PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Biometry”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13Linked to original sources

Relative localizing value of amygdalo-hippocampal MR biometry in temporal lobe epilepsy.

OBJECTIVES: The aims of the study were (i) to examine the localizing value of three MRI quantitative modalities (qMRI) currently used for the analysis of the hippocampus and amygdala in the context of pre-surgical screening and (ii) to propose a step-by-step protocol based on the sensitivity and performance of the different MR techniques. METHODS: Ninety-two adults with chronic mesial temporal lobe epilepsy (TLE) of which 28 underwent amygdalo-hippocampal resection, and 34 age-matched controls were included in the study. High-resolution qMRI was performed at 1.5 T, including a tilted T1-weighted 3D-dataset for volumetry and four-echoes T2 relaxometry (both for hippocampus and amygdala quantifications) and multi-voxel spectroscopy [NAA/(Cho+Cre)] (exclusively in the hippocampus). Individual qMRI data were compared with electroencephalography regarding the localization of the epileptogenic area, with the neuropathological data and with postoperative outcome. MRI pathology was defined based on 99% confidence ellipses. Ten controls were used to assess the quantitative MRI intra- and inter-observer variability for all variables. RESULTS: Volumetric measurements revealed unilateral damage in 77% of the patients, T2-relaxometry in 64% and spectroscopy in 53%. Additional measurements of the amygdalae (T2-relaxometry) allowed us to localize pathology that coexists with that of the hippocampus in 34%, and isolated unilateral amygdala damage in 8% of patients. Volumetry and T2-relaxometry (not spectroscopy) were associated with postoperative outcome, but accurate predictive models were computed based on hippocampal measures only. At least at 1-year follow-up, volumetry predicts outcome correctly in 100% of the cases, whilst T2-relaxometry classified 96.4% (27/28) of these patients. All operated patients had hippocampal sclerosis. CONCLUSIONS: Hippocampal structural damage is equivocally depicted by spectroscopy. For diagnostic and pre-operative evaluation, hippocampal volumetry and T2-relaxometry provide maximal accuracy. Amygdala quantifications are irrelevant in the pre-operative evaluation but may be useful for diagnostic purposes. Of the three qMRI modalities tested, T2-relaxometry provided the best balance between diagnosis accuracy and time-efficiency to lateralize a sclerotic lesion on the majority of the patients. Cases that remain undecided after T2-relaxometry may benefit from additional measurements based on hippocampal volumetry.

Adolescent↗

Anterior chamber angle biometry with ultrasound biomicroscopy after diode laser thermal keratoplasty.

PURPOSE: To evaluate the effect of diode laser thermal keratoplasty (DTK) on the geometry of the anterior chamber angle with ultrasound biomicroscopy (UBM). SETTING: Department of Ophthalmology and Optometry, Paracelsus Private Medical University, Salzburg, Austria. METHODS: In 9 eyes, a Rodenstock DTK (ProLaser Medical Systems) was used to correct hyperopia (n = 6) or hyperopic astigmatism (n = 3). Hyperopia was treated with a single- or double-ring pattern and hyperopic astigmatism, with additional spots in each of the flat half meridians. Ultrasound biomicroscopy measurements of the chamber angle were obtained preoperatively and 3 months postoperatively using a Humphrey UBM 840 system with a 50 MHz transducer. Quantitative measurements were performed at 3-, 6-, 9-, and 12-o'clock positions using a standardized method. RESULTS: No statistically significant differences between the preoperative and postoperative chamber angle measurements were detected. CONCLUSIONS: The results of the UMB measurements were surprising given the flattening of the corneal periphery found by computerized topography, a finding that suggests narrowing of the chamber angle. Shortening of the corneal tissue may result in centripetal traction that affects the trabecular meshwork and results in a relative opening of the chamber angle structures.

Adult↗

Biometry of phakic intraocular lens using Scheimpflug photography.

PURPOSE: To examine lateral and axial positioning of phakic intraocular lenses (IOLs) with iris fixation in the anterior chamber and to examine short-term stability of the IOL position. SETTING: The Netherlands Opthalmic Research Institute, Amsterdam, the Netherlands. METHODS: Thirty patients participated in the study. Thirty-one eyes were implanted with the 204 type myopia IOL, 14 eyes with the 206 myopia IOL, and 8 eyes with the 203 hyperopia IOL. Scheimpflug slitlamp photographs were made through the optical axis along 4 meridians of the eyes. Ray tracing was used to obtain the lateral and axial position of the IOLs. RESULTS: Centration of the IOL with respect to the pupil's center and the tilt angle of the IOL with respect to the optical axis of the eye were measured. Standard deviation of decentration was 0.21 mm vertically and 0.16 mm horizontally. Standard deviation of tilt was 1.30 degrees vertically and 0.90 degrees horizontally. Tilt and decentration are proportional to each other. Vaulting, the distance between the crystalline lens and the IOL, was constant over a period of 24 months, ranging from 0.2 to 0.8 mm, depending primarily on the radius of curvature of the crystalline lens. A geometric model for this dependence was formulated. CONCLUSION: Phakic IOLs with iris fixation can be positioned in the eye with submillimeter precision. Axial position of iris-fixated phakic IOLs over time is excellent. Axial position and vaulting can be predicted when the radius of curvature of the crystalline lens is known. The IOL behaves as if mounted slightly above a sphere-the anterior surface of the crystalline lens.

Biometry↗

Biometry accuracy.

Explore the source record for details and available documents.

Accommodation, Ocular↗

Relationship between retinal detachment and biometry in 4262 cataractous eyes.

PURPOSE: To assess risk factors for retinal detachment (RD) in eyes that previously underwent cataract surgery. DESIGN: Retrospective cohort study. PARTICIPANTS: Four thousand two hundred sixty-four eyes of 3094 patients who underwent extracapsular cataract extraction with intraocular lens (IOL) implantation at the Department of Ophthalmology, Erasmus MC, University Medical Center Rotterdam. METHODS: From January 1, 1993, through March 31, 1999, 3094 patients (4262 cases) of extracapsular cataract extraction with IOL implantation were enrolled. Through review of ophthalmic patient records, the role of preoperative and intraoperative data as well as neodymium:yttrium-aluminum-garnet (Nd:YAG) capsulotomy was assessed with respect to development of an RD. MAIN OUTCOME MEASURES: Axial length (AL), anterior chamber depth (ACD), crystalline lens thickness, mean keratometric power, spherical equivalent, intraoperative complications, Nd:YAG laser posterior capsulotomy, RD. RESULTS: Of 4262 eyes that underwent cataract extraction, 3921 eyes (2794 patients) were available for analysis. Twenty-two patients experienced RD after surgery, resulting in an overall cumulative incidence of 0.62%. Multivariate binary logistic regression analyses showed the following factors to be associated with an increased risk of RD after cataract surgery: an accidental posterior capsular rupture at the time of surgery (odds ratio [OR] = 16.26; P<0.001), an increased AL (OR = 1.25; P = 0.013), and a deeper anterior chamber (OR = 4.02; P = 0.016). Older age was found to be a protective factor for the development of RD (OR = 0.95; P = 0.003). CONCLUSIONS: Cataract surgery at a young age with an accidental posterior capsular rupture and a deeper ACD are the most important predisposing conditions for pseudophakic RD after cataract surgery. The overall cumulative incidence of 0.62% for postoperative RD is low.

Adult↗

Macular pigment and ocular biometry.

This study is designed to investigate the relationship between macular pigment optical density (MPOD) and ocular biometric parameters. The following details were recorded for 180 healthy subjects: demographic profile; best-corrected visual acuity; refractive status; ocular biometric parameters [axial length (AL), anterior chamber depth (ACD), lens thickness (LT) and vitreous chamber depth (VCD)]; ocular dominance; MPOD; serum lutein (L) and zeaxanthin (Z). The mean MPOD (+/-SD) was 0.307 (0.155) and 0.305 (0.149) in the right and left eyes, respectively. No demonstrable relationship was observed between MPOD and AL, ACD or VCD [AL: r=0.091, p=0.225; ACD: r=0.091, p=0.227; VCD: r=0.146, p=0.051]. There was a significant and inverse relationship between LT and MPOD (r=-0.204; p=0.008), which was attenuated to non-significance after correction for age and height (r=-0.058; p=0.466). This study fails to identify an association between MPOD and ocular biometric parameters. This is an important negative finding, which allows investigators to study MP, and its relationship with potentially important variables, without the need to correct for ocular biometric parameters.

Adult↗

Age, gender, biometry, refractive error, and the anterior chamber angle among Alaskan Eskimos.

BACKGROUND: The prevalence of angle-closure glaucoma (ACG) is greater for Eskimos/Inuit than it is for any other ethnic group in the world. Although it has been suggested that this prevalence may be due to a population tendency toward shallower anterior chamber angles, available evidence for other populations such as Chinese with high rates of ACG has not consistently demonstrated such a tendency. METHODS: A reticule, slit-lamp, and standard Goldmann one-mirror goniolens were used to make measurements in the anterior chamber (AC) angle according to a previously reported protocol for biometric gonioscopy (BG) (Ophthalmology 1999;106:2161-7). Measurements were made in all four quadrants of one eye among 133 phakic Alaskan Eskimos aged 40 years and older. Automatic refraction, dilated examination of the anterior segment and optic nerve, and A-scan measurements of AC depth, lens thickness, and axial length were also carried out for all subjects. RESULTS: Both central and peripheral AC measurements for the Eskimo subjects were significantly lower than those previously reported by us for Chinese, blacks, and whites under the identical protocol. Eskimos also seemed to have somewhat more hyperopia. There were no differences in biometric measurements between men and women in this Eskimo population. Angle measurements by BG seemed to decline more rapidly over life among Eskimos and Chinese than blacks or whites. Although there was a significant apparent decrease in AC depth, increase in lens thickness, and increase in hyperopia with age among Eskimos, all of these trends seemed to reverse in the seventh decade and beyond. CONCLUSIONS: Eskimos do seem to have shallower ACs than do other racial groups. Measurements of the AC angle seem to decline more rapidly over life among Eskimos than among blacks or whites, a phenomenon also observed by us among Chinese, another group with high ACG prevalence. This apparent more rapid decline may be due to a cohort effect with higher prevalence of myopia and resulting wider angles among younger Eskimos and Chinese.

Adult↗

Biometry and primary angle-closure glaucoma among Chinese, white, and black populations.

PURPOSE: Primary angle-closure glaucoma (PACG) is more prevalent among Chinese than whites. The authors tested the hypothesis that Chinese have shallower anterior chambers than do whites, a factor that may be related to PACG prevalence. METHODS: The authors compared anterior chamber depth, axial length, radius of corneal curvature, and refractive error among 531 Chinese, 170 whites, and 188 blacks older than 40 years of age using the same model of instruments and identical technique. RESULTS: Mean anterior chamber depth and axial length did not differ significantly for the three groups. Whites had a significantly higher prevalence of hyperopia > 2 diopters than did Chinese. Radius of corneal curvature was significantly smaller among Chinese than whites or blacks. CONCLUSIONS: These results suggest that Chinese do not differ on a population basis from other ethnic groups in many of the biometric risk factors known to be of importance for PACG. It will be necessary to identify other ocular biometric parameters to explain the excess burden of PACG among Chinese, which may improve the effectiveness of screening for this disease in all populations.

Adult↗

Dating biometry during the first trimester: accuracy of an every-day practice.

OBJECTIVE: The goal of this study was to determine the accuracy of an every-day practice for assessing gestational age by ultrasound measurement of the greatest embryonic length (GEL). DESIGN: This retrospective study used measurements taken during the first trimester. SUBJECTS: We considered all births in this hospital between 1 January 1992 and 31 December 1994 from pregnancies that began by an in-vitro fertilization procedure (IVF). We examined 143 consecutive files, containing 257 measurements made by 72 different operators. METHODS: The precision of seven embryo growth curves was compared. We calculated for each curve its ability to predict (95% prediction interval) the date the pregnancy began, using these dated pregnancies. RESULT: For GEL measurements between 3 and 80 mm, which includes most of our population, Robinson and Wisser (2) were the most appropriate curves. The 95% prediction interval was 9.5 and 10.2 days respectively. CONCLUSION: Dating pregnancies in every-day practice with GEL is nearly as accurate as prospective studies with only one or two scanners.

Adult↗

Ultrasonographic biometry in salivary glands.

Specifications about the size of healthy salivary glands are not available to date. Therefore, we determined the size of the submandibular and the parotid glands by ultrasonography in 50 subjects (25 men, 25 women, mean age 45 y, range 20-68) with no history of disease affecting the salivary glands. The subjects were equally distributed concerning gender and age. Body weight did not differ more than 20% from the ideal weight following Broca's formula (mean body weight 71 kg, range 46-95 kg). In the submandibular glands we found an anterior-posterior length of 35 mm +/- 5.7 mm, a paramandibular dimension to the depth of 14.3 mm +/- 2.9 mm and a dimension in frontal scanning of 33.7 mm +/- 5.4 mm. The parotid glands were measured 46.3 mm +/- 7.7 mm in the axis parallel to the mandibular ramus and 37.4 mm +/- 5.6 mm in the transversel axis. The dimension of the parotid parenchyma was measured with 7.4 mm +/- 1.7 mm lateral to the mandible and 22.8 mm +/- 3.6 mm dorsal to the mandible. No statistically significant difference to the 5%-level was found concerning gender. The dimension of the parotid glands correlated statistically significantly with body weight (p = 0.03). This correlation was not found in the dimension of the submandibular glands. Age did not correlate with the dimension of salivary glands. Results of the submandibular glands were compared with volume measurements of submandibular glands from cadavers.

Adult↗

Use of fetal biometry to determine fetal age in late pregnancy in llamas.

Sixty-three pregnant llamas of known breeding date were used in this study. Forty-six of them were submitted to surgery between 186 and 320 days of gestation (52-91% of average gestation period, respectively). Under general anesthesia their fetuses were exteriorized and fetal weight (W), biparietal diameter (BPD) and femoral (F), tarsus-hoof (T-H), tibial (T)) and fronto-occipital (F-O) length were determined. Additionally, the same variables were determined on 16 newborn llamas. The weight was measured in kg and the length in cm. All the collected data was entered into a spreadsheet and different regression analyses as a function of gestational age (GA) were assessed. The best fit equations and their correlation for linear regression were the following: GA=169.448+16.66(*)W, r=0.99; GA=-51.713+44.77(*)BPD, r=0.88; GA=-72.139+39.48(*)F-O, r=0.71; GA=39.304+8.35(*)T-H, r=0.97; GA=91.276+8.23(*)T, r=0.86; GA=102.029+9.94(*)F, r=0.91. For multiple regression, the dependent variable GA can be predicted by the following equation: GA=67.462+11.163(*)W+20.297(*)BPD. Results of the present study indicated measured variables to be highly correlated with GA. This could be useful on daily basis in clinical examination of the neonates, in assessment of fetal growth and well being with cesarean sections, in the determination of GA in late gestation abortions, and in perinatal and reproductive research in the llama.

Animals↗

Effects of refrigeration on the biometry and development of Protophormia terraenovae (Robineau-Desvoidy) (Diptera: Calliphoridae) and its consequences in estimating post-mortem interval in forensic investigations.

The aim of this study was to simulate the low temperatures that insects could experience between the time being sampled from cadavers and their arrival in the laboratory. This was in order to investigate the effect of low temperature on development of maggots. At different stages of development, individuals of Protophormia terraenovae (Robineau-Desvoidy) reared at 24 degrees C were submitted to a temperature of 4.0+/-0.5 degrees C for a period varying from 1 to 10 days. Independent of the stage of development at which the insects were refrigerated, the treatment induced significant changes on the duration of development. The effect of low temperature on the developmental time between the return to 24 degrees C to adult emergence depended on the larval stage that was refrigerated. When first instar larvae and prepupae were refrigerated, the time to emergence at 24 degrees C decreased with an increase of duration of the refrigeration period. Time to emergence increased under the same conditions when second instar larvae and pupae were refrigerated. These results indicate that keeping larvae of P. terraenovae at 4 degrees C does not just simply lead to a cessation of metabolism but disturbs the regular development. Ten days of cooling induced an error in estimating post-mortem interval (PMI) of more than 6h.

Animals↗

Biometry of 3 types of intraocular lenses using Scheimpflug photography.

PURPOSE: To compare differences in intraocular lens (IOL) decentration and tilt and anterior chamber depth (ACD) using Scheimpflug photography as well as best corrected visual acuity (BCVA) in eyes having phacoemulsification with implantation of 1 of 3 types of IOLs. SETTING: Chung-Ang University Hospital, Seoul, Korea. METHODS: This study comprised 137 cataractous eyes of 108 patients having phacoemulsification and IOL implantation. Eyes were randomized into 3 groups based on IOL type: poly(methyl methacrylate) (PMMA) (n = 65); silicone (n = 47); soft acrylic (n = 25). Biometric analysis was performed with an EAS-1000 Scheimpflug camera 1, 3, and 6 months after surgery. Best corrected visual acuity was also measured at these visits. RESULTS: The anterior chamber was deeper 1 month after surgery, with no statistical difference among groups. There were no significant differences among groups in IOL decentration and tilt or final BCVA during the follow-up. CONCLUSIONS: In this study in which a properly constructed continuous curvilinear capsulorhexis was created and IOLs were accurately placed in normal capsular bags, changes in ACD, IOL decentration and tilt, and BCVA were similar in eyes with a PMMA, silicone, or soft acrylic IOL.

Acrylic Resins↗