PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “LUBRICATION”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13Linked to original sources

Joint lubrication.

The fine-pored, easily compressed articular cartilage provides animal joints with self-pressurized hydrostatic (weeping) lubrication. The solid skeletons of the cartilages press against each other, but so lightly that their rubbing is lubricated successfully by synovial fluid--a boundary lubricant too weak to lubricate ordinary bearings.

Animals↗

Pathological human synovial fluids. Viscosity and boundary lubricating properties.

On human synovial fluids obtained during operations from the knee joints of 80 patients with different joing disease, relative viscosity was measured at 3 different shear rates and the boundary lubrication was tested by the coefficient of friction in an artificial rubber/glass system. The results were evaluated in relation to the operative findings. The viscosity showed statistically significant differences between the synovial fluids from the knee joints with rheumatoid arthritis, osteoarthritis, and torn menisci, being lowest in rheumatoid synovial fluid and highest in synovial fluids from knee joints with torn menisci. Correlations were found in the variations in the viscosity and the degree of synovitis. The boundary lubrication also showed different values inrelation to the different diseases. Synovial fluid from knee joints with torn menisci seemed to act as the best lubricant and significantly better than rheumatoid synovial fluid. Variations in the boundary lubrications reflect successive degrees of cartilage degeneration.

Arthritis, Rheumatoid↗

Water and bovine serum lubrication compared in simulator PTFE/CoCr wear model.

Controversy surrounds wear data from laboratory hip simulator studies, whether derived from water-based or serum-based studies or whether a major design parameter such as the size of the femoral head has an effect on the volume of wear particulate released. To investigate these relationships, we studied cup wear in water- and serum-based lubricants using as our standard the polytetrafluoroethylene (PTFE) data derived by Charnley. To model Charnley's clinical experience, PTFE acetabular cups were used in sets of three each of four sizes of CoCr femoral heads: 22.25-, 28-, 32-, and 42-mm diameters. Six criteria were used to evaluate the performance of the lubricants against clinical accuracy and scientific methods. The PTFE wear data from the serum-based tests was consistently linear with the duration of the test, exhibited a precision within +/-3% about the average for each set of three cups, and copious amounts of wear debris were clearly seen circulating and settling to the bottom of the wear chambers. The wear data clearly demonstrated Charnley's thesis that volume of wear increases with regard to the size of the femoral head in a linear manner. This increase was considered satisfactory at 9%/ mm. However, in terms of clinical accuracy, the simulator wear rates averaged 3 to 4 times greater than the comparable clinical data for wear magnitude. Thus, the serum-based tests satisfied three of the six criteria used. The PTFE wear data from the water-based tests was generally nonlinear, continually increasing with test duration. These wear trends were examined in three discrete phases to estimate the changing wear rates. By the end of the tests, the wear rates had increased from 1.3 to 3.9 times, with the 42-mm heads showing the greatest change. The resulting precision was never better than +/-26% and deteriorated to +/-70%. In terms of clinical accuracy, the water-based wear rates varied from 2 to 7 times less than the Charnley PTFE wear magnitudes, averaging 4 times less. The water-based data did not satisfactorily model the relationship between increased wear with increased head size. Minimal PTFE wear debris was observed, and what did emerge after thousands of wear cycles appeared as streamers up to 30 mm long and up to 5 mm wide. When these detached, they floated up to the surface where they could be separated into smaller particulates. A similar phenomenon was noted for polyethylene wear tests conducted with water lubrication. Thus the water-based tests satisfied none of the six validation criteria evaluated. These data raise serious doubts as to the validity of testing implant and material combinations in water as a predictor of clinical performance. Bovine serum was not totally satisfactory, but the wear data did model some of the important clinical characteristics of hip joint behavior.

Animals↗

Thin film rheology and lubricity of hyaluronic acid solutions at a normal physiological concentration.

Using a surface forces apparatus to measure forces, and optical (multiple beam) interferometry to measure surface shapes and separations (to +/-1 A), the normal, viscous, and shear (lubrication) forces between smooth mica surfaces in aqueous hyaluronic acid (HA) solutions were measured. The experimental conditions of loading pressures, pH, and HA concentration were set to closely correspond to physiological human knee-joint conditions. From the force and optical (refractive index) measurements, it was concluded that, like other negatively charged polyelectrolytes, HA does not naturally adsorb on the mica surface which is hydrophilic and weakly negatively charged at physiological conditions: the polymer solution exhibits the bulk viscosity (22.5 +/- 1.5 cP) for films thicker than about 0.4 miccrom of the polymer, whereas for thinner films, the viscosity decreases monotonically toward the value of the pure electrolyte solution (1 cP) as HA is extruded from between the surfaces. This is indicative of a repulsive "depletion" interaction of HA with each mica surface and to a weakly attractive polymer-mediated force between the two surfaces. Thus, free HA in synovial fluid is not expected to act as a good "boundary lubricant." Relaxation measurements on approaching and receding surfaces in HA solutions were also performed, and it is shown that the presence of HA in the bulk solution can improve "hydrodynamic" modes of lubrication, for example, by assuaging the compression stroke. The study includes information that is beneficial to researchers working with biomaterials viscosupplementation devices.

Adsorption↗

Comparative evaluation of tablet lubricants: effect of application method on tablet hardness and ejectability after compression.

The effect of four lubricants (stearic acid, magnesium stearate, calcium stearate, and talc) on the ejectability and hardness of statically compressed tablets of a lactose granulation was examined. Two methods of application of these lubricants, incorporation into the granulation and mixing with the granulation, were compared. In both methods, the energy consumption curves during ejection and the hardness curves with lubricant concentration were similar and showed complicated behavior at a lower concentration. The mixing method gave better results for ejectability and hardness than the incorporation method.

Drug Compounding↗

Chemical, physical, and lubricant properties of magnesium stearate.

Three batches of commercial magnesium stearate were characterized in terms of their fatty acid composition, moisture content, and specific surface area. None of these variables appeared to have any effect on the lubricant activity of the samples. The lubricant properties of the compound were further examined using three hydrates of laboratory-prepared (pure) magnesium stearate. Based on the results obtained from the pure samples, it appears that differences in the lubricant properties of magnesium stearate are correlated with differences in moisture content and crystalline structure.

Chemical Phenomena↗

Phospholipids identified on the pericardium and their ability to impart boundary lubrication.

Phospholipids have been identified by thin-layer chromatography in appreciable quantities in pericardial fluid taken from 12 dogs and found to include sphingomyelin and phosphatidylcholines, -ethanolamines, -inositols and -serines--the cholines predominating. The extracts, the synthetic surfactants and a mixture of synthetics simulating the extracts were all found to be good lubricants when tested by a standard method. The phosphatidylcholines were capable of reducing friction between two otherwise hydrophilic surfaces by as much as 100- to 200-fold when deposited as an oriented monolayer. A goniometer was used to measure an average contact angle of 33 degrees for a drop of saline placed upon the internal wall of the pericardium, indicating an appreciably hydrophobic surface anticipated if surfactant were directly adsorbed. The results are consistent with the classical theory of "boundary" lubrication (17) as modified (21) to reflect the almost ideal molecular structure of the identified surfactants for adsorption, film cohesion and interaction of fatty-acid chains during sliding. This model is proposed as an alternative to hydrodynamic lubrication in the pericardium and one compatible with several practical aspects such as pericardial rub and the maintenance of normal heart action after pericardectomy.

Animals↗

Lubrication of human and bovine enamel compared in an artificial mouth.

Bovine enamel has been a good model for human enamel across a broad range of studies. The present work sought to consider if bovine enamel would be a suitable substitute for human enamel in experiments on simulated oral lubrication. Enamel samples of the same size were prepared from bovine and human teeth for use as maxillary and mandibular elements in a miniature artificial mouth. Sliding speeds from 1.99 to 7.84 mm/s and occlusal forces of 3.8-19.5 N were used. Water and four solutions consisting of a mucin-rich fraction, a statherin-rich fraction, 3[(3-cholamidopropyl)-dimethylammonio]-1-propanesulphonate and sodium dodecyl sulphate were evaluated. The high correlations between widely different lubricants on the two enamel substrates gives confidence in the use of bovine enamel as a model for human enamel in salivary lubrication studies. Knoop hardness indentations on enamel samples were combined with friction data and calculations of the true contact area to give a method for the indirect determination of surface shear. The calculated surface shear value was compared with published values obtained by punch shear testing.

Animals↗

Mineral oil lubricants cause rapid deterioration of latex condoms.

As little as sixty seconds' exposure of commercial latex condoms to mineral oil, a common component of hand lotions and other lubricants used during sexual intercourse, caused approximately 90% decrease in the strength of the condoms, as measured by their burst volumes in the standard ISO (International Standards Organization) Air Burst Test. Burst pressures were also reduced, although less dramatically. Lubricants such as Vaseline Intensive Care and Johnson's Baby Oil, each containing mineral oil, also affected condom integrity. Five min. exposure of condoms to glycerol, a frequent component of hand lotions and 'personal lubricants', did not significantly affect burst volume or pressure. Aqueous nonoxynol-9 spermicide did not affect either burst index. The implications of these results for contraception and protection from sexually transmitted diseases, including AIDS, are discussed.

Contraceptive Devices, Male↗

New lubricants from vegetable oil: cyclic acetals of methyl 9,10-dihydroxystearate.

Potential new lubricants and fuel lubricity enhancers have been prepared from methyl 9,10-dihydroxystearate and long chain aldehydes to form the corresponding cyclic acetals. These materials are oils down to low temperatures, as compared to symmetric ketals derived from the same diol, which are waxes at room temperature. The acetals form in an equilibrium reaction (Keq approximately 60) which suggests they will be stable as fuel additives. The viscosities of the new oils are close to those predicted for normal paraffins with the same number of non-hydrogen atoms, but the acetal structure has subtle effects on viscosity as compared to branched alkanes. Acetals with long alkyl branches maintain higher viscosity on a molecular weight basis compared to branched alkanes. The qualitative relationship between branch length and viscosity is discussed. These acetals are potential candidates for novel biobased lubricants.

Acetals↗

Migration of lubricants from food packagings. Screening for lipid classes and quantitative estimation using normal-phase liquid chromatographic separation with evaporative light scattering detection.

A normal-phase high-performance liquid chromatography (NP-HPLC) method is introduced for the identification and quantitative estimation of 12 lipid classes (paraffin, wax esters, cholesterol esters, fatty acid methyl esters, triacyl glycerols, fatty alcohols, free fatty acids, cholesterol, 1,3-diacyl glycerols, 1,2-diacyl glycerols, monoacyl glycerols and fatty acid amide) used as lubricantsin food packaging materials. The HPLC separation is carried out on a LiChrospher Diol (100 A, 5 microm, 125 mm x 3 mm) column with gradient elution (isooctane/0.1% acetic acid in tert-butyl methyl ether) and evaporative light scattering detection (ELSD). The method has been calibrated with representatives of each class in working ranges of about 5-150 mg/l, depending on the lipid class. Intra-day variance for all representatives range from 1.9 to 5.1%, inter-day variances from 7.0 to 26.5% and the limits of detection from 0.79 to 3.65 mg/l (except for two classes). A simple sample preparation could be established for the determination of migrating lubricants obtained from packaging materials containing external or internal lubricants. Since the detector response depends on the chain length and the degree of saturation, the quantification of a lipid class with unknown composition is only semi-quantitative. The amount of migrating lubricants from an epoxy-based can coating could be estimated with 0.3 mg/dm2 and from a light weight container with 5.5 mg/dm2.

Chromatography, High Pressure Liquid↗

Lubricants containing N-9 may enhance rectal transmission of HIV and other STIs.

It has been shown that men who have sex with men actively seek lubricants that contain nonoxynol-9 (N-9) because they believe that N-9 may help to prevent infection by HIV. However, indirect evidence suggests that N-9 may actually enhance infection. Microscopic examination of rectal lavage and biopsy specimens collected at different time points following rectal application of a lubricant containing 2% N-9 showed rapid exfoliation of the rectal epithelium. Because the rectal epithelium protects target cells in the submucosa from HIV, we conclude that lubricants containing N-9 should be avoided during rectal sex.

Biopsy↗

Transient elastohydrodynamic lubrication analysis of metal-on-metal hip implant under simulated walking conditions.

The transient elastohydrodynamic lubrication (EHL) analysis was performed in this study for a typical metal-on-metal bearing employing a polyethylene backing underneath a metallic cup inlay under dynamic operating conditions of load and speed representative of normal walking. A ball-in-socket configuration was adopted to represent the articulation between the femoral head and the acetabular cup. The governing Reynolds and elasticity equations were solved simultaneously by using both finite difference and finite element methods. The predicted transient film thickness from the present study was compared with the estimation based on the quasi-static analysis. It was found that the polyethylene backing employed in the typical metal-on-metal hip bearing, combined with dynamic squeeze-film action, significantly improved the transient lubricant film thickness under cyclic walking and consequently a fluid film lubrication regime was possible for smooth bearing surfaces with an average roughness less than 0.005 microm.

Biocompatible Materials↗

Confirmation of heavy metal ions in used lubricating oil from a passenger car using chelating self-assembled monolayer.

In order to prevent engine failure, the oil must be changed before it loses its protective properties. It is necessary to monitor the actual physical and chemical condition of the oil to reliably determine the optimum oil-change interval. Our study focuses on the condition of the lubricating oil in an operated car engine. Shear stress curves and viscosity curves as a function of the shear rate for fresh and used lubricating oil were examined. Metal nitrate was detected in the lubricating oil from the operated car engine through the use of a chelating self-assembled monolayer.

Automobiles↗

Used lubricating oil recycling using hydrocarbon solvents.

A solvent extraction process using new hydrocarbon solvents was employed to treat used lubricant oil. The solvents used were liquefied petroleum gas (LPG) condensate and stabilized condensate. A demulsifier was used to enhance the treatment process. The extraction process using stabilized condensate demonstrated characteristics that make it competitive with existing used oil treatment technologies. The process is able to reduce the asphaltene content of the treated lubricating oil to 0.106% (w/w), the ash content to 0.108%, and the carbon residue to 0.315% with very low levels of contaminant metals. The overall yield of oil is 79%. The treated used oil can be recycled as base lubricating oil. The major disadvantage of this work is the high temperature of solvent recovery. Experimental work and results are presented in detail.

Carbon↗

Biphasic surface amorphous layer lubrication of articular cartilage.

The biphasic nature of articular cartilage has been acknowledged for some time and is known to play an important role in many of the biomechanical functions performed by this unique tissue. From the lubrication point of view however, a simple biphasic model is unable to account for the extremely low friction coefficients that have been recorded experimentally, particularly during start-up. In addition, research over the last decade has indicated the presence of a surface amorphous layer on top of articular cartilage. Here, we present results from a finite element model of articular cartilage that includes a thin, soft, biphasic surface amorphous layer (BSAL). The results of this study show that a thin BSAL, with lower elastic modulus, dramatically altered the load sharing between the solid and liquid phases of articular cartilage, particularly in the near-surface regions of the underlying bulk cartilage and within the surface amorphous layer itself where the fluid load support exceeded 85%. By transferring the load from the solid phase to the fluid phase, the biphasic surface layer improves lubrication and reduces friction, whilst also protecting the underlying cartilage surface by 'shielding' the solid phase from elevated stresses. The increase in lubrication effectiveness is shown to be greatest during short duration loading scenarios, such as shock loads.

Biomechanical Phenomena↗

Reduced need for corneal epithelial debridement during vitreo-retinal surgery using two different viscous surface lubricants.

PURPOSE: Corneal clarity is frequently reduced during vitrectomy and scleral buckling surgery secondary to epithelial edema, requiring epithelial debridement to improve visibility. The presence of toxic preservatives in the corneal lubricant solutions is hypothesized to be a contributing factor to epithelial edema during vitreo-retinal surgery. DESIGN: Interventional study. METHODS: We compared prospectively the corneal clarity and epithelial debridement frequency in 71 patients within a single institution in whom either Goniosol (2.5% methylcellulose, boric acid, edetate disodium, sodium borate, potassium chloride, water, and 0.01% benzalkonium chloride) or GenTeal gel (0.3% hydoxypropyl-methylcellulose, carbopol 980, phosphonic acid, sorbitol, water, and 0.028% sodium perborate) was used as a corneal lubricant during the course of vitrectomy surgery using sutured contact lenses. Corneal clarity was subjectively graded in a scale of I to IV during surgery. Statistical analysis was made between these two groups for parametric and categorical data. RESULTS: All eyes started with a corneal clarity grade of I (best possible). Corneal clarity decreased significantly faster in eyes where Goniosol was used to a median grade of III at 1 hour of surgical time. In eyes where GenTeal gel was used, corneal clarity decreased much slower, to a median grade of I at 1 hour of surgical time. The difference in frequency of epithelial debridement was also statistically significant: 54% and 14% for Goniosol and GenTeal eyes, respectively. Other factors that may cause corneal epithelial edema and affect corneal clarity were not statistically different between the Goniosol and the GenTeal groups, including median operative time, estimated intraocular pressure, pre- and intraoperative topical solutions and medications, and number of prior ocular procedures. CONCLUSIONS: The use of GenTeal gel as a corneal lubricant maintains corneal clarity longer than Goniosol during the course of vitrectomy surgery using a contact lens viewing system, limiting the need for epithelial debridement.

Adolescent↗

The effect of vaginal lubricants on sperm motility in vitro.

Apart from the documentation of the spermicidal effects of KY Jelly and Surgilube, little information about the effect of vaginal lubricants on sperm motility has been available. Fifteen substances utilizable as vaginal lubricants were therefore tested for their effect on sperm motility in vitro. Petroleum jelly and glycerin had minimal detrimental effects on motility and apparently are the lubricants of choice when an infertility problem exists.

Contraceptive Agents, Female↗