PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “ATMOSPHERIC PRESSURE”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13Linked to original sources

Monitoring of olanzapine in serum by liquid chromatography-atmospheric pressure chemical ionization mass spectrometry.

A selective assay of olanzapine with liquid chromatography atmospheric pressure chemical ionization (LC-APCI-MS, positive ions) is described. The drug and internal standard (ethyl derivative of olanzapine) were isolated from serum using a solid-phase extraction procedure (C18 cartridges). The separation was performed on ODS column in acetonitrile-50 mM ammonium formate buffer, pH 3.0 (25:75). After analysis of mass spectra taken in full scan mode, a selected-ion monitoring detection (SIM) was applied with the following ions: m/z 313 and 256 for olanzapine and m/z 327 and 270 for the internal standard for quantitation. The limit of quantitation was 1 microg/l, the absolute recovery was above 80% at concentration level of 10 to 100 microg/l. The method tested linear in the range from 1 to 1000 microg/l and was applied for therapeutic monitoring of olanzapine in the serum of patients receiving (Zyprexa) and in one case of olanzapine overdose. Olanzapine in frozen serum samples and in frozen extracts was stable over at least four weeks. The examinations of urine extracts from patients receiving olanzapine revealed peaks of postulated metabolites (glucuronide and N-desmethylolanzapine).

Antipsychotic Agents↗

Electrosonic spray ionization. A gentle technique for generating folded proteins and protein complexes in the gas phase and for studying ion-molecule reactions at atmospheric pressure.

Electrosonic spray ionization (ESSI), a variant on electrospray ionization (ESI), employs a traditional micro ESI source with supersonic nebulizing gas. The high linear velocity of the nebulizing gas provides efficient pneumatic spraying of the charged liquid sample. The variable electrostatic potential can be tuned to allow efficient and gentle ionization. This ionization method is successfully applied to aqueous solutions of various proteins at neutral pH, and its performance is compared to that of the nanospray and micro ESI techniques. Evidence for efficient desolvation during ESSI is provided by the fact that the peak widths for various multiply charged protein ions are an order of magnitude narrower than those for nanospray. Narrow charge-state distributions compared to other ESI techniques are observed also; for most of the proteins studied, more than 90% of the protein ions can be accumulated in one charge state using ESSI when optimizing conditions. The fact that the abundant charge state is normally as low or lower than that recorded by ESI or nanospray indicates that folded protein ions are generated. The sensitivity of the ionization technique to high salt concentrations is comparable to that of nanospray, but ESSI is considerably less sensitive to high concentrations of organic additives such as glycerol or 2-amino-2-(hydroxymethyl)-1,3-propanediol (Tris base). Noncovalent complexes are observed in the case of myoglobin, protein kinase A/ATP complex, and other proteins. The extent of dissociation of protein ions in ESSI is comparable to or even smaller than that in the case of nanospray, emphasizing the gentle nature of the method. The unique features of ESSI are ascribed to very efficient spraying and the low internal energy supplied to the ions. Evidence is provided that the method is capable of generating fully desolvated protein ions at atmospheric pressure. This allows the technique to be used for the study of ion-molecule reactions at atmospheric pressure and examples of this are shown.

Atmospheric Pressure↗

Microchip atmospheric pressure chemical ionization source for mass spectrometry.

A novel microchip heated nebulizer for atmospheric pressure chemical ionization mass spectrometry is presented. Anisotropic wet etching is used to fabricate the flow channels, inlet, and nozzle on a silicon wafer. An integrated heater of aluminum is sputtered on a glass wafer. The two wafers are jointed by anodic bonding, creating a two-dimensional version of an APCI source with a sample channel in the middle and gas channels symmetrically on both sides. The ionization is initiated with an external corona-discharge needle positioned 2 mm in front of the microchip heated nebulizer. The microchip APCI source provides flow rates down to 50 nL/min, stable long-term analysis with chip lifetime of weeks, good quantitative repeatability (RSD < 10%) and linearity (r(2) > 0.995) with linear dynamic rage of at least 4 orders of magnitude, and cost-efficient manufacturing. The limit of detection (LOD) for acridine measured with microchip APCI at flow rate of 6.2 muL/min was 5 nM, corresponding to a mass flow of 0.52 fmol/s. The LOD with commercial macro-APCI at a flow rate of 1 mL/min for acridine was the same, 5 nM, corresponding to a significantly worse mass flow sensitivity (83 fmol/s) than measured with microchip APCI. The advantages of microchip APCI makes it a very attractive new microfluidic detector.

Atmospheric Pressure↗

Application of atmospheric pressure chemical ionization liquid chromatography-mass spectrometry in identification of lymph triacylglycerols.

Atmospheric pressure chemical ionization liquid chromatography-mass spectrometry was used in the identification of triacylglycerol molecular species in lymph samples from rats given either a structured lipid or safflower oil. The structured lipid was MLM-type (M, medium-chain fatty acid; L, long-chain fatty acid) and manufactured from caprylic acid (8:0) and the oil (safflower oil or high-oleic sunflower oil). The triacylglycerol composition of lymph varied significantly between structured triacylglycerols and safflower oil. Diacylglycerol fragment ions were found for all triacylglycerols and we could also observe the ammonium adduct molecular ion [M+NH4]+ for all the triacylglycerols at the selected conditions. Protonated molecular ions were formed from triacylglycerols containing unsaturated fatty acids, and fatty acid fragment ions were also observed in the case of strong fragmentation. The lymph triacylglycerols were identified from their ammonium adduct molecular ions and diacylglycerol fragment ions. In addition to the intact MLM-type structured triacylglycerols, the MLL- and LLL-type triacylglycerols were also identified. The absorption pathway of MLM-type structured triacylglycerols is most likely the same as that of conventional long-chain triacylglycerols, i.e. they were hydrolyzed into 2-monoacylglycerol and medium-chain fatty acids, which were then used for resynthesis of triacylglycerols. The present study thereby also demonstrates the possibility to study the absorption pathway of triacylglycerol via identification of triacylglycerol species in biological samples.

Animals↗

Quantification of plasma membrane ergosterol of Saccharomyces cerevisiae by direct-injection atmospheric pressure chemical ionization/tandem mass spectrometry.

A method for the quantification of ergosterol by atmospheric pressure chemical ionization (APcI) mass spectrometry with direct injection is described. Ergosterol and squalene were ionizable with methanol as the carrier solvent. Using positive-mode tandem mass spectrometry (MS/MS), ergosterol could be identified unambiguously without interference from structurally related compounds such as lanosterol, cholesterol, and squalene. Molecular ions of ergosterol, lanosterol, and cholesterol were detected as the [M + H - H(2)O](+) ion species, while squalene appeared as the [M + H](+) ion species. Upon fragmentation of the three sterols and squalene, the product ion at m/z 69 was present as one of the major fragments in all four compounds. This product ion was used for the quantification of ergosterol in multiple-reaction-monitoring acquisition mode. The relationship between signal intensity and ergosterol concentration was linear over the concentration range of 0.15 to 5 microg/ml, or 7. 56-252 pmol ergosterol per 20 microl injection. The plasma membrane ergosterol of the yeast Saccharomyces cerevisiae could be quantified reproducibly without the need for prior separation from other lipids or derivatization. Six repeated injections of ergosterol standards at concentrations of 0.95 and 4.25 microg/ml gave standard deviations of 0.031 and 0.084, respectively, and coefficients of variation of 3.33 and 1.98%, respectively. The coefficient of variation for the four independently extracted membrane ergosterol samples was 11.18%. The presence of other lipids in a crude lipid extract did not interfere with the ergosterol determination. Direct injection APcI with multiple reaction monitoring is aconvenient and sensitive method for ergosterol quantification requiring no prior fractionation.

Atmospheric Pressure↗

High-throughput mass spectrometer using atmospheric pressure ionization and a cylindrical ion trap array.

The analytical performance of an atmospheric pressure sampling, multiple-channel, high-throughput mass spectrometer was investigated using samples of a variety of types. The instrument, based on an array of cylindrical ion traps, was built with four independent channels and here is operated using two fully multiplexed channels (sources, ion optics, ion traps, detectors) capable of analyzing different samples simultaneously. Both channels of the instrument were incorporated within the same vacuum system and operated using a common set of control electronics. A multichannel electrospray ionization source was assembled and used to introduce samples including solutions of organic compounds, peptides, and proteins simultaneously into the instrument in a high-throughput fashion. Cross-talk between the channels of the instrument occurred in the detection system and could be minimized to 1-2% using shielding between detector channels. In this initial implementation of the instrumentation, an upper mass/charge limit of approximately 1300 Th was observed (+13 charge state of myoglobin) and unit mass/charge resolution was achieved to approximately 800 Th. The rather limited dynamic range (2-3 orders of magnitude for low-concentration analytes) is due to cross-talk contributions from more concentrated species introduced into a different channel. Analysis of mixtures of alkylamines and peptides is demonstrated, but analysis of mixtures with a wide spread in mass/charge ratios was not possible due to mass discrimination in the ion optics. Further refinement of the vacuum system and ion optics will allow the addition of more channels of parallel mass analysis and facilitate applications in fields such as proteomics and metabolomics.

Amines↗

Stereoselective quantification of methadone and a d(6)-labeled isotopomer using high performance liquid chromatography-atmospheric pressure chemical ionization mass-spectrometry: application to a pharmacokinetic study in a methadone maintained subject.

There is evidence that the apparent oral clearance of rac-methadone is induced during the early phase of methadone maintenance treatment. However, it is not known if this is due to changes in bioavailability or if this phenomenon is stereoselective. This knowledge can be obtained by administering a dose of stable-labeled methadone at selected times during ongoing treatment. Therefore, the authors developed a stereoselective high performance liquid chromatography-atmospheric pressure chemical ionization mass-spectrometry assay for the quantification of the enantiomers of methadone and a d(6)-labeled isotopomer. The compounds were quantified in a single assay after liquid-liquid extraction and stereoselective high performance liquid chromatograph with atmospheric pressure chemical ionization-mass spectrometry detection. The following ions were monitored: m/z 310.15 for unlabeled methadone; m/z 316.15 for methadone-d(6); and m/z 313.15 for the methadone-d(3) (internal standard). Calibration curves ranged from 0.5 to 75 ng/mL for each compound. Extraction recovery was approximately 80% for all analytes, without evidence of differences between the unlabeled and stable-labeled compounds or concentration dependency. Minor ion promotion was observed (<15%) but this was identical for all analytes including the d(3)-labeled internal standard, with peak area ratios in extracted samples identical to control injections. The isotopomers did not alter each others' ionisation, even at 10:1 concentration ratios, and 10-fold diluted samples were within 10% of the nominal concentration. Assay performance was acceptable, with interassay and intra-assay bias and precision <10% for all compounds, including the upper and lower limits of quantitation. In conclusion, the assay was successfully applied to quantify the concentration of the methadone enantiomers of both orally administered unlabeled methadone and an intravenous 5 mg dose of methadone-d(6) in a patient receiving chronic oral methadone maintenance therapy.

Administration, Oral↗

Assay of nicergoline and three metabolites in human plasma and urine by high-performance liquid chromatography-atmospheric pressure ionization mass spectrometry.

A method for the simultaneous determination of nicergoline and three of its metabolites in human plasma and urine has been developed using high-performance liquid chromatography-atmospheric pressure ionization mass spectrometry. Nicergoline and its metabolites were extracted from the plasma and urine samples with chloroform and separated on a reversed-phase ODS column. The eluents were led to the atmospheric pressure ionization interface and then analysed in the selected-ion monitoring mode. The detection limits of nicergoline and three of its metabolites were ca. 2 ng/ml in plasma and ca. 10 ng/ml in urine, at a signal-to-noise ratio of 4.

Chromatography, High Pressure Liquid↗

Growth of wheat under one tenth of the atmospheric pressure.

Wheat plants were grown in twin closed growth chambers under normal and reduced atmospheric pressures. For the first 22 days from sowing, the reduced pressure was maintained at 200 hPa, and at 100 hPa for the remaining 27 days until harvest. These pressures were obtained by evacuation of the chamber and adding oxygen (170 and 79 hPa respectively) and carbon dioxide (0.65 and 1.0 hPa respectively; about 2 and 3 times above the control). Eighty-seven per cent of the final dry mass was produce under 100 hPa treatment. Growth and development of wheat are not negatively affected by low pressure treatment. Compared to the control, final dry mass increased by 76%, leaf number by 133%, and ear number by 35%, probably due to elevation of CO2. Shortening of shoot parts and increases in chlorophyll and proteins content are not in accordance with a predicted CO2 effect and could be attributed to the N2 removal and the subsequent alteration in gas diffusion rate.

Atmospheric Pressure↗

Atmospheric pressure chemical ionisation liquid chromatography/mass spectrometry of the ultraviolet screening pigment scytonemin: characteristic fragmentations.

Atmospheric pressure chemical ionisation reversed-phase high-performance liquid chromatography/multistage mass spectrometry has been used to study the mass spectral fragmentation of the cyanobacterial sheath pigment scytonemin and its reduced counterpart. The two pigments exhibit characteristic fragment ions in their MS2 and MS3 spectra that are of value in confirming the identification of the structures in extracts from natural environments.

Atmospheric Pressure↗

Atmospheric pressure chemical ionisation reversed-phase liquid chromatography/ion trap mass spectrometry of intact bacteriohopanepolyols.

Atmospheric pressure chemical ionisation liquid chromatography/multi-stage ion trap mass spectrometry (APCI-LC/MS(n)) has been applied to the study of intact bacteriohopanepolyols. Spectral characterisation of bacteriohopanepolyols of known structure present in bacterial extracts (Zymomonas mobilis and a fermenter containing methanotrophs including Methylococcus capsulatus) has revealed greater structural detail than previous liquid chromatography/mass spectrometry (LC/MS) methods and identified characteristic fragmentations indicative of numerous biohopanoid structures. Analysis of a Recent sedimentary extract from Lake Druzhby (Antarctica) has demonstrated the power of this technique to detect biohopanoids in complex samples including at least partial characterisation of previously unknown composite structures.

Atmospheric Pressure↗

Determination of the pesticide diflubenzuron in mushrooms by high-performance liquid chromatography-atmospheric pressure chemical ionisation mass spectrometry.

A method using high-performance liquid chromatography-atmospheric pressure chemical ionisation mass spectrometry (HPLC-APCI-MS) has been developed and validated for the determination of the insecticide diflubenzuron [1-(4-chlorophenyl)-3-(2,6-difluorobenzoyl)urea] in mushrooms. Samples were homogenised with acetone, extracted into dichloromethane-cyclohexane and further cleaned-up by size-exclusion chromatography (SEC). HPLC was performed on an ODS column with methanol-water at 1 ml/min. The limit of detection was 0.02 ng/microl (equivalent to 0.017 mg/kg in the crop). The calibration was linear over the range 0.025-1.0 ng/microl. Recovery of diflubenzuron from spiked mushrooms (0.06-0.58 mg/kg) was 85.5% with a relative standard deviation of 14.5% (n = 56).

Atmospheric Pressure↗

Quantification of epimeric budesonide and fluticasone propionate in human plasma by liquid chromatography-atmospheric pressure chemical ionization tandem mass spectrometry.

A highly sensitive and selective liquid chromatography-atmospheric pressure chemical ionization tandem mass spectrometry assay was developed and validated for simultaneous determination of epimeric budesonide (BUD) and fluticasone propionate (FP) in plasma. The drugs were isolated from human plasma using C18 solid-phase extraction cartridges, and epimeric BUD was acetylated with a mixture of 12.5% acetic anhydride and 12.5% triethylamine in acetonitrile to form the 21-acetyl derivatives following the solid-phase extraction. Deuterium-labelled BUD acetate with an isotopic purity >99% was synthesized and used as the internal standard. The assay was linear over the ranges 0.05-10.0 ng/ml for epimeric BUD, and 0.02-4.0 ng/ml for FP. The inter- and intra-day relative standard deviations were <14.3% in the assay concentration range.

Androstadienes↗

Nanoscale atmospheric pressure laser ablation-mass spectrometry.

We describe an atmospheric pressure nanosampling interface for mass spectrometry based on near-field laser ablation. Pulsed laser radiation is delivered to the sample surface through a near-field optical probe, and the ablation plume is sampled through a capillary orifice and analyzed by standard MS methods. A spatial resolution of less than 200 nm and a sensitivity below 2 amol is demonstrated.

Journal Article↗

Atmospheric pressure molecular imaging by infrared MALDI mass spectrometry.

An atmospheric pressure (AP) MALDI imaging interface was developed for an orthogonal acceleration time-of-flight mass spectrometer and utilized to analyze peptides, carbohydrates, and other small biomolecules using infrared laser excitation. In molecular imaging experiments, the spatial distribution of mock peptide patterns was recovered with a detection limit of approximately 1 fmol/pixel from a variety of MALDI matrixes. With the use of oversampling for the image acquisition, a spatial resolution of 40 microm, 5 times smaller than the laser spot size, was achieved. This approach, however, required that the analyte was largely removed at the point of analysis before the next point was interrogated. Native water in plant tissue was demonstrated to be an efficient natural matrix for AP infrared laser desorption ionization. In soft fruit tissues from bananas, grapes, and strawberries, potassiated ions of the most abundant metabolites, small carbohydrates, and their clusters produced the strongest peaks in the spectra. Molecular imaging of a strawberry skin sample revealed the distribution of the sucrose, glucose/fructose, and citric acid species around the embedded seeds. Infrared AP MALDI mass spectrometric imaging without the addition of an artificial matrix enables the in vivo investigation of small biomolecules and biological processes (e.g., metabolomics) in their natural environment.

Journal Article↗

Determination of kava lactones in food supplements by liquid chromatography-atmospheric pressure chemical ionisation tandem mass spectrometry.

Reversed-phase liquid chromatography and detection with atmospheric pressure chemical ionisation tandem mass spectrometry was used for the determination of kava extracts in herbal mixtures. One percent of kava extract can be detected, corresponding to approximately 0.05-0.2 mg/g of the individual kava lactones kavain, dihydrokavain, yangonin, desmethoxyyangonin, methysticin and dihydromethysticin. Reliable quantification is obtained from concentrations of 0.25-1 mg/g, depending on the compound. At these concentration levels, the relative standard deviations were 10-14%. Validation showed good linearity and recoveries for all the kava lactones with the exception of yangonin. During method development, degradation of yangonin was observed. The degradation product was identified by nuclear magnetic resonance (NMR) as cis-yangonin. The method was applied to the analysis of commercial herbal products available in the Dutch market before and after market restrictions of kava-containing preparations. The results showed that even though 'old' products contained kava extract, the new formulations were negative on kava lactones. cis-Yangonin was also present in the herbal products.

Atmospheric Pressure↗

Separation of sodiated isobaric disaccharides and trisaccharides using electrospray ionization-atmospheric pressure ion mobility-time of flight mass spectrometry.

A series of isobaric disaccharide-alditols, four derived from O-linked glycoproteins, and select trisaccharides were rapidly resolved using tandem high resolution atmospheric pressure ion-mobility time-of-flight mass spectrometry. Electrospray ionization was used to create the gas-phase sodium adducts of each carbohydrate. Using this technique it was possible to separate up to three isobaric disaccharide alditols and three trisaccharides in the gas phase. Reduced mobility values and experimentally determined ion-neutral cross sections are reported for each sodium-carbohydrate complex. These studies demonstrated that ion mobility separations at atmospheric pressure can provide a high-resolution dimension for analysis of carbohydrate ions that is complementary to traditional mass spectral (m/z) ion analysis. Combining these independent principles for separation of ions provides a powerful new bioanalytical tool for the identification of isomeric carbohydrates.

Disaccharides↗