PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “coupling”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12Linked to original sources

A comparison of the quantitative methods for the analysis of the platinum-containing anticancer drug [cis-[amminedichloro(2-methylpyridine)]platinum(II)] (ZD0473) by HPLC coupled to either a triple quadrupole mass spectrometer or an inductively coupled plasma mass spectrometer.

The use of high performance liquid chromatography coupled with inductively coupled plasma mass spectrometry (HPLC-ICPMS) as means for the quantitative determination of ZD0473, a platinum anticancer drug, and its related biologically active "aqua" compounds in biofluid samples is described. The performance of the resulting HPLC-ICPMS method was compared with that of a conventional HPLC-triple quadrupole mass spectrometer-based (HPLC-MS/MS) system for properties such as limit of detection, linearity, and reproducibility using spiked samples. The methods were then applied to the determination of plasma ultrafitrate concentrations of ZD0473 in dog plasma samples obtained following intravenous and oral administration at 0.5 and 6 mg/kg, respectively. These experiments showed that both methods were capable of providing accurate and precise results but that the HPLC-ICPMS method had advantages of extended linear range and superior sensitivity, providing a limit of quantification of 0.1 ng/mL for ZD0473, as compared to 5 ng/mL using the current HPLC-MS/MS method. In addition, by using a single combined HPLC-ICPMS/MS/MS system, it was possible to determine the relative MS/MS response of the aqua compounds for the first time.

Animals↗

Hydride generation interface for speciation analysis coupling capillary electrophoresis to inductively coupled plasma mass spectrometry.

A novel hydride generation (HG) interface for coupling capillary electrophoresis (CE) with inductively coupled plasma mass spectrometry (ICPMS) is presented in this work. The CE-HG-ICPMS interface was applied to the separation and quantitation of common arsenic species. Lack of a commercially available HG interface for CE-ICPMS led to a three concentric tube design allowing alleviation of back pressure commonly observed in CE-HG-ICPMS. Due to the high sensitivity and element-specific detection of ICPMS, quantitative analysis of As(III), As(V), monomethylarsonic acid, and dimethylarsinic acid was achieved. Optimization of CE separation conditions resulted in the use of 20 mmol L(-1) sodium borate with 2% osmotic flow modifier (pH 9.0) and -20 kV applied potential for baseline resolution of each arsenic species in the shortest time. Hydride generation conditions were optimized through multiple electrophoretic separation analyses with 5% HCl and 3% NaBH(4) (in 0.2% NaOH) determined to be the optimum conditions. After completion of system optimization, detection limits obtained for the arsenic species were less than 40 ng L(-1) with electromigration time precision less than 1% within a total analysis time of 9.0 min. Finally, the interface was used for speciation analysis of arsenic in river and tap water samples.

Arsenic↗

Potential for using isotopically altered metalloproteins in species-specific isotope dilution analysis of proteins by HPLC coupled to inductively coupled plasma mass spectrometry.

The production and evaluation of an isotopically enriched metalloprotein standard for use as a calibrant in species-specific isotope dilution analysis by HPLC coupled to inductively coupled plasma mass spectrometry is described. Using a model system involving the copper-containing protein rusticyanin (Rc) from the bacterium Acido-thiobacillus ferrooxidans, it was possible to demonstrate the analytical conditions that could be used for the measurement of metalloproteins by on-line IDMS analysis. Rc was chosen because it is a well-characterized protein with an established amino acid sequence and can be produced in suitable quantities using a bacterial recombinant system. Three different forms of the protein were studied by organic and inorganic mass spectrometry: the native form of the protein containing a natural isotopic profile for copper, an isotopically enriched species containing virtually all of its copper as the 65Cu isotope, and the nonmetalated apo form. Incorporation of the copper isotopes into the apo form of the protein was determined using a UV-vis spectrophotometric assay and shown to be complete for each of the copper-containing species. The experimental conditions required to maintain the conformational form of the protein with a nonexchangeable copper center were established using +ve electrospray mass spectrometry. A pH 7.0 buffer was found to afford the most appropriate conditions, and this was then used with HPLC-ICP-MS to verify the stability of the copper center by analysis of mixtures of different isotopic solutions. No exchange of the enriched copper isotope from Rc with an added naturally abundant inorganic copper cation was observed under a neutral pH environment, indicating that species-specific ID-MS analysis of metalloproteins is possible.

Acidithiobacillus thiooxidans↗

Characterization of a second-generation focal-plane camera coupled to an inductively coupled plasma Mattauch-Herzog geometry mass spectrograph.

A second-generation Faraday-strip array detector has been coupled to an inductively coupled plasma Mattauch-Herzog geometry mass spectrograph, thereby offering simultaneous acquisition of a range of mass-to-charge ratios. The second-generation device incorporates narrower, more closely spaced collectors than the earlier system. Furthermore, the new camera can acquire signal on all collectors at a frequency greater than 2 kHz and has the ability to independently adjust the gain level of each collector. Each collector can also be reset independently. With these improvements, limits of detection in the hundreds of picograms per liter for metals in solution have been obtained. Some additional features, such as a broader linear dynamic range (over 7 orders of magnitude), greater resolving power (up to 600), and improved isotope ratio accuracy were attained. In addition, isotope ratio precision as low as 0.018% RSD was achieved.

Journal Article↗

Determination of (ultra)trace amounts of arsenic(III) and arsenic(V) in water by inductively coupled plasma mass spectrometry coupled with flow injection on-line sorption preconcentration and separation in a knotted reactor.

A method has been developed for determination of (ultra)trace amounts of As(III) and As(V) in water by flow injection on-line sorption preconcentration and separation coupled with inductively coupled plasma mass spectrometry (ICPMS) using a knotted reactor (KR). The determination of As(III) was achieved by selective formation of the As(III)-pyrrolidine dithiocarbamate complex over a sample acidity range of 0.01-0.7 mol L-1 HNO3, its adsorption onto the inner walls of the KR made from 150-cm-long, 0.5-mm-i.d. PTFE tubing, elution with 1 mol L-1 HNO3, and detection by ICPMS. Total inorganic arsenic was determined after prereduction of As(V) to As(III) in a 1% (m/v) L-cysteine-0.03 mol L-1 HNO3 media. The concentration of As(V) was calculated by difference (the total inorganic arsenic and As(III)). Owing to the group-specific character of the chelating agent, and the use of an efficient rinsing step before elution, the interferences encountered in conventional ICPMS from common major matrix, alkali and alkaline earth metals, and chlorides were eliminated. The presence of organoarsenic species such as monomethylarsonate and dimethylarsinate in water samples had no effect on the results of As(III) and As(V). Thus, the method can be applied to the speciation analysis of inorganic arsenic at submicrogram per liter levels in aqueous solutions with high total content of dissolved solid and/or high content of chlorides. Using a preconcentration time of 60 s and a sample flow rate of 5 mL min-1, an enhancement factor of 22 was achieved in comparison with conventional ICPMS. The time required for a single determination was 200 s. The detection limits (3s) was evaluated to be 0.021 microgram L-1 for As(III) and 0.029 microgram L-1 for total inorganic arsenic. The precision for 14 replicate determinations of 1 microgram L-1 As(III) was 2.8% (RSD) with drift correction and 3.9% (RSD) without drift correction. The concentrations of As(III) and As(V) in synthetic mixtures obtained by the present method were in good agreement with expected values. Results obtained by the proposed method for total arsenic in a river water reference material agreed well with certified and recently reevaluated values. The method was also applied to the speciation analysis of inorganic arsenic in porewaters.

Arsenic↗

Speciation of dissolved iron(III) and iron(II) in water by on-line coupling of flow injection separation and preconcentration with inductively coupled plasma mass spectrometry.

A method has been developed for the speciation of trace dissolved Fe(II) and Fe(II) in water by on-line coupling of flow injection separation and preconcentration with inductively coupled plasma mass spectrometry (ICPMS). Selective determination of Fe(III) in the presence of Fe(II) was made possible by on-line formation and sorption of the Fe(III)-pyrrolidinecarbodithioate (PDC) complex in a PTFE knotted reactor over a sample acidity range of 0.07-0.4 mol L(-1) HCl, elution with 1 mol L(-1) HNO3, and detection by ICPMS. Over a sample acidity range of 0.001-0.004 mol L(-1) HCl, the sum of Fe(III) and Fe(II), i.e., Fe(III + II), could be determined without the need for preoxidation of Fe(II) to Fe(III). The concentration of Fe(II) was obtained as the difference between those of Fe(III + II) and Fe(III). With a sample flow rate of 5 mL min(-1) and a 30-s preconcentration time, an enhancement factor of 12, a retention efficiency of 80%, and a detection limit (3s) of 0.08 microg L(-1) were obtained at a sampling frequency of 21 samples h(-1). The relative standard deviation (n = 11) was 2.9% at the 10 microg L(-1) Fe(III) level. Recoveries of spiked Fe(III) and Fe(II) in local tap water, river water, and groundwater samples ranged from 95% to 103%. The concentrations of Fe(III) and Fe(II) in synthetic aqueous mixtures obtained by the proposed method were in good agreement with the spiked values. The result for total iron concentration in the river water reference material SLRS-3 was in good agreement with the certified value. The method was successfully applied to the determination of trace dissolved Fe(III) and Fe(II) in local tap water, river water, and groundwater samples.

Fresh Water↗

Influence of coupling method on the luminescence properties, coupling efficiency, and binding affinity of antibodies labeled with europium (III) chelates.

A series of chelating 4-(phenylethynyl)pyridines having various 1,3,5-triazin-2-ylamino groups at the para position of the phenyl ring was synthesized. Their europium chelates were coupled to antibodies and the properties of antibody conjugates analyzed by fluorometry and in time-resolved fluorometric immunoassay. The substituents in the triazine ring were observed to have various effects on the chelate luminescence, the labeling properties of the chelates, and the immunoreactivity of labeled antibodies. The series of substituted triazinyl derivatives serves as a model of bioreactive groups that can be applied when certain properties are searched for, such as improved chelate solubilities, minimized internal quenching, different effects on the ligand triplet state, and stipulated coupling reactivities.

Antibodies↗

Ab initio quantum calculation of the diabatic coupling matrix elements for the self-exchange redox couples M(Cp)20/+ (M = Fe, Co; Cp = C5H5).

The diabatic couplings between the metal centers in M(Cp)20/+ (M = Fe, Co; Cp = C5H5) were evaluated using ab initio methods at the Hartree-Fock level of theory. Excellent agreement with the experimental estimate is found for the Fe(Cp)20/+ couple. For Co(Cp)20/+, the calculated numbers are substantially higher than the experimental estimates, suggesting that the latter may represent a considerable underestimate (a possibility mentioned in the experimental publication).

Journal Article↗

Palladium-catalyzed cross-coupling reaction of bis(pinacolato)diboron with 1-alkenyl halides or triflates: convenient synthesis of unsymmetrical 1,3-dienes via the borylation-coupling sequence.

The synthesis of 1-alkenylboronic acid pinacol esters via a palladium-catalyzed cross-coupling reaction of bis(pinacolato)diboron (pin(2)B(2), pin = Me(4)C(2)O(2)) with 1-alkenyl halides or triflates was carried out in toluene at 50 degrees C in the presence of KOPh (1.5 equiv) and PdCl(2)(PPh(3))(2)-2Ph(3)P (3 mol %). The borylation of acyclic and cyclic 1-alkenyl bromides and triflates was achieved in high yields with complete retention of configuration of the double bonds. The method was applied to the one-pot synthesis of unsymmetrical 1,3-dienes via the borylation-coupling sequence.

Alkenes↗

Decarbonylative cross-coupling of cyclic anhydrides: introducing stereochemistry at an sp3 carbon in the cross-coupling event.

Treatment of cyclic anhydrides with stoichiometric amounts of nickel-neocuproine complex generates alkylcarboxylato-nickelalactones upon extrusion of CO. These metalacycles undergo cross-coupling with arylzinc reagents. The generated CO is sequestered in situ by a nickel-dppb complex. The overall sequence effects a secondary sp3(electrophile)-sp2(nucleophile) cross-coupling and allows for control of stereochemistry during the bond-forming event.

Journal Article↗

Unexpected intermolecular pd-catalyzed cross-coupling reaction employing heteroaromatic carboxylic acids as coupling partners.

Aryl-substituted five-membered heteroaromatics have attracted great interest over the past years due to their presence in a large number of pharmaceuticals and natural products. Recently, an advance in the preparation of these scaffolds was achieved by employing a C-H functionalization strategy. This method allows easy access to these biaryl motifs by precluding the necessity of preparing specific coupling partners, although poor regioselectivity is sometimes observed when more than one reactive C-H is present on the substrate. In an effort to circumvent this liability, we envisioned the use of a carboxylic acid moiety as a blocking group that could be later functionalized or removed. Remarkably, the coupling was found to occur exclusively at the position previously occupied by the acid, even in the presence of a reactive C-H group. This selective transformation was also found to proceed with other heteroaromatic carboxylic acids, allowing for the preparation of a variety of aryl-substituted heteroaromatics that would be difficult to obtain via other methods.

Journal Article↗

A new selective approach to 1,1-bis(silyl)-2-arylethenes and 1,1-bis(silyl)-1,3-butadienes via sequential silylative coupling-Heck coupling reactions.

A novel selective route to 1,1-bis(silyl)-1-alkenes has been developed. Sequential one-pot silylative coupling exo-cyclization of 1,2-bis(dimethylvinylsiloxy)ethane followed by the reaction with Grignard reagents leads to the desired 1,1-bis(silyl)ethenes, which are then efficiently coupled in the presence of silver nitrate and palladium acetate with aryl or alkenyl idodides to give the corresponding 1,1-bis(silyl)-2-arylethenes or 1,1,4-trisubstituted 1,3-butadienes with high yield.

Journal Article↗

A general and straightforward route toward diarylmethanes. Integrated cross-coupling reactions using (2-pyridyl)silylmethylstannane as an air-stable, storable, and versatile coupling platform.

[reaction: see text] Pharmacologically important diarylmethane structures have been prepared in a straightforward manner through sequentially integrated Pd-catalyzed cross-coupling reactions. (2-Pyridyl)silylmethylstannane was found to be an air-stable, storable, and versatile coupling platform in this synthetic strategy.

Journal Article↗

Iridium complex-catalyzed highly selective cross [2 + 2 + 2] cycloaddition of two different monoynes: 2:1 coupling versus 1:2 coupling.

[reaction: see text] Highly selective cross [2 + 2 + 2] cycloaddition of two different monoynes is achieved by using a catalytic amount of [Ir(cod)Cl](2) and ligand. The ligand had a considerable effect on the reaction. When 1,2-bis(diphenylphosphino)ethane was used, two molecules of dimethyl acetylenedicarboxylate (DMAD) reacted with one molecule of a monoyne to give the 2:1 coupling product. When 1,2-bis(dipentafluorophenylphosphino)ethane was used instead of dppe, one molecule of DMAD reacted with two molecules of a monoyne to give the 1:2 coupling product.

Journal Article↗

Phosphine-triggered complete chemo-switch: from efficient aldehyde-alkyne-amine coupling to efficient aldehyde-alkyne coupling in water.

[reaction: see text] A phosphine ligand served as a remarkable chemo-switch for the silver-catalyzed reaction of alkynes with aldehydes in the presence of amines in water. Exclusive aldehyde-alkyne-amine coupling product was observed in the absence of phosphine, whereas in the presence of a phosphine ligand, exclusive aldehyde-alkyne coupling product was obtained.

Journal Article↗

Rhodium-catalyzed multicomponent-coupling reactions involving a carborhodation-cross-coupling sequence.

[reaction: see text] A rhodium-catalyzed multicomponent-coupling reaction has been developed that involves a cross-coupling with organohalides as part of the reaction sequence. Through several experiments toward mechanistic investigations, it has also been demonstrated that the reaction most likely proceeds via a carborhodation-oxidative addition-reductive elimination pathway, which clearly contrasts to the corresponding palladium-catalyzed processes.

Journal Article↗

Evaluation of the influence of anisotropic indirect nuclear spin-spin coupling tensors on effective residual dipolar couplings for model peptides.

Residual dipolar couplings (RDCs) observed between nuclear spins in molecules in partially oriented media have become a valuable source of information for NMR spectroscopists seeking to structurally characterize biological macromolecules. Examination of the form of the direct (D) and indirect (J) nuclear spin-spin coupling Hamiltonians indicates that all observed RDCs contain an unknown contribution from the anisotropic part of J (Delta J) in addition to the direct dipolar contribution, DPQ. Here, we evaluate the influence of DeltaJ on RDCs through a series of DFT calculations on model peptides. Very small corrections to one-bond RDCs measured between heavy atoms in peptides and proteins are recommended: +0.51% for N-C' spin pairs, and +0.45% for C alpha-C' spin pairs. The corrections to RDCs involving at least one proton are negligible. This latter point is likely to be equally applicable to nucleic acids and oligosaccharides in addition to peptides and proteins. Finally, the orientations of the J(N, C') and J(C alpha, C') tensors in the molecular framework are reported for glycylglycine.

Anisotropy↗

Determination of arsenic species in fish, crustacean and sediment samples from Thailand using high performance liquid chromatography (HPLC) coupled with inductively coupled plasma mass spectrometry (ICP-MS).

Suitable techniques have been developed for the extraction of arsenic species in a variety of biological and environmental samples from the Pak Pa-Nang Estuary and catchment, located in Southern Thailand, and for their determination using HPLC directly coupled with ICP-MS. The estuary catchment comprises a tin mining area and inhabitants of the region can suffer from various stages of arsenic poisoning. The important arsenic species, AsB, DMA, MMA, and inorganic arsenic (As III and V) have been determined in fish and crustacean samples to provide toxicological information on those fauna which contribute to the local diet. A Hamilton PRP-X100 anion-exchange HPLC system employing a step elution has been used successfully to achieve separation of the arsenic species. A nitric acid microwave digestion procedure, followed by carrier gas nitrogen addition- (N2)-ICP-MS analysis was used to measure total arsenic in sample digests and extracts. The arsenic speciation of the biological samples was preserved using a Trypsin enzymatic extraction procedure. Extraction efficiencies were high, with values of 82-102%(As) for fish and crustacean samples. Validation for these procedures was carried out using certified reference materials. Fish and crustacean samples from the Pak Pa-Nang Estuary showed a range for total arsenic concentration, up to 17 microg g(-1) dry mass. The major species of arsenic in all fauna samples taken was AsB, together with smaller quantities of DMA and, more importantly, inorganic As. For sediment samples, arsenic species were determined following phosphoric acid (1 M H3PO4) extraction in an open focused microwave system. A phosphate-based eluant, pH 6-7.5, with anion exchange HPLC coupled with ICP-MS was used for separation and detection of AsIII, AsV, MMA and DMA. The optimum conditions, identified using an estuarine sediment reference material (LGC), were achieved using 45 W power and a 20 minute heating period for extraction of 0.5 g sediment. The stability and recovery of arsenic species under the extraction conditions were also determined by a spiking procedure which included the estuarine sediment reference material. The results show good stability for all species after extraction with a variability of less than 10%. Total concentrations of arsenic in the sediments from the Pak Pa-Nang river catchment and the estuary covered the ranges 7-269 microg g(-1)and 4-20 [micro sign]g g(-1)(dry weight), respectively. AsV was the major species found in all the sediment samples with smaller quantities of AsIII. The presence of the more toxic inorganic forms of arsenic in both sediments and biota samples has implications for human health, particularly as they are readily 'available'.

Animals↗