Effects of knowledge of isometric strength during performance on recorded strength.
Explore the source record for details and available documents.
SEARCH · PubMed Health
Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The popularity of base metal alloy for porcelain fused to a metal crown and bridges has increased recently because of lower price, superior yield strength and modulus of elasticity (rigidity). The use of these alloys give them the potential advantage of thinner coping with less material and the required rigidity for long-span fixed partial dentures. The addition of beryllium to base metal alloys increases fluidity and improves casting fit. Beryllium also controls surface oxidation and bonding strength. Oxidation heat treatment of the metal is used to remove entrapped air, eliminate organic material and form the metal oxidized layer. The bonding agent and gold bonding agent also affect the bonding strength between porcelain and metal alloys. Four commercially available ceramic base alloys (two alloys contain beryllium element, another two do not) are studied. The purposes of this investigation are to test the shear bond strength between porcelain and metal alloy under different conditions (oxidized layer removed or not, gold bonding agent and uniseal bonding agent used in combination, separately or not at all). The following results were obtained: 1. Whether the oxidized layer was removed or not did not have a significant effect on the bond strength of porcelain (p > 0.05). 2. When different metal alloys was used, Wiron 88 alloy showed significantly the best bond strength of all alloys tested (p < 0.05). 3. When different bonding agent were used, the combination of bonding agent and gold bonding agent showed the best bond strength of all bonding agents tested. It showed a significantly higher bonding strength than opaque layer and gold bonding agent. 4. Vita porcelain powder showed a significantly higher bond strength than did Unibond porcelain (p < 0.05). 5. When opaque layer was used and when no bonding agent was used, the porcelain powder significantly affected the bond strength (p < 0.0001). The Vita porcelain showed a significantly higher bond strength than did Unibond porcelain. Wiron 88 alloy showed significantly the high bond strength than Rexillium III alloy (p < 0.05). 6. When bonding agent was used, the porcelain powder and alloy significantly affected bond strength. The Vita porcelian showed a significantly higher bond strength than did Unibond porcelain. Wiron 88 alloy showed significantly the best bond strength than other alloys Wiron (p < 0.05). 7. When bonding agent and gold bonding agent were used, the porcelain powder significantly affected the bond strength (p < 0.05). The Vita porcelain showed a significantly higher bond strength than did Unibond porcelain (p < 0.05). 8. When gold bonding agent was used, there was not any bond strength between metal and powder.
In order to examine the effectiveness and safety of hydraulic resistance strength training in young males, 26 pre-pubertal males (mean age = 8.2 +/- 1.3 yr) completed a 14-wk strength training study. Subjects were evaluated before and after the 14-wk experimental period for pubertal state (Tanner's sexual maturity rating, serum testosterone, and serum dihydroepiandrosterone sulfate). Effectiveness of the strength training program was determined by measuring pre-post differences in: isokinetic strength for flexion and extension at the knee and elbow joints at two speeds (30 degrees and 90 degrees X s-1) (KIN COM, Chattecx, Inc., Chattanooga, TN), flexibility, standing long jump, vertical jump, body composition parameters, maximal oxygen consumption, and creatinine phosphokinase. Safety of strength training was assessed by biphasic musculoskeletal scintigraphy before and after the program and by physician evaluation of complaints by subjects. Strength training subjects (N = 16) participated in a 45 min/session, 3 session/wk, 14-wk supervised strength training program with an attendance rate of 91.5%. Participants performed concentric work using hydraulic resistance equipment (Hydra-Fitness Industries, Belton, TX). Eccentric work was not performed. Control subjects (N = 10) did not strength train but did participate in sport activities and activities of daily living. Results indicated that strength training subjects increased isokinetic strength as a result of strength training (average concentric work/repetition increases by 18.5 to 36.6% for the eight motions tested; torque scores over the first 90% of the range of motion increases by 13.1 to 45.1% for the eight motions tested). These changes were significantly greater than changes seen in the control group (P less than 0.05). Strength training subjects also demonstrated significant improvements (as compared to control subjects) in vertical jump (+10.4%), flexibility (+8.4%), and maximal oxygen consumption [+19.4% (l X min-1), +13.8% (ml X kg X min-1)] after the experimental period. Musculoskeletal scintigraphy revealed no evidence of damage to epiphyses, bone, or muscle as a result of strength training. Only one strength training-related injury was reported (left shoulder pain, 3 strength training sessions missed). In contrast, six strength training subjects sustained injuries during activities of daily living, resulting in 47 missed strength training sessions. It was concluded that, in the short term, supervised concentric strength training using hydraulic resistance equipment is safe and effective in pre-pubertal boys.
OBJECTIVE: Little is known of the long-term effects of GH replacement therapy on muscle strength in elderly adults with adult onset GH deficiency (GHD). In this study, the effects of 5 years of GH replacement therapy on muscle function were determined in adults over 60 years of age with adult onset GHD. DESIGN: A prospective, open-label, single-centre study. Patients Twenty-six (12 male and 14 female) consecutive hypopituitary adults with adult onset GHD, mean age 65.0 (range 61-74) years. MEASUREMENTS: Upper leg muscle strength was measured using a Kin-Com dynamometer. Right and left handgrip strength were measured using an electronic grip force instrument. RESULTS: The mean insulin-like growth factor-I (IGF-I) SD score increased from -1.10 at baseline to 1.21 at end of the study. Body weight was unchanged during the 5-year study. A sustained increase in lean body mass and a sustained reduction of body fat was observed as measured using dual-energy X-ray absorptiometry (DEXA). The GH replacement therapy induced a sustained increase in isometric (60 degrees ) knee flexor strength. After statistical correction for age and sex variables using observed/predicted value ratios, a sustained increase was also observed in concentric knee flexor strength at an angular velocity of 60 degrees /s, concentric knee extensor strength at 60 degrees /s and 180 degrees /s, and peak right handgrip strength. At baseline, knee flexor strength was 90-96% of predicted, knee extensor strength was 85-87% of predicted, and hand-grip strength was 74-80% of predicted values. At study end, knee flexor strength was 98-106% of predicted, knee extensor strength was 90-100% of predicted, and hand-grip strength was 80-87% of predicted values. CONCLUSION: Elderly patients with adult onset GH deficiency had decreased baseline muscle strength also after correction for age and sex. The 5-year GH replacement therapy normalized knee flexor strength and improved, but did not fully normalize, knee extensor strength and handgrip strength.
Two- and one-leg extension strengths were compared in 155 female and male, untrained and trained (eight bicyclists, 38 weight-lifters) subjects and in a polio patient with almost no strength in one leg. On average two-leg strength was 82 +/- 1.3% (SE) of the sum of the strength of the right and left legs (leg-strength ratio) with no significant difference between the untrained and trained subjects. In the polio patient two-leg strength was lower than the strength of the strongest leg. A similar leg-strength ratio was found when measurements were made with a knee angle of 150 degrees (n = 128) and 90 degrees (n = 25). The ratio did not change when re-determined after 1 year (n = 9). Moderate changes in the subjects' position during measurements did not affect one-leg strength (n = 13). However, familiarization with the experimental apparatus increased the leg-strength ratio from 80 +/- 2.5% to 97 +/- 2.9% (P less than 0.01) (n = 18). In contrast, two-arm extension strength was similar to the sum of the strength of the right and left arms (n = 15). The results demonstrate that two-leg strength in general is lower than the sum of the strength of the right and left legs, and that this phenomenon is found even after intensive endurance or strength training. However, familiarization with the experimental apparatus can increase the relative two-leg strength which suggests that muscle strength in man may be limited by the central nervous systems' ability to activate maximally all synergistic muscles and/or to control antagonistic muscles.
The effects of detraining subsequent to strength training on neuromuscular function were examined in 39 recent-onset rheumatoid arthritis (RA) patients. Eighteen age- and sex-matched healthy people (H) served as controls. Patients were randomly allocated either to the experimental group (PE), who carried out progressive strength training for 6 months, or to the control group (PC), who maintained only their habitual physical activities. After 6 months, PE returned to their earlier physical activities and strength training was terminated. At baseline, the maximal strength of the trunk extensors (not significant), grip strength and maximal dynamic strength and the shape of the force-time curve of the knee extensors were lower in PE and PC (P < 0.05-0.001) than in H. Strength training in PE led to remarkable increases (P < 0.05-0.001) in the maximal strength of all muscle groups without changes in the shape of the force-time curve. The increases in muscle strength in PE obtained by strength training were lost to a great degree during the detraining period for the isometric trunk extension (P < 0.01) and flexion (P < 0.01) strength and for the dynamic knee extension strength (P < 0.05), but not for the grip strength. In PC, trunk extension and flexion strength decreased significantly throughout the study period. At the post-test, all the strength values in both patient groups were much lower than in H. RA is a chronic disease which seems to need continuous physical exercise with sufficient intensity to minimize/prevent the loss of muscle strength and functional capacity.
PURPOSE: The goal of this study was to evaluate strength and functional capacity before and after anterior cruciate ligament (ACL) reconstruction to determine the influences of preoperative strength deficit, graft type, and gender, as well as their clinical relevance in predicting postsurgical recovery and determining the postoperative rehabilitation program. METHODS: This was a retrospective review of prospectively collected uniform data from a group of 191 patients undergoing ACL reconstruction. We assessed functional capabilities and strength of the quadriceps and hamstring at 60 degrees/s and 180 degrees/s by use of a Cybex II dynamometer (Lumex, Ronkonkoma, NY) before and 6, 9, and 12 months after surgery. RESULTS: There was a preoperative quadriceps strength deficit and a decreased limb symmetry index in patients with an ACL deficiency. This strength deficit increased postoperatively, with the highest measured deficit occurring at 6 months postoperatively and a clear improvement from 6 to 12 months. Functional assessment showed identical development. There was a statistically significant relation between an increased quadriceps strength deficit preoperatively and poor early postoperative functional performance. For the bone-patellar tendon-bone (BPTB) group, there was an increased quadriceps strength deficit compared with the semitendinosus and gracilis tendon (STG) group, and the STG group had an increased hamstring strength deficit on postoperative testing. The postoperative hamstring strength deficit is significantly increased in female patients. CONCLUSIONS: All of these data suggest that quadriceps strength deficit is related to the ACL injury and is increased by ACL reconstruction. Even 1 year after ACL reconstruction, a quadriceps strength deficit of almost 20% persists. Flexion strength is within the normal range before and after surgery. These results are influenced by graft choice, with a higher quadriceps strength deficit for BPTB grafts. STG grafts induce a higher hamstring strength deficit compared with BPTB grafts. Functional assessment is improved at 9 and 12 months postoperatively compared with preoperatively regardless of graft type. However, an increased preoperative quadriceps strength deficit results in a lower limb symmetry index at 6 and 9 months postoperatively. LEVEL OF EVIDENCE: Level IV, therapeutic case series.
PURPOSE: In-vitro bond strengths of 3 denture base resins (Trutone, Lucitone 199, and Triad) to a nickel-chromium-beryllium removable partial denture alloy (Ticonium) were tested with 3 surface pretreatments: sandblast, acid etch, and Rocatec (silica blasting), with or without primers (Dentsply, CR inlay cement, and Super Bond). MATERIAL AND METHODS: Lucitone 199 denture base resin bonded to the nonprimed sandblasted alloy specimen served as the control group. Alloy specimens were prepared, surface treated, and primed or not primed with primer. The treated specimens were then packed and processed with the denture base resin. Bonded specimens were stored in the distilled water at 37 degrees C for 24 hours, and then debonded in tension. The force at which the bond failed was noted, and bond strength was calculated in megapascals (MPa). Five replications for each condition (180 specimens total) were tested. RESULTS: Significant differences in bond strength were observed with primer, the most important factor, followed by pretreatment and denture base resin. Without primer for all 3 denture base resins, the Met-Etch and Rocatec treated group showed significantly higher bond strengths than the sandblasted groups. For Trutone denture base resin, nonprimed treated groups produced significantly higher bond strength than those for the other 2 denture base resin, nonprimed treated groups produced significantly higher bond strength than those for the other 2 denture base resins. The control group had zero bond strength. For Dentsply primer, the Rocatec treated group bonded to Lucitone 199 resin produced the highest bond strength value (14.8 +/- 1.8 MPa). For CR inlay cement, the Met-Etch and Rocatec treated groups for Lucitone denture base resin demonstrated the highest bond strength (19.3 +/- 4.8 MPa, and 19.3 +/- 1.8 MPa, respectively). For super Bond primer, the Met-Etch treated group for Trutone resin demonstrated the highest bond strength (19.8 +/- 6.2 MPa). CONCLUSIONS: Without primer, the control had the lowest bond strength (0 MPa), and the Trutone groups showed the highest bond strength (11.7 +/- 4.1 MPa). Met-Etch and Rocatec treated groups produced higher bond strengths than the sandblasted groups. The primed specimens demonstrated significantly higher bond strengths than nonprimed specimens, except for Trutone resin, for which primed specimens produced lower bond strengths than the nonprimed specimens.