PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “biosensor”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12Linked to original sources

A biosensor for the detection of gas toxicity using a recombinant bioluminescent bacterium.

A whole-cell biosensor was developed for the detection of gas toxicity using a recombinant bioluminescent Escherichia coli harboring a lac::luxCDABE fusion. Immobilization of the cells within LB agar has been done to maintain the activity of the microorganisms and to detect the toxicity of chemicals through the direct contact with gas. Benzene, known as a representative volatile organic compound, was chosen as a sample toxic gas to evaluate the performance of this biosensor based on the bioluminescent response. This biosensor showed a dose-dependent response, and was found to be reproducible. The immobilizing matrices of this biosensor were stored at 4 degrees C and were maintained for at least a month without any noticeable change in its activity. The optimal temperature for sensing was 37 degrees C. A small size of this sensor kit has been successfully fabricated, and found to be applicable as a disposable and portable biosensor to monitor the atmospheric environment of a workplace in which high concentrations of toxic gases could be discharged.

Benzene↗

Biosensors.

Advances in biosensor technology over the past year have included developments in metalized electrodes, mediated electrochemistry, direct electron transfer, impedance measurement, optical immunosensors, optodes, biomimicry, piezoelectric biosensors, enzyme thermistors, in vivo biosensors, surface characterization, organic-phase biosensors and tissue-based biosensors. Increasingly, molecular biology and engineering are being used in sensor design.

Biomedical Engineering↗

Aspartame optical biosensor with bienzyme-immobilized eggshell membrane and oxygen-sensitive optode membrane.

An aspartame optical biosensor has been fabricated by employing a bienzyme system composed of alpha-chymotrypsin and alcohol oxidase immobilized onto an eggshell membrane and an oxygen-sensitive optode membrane as the transducer. The detection schemes involve the enzymatic reactions of aspartame leading to the depletion of the oxygen level of the medium with a concomitant enhancement of the fluorescence intensity of the oxygen-sensitive membrane. The scanning electron and transmission electron micrographs show the microstructure of the eggshell membrane which is successfully immobilized with bienzyme. Using this novel immobilization technique, the aspartame biosensor shows extremely good stability with a shelf life of at least 8 months. The rate change of the fluorescence intensity in 4 min is found to be linearly related to the concentration of aspartame. The useful analytical working range of the biosensor is from 0.056 to 3.07 mM aspartame. The effects of temperature, pH, and ionic strength on the response of the aspartame biosensor are investigated in detail. Citric acid, cyclamic acid, D-fructose, D-galactose, D-glucose, hydrogen peroxide, DL-malic acid, L-phenylalanine, saccharin, sodium benzoate, and sucrose show no interferences but ethanol interferes strongly. The aspartame biosensor has been applied to determine aspartame contents in some commercial products.

Animals↗

A method to construct a third-generation horseradish peroxidase biosensor: self-assembling gold nanoparticles to three-dimensional sol-gel network.

A novel method for fabrication of horseradish peroxidase biosensor has been developed by self-assembling gold nanoparticles to a thiol-containing sol-gel network. A cleaned gold electrode was first immersed in a hydrolyzed (3-mercaptopropyl)-trimethoxysilane (MPS) sol-gel solution to assemble three-dimensional silica gel, and then gold nanoparticles were chemisorbed onto the thiol groups of the sol-gel network. Finally, horseradish peroxidase (HRP) was adsorbed onto the surface of the gold nanoparticles. The distribution of gold nanoparticles and HRP was examined by atomic force microscopy (AFM). The immobilized horseradish peroxidase exhibited direct electrochemical behavior toward the reduction of hydrogen peroxide. The performance and factors influencing the performance of the resulting biosensor were studied in detail. The resulting biosensor exhibited fast amperometric response (2.5 s) to H2O2. The detection limit of the biosensor was 2.0 micromol L(-1), and the linear range was from 5.0 micromol L(-1) to 10.0 mmol L(-1). Moreover, the studied biosensor exhibited high sensitivity, good reproducibility, and long-term stability.

Biosensing Techniques↗

Internal response correction for fluorescent whole-cell biosensors.

Whole-cell biosensors based on reporter genes are finding a variety of applications in analytical chemistry. Despite their ability to selectively recognize the analyte in a complex mixture, few applications of such sensing devices to real sample analysis are reported. This is mainly due to nonspecific effects on the biosensor response caused by components of the sample matrix and by environmental changes. To overcome this problem, a bacterial biosensor with an internal correction mechanism of the analytical response was developed by introducing an additional reporter gene that provides a reference signal of the analytical performance of the biosensor. The first reporter (GFPuv), expressed in response to the concentration of L-arabinose, provides the analytical signal; the second reporter (EYFP), constitutively expressed if a constant amount of IPTG is added to each sample, was used as an internal reference. By inducing the biosensor with varying amounts of L-arabinose and a constant amount of IPTG, it was possible to obtain a dose-response curve for L-arabinose, together with a constant production of EYFP, which allowed for a dynamic evaluation of the metabolic activity of the cell. When tested in nonoptimal conditions (e.g., in the presence of either ethanol or deoxycholic acid at toxic concentrations), the presence of the internal reference system corrected the analytical response due to nonspecific interferences.

Arabinose↗

Real-time quantification of methanol in plants using a hybrid alcohol oxidase-peroxidase biosensor.

An amperometric biosensor immobilizing two enzymes and an electron mediator in an identical plane has been fabricated by the self-assembly technique for determination of methanol in crude plant samples. A self-assembled mixed monolayer of 4,4'-dithiodibutyric acid covalently attached two enzymes (Hansenula sp. alcohol oxidase and horseradish peroxidase) and 11-ferrocenyl-1-undecanethiol as an electron mediator on an Au electrode is exploited to produce a two-dimensional reaction matrix. The composition of the two enzymes and electron mediator molecules was optimized for detection of methanol in 0.1 M sodium phosphate buffer (pH 6.0). We successfully quantified methanol in low-purity tobacco (Nicotiana tabacum) plant extracts with the biosensor, which showed sensitivity comparable to that of gas chromatography/mass spectrometry. The redox-relay biosensor is quite simple and stable due to its covalent attachment to the Au surface, making it possible to downsize the construction. We fabricated a miniature methanol biosensor that fitted a well of a 96-well micro assay plate available for high-throughput assay. The biosensor is advantageous for the sensitive, continuous, and convenient determination of methanol.

Alcohol Oxidoreductases↗

General strategy for biosensor design and construction employing multifunctional surface-tethered components.

Biosensors function by reversibly linking bioreceptor-target analyte binding with closely integrated signal generation and can either continuously monitor analyte concentrations or be returned to baseline readout values by removal of analyte. We present an approach for producing fully reversible, reagentless, self-assembling biosensors on surfaces. In the prototype biosensor, quencher-dye-labeled biotin-linked E. coli maltose binding protein (MBP) bound in a specific orientation to a NeutrAvidin-coated surface is employed as a bioreceptor. To complete sensor formation, a modular tether arm consisting of a flexible biotinylated DNA oligonucleotide, a fluorescence resonance energy-transfer (FRET) donor dye, and a distal beta-cyclodextrin (beta-CD) analyte analogue is bound in an equimolar amount to the same surface by means of DNA-directed immobilization. After self-assembly, a baseline level of FRET quenching is observed due to specific interaction between the beta-CD of the flexible tether arm and the sugar binding site of MBP, which brings the two dyes into proximity. Addition of the target analyte, the nutrient maltose, displaces the linked beta-CD-dye of the DNA-based tether arm, and a concentration-dependent change in FRET results. Biosensor sensitivity and dynamic range can be controlled by either using MBP variants having different binding constants or by binding of modulator DNA oligonucleotides that are complementary to the flexible DNA tether. The sensor can be regenerated and returned to baseline quenching levels by washing away analyte. A complex set of interactions apparently exists on the sensing surface that may contribute to sensor behavior and range. This approach may represent a general way to assemble a wide range of useful biosensors.

Base Sequence↗

Nitric oxide-releasing sol-gel particle/polyurethane glucose biosensors.

A hybrid sol-gel/polyurethane glucose biosensor that releases nitric oxide is developed and characterized. The biosensor consists of a platinum electrode coated with four polymeric membranes including the following: (1) sol-gel with immobilized glucose oxidase (GOx); (2) polyurethane to protect the enzyme; (3) NO donor-modified sol-gel particle-doped polyurethane; and (4) polyurethane. This configuration was developed due to the drastic reduction in sensitivity observed for NO donor-modified sol-gel film-based glucose sensors. For the hybrid sol-gel/polyurethane biosensor, sol-gel particles are first modified with the NO donor and then incorporated into a polyurethane layer that is coated onto the preimmobilized GOx electrode. In this manner, the GOx layer is not exposed to the harsh conditions necessary to impart NO release ability to the biosensor, and only a minimal decrease in sensitivity due to the NO release is observed. The glucose response of the NO-releasing glucose biosensor and its NO generation profiles are reported. In addition, the stability of the sol-gel particles in the supporting polyurethane membrane is discussed.

Biosensing Techniques↗

Third-generation biosensor for lactose based on newly discovered cellobiose dehydrogenase.

The present paper describes the principle and characteristics of a biosensor for lactose based on a third-generation design involving cellobiose dehydrogenase. As resulted from a previous comparative study (submitted manuscript), the novelty of this lactose biosensor is based on highly efficient direct electron transfer between two newly discovered cellobiose dehydrogenases (CDH), from the white rot fungi Trametes villosa and Phanerochaete sordida, and a solid spectrographic graphite electrode. CDH was immobilized on the electrode surface (0.073 cm2) by simple physical adsorption, and the CDH-modified electrode was next inserted into a wall-jet amperometric cell connected on-line to a flow injection setup (0.5 mL x min(-1)). The P. sordida CDH-based lactose biosensor, proved to be the better one, has a detection limit for lactose of 1 microM, a sensitivity of 1100 microA x mM(-1) x cm(-2), a response time of 4 s (the time required to obtain the maximum peak current), and a linear range from 1 to 100 microM lactose (correlation coefficient 0.998). The simplicity of construction and analytical characteristics make this CDH-based lactose biosensor an excellent alternative to previous lactose biosensors reported in the literature or commercially available. The CDH-lactose sensor was used to quantify the content of lactose in pasteurized milk, buttermilk, and low-lactose milk, using the standard addition method. No effects of the samples matrixes were observed. The operational stability of the sensor was tested for 11 h by continuous injection of 100 microM lactose (290 injections). The final signal of the sensor was maintained at 98% of its initial signal, with a low standard deviation of 1.72 (RSD 2.41%).

Animals↗

Microfluidic biosensor for the serotype-specific detection of dengue virus RNA.

The development of a microfluidic biosensor with fluorescence detection for the rapid, sensitive, and serotype-specific detection of Dengue virus is presented. The biosensor chip consists of poly(dimethylsiloxane) (PDMS) substrate with fabricated microchannels and a glass substrate used to seal the microchannels. These two substrates are packaged within a pressure-closed Plexiglas housing to provide a watertight reversible sealing at the PDMS-glass interface. The ability to reversibly seal the device permits easy disassembly and quick interchange of the device parts, which is ideal for developmental purposes. The biosensor employs a magnetic bead-based sandwich hybridization system in conjugation with liposome amplification for the specific detection of nucleic acids. The concentrations of the various biosensor components were optimized using a synthesized fragment of Dengue virus RNA. To evaluate the sensitivity of the assay, two detection systems, based on fluorescence measurements of intact and lysed liposomes, were analyzed. The entire analysis was complete within 20 min (including incubation time) with RNA detection limits of 0.125 nM and 50 pM for intact and lysed liposome detection systems, respectively. Subsequently, the biosensor was applied to the analysis of actual RNA obtained from Dengue virus serotypes 1-4. The resulting signals were compared to those obtained using standard electrochemiluminescence detection and shown to correspond perfectly with respect to serotype identification.

Base Sequence↗

Biosensor based on self-assembling acetylcholinesterase on carbon nanotubes for flow injection/amperometric detection of organophosphate pesticides and nerve agents.

A highly sensitive flow injection amperometric biosensor for organophosphate pesticides and nerve agents based on self-assembled acetylcholinesterase (AChE) on a carbon nanotube (CNT)-modified glassy carbon (GC) electrode is described. AChE is immobilized on the negatively charged CNT surface by alternatively assembling a cationic poly(diallyldimethylammonium chloride) (PDDA) layer and an AChE layer. Transmission electron microscopy images confirm the formation of layer-by-layer nanostructures on carboxyl-functionalized CNTs. Fourier transform infrared reflectance spectrum indicates the AChE was immobilized successfully on the CNT/PDDA surface. The unique sandwich-like structure (PDDA/AChE/PDDA) on the CNT surface formed by self-assembling provides a favorable microenvironment to keep the bioactivity of AChE. The electrocatalytic activity of CNT leads to a greatly improved electrochemical detection of the enzymatically generated thiocholine product, including a low oxidation overvoltage (+150 mV), higher sensitivity, and stability. The developed PDDA/AChE/PDDA/CNT/GC biosensor integrated into a flow injection system was used to monitor organophosphate pesticides and nerve agents, such as paraoxon. The sensor performance, including inhibition time and regeneration conditions, was optimized with respect to operating conditions. Under the optimal conditions, the biosensor was used to measure as low as 0.4 pM paraoxon with a 6-min inhibition time. The biosensor had excellent operational lifetime stability with no decrease in the activity of enzymes for more than 20 repeated measurements over a 1-week period. The developed biosensor system is an ideal tool for online monitoring of organophosphate pesticides and nerve agents.

Acetylcholinesterase↗

Fluorescence-based siderophore biosensor for the determination of bioavailable iron in oceanic waters.

With direct evidence that iron is the chemical limitation of phytoplankton growth, particularly in the Southern Ocean, it is increasingly important to develop new tools that provide direct measurement of the bioavailable iron fraction in oceanic waters. Here we report the development of a fluorescence quenching-based siderophore biosensor capable of the in situ measurement of this ultratrace Fe(III) fraction at ambient pH ( approximately 8). Parabactin was extracted from cultures of Paracoccus denitrificans. The purified siderophore was encapsulated within a spin-coated sol-gel thin film, which was subsequently incorporated in a flow cell system. The parabactin biosensor has been fully characterized for the detection of Fe(III) in seawater samples. The biosensor can be regenerated by lowering the pH of the flowing solution, thereby releasing the chelated Fe(III), enabling multiple use. The LOD of the biosensor was determined to be 40 pM, while for an Fe(III) concentration of 1 nM, a reproducibility with a RSD of 6% (n = 10) was obtained. The accuracy of the biosensing system has been determined through analysis of a certified seawater reference sample. Samples from the Atlantic Ocean have been analyzed using the parabactin biosensor providing a concentration vs depth profile for the bioavailable Fe(III) fraction in the 50 pM-1 nM range.

Biological Availability↗

Construction of a fusion enzyme system by gene splicing as a new molecular recognition element for a sequence biosensor.

A bifunctional fusion enzyme system constructed by gene splicing is proposed as a new model to develop sequence biosensors, taking maltose biosensor as an example. The cDNA fragment of Aspergillus niger glucoamylase (E.C 3.2.1.3, GA) was fused to the 3' end of Aspergillus niger glucose oxidase (E.C 1.1.3.4, GOD) gene with the insertion of a flexible linker peptide [-(Ser-Gly)5-] coding sequence. The fusion gene was cloned into the vector pPIC9 and expressed in Pichia pastoris GS115 under the control of the AOX1 promoter. It was found that a bifunctional hybrid protein with a molecular weight of 430 kDa was secreted after induction with methanol. The fusion enzyme GOD-(Ser-Gly)5-GA (GLG) was purified using Q Sepharose Fast Flow ion-exchange chromatography. Kinetic analysis demonstrated that GLG retained the typical kinetic properties of both GA and GOD. After being immobilized on an aminosilanized glass slide through covalent bonding by glutaraldehyde, GLG showed much higher sequential catalytic efficiency than the mixture of separately expressed GA and GOD (GA/GOD). Maltose biosensors were fabricated with GLG and GA/GOD, respectively. The performance characteristics of the maltose biosensor with respect to reproducibility, signal level, and linearity were effectively improved by using the fusion enzyme. Our findings offer a basis for the development of other sequence biosensors.

Artificial Gene Fusion↗

Detection of glucose and related analytes by biosensors: a fractal analysis.

A fractal analysis is used to model the binding and dissociation kinetics of connective tissue interstitial glucose, adipose tissue interstitial glucose, insulin, and other related analytes on biosensor surfaces. The analysis provides insights into diffusion-limited analyte-receptor reactions occurring on heterogeneous biosensor surfaces. Numerical values obtained for the binding and the dissociation rate coefficients are linked to the degree of heterogeneity or roughness (fractal dimension, Df) present on the biosensor chip surface. The binding and dissociation rate coefficients are sensitive to the degree of heterogeneity on the surface. For example, for the binding of plasma insulin, as the fractal dimension value increases by a factor of 2.47 from Df1 equal to 0.6827 to Df2 equal to 1.6852, the binding rate coefficient increases by a factor of 4.92 from k1 equal to 1.0232 to k2 equal to 5.0388. An increase in the degree of heterogeneity on the probe surface leads to an increase in the binding rate coefficient. A dual-fractal analysis is required to fit the binding kinetics in most of the cases presented. A single fractal analysis is adequate to describe the dissociation kinetics. Affinity (ratio of the binding to the dissociation rate coefficient) values are also presented. Interferents for glucose such as uric acid and ascorbic acid were also detected using glucose biosensors based on carbon nanotube (CNT) nanoelectrode ensembles (NEEs) (29) (Lin, Y.; Lu, F.; Tu, Y.; Ren, Z. Nano Lett. 2004, 4 (2), 191-195). Attempts are made to standardize biosensor properties in terms of diffusion characteristics on in vivo responsiveness.

Acetaminophen↗

Dual-fractal analysis for antigen--antibody binding kinetics for biosensor applications.

The diffusion-limited binding kinetics of antigen (or antibody) in solution to antibody (or antigen) immobilized on a biosensor and other surfaces is analyzed within a fractal framework. Often, the binding kinetics may be described by a single-fractal analysis. In some cases, the binding curve exhibits complexities. Then, for these cases, the dual-fractal analysis provides an improved fit when compared with a single-fractal analysis. This indicates a change in the reaction mechanism on the surface. It is of interest to note that the state of disorder (or the fractal dimension) and the binding rate coefficient both increase as the reaction progresses on the biosensor surface. For example, for the binding of 10 nM insulin growth factor-1 in solution to insulin growth factor binding protein-1 immobilized on a biosensor surface, a 64% increase in the fractal dimension from 1.73 (Df1) to 2.85 (Df2) leads to an increase in the binding rate coefficient by a factor of 31.8 from 3.92 (k1) to 125 (k2). Furthermore, as the IGF-1 concentration in solution increases from 10 to 80 nM in solution, k2 and Df2 exhibit a linear increase. k1 and Df1 exhibit a linear increase with the reciprocal of the IGF-1 concentration in solution. The different examples analyzed and presented together provide a means by which the antigen-antibody reactions may be better controlled by noting the magnitude of the changes in the fractal dimension and in the binding rate coefficient as the reaction progresses on the biosensor surface. Also, the magnitude of the changes in the binding rate coefficients (k1 and k2) and in the fractal dimensions (Df1 and Df2) as different parameters are changed for the different biosensor applications are of particular value, since they provide us with a measure or extent of changes in the binding rate coefficient on changing different experimental parameter values. It is of interest to note the effect of different parameters on the extent or heterogeneity that exists on the surface and how this influences the binding rate coefficients. This may be one method to help manipulate or control the binding rate coefficients on the reaction surface.

Antigen-Antibody Complex↗

Fiber-optic enzyme biosensor for direct determination of organophosphate nerve agents.

A fiber-optic enzyme biosensor for the direct measurement of organophosphate nerve agents was developed. The basic element of this biosensor is organophosphorus hydrolase immobilized on a nylon membrane and attached to the common end of a bifurcated optical fiber bundle. The enzyme catalyzes the hydrolysis of organophosphate compounds to form stoichiometric amounts of chromophoric products that absorb light at specific wavelengths. The back-scattered radiation of the specific incident radiation was measured using a photomultiplier detector and correlated to the organophosphate concentration. The effects of buffer pH, temperature, and the units of enzyme immobilized on the steady-state and kinetic response of the biosensor were investigated to optimize the operating conditions for the fiber-optic enzyme biosensor. These conditions were then used to measure parathion, paraoxon, and coumaphos selectively without interference from carbamates and triazines. Concentrations as low as 2 microM can be measured in less than 2 min using the kinetic response. When stored in buffer at 4 degreesC the biosensor shows long-term stability.

Biosensing Techniques↗

Designing 129Xe NMR biosensors for matrix metalloproteinase detection.

Xenon-129 biosensors offer an attractive alternative to conventional MRI contrast agents due to the chemical shift sensitivity and large nuclear magnetic signal of hyperpolarized (129)Xe. Here, we report the first enzyme-responsive (129)Xe NMR biosensor. This compound was synthesized in 13 steps by attaching the consensus peptide substrate for matrix metalloproteinase-7 (MMP-7), an enzyme that is upregulated in many cancers, to the xenon-binding organic cage, cryptophane-A. The final coupling step was achieved on solid support in 80-92% yield via a copper (I)-catalyzed [3+2] cycloaddition. In vitro enzymatic cleavage assays were monitored by HPLC and fluorescence spectroscopy. The biosensor was determined to be an excellent substrate for MMP-7 (K(M) = 43 microM, V(max) = 1.3 x 10(-)(8) M s(-1), k(cat)/K(M) = 7,200 M(-1) s(-1)). Enzymatic cleavage of the tryptophan-containing peptide led to a dramatic decrease in Trp fluorescence, lambda(max) = 358 nm. Stern-Volmer analysis gave an association constant of 9000 +/- 1,000 M(-1) at 298 K between the cage and Trp-containing hexapeptide under enzymatic assay conditions. Most promisingly, (129)Xe NMR spectroscopy distinguished between the intact and cleaved biosensors with a 0.5 ppm difference in chemical shift. This difference most likely reflected a change in the electrostatic environment of (129)Xe, caused by the cleavage of three positively charged residues from the C-terminus. This work provides guidelines for the design and application of new enzyme-responsive (129)Xe NMR biosensors.

Amino Acid Sequence↗

Electrochemical estimation of the polyphenol index in wines using a laccase biosensor.

The use of a laccase biosensor, under both batch and flow injection (FI) conditions, for a rapid and reliable amperometric estimation of the total content of polyphenolic compounds in wines is reported. The enzyme was immobilized by cross-linking with glutaraldehyde onto a glassy carbon electrode. Caffeic acid and gallic acid were selected as standard compounds to carry out such estimation. Experimental variables such as the enzyme loading, the applied potential, and the pH value were optimized, and different aspects regarding the operational stability of the laccase biosensor were evaluated. Using batch amperometry at -200 mV, the detection limits obtained were 2.6 x 10(-3) and 7.2 x 10(-4) mg L(-1) gallic acid and caffeic acid, respectively, which compares advantageously with previous biosensor designs. An extremely simple sample treatment consisting only of an appropriate dilution of wine sample with the supporting electrolyte solution (0.1 mol L(-1) citrate buffer of pH 5.0) was needed for the amperometric analysis of red, rosé, and white wines. Good correlations were found when the polyphenol indices obtained with the biosensor (in both the batch and FI modes) for different wine samples were plotted versus the results achieved with the classic Folin-Ciocalteu method. Application of the calibration transfer chemometric model (multiplicative fitting) allowed that the confidence intervals (for a significance level of 0.05) for the slope and intercept values of the amperometric index versus Folin-Ciocalteu index plots (r = 0.997) included the unit and zero values, respectively. This indicates that the laccase biosensor can be successfully used for the estimation of the polyphenol index in wines when compared with the Folin-Ciocalteu reference method.

Biosensing Techniques↗