthrography.

Humans↗

[Indications and results of shoulder arthrodesis and concomitant myoplastic interventions. Follow-up of 60 patients].

From 1949 until 1980 sixty shoulder arthrodeses were performed at the orthopedic department of Heidelberg university. During this period of time a change concerning indication and operative method took part. The increasing number of severe motor cycle accidents with partial injuries of the brachial plexus during the last years makes additional myoplastic operations necessary. The ideal position of the arthrodesis is demonstrated as well results of long term follow ups are repeated.

Arthrodesis↗

The relationship of proximal locking screws to the axillary nerve during antegrade humeral nail insertion of four commercially available implants.

OBJECTIVE: The purpose of this study was to determine the proximity of proximal interlocking mechanisms in 4 current antegrade humeral nails to the axillary nerve and its branches. DESIGN: Cadaveric study. SETTING: Anatomy laboratory. MAIN OUTCOME MEASURE: Anatomic relationships. METHODS: Four humeral nail designs (labeled SS, SL, SZ, and SN) were each inserted in successive antegrade fashion in 10 cadaveric upper extremity specimens. Three variables were measured: from acromion to the axillary nerve, from acromion to entry sites of proximal locking devices, and from locking devices to axillary nerves and their branches. RESULTS: In nail SS, the proximally directed oblique locking screw came into contact with the ascending branch of the axillary nerve in 6 of 10 specimens. Mean distance from spiral blades in nails SS and SL were 26 mm to the axillary nerve and 16 mm to its ascending branch. Interlocking screws for nails SZ, SN, and SL did not violate the axillary nerve or its branches in any specimen. Mean distance from lateral acromion to the axillary nerve measured 58.7 mm. CONCLUSION: Nail SS's oblique locking screw may injure the ascending branch of the axillary nerve. Three of the 4 nails tested did not endanger the axillary nerve. However, when transverse proximal locking screws are inserted from a lateral-to-medial direction, they may endanger an arborized axillary nerve. Blunt dissection should be performed with a visible path to bone before instrumentation to reduce the risk of axillary nerve injury.

Aged↗

Case report: child abuse--necklace calcification--a sign of strangulation.

Strangulation has been postulated as one cause of cerebral hypoxia in child abuse. This report describes the finding of necklace calcification in an infant with rib fractures and a metaphyseal fracture and an admission of a shaking injury. The calcification is likely to represent fat necrosis as the result of strangulation.

Calcinosis↗

Principles of fixation of osteoporotic fractures.

Despite advances in the prevention and treatment of osteoporotic fractures, their prevalence continues to increase. Their operative treatment remains a challenge for the surgeon, often with unpredictable outcomes. This review highlights the current aspects of management of these fractures and focuses on advances in implant design and surgical technique.

Algorithms↗