PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Microfluidics”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13Linked to original sources

On-chip titration of an anticoagulant argatroban and determination of the clotting time within whole blood or plasma using a plug-based microfluidic system.

This paper describes extending plug-based microfluidics to handling complex biological fluids such as blood, solving the problem of injecting additional reagents into plugs, and applying this system to measuring of clotting time in small volumes of whole blood and plasma. Plugs are droplets transported through microchannels by fluorocarbon fluids. A plug-based microfluidic system was developed to titrate an anticoagulant (argatroban) into blood samples and to measure the clotting time using the activated partial thromboplastin time (APTT) test. To carry out these experiments, the following techniques were developed for a plug-based system: (i) using Teflon AF coating on the microchannel wall to enable formation of plugs containing blood and transport of the solid fibrin clots within plugs, (ii) using a hydrophilic glass capillary to enable reliable merging of a reagent from an aqueous stream into plugs, (iii) using bright-field microscopy to detect the formation of a fibrin clot within plugs and using fluorescent microscopy to detect the production of thrombin using a fluorogenic substrate, and (iv) titration of argatroban (0-1.5 microg/mL) into plugs and measurement of the resulting APTTs at room temperature (23 degrees C) and physiological temperature (37 degrees C). APTT measurements were conducted with normal pooled plasma (platelet-poor plasma) and with donor's blood samples (both whole blood and platelet-rich plasma). APTT values and APTT ratios measured by the plug-based microfluidic device were compared to the results from a clinical laboratory at 37 degrees C. APTT obtained from the on-chip assay were about double those from the clinical laboratory but the APTT ratios from these two methods agreed well with each other.

Anticoagulants↗

On-demand patterning of protein matrixes inside a microfluidic device.

On-demand immobilization of proteins at specific locations in a microfluidic device would advance many types of bioassays. We describe a strategy to create a patterned surface within a microfluidic channel by electrochemical means, which enables site-specific immobilization of protein matrixes and cells under physiological conditions, even after the device is fully assembled. By locally generating hypobromous acid at a microelectrode in the microchannel, the heparin-coated channel surface rapidly switches from antibiofouling to protein-adhering. Since this transformation allows compartmentalizing of multiple types of antibodies into distinct regions throughout the single microchannel, simultaneous assay of two kinds of complementary proteins was possible. This patterning procedure can be applied to conventional microfluidic devices since it requires only some electrodes and a voltage source (1.7 V, DC).

Animals↗

High-throughput and high-resolution flow cytometry in molded microfluidic devices.

We describe the design, fabrication, and operation of two types of flow cytometers based on microfluidic devices made of a single cast of poly(dimethylsiloxane). The stream of particles or cells injected into the devices is hydrodynamically focused in both transverse and lateral directions, has a uniform velocity, and has adjustable diameter and shape. The cytometry system built around the first microfluidic device has fluorescence detection accuracy comparable with that of a commercial flow cytometer and can analyze as many as 17 000 particles/s. This high-throughput microfluidic device could be used in inexpensive stand-alone cytometers or as a part of integrated microanalysis systems. In the second device, a stream of particles is focused to a flow layer of a submicrometer thickness that allows imaging the particles with a high numerical aperture microscope objective. To take long-exposure, low-light fluorescence images of live cells, the device is placed on a moving stage, which accurately balances the translational motion of particles in the flow. The achieved resolution is comparable to that of still micrographs. This high-resolution device could be used for analysis of morphology and fluorescence distribution in cells in continuous flow.

Flow Cytometry↗

On-chip enzyme immunoassay of a cardiac marker using a microfluidic device combined with a portable surface plasmon resonance system.

This paper reports a miniaturized immunosensor designed to determine a trace level cardiac marker, B-type natriuretic peptide (BNP), using a microfluidic device combined with a portable surface plasmon resonance (SPR) sensor system. Sample BNP solution was introduced into the microchannel after an immunoreaction with acetylcholine esterase-labeled antibody (conjugate), and only unbound conjugate was trapped on the BNP-immobilized surface in the flow channel. Then, the thiol compound generated by the enzymatic reaction with the trapped conjugate was accumulated on a gold thin film located downstream in the microchannel to monitor the real-time SPR angle shift. We achieved a detectable concentration range of 5 pg/mL-100 ng/mL by monitoring the SPR angle shift, which covers the required detection range for the BNP concentrations found in blood. This success resulted from the use of a T-shaped microfluidic device structure, which prevents the sample solution from flowing over the gold film used for SPR detection. We were able to measure trace levels of BNP peptide (15 fg) within 30 min since the procedure with our immunosensor is simpler than a multistep immunoassay through the simultaneous use of a labeled enzymatic reaction and the real-time monitoring of enzymatic product accumulation in the microfluidic device. We employed the procedure to detect serum BNP by using spiked samples in human serum and achieved satisfactory recovery for heat-treated samples to denature the esterase in the serum before the immunoreaction.

Biomarkers↗

Microfluidic serial dilution circuit.

In vitro evolution of RNA molecules requires a method for executing many consecutive serial dilutions. To solve this problem, a microfluidic circuit has been fabricated in a three-layer glass-PDMS-glass device. The 400-nL serial dilution circuit contains five integrated membrane valves: three two-way valves arranged in a loop to drive cyclic mixing of the diluent and carryover, and two bus valves to control fluidic access to the circuit through input and output channels. By varying the valve placement in the circuit, carryover fractions from 0.04 to 0.2 were obtained. Each dilution process, which is composed of a diluent flush cycle followed by a mixing cycle, is carried out with no pipeting, and a sample volume of 400 nL is sufficient for conducting an arbitrary number of serial dilutions. Mixing is precisely controlled by changing the cyclic pumping rate, with a minimum mixing time of 22 s. This microfluidic circuit is generally applicable for integrating automated serial dilution and sample preparation in almost any microfluidic architecture.

Dimethylpolysiloxanes↗

Measurements of kinetic parameters in a microfluidic reactor.

Continuous flow microfluidic reactors that use immobilized components of enzymatic reactions present special challenges in interpretation of kinetic data. This study evaluates the difference between mass-transfer effects and reduced efficiencies of an enzyme reaction. The kinetic properties of immobilized alkaline phosphatase (AP) were measured by the dephosphorylation of 6,8-difluoro-4-methylumbelliferyl/phosphate to a fluorescent 6,8-difluoro-4-methylumbelliferone. A glass microfluidic chip with an in-channel weir was created for the capture of solid silica microbeads functionalized with enzyme. The input substrate concentrations and flow rates across the bed were varied to probe the flow-dependent transport and kinetic properties of the reaction in the microreactor bed. Unlike previous reactors, substrate was titrated directly over the fixed enzyme bed by controlling the air pressure over the chip reservoirs. The reactor explored substrate conversions from near zero to 100%. The average bed porosity, residence time, and bed resistance were measured with dye pulses. A simple criterion was derived to evaluate the importance of flow-dependent mass-transfer resistances when using microreactors for calculating kinetic rate constants. In the absence of mass-transfer resistances, the Michaelis-Menten kinetic parameters are shown to be flow independent and are appropriately predicted using low substrate conversion data. A comparison of the kinetic parameters with those obtained using solution-phase enzymatic reactions shows a significant decrease in enzyme activity in the immobilized conformation. The immobilized Km of AP is approximately 6 times greater while the kcat is reduced by approximately 28 times. Contradictions found in literature on the evaluation of Michaelis-Menten kinetic parameters for immobilized enzymes in microfluidic reactors are addressed. When product molecules occupy a significant number of enzymatic sites or modify the enzyme activity, the assumed Michaelis-Menten mechanism can no longer be valid. Under these conditions, the calculations of "apparent" kinetic rate constants, based on Michaelis-Menten kinetics, can superficially show a dependence on flow rate conditions even in the absence of mass-transfer resistances. High substrate conversions are shown to depend on flow rate. A kinetic model based on known mechanisms of the alkaline phosphatase enzyme reaction is tested to predict the measurements for high substrate conversion. The study provides a basis for appropriate use of mass-transfer and reaction arguments in successful application of enzymatic microreactors.

Adsorption↗

A microfluidic device for kinetic optimization of protein crystallization and in situ structure determination.

The unprecedented economies of scale and unique mass transport properties of microfluidic devices made them viable nano-volume protein crystallization screening platforms. However, realizing the full potential of microfluidic crystallization requires complementary technologies for crystal optimization and harvesting. In this paper, we report a microfluidic device which provides a link between chip-based nanoliter volume crystallization screening and structure analysis through "kinetic optimization" of crystallization reactions and in situ structure determination. Kinetic optimization through systematic variation of reactor geometry and actuation of micromechanical valves is used to screen a large ensemble of kinetic trajectories that are not practical with conventional techniques. Using this device, we demonstrate control over crystal quality, reliable scale-up from nanoliter volume reactions, facile harvesting and cryoprotectant screening, and protein structure determination at atomic resolution from data collected in-chip.

Aldose-Ketose Isomerases↗

Microgram-scale testing of reaction conditions in solution using nanoliter plugs in microfluidics with detection by MALDI-MS.

This paper describes a microfluidic system to screen and optimize organic reaction conditions on a submicrogram scale. The system uses discrete droplets (plugs) as microreactors separated and transported by a continuous phase of a fluorinated carrier fluid. Previously, we demonstrated the use of a microfabricated PDMS plug-based microfluidic system to perform assays and crystallization experiments in aqueous solutions with optical detection. Here, we developed an approach that does not require microfabrication of microfluidic devices, is applicable to synthetic reactions in organic solvents, and uses detection by MALDI-MS. As a demonstration, conditions for selective deacetylation of ouabain hexaacetate were tested, and the optimum conditions for mono-, bis-, or trisdeacetylation have been identified. These conditions were validated by scale-up reactions and isolating these potentially neurotoxic products. Mono- and bisdeacetylated products are unstable intermediates in the deacetylation and were isolated for the first time. This system enables no-loss handling of submicroliter volumes containing a few micrograms of a compound of interest. It could become valuable for investigating or optimizing reactions of precious substrates (e.g., products of long synthetic sequences and natural products that can be isolated only in small quantities).

Acetylation↗

Nonlithographic fabrication of microfluidic devices.

A facile nonlithographic method for expedient fabrication of microfluidic devices of poly(dimethylsiloxane) is described. Positive-relief masters for the molds are directly printed on smooth substrates. For the formation of connecting channels and chambers inside the polymer components of the microfluidic devices, cavity-forming elements are adhered to the surfaces of the masters. Using this nonlithographic approach, we fabricated microfluidic devices for detection of bacterial spores on the basis of enhancement of the emission of terbium (III) ions.

Microfluidic Analytical Techniques↗

Microfluidic production of biopolymer microcapsules with controlled morphology.

We report a microfluidic approach to generating capsules of biopolymer hydrogels. Droplets of an aqueous solution of a biopolymer were emulsified in an organic phase comprising a cross-linking agent. Polymer gelation was achieved in situ (on a microfluidic chip) by diffusion-controlled ionic cross-linking of the biopolymer, following the transfer of the cross-linking agent from the continuous phase to the droplets. Gelation was quenched by collecting particles in a large pool of cross-linking agent-free liquid. The structure of microgels (from capsules to gradient microgels to particles with a uniform structure) was controlled by varying the time of residence of droplets on the microfluidic chip and the concentration of the cross-linking agent in the continuous phase. We demonstrated the encapsulation of a controlled number of polystyrene beads in the microgel capsules. The described approach was applied to the preparation of capsules of several polysaccharides such as alginate, kappa-carrageenan, and carboxymethylcellulose.

Capsules↗

Surface modification for enhancing antibody binding on polymer-based microfluidic device for enzyme-linked immunosorbent assay.

A novel surface treatment method using poly(ethyleneimine) (PEI), an amine-bearing polymer, was developed to enhance antibody binding on the poly(methyl methacrylate) (PMMA) microfluidic immunoassay device. By treating the PMMA surface of the microchannel on the microfluidic device with PEI, 10 times more active antibodies can be bound to the microchannel surface as compared to those without treatment or treated with the small amine-bearing molecule, hexamethylenediamine (HMD). Consequently, PEI surface modification greatly improved the immunoassay performance of the microfluidic device, making it more sensitive and reliable in the detection of IgG. The improvement can be attributed to the spacer effect as well as the functional amine groups provided by the polymeric PEI molecules. Due to the smaller dimensions (140x125 microm) of the microchannel, the time required for antibody diffusion and adsorption onto the microchannel surface was reduced to only several minutes, which was 10 times faster than the similar process carried out in 96-well plates. The microchip also had a wider detection dynamic range, from 5 to 1000 ng/mL, as compared to that of the microtiter plate (from 2 to 100 ng/mL). With the PEI surface modification, PMMA-based microchips can be effectively used for enzyme linked immunosorbent assays (ELISA) with a similar detection limit, but much less reagent consumption and shorter assay time as compared to the conventional 96-well plate.

Animals↗

Optically fabricated three dimensional nanofluidic mixers for microfluidic devices.

This paper describes a simple technique for fabricating complex, but well defined, three-dimensional (3D) networks of nanoscale flow paths in the channels of microfluidic systems. Near field scanning optical measurements reveal the optics associated with the fabrication process and the key features that enable its application to the area of microfluidics. Confocal studies of microfluidic devices that incorporate 3D nanostructures formed using this approach show that they function as efficient passive mixing elements, particularly at low Reynolds numbers. This application and others such as separation and extraction inmicrofluidic total analysis systems or lab on a chip devices represent promising areas for 3D nanostructures of this general type.

Equipment Design↗

Chemical and physical processes for integrated temperature control in microfluidic devices.

Microfluidic devices are a promising new tool for studying and optimizing (bio)chemical reactions and analyses. Many (bio)chemical reactions require accurate temperature control, such as for example thermocycling for PCR. Here, a new integrated temperature control system for microfluidic devices is presented, using chemical and physical processes to locally regulate temperature. In demonstration experiments, the evaporation of acetone was used as an endothermic process to cool a microchannel. Additionally, heating of a microchannel was achieved by dissolution of concentrated sulfuric acid in water as an exothermic process. Localization of the contact area of two flows in a microfluidic channel allows control of the position and the magnitude of the thermal effect.

Equipment Design↗

A plug and play microfluidic device.

Chip-to-world interface is a major issue in the field of microfluidics and its applications. We developed a plug and play microfluidic device composed of a fluid driving unit and a polymer chip containing microfluidic channels and reservoirs. The one and only connection of the device to the external world is a set of electric control lines for the driving unit. Just putting the reagents and samples onto the reservoirs, the chip can be operated for chemical or biochemical reaction and analysis. We demonstrate here that silicon-based micropumps embedded in the present device allow us to achieve flexible fluidic manipulations with minimum time delay and dead volume.

Animals↗

Fabrication of thermoset polyester microfluidic devices and embossing masters using rapid prototyped polydimethylsiloxane molds.

Plastics are increasingly being used for the fabrication of Lab-on-a-Chip devices due to the variety of beneficial material properties, affordable cost, and straightforward fabrication methods available from a range of different types of plastics. Rapid prototyping of polydimethylsiloxane (PDMS) devices has become a well-known process for the quick and easy fabrication of microfluidic devices in the research laboratory; however, PDMS is not always an appropriate material for every application. This paper describes the fabrication of thermoset polyester microfluidic devices and masters for hot embossing using replica molding techniques. Rapid prototyped PDMS molds are convienently used for the production of non-PDMS polymeric devices. The recessed features in the cast polyester can be bonded to a second polyester piece to form an enclosed microchannel. Thermoset polyester can withstand moderate amounts of pressure and elevated temperature; therefore, the cast polyester piece also can be used as a master for embossing polymethylmethacrylate (PMMA) microfluidic systems. Examples of enclosed polyester and PMMA microchannels are presented, and we discuss the electroosmotic properties of both types of channels, which are important for analytical applications such as capillary electrophoresis.

Chemical Phenomena↗

Joule heating and heat transfer in poly(dimethylsiloxane) microfluidic systems.

Joule heating is a significant problem in electrokinetically driven microfluidic chips, particularly polymeric systems where low thermal conductivities amplify the difficulty in rejecting this internally generated heat. In this work, a combined experimental (using a microscale thermometry technique) and numerical (using a 3D "whole-chip" finite element model) approach is used to examine Joule heating and heat transfer at a microchannel intersection in poly(dimethylsiloxane)(PDMS), and hybrid PDMS/Glass microfluidic systems. In general the numerical predictions and the experimental results agree quite well (typically within +/- 3 degree C), both showing dramatic temperature gradients at the intersection. At high potential field strengths a nearly five fold increase in the maximum buffer temperature was observed in the PDMS/PDMS chips over the PDMS/Glass systems. The detailed numerical analysis revealed that the vast majority of steady state heat rejection is through lower substrate of the chip, which was significantly impeded in the former case by the lower thermal conductivity PDMS substrate. The observed higher buffer temperature also lead to a number of significant secondary effects including a near doubling of the volume flow rate. Simple guidelines are proposed for improving polymeric chip design and thereby extend the capabilities of these microfluidic systems.

Computer Simulation↗

Transport, retention and fluorescent measurement of single biological cells studied in microfluidic chips.

Cellular manipulation and fluorescent measurement were performed on two types of biological cells. First, transport and retention of yeast cells were demonstrated on a glass microfluidic chip, which consists of special U-shaped microstructures. These microstructures have the openings parallel to the liquid flow and weirs perpendicular to the flow. These allow the retention of yeast cells in the U-shaped pocket and drainage of liquid over the weirs. Thereafter, the same chip was used to carry out real-time fluorescent measurement for the cellular changes in single Jurkat T cells. In this case, the Jurkat cells were localized inside the straight portion of a microchannel. Fluorescent imaging on the same, single suspension cell was carried out to study two cellular processes occurring in viable cells, (1) the intracellular conversion of fluorescein diacetate (FDA) to fluorescein; (2) the degradation of an inhibitory protein, IkappaB, as involved in the NF-kappaB signalling pathway. In the former, the increase in fluorescent intensity of single Jurkat T cells (due to fluorescein formation) was measured; whereas in the latter, the decrease in the fluorescent intensity of a single transfected Jurkat cell (due to the degradation of the IkappaB-EGFP fusion protein) was monitored. In addition, we employed a Jurkat cell expressed with IkappaB-EGFP to probe any possible action of an herbal compound, isoliquiritigenin (IQ), on the degradation of IkappaB-EGFP. These examples have demonstrated that Jurkat cells remain viable within microfluidic channels for cellular studies and that the microfluidic chip can facilitate monitoring of cellular changes of biological cells at the single cell level and in the same cell.

Biological Transport↗

A novel high aspect ratio microfluidic design to provide a stable and uniform microenvironment for cell growth in a high throughput mammalian cell culture array.

We present a high aspect ratio microfluidic device for culturing cells inside an array of microchambers with continuous perfusion of medium. The device was designed to provide a potential tool for cost-effective and automated cell culture. The single unit of the array consists of a circular microfluidic chamber 40 microm in height surrounded by multiple narrow perfusion channels 2 microm in height. The high aspect ratio (approximately 20) between the microchamber and the perfusion channels offers advantages such as localization of the cells inside the microchamber as well as creating a uniform microenvironment for cell growth. Finite element methods were used to simulate flow profile and mass transfer of the device. Human carcinoma (HeLa) cells were cultured inside the device with continuous perfusion of medium at 37 degrees C and was grown to confluency. The microfluidic cell culture array could potentially offer an affordable platform for a wide range of applications in high throughput cell-based screening, bioinformatics, synthetic biology, quantitative cell biology, and systems biology.

Cell Culture Techniques↗