PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Denture, Partial, Fixed”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13Linked to original sources

Twenty-year experience with 12-unit fixed partial dentures supported by two abutments.

Eleven patients who had only two remaining natural teeth, vital mandibular canines, were treated using experimental 12-unit fixed partial dentures and complete maxillary dentures. The marginal bone support was 60% in one patient and 80% to 100% in the others. The patients were studied for 20 years. After 15 years, seven patients had prostheses that were still functional, two had prostheses that failed, one lost the prosthesis following treatment for oral cancer, and one patient died. Nine of the 22 abutments required endodontic treatment. After 15 years, the fixed partial dentures began to tilt distally and considerable resorption was found under the pontics. The periodontal tissues withstood the increased stress, and the prostheses were stable.

Adult↗

Retrofitting an esthetic post and core to salvage a six-unit fixed partial denture.

Teeth restored with post and core restorations present a clinical dilemma if they fracture. An individual with a maxillary anterior six-unit fixed partial denture had one of the canine abutment teeth fracture. The other abutment debonded and the post separated from the core. The fixed partial denture was salvaged by retrofitting a porcelain-fused-to-metal post and core restoration in the fractured abutment.

Cuspid↗

Tooth structure loss apical to preparations for fixed partial dentures when using self-limiting burs.

STATEMENT OF PROBLEM: Burs with guide pins may be used to limit the depth of tooth preparation for fixed partial dentures. The effects of guide pins on tooth structure apical to the finish line after tooth preparation for fixed partial dentures has not been recorded. PURPOSE: This in vitro study recorded loss of tooth structure within 1.0 mm apical to the finish line of teeth prepared with straight cylinder and tapered cylinder self-limiting burs and one conventional bur. MATERIAL AND METHODS: Forty-five extracted human teeth were randomly divided into three groups. The facial surface of each tooth was prepared with two types of diamond burs with guide pins and a conventional diamond for the control. The surface was profiled before and after tooth preparation. Profiled surfaces were analyzed and the groups were compared using analysis of variance and the Tukey-Kramer HSD test (alpha = 0.05). RESULTS: No significant difference was recorded between the control group and the group prepared with a round-ended tapered cylinder self-limiting pin. However, there was a statistically significant difference between the control and cylindrical pin groups, and between the two groups prepared with self-limiting diamonds. CONCLUSION: This study revealed abrasion apical to the finish line of the preparation in all groups. The cylindrical guide pin group exhibited the greatest loss of tooth surface.

Analysis of Variance↗

A clinical investigation on three-unit fixed partial dentures fabricated with a lithium disilicate glass-ceramic.

A lithium disilicate glass-ceramic material has recently been developed for the fabrication of 3-unit fixed partial dentures. Conducted on 60 restorations, this initial trial attempted to define clinical indications and establish design principles for fixed partial dentures fabricated of this ceramic material. The design requisites varied depending on placement on the arch, and the authors concluded that lithium disilicate restorations caused reduced antagonist structure or opposing tooth wear. This investigation demonstrated that when a novel ceramic system was utilized for 3-unit restorations replacing up to the first premolar and attained minimal criteria for connector dimensions, an acceptable clinical success rate was achieved.

Adult↗

Stress analysis of a cantilevered fixed partial denture with normal and reduced bone support.

A two-dimensional finite element model was constructed to analyze the simulated mechanical behavior of a cantilevered fixed partial denture. The variations of the models were made by altering the degree of bone support, the number of splinted abutments, and the length of the pontics. High stress concentrations were observed around the connectors of the fixed prosthesis and the tooth closest to the cantilever. Reduced bone support increased the deflection and stress concentrations. There was reduction in displacement and stress concentration when the teeth were splinted together. To improve the prognosis of the fixed partial denture cantilever, the number of abutments should be increased and the number of pontics decreased.

Alveolar Bone Loss↗

Stress concentration in all-ceramic posterior fixed partial dentures.

Two-dimensional finite-element analysis was used to study levels and distribution patterns of stress within three-unit fixed partial dentures (mandibular first premolar to first molar) constructed of different materials (Type III gold alloy, Dicor, and In-Ceram) and with different connector heights (3.0 mm versus 4.0 mm). In the computer models, 10 MPa of stress was applied centrally to the prosthesis. Resultant von Mises stresses were concentrated within the connectors; the greatest stress occurred at the axial location of the connector. Stresses were 40% to 50% lower for 4.0-mm connectors. Patterns of stress distribution were similar for premolar and molar connectors. Stress levels within In-Ceram models were lower than for the other two materials and represented a lower percentage of the ultimate strength of the material. Based on a two-dimensional finite-element analysis model, In-Ceram would appear to be the best choice for posterior fixed partial dentures.

Aluminum Oxide↗

Resin-bonded fixed partial dentures. II. Clinical findings related to prosthodontic characteristics after approximately 10 years.

A clinical study was conducted for patients who were functioning with resin-bonded fixed partial dentures for approximately 10 years. The purpose of this study was to evaluate the periodontal health and determine the prosthodontic characteristics of the fixed partial dentures. Results indicated that plaque indexes, probing, recession, and loss of attachment were greater for abutments than for control teeth. The differences were statistically significant but clinically small. The bonded restorations were generally well adapted and contoured for case of cleaning.

Chi-Square Distribution↗

Influence of design and mode of loading on the fracture strength of all-ceramic resin-bonded fixed partial dentures: an in vitro study in a dual-axis chewing simulator.

STATEMENT OF PROBLEM: In a clinical study, all-ceramic resin-bonded fixed partial dentures showed a high rate of fractures within the first years of service but remained in function as cantilevered restorations. No data are available on the fracture strength of such cantilevered restorations. PURPOSE: This in vitro study evaluated the influence of design and mode of loading on the fracture strength of all-ceramic resin-bonded fixed partial dentures. MATERIAL AND METHODS: Forty-eight frameworks were copy milled using the aluminum-oxide ceramic In-Ceram, glass-infiltrated, and circularly veneered with feldspathic porcelain to replace a maxillary incisor on a test cast. The airborne particle-abraded restorations were bonded to acid-etched human abutments using composite. Twenty-four restorations used a conventional 2-retainer design and another 24 restorations used a cantilevered single-retainer design. Subgroups of 8 specimens were subjected to a quasi-static load in the direction of the long axis of the abutments (0 degrees) or in an angle of 45 degrees. Additional subgroups were subjected to dynamic loading under 45 degrees with either 50 or 25 N in a dual-axis chewing simulator until fracture. RESULTS: Mean fracture strengths, under 45-degree quasi-static loading, were between 134 and 174 N and under 0-degree loading about 233 N. Samples subjected to dynamic loading fractured after 25 to over 200,000 loading cycles. CONCLUSION: Direction of loading exhibited a significant influence on the fracture strength, regardless of the retainer design. The applied dynamic loading force, regardless of the retainer design, had a significant influence on the loading cycles until fracture.

Aluminum Oxide↗

Failures related to crowns and fixed partial dentures fabricated in a Nigerian dental school.

The purpose of this investigation was to document the failure rate and length of service of crowns and fixed partial dentures (FPDs) fabricated in a Nigerian dental school. The reasons for failure of the initial restorations and their length of service were also ascertained. Also, the numbers of retainers, pontics, and the types of restoration were recorded. Poor esthetics was the most frequent cause of failure, 66 units (40.5%); followed by fracture, 58 units (35.6%); and dental caries, 25 units (15.4%). These outcomes were contrary to findings previously reported in studies from western countries where dental caries was principally responsible for failures (22.0% to 38.0% of cases). The resin-retained FPDs had the shortest mean years of service at 2.7 years, while the three-unit metal-ceramic FPDs had the greatest longevity at 8.6 years. The overall mean years of service for replaced restorations were 5.6 years. The study found a decrease in the mean years of service as the number of units in the fixed-fixed partial dentures increased. This is in sharp contrast to previous reports where no relationship existed between length of service and the number of units in a FPD.

Adolescent↗

An in vitro study of dentin exposure during resin-bonded fixed partial denture preparation.

OBJECTIVES: The aim of this in vitro study was to investigate whether dentin is exposed during tooth preparation for resin-bonded fixed partial dentures and, if so, to quantify the amount of dentin exposure. METHOD AND MATERIALS: Twenty extracted premolars were prepared in the following manner: The palatolingual and proximal axial surfaces were reduced by 0.50 mm. Mesial and distal grooves, 1.00 mm in depth, and mesial and distal occlusal rest seats, measuring 2.00 mm buccolingually x 1.50 mm mesiodistally x 1.00 mm deep, were prepared. The specimens were stained with a modified van Gieson's stain to identify dentin exposure, mounted on a jig to allow standardization, and photographed after 30-degree rotation to create a panoramic image of each tooth. The image was modified and analyzed to measure the percentage of the preparation area that exhibited dentin exposure. RESULTS: Dentin exposure was noted in all specimens. The mean area of dentin exposure was 11.06 mm2 (16.15% of the preparation area). The minimum and maximum areas of dentin exposure were 4.07 mm2 (7.03%) and 19.73 mm2 (27.28%), respectively. CONCLUSION: Dentin is exposed during resin-bonded fixed partial denture preparation if current tooth preparation guidelines are followed, despite the commonly made recommendation that the preparation remain within enamel. The region of the grooves consistently exhibited exposed dentin; exposure at the cervical margin was variable.

Bicuspid↗

Treatment of a juvenile patient with a maxillary all-ceramic resin-bonded fixed partial denture: a case report.

Treatment of juvenile patients with a missing maxillary incisor is difficult, because an implant cannot be placed until growth is completed. The other minimally invasive alternatives are also problematic: Removable dentures are rarely accepted by juvenile patients, and the conventional resin-bonded fixed partial denture often provides a poor esthetic result because the metal retainer causes the abutment teeth to lose their natural translucency and to become grayish. Moreover, the alveolar ridge defect makes it easy to identify the prosthesis in the pontic area. The present case report describes the prosthetic treatment of a juvenile patient who had lost a maxillary incisor to trauma. To avoid the disadvantages of conventional therapies, subepithelial connective tissue was grafted to reshape the alveolar ridge. The space was closed with an all-ceramic resin-bonded fixed partial denture.

Adolescent↗

Fixed partial dentures: all-ceramics, fibre-reinforced composites and experimental systems.

The aim of this in vitro study was to compare the fracture strength of three-unit FPDs (fixed partial dentures) and three-unit inlay FPDs after a simulated 5-year oral wearing period. The restorations were made of a pressable all-ceramic (Empress 2) and two specially designed, experimentally fixed partial dentures combining ceramics with dental composite. Three-unit FPDs and inlay FPDs were manufactured and were adhesively luted onto human molars. After thermal cycling and mechanical loading in an artificial environment, the fracture strength was determined. Zircon-based milled ceramic (Lava) three-unit FPDs were used as a control. The zircon ceramic and the fibre-based ceramic three-unit FPDs showed median fracture values between 1000 and 1400 N. For composite veneered zircon FPDs a fracture strength of about 800 N and for all-ceramic Empress 2 of about 350 N could be determined. The results for the inlay FPDs were between 1300 N and 1400 N for FRC/ceramic, 1000 N for zircon/composite and 500 N for all-ceramic restorations. The all-ceramic showed higher fracture resistance applied as inlay FPDs. The described hybrid techniques combining ceramics and composites could represent an interesting procedure for further investigations and, eventually, clinical implication.

Aluminum Silicates↗

A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 years.

The present study was done to determine the long-term success and survival of fixed partial dentures (FPDs) and to evaluate the risks for failures due to specific biological and technical complications. A MEDLINE search (PubMed) from 1966 up to March 2004 was conducted, as well as hand searching of bibliographies from relevant articles. Nineteen studies from an initial yield of 3658 titles were finally selected and data were extracted independently by three reviewers. Prospective and retrospective cohort studies with a mean follow-up time of at least 5 years in which patients had been examined clinically at the follow-up visits were included in the meta-analysis. Publications only based on patients records, questionnaires or interviews were excluded. Survival of the FPDs was analyzed according to in situ and intact failure risks. Specific biological and technical complications such as caries, loss of vitality and periodontal disease recurrence as well as loss of retention, loss of vitality, tooth and material fractures were also analyzed. The 10-year probability of survival for fixed partial dentures was 89.1% (95% confidence interval (CI): 81-93.8%) while the probability of success was 71.1% (95% CI: 47.7-85.2%). The 10-year risk for caries and periodontitis leading to FPD loss was 2.6% and 0.7%, respectively. The 10-year risk for loss of retention was 6.4%, for abutment fracture 2.1% and for material fractures 3.2%.

Algorithms↗

Survival rates of resin-bonded, glass fiber-reinforced composite fixed partial dentures with a mean follow-up of 42 months: a pilot study.

STATEMENT OF PROBLEM: Although short-term clinical data exist for resin-bonded, glass fiber-reinforced composite fixed partial dentures (FPDs), long-term data are needed. PURPOSE: The survival rates of 29 resin-bonded, glass fiber-reinforced composite fixed partial dentures were evaluated in this clinical study for periods of up to 42 months. MATERIAL AND METHODS: FPDs were fabricated to replace 1 to 3 missing maxillary or mandibular teeth of 29 patients not able to be treated with conventional FPDs. Originally, there were 37 patients (the drop-out rate was 22%). The FPDs were retained with wings, inlays, complete coverage crowns, or combinations of these that were bonded to tooth structure. The FPD frameworks were made of continuous unidirectional E-glass fibers with a multiphase polymer matrix and light-polymerized particulate composite veneer. The patients were recalled for examinations, where a general dental examination was performed, 1 to 3 times per year for up to 63 months (minimum 24 months, mean 42 months). Partial or complete total debonding of the FPD or the framework fracture was considered a treatment failure. The data were analyzed with the Kaplan-Meier survival test (alpha=.05). RESULTS: Two resin frameworks fractured, and 3 frameworks were debonded. Kaplan-Meier survival probability at 63 months was 75%. Three of the failed FPDs were rebonded or repaired in situ, producing a functional survival rate of 93% after rebonding or repairing (mean survival time was 55 months). CONCLUSION: The results of this clinical study of 29 prostheses suggest that glass fiber-reinforced FPDs may be a possible alternative to cast metal resin-bonded FPDs. These restorations were successfully used as multiple-unit prostheses that employed a variety of abutment tooth preparation designs.

Composite Resins↗

[Analysis of stresses in modified resin-bonded cast fixed partial dentures].

In 1973, ROCHETTE introduced a periodontal splinting method that involved bonding of cast perforated retainers to the acid etched lingual surfaces of anterior teeth, using a resin. Nowadays, there have been a number of reports on the clinical performance of the adhesive bridges. The objective of this investigation was to photoelastically evaluate the forces exerted on the supporting structures of abutment teeth by modified resin-bonded cast fixed partial dentures. Four modified designs were tested and a traditional fixed bridge used as a control design. This study indicated that the resin bonded cast fixed partial denture with the lingual chamfer margin and mesial rest was the design to be chosen.

Dental Abutments↗

Marginal adaptation of inlay-retained adhesive fixed partial dentures after mechanical and thermal stress: an in vitro study.

STATEMENT OF PROBLEM: There are no studies that analyze the long-term durability of minimally invasive fixed partial dentures (FPDs) by comparing different methods of adhesive bonding. PURPOSE: This in vitro study examined the influence of cavity design and operative technique on the marginal adaptation of resin-bonded composite FPDs. MATERIAL AND METHODS: Slot-inlay tooth preparations with cavity margins located in enamel were prepared in 18 maxillary canines and 18 maxillary first molars designated as abutments. The specimens were divided equally into 3 experimental groups. In all groups, butt joint tooth preparations were created in canines and molars. In group 2, canines were prepared additionally with a 1.5-mm wide palatal bevel in enamel. After pretests with modification spaces of 11 and 17 mm (length), 2 missing premolars were replaced by the ceromer Targis and reinforced with the glass-fiber material Vectris. The prostheses were inserted with Tetric Ceram with use of an ultrasonic-supported, high-viscosity technique. Restorations were selectively bonded to cavity finish lines in groups 1 and 2 ("selective bonding"). In group 3, restorations were bonded totally to the whole cavity surface ("total bonding"). The restorations were stressed in a computer-controlled masticator. Marginal quality was examined with an SEM at x 200. RESULTS: The percent area of optimal margins after thermomechanical loading between composite and enamel in each group was as follows: group 1, 86.2% +/- 12.3% for canines and 95.5% +/- 3.5% for molars; group 2, 95.3% +/- 2.1% for canines and 96.2% +/- 2.7% for molars; and group 3, 95% +/- 0.9% for canines and 86.4% +/- 3.2% for molars. The marginal quality for molars inserted with total bonding was significantly lower (P< or =.05). CONCLUSION: Within the limitations of this study, the selective bonding technique for slot inlay-retained fixed partial dentures resulted in a negligible loss of marginal quality after extensive mechanical and thermal stress. The selective bonding technique is recommended for box-shaped cavity preparations.

Acid Etching, Dental↗

Use of abutment-teeth vs. dental implants to support all-ceramic fixed partial dentures: an in-vitro study on fracture strength.

The aim of the present in-vitro study was to compare the fracture strength of all-ceramic Fixed Partial Dentures supported by tooth-analogues and periodontal membrane with the same supported by dental implants. As ceramics are highly brittle, they cannot withstand deformations of more than 0.1% without fracturing. Hence, when planning an all-ceramic FPD, it is essential to evaluate abutment support, as the fracture strength of all-ceramic constructions depends on the stability of the support to reduce strain in the beam of the prosthesis. The support provided by implants differs, however, from the support provided by natural teeth as the implants are anchored directly in the bone with no intermediate tissue. One question that arises is whether strain and stress in the prosthesis are lower when the prosthesis is loaded on implants compared to natural teeth and hence if all-ceramic FPDs benefit from implant support. Twenty-four three-unit all-ceramic FPDs-12 supported by two dental implants and 12 by two tooth-analogues serving as end abutments-were made. All FPDs were subjected to preloading in a preloading procedure and subsequently subjected to load until fracture occurred. Load at fracture were registered and comparisons between the two groups were made. The loads at fracture were statistically significant higher in the group supported by implants compared to the group supported by tooth-analogues (p = 0.003). Within the limitations of this in-vitro study, the following conclusions can be drawn: All-ceramic fixed partial dentures can be used in combination with dental implants. The solid support gained from implants might thus be beneficial for the outcome of such treatment due to decreased strain and stress levels in the prosthesis when loaded on implants compared to when loaded on natural teeth. Clinical studies are, however, needed to confirm these findings as there are more factors that influence the final clinical outcome.

Dental Abutments↗