PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Sample pretreatment”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12Linked to original sources

[Extraction and gas chromatographic analysis of residual trimethylamine(TMA) in the bakelite-type macromolecule complex material].

A method for the determination of residual TMA in the bakelite-type macromolecule complex material has been established. The whole process includes sample pretreatment, TMA extraction and GC analysis. After the samples have been pretreated, the TMA in them was extracted at (38 +/- 2) degrees C for 16 hours. Then the content of TMA in the liquid can be determined directly. From the experimental results we can conclude that the whole method is cheap, simple and accurate. It meets the requirement of microanalysis and can be used to determine real samples.

Air Pollutants↗

High-performance liquid chromatography determination of phenolic components in wine using off-line isotachophoretic pretreatment.

The off-line combination of isotachophoresis (ITP) and high-performance liquid chromatography (HPLC) to improve sample pretreatment and determination of phenolic compounds in wine was investigated. The ITP system provided an enhanced sample load capacity and served as a sample clean-up technique, HPLC performed a final separation of the analytes presented in samples. The phenolic components were separated by Discovery RP Amid C16 chromatography column using water-methanol-acetonitrile-orthophosphoric acid gradient. The identification of phenolic compounds was made by comparison of the retention data obtained for the standard mixture, pretreated sample and the sample spiked standard additions. Satisfactory recoveries for all components analysed were observed between 86.1 and 109.2%.

Chromatography, High Pressure Liquid↗

A direct injection high-throughput liquid chromatography tandem mass spectrometry method for the determination of a new orally active alphavbeta3 antagonist in human urine and dialysate.

A generic high-throughput liquid chromatography (HTLC) tandem mass spectrometry (MS/MS) assay for the determination of compound I in human urine and dialysate (hemodialysis) was developed and validated. By using the HTLC on-line extraction technique, sample pretreatment was not necessary. The sample was directly injected onto a narrow bore large particle size extraction column (50 x 1.0 mm, 60 microm) where the sample matrix was rapidly washed away using a high flow rate (5 mL/min) aqueous mobile phase while analytes were retained. The analytes were subsequently eluted from the extraction column onto an analytical column using an organic-enriched mobile phase prior to mass spectrometric detection. The analytes were then eluted from the analytical column to the mass spectrometer for the determination. The linear dynamic range was 2.0-6000 ng/mL for the urine assay and 0.1-300 ng/mL for the dialysate assay. Intraday accuracy and precision were evaluated by analyzing five replicates of calibration standards at all concentrations used to construct the standard curve. For the urine assay, the precision (RSD%, n=5) ranged from 1.9 to 8.0% and the accuracy ranged from 87.8 to 105.2% of nominal value. For the dialysate assay, the precision (RSD%, n=5) ranged from 1.1 to 10.0% and the accuracy from 94.5 to 105.2% of nominal value. In-source fragmentation of the acyl glucuronide metabolite (compound III) did not interfere with the determination of parent compound I. The developed HTLC/MS/MS methodology was specific for compound I in the presence of compound III. Column life-time is increased and sample analysis time is decreased over traditional reversed-phase methods when direct injection assays for urine and dialysate are coupled with the technology of HTLC.

Chromatography, High Pressure Liquid↗

Solid-phase extraction in malondialdehyde analysis.

Malondialdehyde (MDA) has been widely used as an index of lipoperoxidation in biological and medical sciences as well as in the food industry. A solid-phase extraction (SPE) of the condensation product of the MDA with 2-thiobarbituric acid (TBA) was developed using LiChrolut C18ec, 200 mg (Merck, Darmstadt, Germany), as a SPE cartridge and methanol as an eluent for sample pretreatment before HPLC analysis. The samples of blood plasma, platelet concentrates, or erythrocyte membranes (ghosts) were deproteinized by acetonitrile in the presence of sodium hydroxide prior to the reaction with TBA. The reaction mixture was processed using SPE. The SPE extracts (800 microL of methanol) were put to dryness and after dissolution with 100 microliters of mobile phase, 50 microliters was analyzed by RP-HPLC with fluorescence detection (excitation at 514 nm, emission at 556 nm). The mean MDA concentration in plasmas of 32 healthy donors was 0.37 +/- 0.25 mumol/L and the mean MDA concentration in normal ghosts was 8.3 +/- 4.1 pmol/microgram of protein content. In the case of a patient with a severe form of beta-thalassemia, the concentration of plasma MDA was raised to 1.22 mumol/L and the amount of MDA in erythrocytal ghosts was raised to 21.05 pmol/microgram of protein content. MDA concentration in platelet concentrates (six bags) in the first day of storage was 0.46 +/- 0.18 mumol/L and in the fifth day of storage was 0.55 +/- 0.44 mumol/L.

Blood Platelets↗

[A potentiometric determination of iodide in milk by use of the iron--selective electrode (author's transl)].

A method for quantitative determination of iodide in milk by use of the ion-selective electrode is described. The proposed method is rapid and simple. No sample pretreatment is required exept for sample ionic strength adjustment. It was possible to determine iodide concentrations down to 40 microgram/l with average relative standard deviation of 3,4%. The concentration of iodide in milk samples determined by this method ranged from 61,5 microgram J-/l to 190,8 microgram J-/l.

Animals↗

Determination of oxaliplatin in human plasma and plasma ultrafiltrate by graphite-furnace atomic-absorption spectrometry.

A method for sensitive determination of the anti-cancer agent oxaliplatin in human plasma and human plasma ultrafiltrate (pUF) is presented. The method is based on the quantification of platinum by graphite-furnace atomic-absorption spectrometry, with Zeeman correction and an atomisation temperature of 2,700 degrees C. Sample pretreatment involves dilution of the samples with a solution containing 0.15 mol L(-1) NaCl and 0.20 mol L(-1) HCl in water. Validation was performed in accordance with the most recent FDA guidelines for bioanalytical method validation. All results were within requirements. The validated ranges of quantification were 0.10-400 micromol L(-1) for human pUF and 0.50-400 micromol L(-1) for plasma. The assay is now successfully used to support pharmacokinetic studies of cancer patients treated with oxaliplatin.

Antineoplastic Agents↗

HPLC determination of polydatin in rat biological matrices: application to pharmacokinetic studies.

A reversed-phase high-performance liquid chromatographic (RPHPLC) method has been developed for the determination of polydatin (PD) in rat plasma, bile, urine, feces and tissue homogenates using 2,3,5,4'-tetrahydroxychrysophenine-beta-d-glucoside as an internal standard. The sample pretreatment included deproteinization for plasma samples and a liquid-liquid extraction for bile, urine, feces and tissue homogenates. Separation was obtained on a C18 reversed-phase column with the mobile phase consisting of methanol and water (35:65 v/v). The flow rate was 1 ml/min and the effluent was monitored at 310 nm. The method showed good linearity over the concentration ranges employed for various matrices (r > 0.998). The quantification limits of PD in rat plasma, bile, urine, feces and tissue homogenates were 0.0251, 0.126, 0.025 microg/ml, 0.189 and 0.0378 microg/g, respectively. The accuracy and precision of the method were less than 12.0% for the various matrices. No interferences from endogenous substances were found. The method was successfully applied to study the pharmacokinetics of PD in rats after intravenous administration.

Animals↗

Direct protein detection from biological media through electrospray-assisted laser desorption ionization/mass spectrometry.

We report here using a novel technology-electrospray-assisted laser desorption ionization (ELDI)/mass spectrometry-for the rapid and sensitive detection of the major proteins that exist in dried biological fluids (e.g., blood, tears, saliva, serum), bacterial cultures, and tissues (e.g., porcine liver and heart) under ambient conditions. This technique required essentially no sample pretreatment. The proteins in the samples were desorbed using a pulsed nitrogen laser without the assistance of an organic matrix. The desorbed protein molecules were then post-ionized through their fusion into the charged solvent droplets produced from the electrospray of an acidic methanol solution; electrospray ionization (ESI) proceeded from the newly formed droplets to generate the ESI-like protein ions. This new ionization approach combines some of the features of electrospray ionization with those of matrix-assisted laser desorption ionization (MALDI), that is, sampling of a solid surface with spatial resolution, generating ESI-like mass spectra of the desorbed proteins, and operating under ambient conditions.

Animals↗

Revised direct radiocarbon dating of the Vindija G1 Upper Paleolithic Neandertals.

The 1998/1999 direct dating of two Neandertal specimens from level G(1) of Vindija Cave in Croatia to approximately 28,000 and approximately 29,000 radiocarbon ((14)C) years ago has led to interpretations concerning the late survival of Neandertals in south-central Europe, patterns of interaction between Neandertals and in-dispersing early modern humans in Europe, and complex biocultural scenarios for the earlier phases of the Upper Paleolithic. Given improvements, particularly in sample pretreatment techniques for bone radiocarbon samples, especially ultrafiltration of collagen samples, these Vindija G(1) Neandertal fossils are redated to approximately 32,000-33,000 (14)C years ago and possibly earlier. These results and the recent redating of a number of purportedly old modern human skeletal remains in Europe to younger time periods highlight the importance of fine chronological control when studying this biocultural time period and the tenuous nature of monolithic scenarios for the establishment of modern humans and earlier phases of the Upper Paleolithic in Europe.

Anthropology↗

Line probe assay for monitoring drug resistance in hepatitis B virus-infected patients during antiviral therapy.

Since the introduction of antiviral compounds such as lamivudine and famciclovir in the treatment schedules of patients with chronic hepatitis B virus (HBV) infection, the accumulation of a variety of mutations in the HBV polymerase gene has been observed. The selection of these mutations is generally considered the cause of viral nonresponsiveness and treatment failure. Therefore, the detection of these mutations is of clinical importance. Previously genotyped HBV strains isolated from treated and untreated patients were amplified with primers specific for the HBV polymerase region from amino acids 465 to 562. Amplified products were cloned into plasmid vectors. The clones were used as reference strains. A set of 38 highly specific oligonucleotide probes covering three different codon positions, L528M, M552V/I, and V/L/M555I, were selected. These probes were applied as 19 different lines on a membrane strip. The strips were then hybridized with PCR fragments from the reference panel, revealing the amino acids at the three codon positions simultaneously for each clone. PCR products generated from two patients infected with HBV genotypes A and C, respectively, and treated with nucleoside analogs were analyzed on these strips. A gradual increase in genetic HBV polymerase complexity was observed in follow-up samples compared to that in pretreatment samples. Additional analysis of HBV polymerase DNA fragments in recombinant plasmid clones demonstrated the existence of (i) clones with double mutations, (ii) clones with single mutations at either codon 528, 552, or 555, and (iii) the simultaneous occurrence of two or more viral populations within one sample. This line probe assay detected the complex quasispecies nature of HBV and provided some insight into the dynamics of resistance mutations.

Amino Acid Sequence↗

Use of capillary electrophoresis methods to characterize the pharmacokinetics of antisense drugs.

As antisense drugs become mature for clinical trials, analytical techniques to analyze antisense DNA in biological media for characterization of their pharmacokinetics will be in demand. Due to the superior resolving power of capillary gel electrophoresis (CGE), CGE will likely be a preferred method in quantifying intact oligonucleotides as well as the putative metabolic products. Nonetheless, biological mediums can influence the stability of the gel column, making a CGE assay time-consuming. In one approach, high-performance liquid chromatography (HPLC) was used to quantify the total amount of antisense compounds to increase the sample throughput and CGE was used to determine the relative percentage of the intact and metabolic species on specific samples. Alternatively, extensive sample pretreatment procedures were performed and the samples were quantified and characterized directly by CGE alone with the use of an internal standard. Both methods have been used to characterize the pharmacokinetics of antisense compounds. This review focuses on the instrumental and technical aspects of analyzing antisense DNA in biological mediums using CGE either as a single or a combined method towards better understanding of the pharmacokinetics of antisense DNA. Moreover, the newer analytical technologies of capillary electrophoresis (CE), which hold great potential to be used for pharmacokinetic applications, such as the replenishable sieving matrix combined with an innovative coupling approach and microchip CE, will also be explored.

Animals↗

Effect of NaOH on large-volume sample stacking of haloacetic acids in capillary zone electrophoresis with a low-pH buffer.

Large-volume sample stacking (LVSS) is an effective on-capillary sample concentration method in capillary zone electrophoresis, which can be applied to the sample in a low-conductivity matrix. NaOH solution is commonly used to back-extract acidic compounds from organic solvent in sample pretreatment. The effect of NaOH as sample matrix on LVSS of haloacetic acids was investigated in this study. It was found that the presence of NaOH in sample did not compromise, but rather help the sample stacking performance if a low pH background electrolyte (BGE) was used. The sensitivity enhancement factor was higher than the case when sample was dissolved in pure water or diluted BGE. Compared with conventional injection (0.4% capillary volume), 97-120-fold sensitivity enhancement in terms of peak height was obtained without deterioration of separation with an injection amount equal to 20% of the capillary volume. This method was applied to determine haloacetic acids in tap water by combination with liquid-liquid extraction and back-extraction into NaOH solution. Limits of detection at sub-ppb levels were obtained for real samples with direct UV detection.

Acetates↗

Automated latex nephelometric immunoassay for the measurement of serum lipoprotein (a).

A sensitive immunoassay based on latex particle agglutination has been developed for measuring lipoprotein Lp(a) concentrations in serum or plasma. Carboxylated latex particles (diameter 240 nm) covalently coated with F(ab')2 fragments of anti-lipoprotein Lp(a) antibodies are incubated with diluted sample (400-fold) for 12 min at room temperature, with the resulting agglutination quantified by measuring the change of light-scatter produced. The assay has been automated on the Behring nephelometer analyzer with a sampling rate of 150 samples/hour. This assay generates a standard curve in the range of 27 to 1750 mg/L, showing inter-assay precision of less than 8%. There were no interferences from plasminogen, bilirubin, Intralipid, haemoglobin, rheumatoid factor, and apolipoprotein B. No significant differences were observed when fresh and frozen samples were compared. Sample pretreatment with "Lipoclean" clearing agent and sample lyophilization decreased the agglutinating reaction. In two separate studies using 77 and 112 patient sera the Lp(a) values, determined by the latex nephelometric method, the Terumo Macra Lp(a) ELISA test, and the Pharmacia Apo(a) radioimmunoassay method, gave correlation coefficients of 0.948 and 0.974, respectively. Physiological lipoprotein (a) values were determined in a blood donor group, with the distribution of serum Lp(a) highly skewed, with a mean (SD) and median values of 213(236) mg/L and 116 mg/L, respectively. Concentrations of Lp(a) were found to be age- and sex-independent. This latex nephelometric procedure is a convenient method and an interesting alternative to other immunoassays for routine measurement of human lipoprotein (a).

Adult↗

Enhancement in biodegradability of distillery wastewater using enzymatic pretreatment.

A combined treatment technique consisting of enzymatic hydrolysis, followed by aerobic biological oxidation was investigated for the treatment of alcohol distillery spent wash. The enzyme cellulase was used for the pretreatment step with an intention of transforming the complex and large pollutant molecules into simpler biologically assimilable smaller molecules. Batch experiments were performed in order to analyze the influence of various parameters like pretreatment time, enzyme concentration and pH during the pretreatment step on the subsequent aerobic oxidation kinetics. The rate of aerobic oxidation was enhanced by 2.3 fold for the pretreated sample as compared to the untreated sample when the pH during the pretreatment step was maintained at a value of 4.8. Similarly, a two fold increase in the aerobic oxidation rate was found when the effluent was pretreated with the enzyme, without any pH control (i.e. effluent pH of 3,8). The study indicated that the enzymatic pretreatment of the effluent could be one of the successful pretreatments which can lead to enhancement of the rate of the subsequent aerobic oxidation.

Aerobiosis↗

Determination of apomorphine in human plasma by alumina extraction and high-performance liquid chromatography with electrochemical detection.

Apomorphine is a powerful agonist of dopaminergic receptors which several years ago was introduced into the therapy of Parkinson's Disease. The pharmacological activity of apomorphine already appears significant at low doses. Unfortunately, the difficulty in determining the drug in plasma at low concentrations hampers the completion of accurate pharmacokinetic studies in humans. Considering the analogy of apomorphine with the molecular structure of catecholamines, the extraction of the drug from plasma was optimized by using adsorption on alumina, a technique widely used for noradrenaline and adrenaline analysis in clinical chemistry laboratories. This method proved particularly efficient and selective in apomorphine extraction from plasma prior to high-performance liquid chromatographic analysis. After pretreatment of 200 microliters of plasma sample with 40 mg of alumina and 10 microliters of tris buffer (pH 8.6), the drug was eluted with 200 microliters of an acidic-organic solution. One volume of the supernatant was mixed with two volumes of phosphate buffer (pH 3.6), and 100 microliters of the obtained mixture were injected into the HPLC system. The chromatograph was equipped with a C18 reversed-phase column and with an electrochemical coulometric detector fitted with a high-sensitivity cell (first electrode 0.00 volts, second electrode +0.35 volts). Sensitivity (20 pg of injected drug), precision (CV within assay and between assays of 3.7% and 5.6%, respectively) and accuracy were comparable to more complex analytical procedures. The miniaturisation of the entire sample pretreatment proved very advantageous for pharmacokinetics studies and, in principle, for therapeutic drug monitoring and toxicological investigations.

Adsorption↗

Application of photoassisted electrochemical detection to explosive-containing environmental samples.

High-performance liquid chromatography (HPLC) with ultraviolet (UV) absorbance and photoassisted electrochemical detection (PAED) is applied to the determination of explosives in groundwater and soil samples. On-line, solid-phase extraction minimizes sample pretreatment, enabling direct analysis of groundwater samples and soil extracts. Soils are extracted using pressurized fluid extraction, which is compared to the Environmental Protection Agency (EPA) sonication method. Limits of detection for explosives in the matrixes of interest are equivalent or superior (i.e., <10 parts-per-trillion for HMX) to those achieved using the EPA method 8330. HPLC-UV-PAED is also shown here to be more broadly applicable, as it is capable of determining nitro compounds of interest (e.g., nitroglycerin) that have poor UV chromophores. Additional selectivity of amine-substituted nitroaromatic explosives is achieved by using a photochemical reactor with a 366-nm wavelength lamp. By coupling reversed-phase columns of different selectivities together, baseline resolution of all 14 standard explosives is demonstrated.

Chromatography, High Pressure Liquid↗

Analysis of plant sterol and stanol esters in cholesterol-lowering spreads and beverages using high-performance liquid chromatography-atmospheric pressure chemical ionization-mass spectroscopy.

Plant sterol and stanol esters were separated on a Luna hexyl-phenyl column using a gradient of acetonitrile (90-100%) in water. The eluted compounds were detected by atmospheric pressure chemical ionization (APCI)-mass spectroscopy (MS) in the positive mode. Sterol and stanol esters produced [M + H - HOOCR](+) ions. Application of the hyphenated technique-LC-MS-allowed differentiation between a number of esters of sitosterol, campesterol, stigmasterol, and (tentatively) avenasterol, as well as sitostanol and campestanol esters. With cholesteryl decanoate used as the internal standard, the method showed good linearity, precision, and reproducibility. The method required minimal sample pretreatment and can be applied to samples with high water content (juices) as well as samples with high oil content (margarine spreads). The method could be useful for the analysis of sterol and stanol esters in fortified food products.

Anticholesteremic Agents↗

Arsenic speciation based on ion exchange high-performance liquid chromatography hyphenated with hydride generation atomic fluorescence and on-line UV photo oxidation.

An on-line method capable of the separation of arsenic species was developed for the speciation of arsenite As(III), arsenate As(V), monomethylarsenic (MMA) and dimethylarsenic acid (DMA) in biological samples. The method is based on the combination of high-performance liquid chromatograph (HPLC) for separation, UV photo oxidation for sample digestion and hydride generation atomic fluorescence spectrometry (HGAFS) for sensitive detection. The best separation results were obtained with an anion-exchange AS11 column protected by an AG11 guard column, and gradient elution with NaH2PO4 and water as mobile phase. The on-line UV photo oxidation with 1.5% K2S2O8 in 0.2 mol L(-1) NaOH in an 8 m PTFE coil for 40 s ensures the digestion of organoarsenic compounds. Detection limits for the four species were in the range of 0.11-0.15 ng (20 microL injected). Procedures were validated by analysis of the certified reference materials GBW09103 freeze-dried human urine and the results were in good agreement with the certified values of total arsenic concentration. The method has been successfully applied to speciation studies of blood arsenic species with no need of sample pretreatment. Speciation of arsenic in blood samples collected from two patients after the ingestion of realgar-containing drug reveals slight increase of arsenite and DMA, resulting from the digestion of realgar.

Arsenates↗