Radionuclide angiography of vascular lesions of the spinal cord. Its efficacy in selecting patients for spinal angiography.

Selective angiography of the spinal cord is essential for both definitive diagnosis and preoperative evaluation of vascular lesions of the spinal cord. However, the complexity of angiography precludes its use in evaluating every spinal cord lesion. Radionuclide angiography successfully demonstrated vascular lesions of the spinal cord in our two cases, one a hemangioblastoma and the other an arteriovenous malformation. Myelography had not been conclusive in either case. The value of radionuclide angiography as a screening test for vascular lesions of the cord is stressed.

Adolescent↗

Internal mammary artery angiography should be a routine component of diagnostic coronary angiography.

Left internal mammary artery (LIMA) angiography was performed with diagnostic coronary angiography in 130 cases for which the coronary findings made use of the LIMA as a bypass graft a consideration. In 98% of the cases the approach to LIMA angiography was femoral with a 5F LIMA catheter first directed into the proximal subclavian and then advanced over a guidewire placed into the distal subclavian well beyond the origin of the LIMA. After withdrawing the wire the catheter was brought proximally to selectively cannulate and visualize the LIMA with nonionic contrast media. The only complication was a single transient occipital visual field loss. LIMA caliber too narrow to permit use as a graft was found twice, LIMA occlusion unrelated to prior surgery was found once, and LIMA occlusion related to prior surgery was found twice. Subclavian and/or vertebral stenosis was present five times. Large proximal branches of the LIMA best identified prior to surgery were present 12 times. Based on this experience, LIMA angiography 1) can be performed safely with a high degree of success, 2) demonstrates significant findings in 15% of cases, and 3) should therefore be performed whenever coronary angiographic findings make it appropriate to consider LIMA to coronary artery bypass grafting.

Adult↗

Magnetic resonance angiography (MRA) of the circle of Willis: a prospective comparison with conventional angiography in 54 subjects.

We prospectively correlated the findings of magnetic resonance angiography (MRA) with those of transfemoral four-vessel angiography in 54 patients to investigate the direction of flow within the circle of Willis. Our primary goal was to assess the direction of flow using the size of the vessel and signal intensity, without saturation techniques. Analysis of the circle of Willis, especially the communicating arteries, was performed double-blind by two groups of two radiologists. Three types of arteries were identified: high flow or cross-cerebral circulation, patent and nonvisualised arteries. Cerebral angiography was the standard for comparison between the two methods. MRA did not reveal any arteries invisible on angiography, thus providing a specificity of 100%. The sensitivity of MRA was 89.2% for the anterior and 81.3% for the posterior communicating arteries, and 100% for the anterior, middle and posterior cerebral arteries. MRA was shown to be a useful technique for the assessment of patency of the circle of Willis.

Adolescent↗

Magnetic resonance angiography and selective angiography following extra-intracranial bypass operations.

Magnetic resonance angiography (MRA) was compared with conventional angiography in 14 patients following extra-intracranial arterial anastomosis. In 13 patients the bypass was shown by MRA and confirmed by conventional angiography. In five of these, the anastomosed vessels, in particular the superficial temporal artery, was of the same calibre or smaller than the same vessels on the contralateral, healthy side. In one patient no anastomosis could be shown by MRA, and occlusion of the bypass was confirmed by conventional angiography. Absence of dilatation of the anastomotic vessels may indicate insufficient bypass function due to stenosis or an incorrect indication for surgery.

Adult↗

Magnetic resonance angiography of intracranial aneurysms: comparison with intra-arterial digital subtraction angiography.

Magnetic resonance angiography (MRA) with flow rephased gradient-echo sequences is a new non-invasive method for vascular imaging. We compared MRA and intra-arterial digital subtraction angiography in 18 patients with intracranial aneurysms to test whether MRA presently provides an alternative to cerebral angiography for the diagnosis of these anomalies. MRA showed 19 of the 22 aneurysms detected (86.4%). However, problems, especially with turbulent or slow flow, resulted in 6 studies (27.3%) with limited and 2 with questionable demonstration of an aneurysm, and 1 false negative study. At present, MRA is definitely inferior to angiography for the demonstration of intracranial aneurysms, due to its lower resolution and other limitations.

Adult↗

CT angiography in the evaluation of intracranial occlusive disease with collateral circulation: comparison with MR angiography.

The purpose of this study is to determine whether three-dimensional computed tomography angiography (CTA) is superior to magnetic resonance angiography (MRA) in the evaluation of collateral circulation in patients with intracranial arterial occlusive disease. Conventional angiography was used as the standard reference. Collateral vessels were well visualized by CTA, but not by MRA, while conventional angiography revealed leptomeningeal collateral vessels that were filled in a retrograde fashion. CTA is superior to MRA for evaluating collateral vessels.

Adolescent↗

Evaluation of live renal donors with three-dimensional contrast-enhanced magnetic resonance angiography in comparison to catheter angiography.

BACKGROUND: Catheter angiography is traditionally used to determine renal arterial anatomy in live renal donors. Three-dimensional (3D) contrast-enhanced magnetic resonance imaging (MRA) has been suggested as a noninvasive replacement. We assessed the possibility of using MRA in live renal donors in Malaysia. METHODS: Twenty-six consecutive live renal donors were recruited from 2000 to 2002. All potential donors underwent evaluation of the renal arteries using both techniques. Angiographic findings from both modalities were subsequently compared with surgical findings at the time of donor nephrectomy. The total number and diameter of the arteries and the presence of early branching and renal abnormalities were noted. RESULTS: Both angiographic modalities were able to detect multiple renal arteries with catheter angiography having a sensitivity of 100% and MRA a sensitivity of 97%. MRA missed one 1-mm artery due to a low index of suspicion. Renal artery caliber measurements were not significantly different between the two methods. However, both techniques tended to overestimate the caliber of the renal arteries when compared with measurements taken at surgery. Early branching was found in two arteries at the time of surgery, but only one was detected by both techniques. Renal cysts seen on MR were not detected by catheter angiography. CONCLUSIONS: Our findings suggest that noninvasive MRA is a promising substitute for catheter angiography to evaluate the renal arteries of live donors.

Adult↗

Three-dimensional time-of-flight MR angiography of the arch of aorta and its major branches: a comparative study with contrast angiography.

The region of the arch of aorta and the intrathoracic course of its major branches was evaluated in 11 patients using three-dimensional time-of-flight magnetic resonance (MR) angiography. Abnormalities such as stenosis, occlusion, dilatation and aneurysm formation were documented in the innominate, both common carotid and both subclavian arteries. The results were compared with those of contrast angiography. There was a good correlation in 47 of the 55 arteries compared. There were five false positive results including overestimation of a stenosis, and three false negative results including underestimation of a stenosis. MR angiography had a sensitivity of 93% and a specificity of 89% for correctly detecting or excluding an abnormality. These results suggest that three-dimensional time-of-flight MR angiography demonstrates lesions in the major branches of the arch of aorta fairly accurately and will prove useful in the initial evaluation and in follow up studies.

Adolescent↗

Rotational digital subtraction carotid angiography: technique and comparison with static digital subtraction angiography.

Recent advances in angiography equipment have allowed the development of rotational digital subtraction carotid angiography. We give the first description of this technique applied to the extracranial carotid circulation, using the Phillips Integris V3000 release 11. Forty-three patients undergoing conventional digital subtraction angiography were compared with 63 patients who had rotational digital subtraction angiography for examination of the extracranial carotid circulation. The parameters compared were: total procedure time, volume of contrast injection, number of contrast injections, total data acquisition time, image quality, radiation dose and patient comfort. There was a reduction in the total procedure time, improvement in patient comfort, data acquisition time and a reduction in the number of injections. Conventional DSA may underestimate stenoses in 65% of cases. There is no significant change in the total volume of contrast injected. There is, however, an increase in the radiation dose during data acquisition.

Angiography, Digital Subtraction↗

Fluorescent dots in fluorescein angiography and fluorescein leukocyte angiography using a scanning laser ophthalmoscope in humans.

PURPOSE: The purpose of the study is to disclose the nature of fluorescent dots and segments traditionally observed with fluorescein angiography (FA) using a scanning laser ophthalmoscope (SLO 101; Rodenstock, München, Germany). The authors developed a new method, called fluorescein leukocyte angiography (FLA), to display directly the movement of leukocytes in human retinal vessels. METHODS: Fluorescein angiography was performed on two normal volunteers using a scanning laser ophthalmoscope and fluorescent dots and segments were observed. Fluorescein leukocyte angiography, using an injection of fluorescent buffy coat layer from which the fluorescent plasma and nonfluorescent erythrocytes have been removed externally, was performed on seven normal volunteers. Injection fluid smears were examined through a fluorescent microscope. Peripheral blood smears taken during midphase of FA and FLA also were examined. In addition, 15 early-phase FAs of central serous chorioretinitis (CSC) were studied retrospectively. RESULTS: In the FAs of normal volunteers, fluorescent dots were detected only in perimacular capillaries at early phase. Eight of the 15 CSC FAs examined showed both fluorescent dots and segments. In the FLAs, fluorescent dots were detected in whole retinal vessels for more than 30 minutes. Fluorescent segments were observed in FA but not in FLA. Injected fluid smears from one FLA showed fluorescent leukocytes and small platelets. However, in peripheral blood smears of the FLA, leukocytes and platelets were more visible and exhibited higher contrast than those of an FA due to background plasma fluorescence. The mean velocity of 21 flowing leukocytes in perifoveal capillaries was 1.37 +/- 0.35 mm/second in 2 FAs and that of 89 flowing leukocytes was 1.41 +/- 0.29 mm/second in 7 FLAs. CONCLUSIONS: The authors' observations suggest that fluorescent dots in scanning laser ophthalmoscope imaging are fluorescein-stained leukocytes, whereas fluorescent segments are the hyperfluorescent plasma that is located between rouleaux formations of erythrocytes. The velocity of the fluorescent dots could be measured in the perimacular capillaries by either FA or FLA; however, only FLA can display the flow of fluorescent leukocytes in large vessels.

Adult↗

[Diagnostic significance of intravenous digital subtraction angiography of the supra-aortic extracranial vascular system. Comparative study of i.v. DSA and plain film angiography].

Digital intravenous subtraction angiography (DSA) and conventional film angiography were used to evaluate the diagnostic reliability of DSA-examinations. In 90% of 650 DSA-angiogramms the image quality was diagnostic. For 124 carotid angiographies a comparison of both methods was possible and gave a sensitivity of 87%, a specificity of 96% and an accuracy of 90% for the DSA examinations. The authors believe that digital subtraction angiography is suitable as a screening method for supraaortal vascular occlusive diseases.

Aged↗

Operative angiography by intraarterial digital subtraction angiography: a new technique for quality control of carotid endarterectomy.

Fifty patients who had carotid bifurcation endarterectomy as their sole surgical procedure underwent intraoperative completion angiography by means of portable intraarterial digital subtraction angiography. All had subsequent intravenous digital subtraction angiography or duplex scanning during early follow-up. After the endarterectomy site was closed and before the wound was closed, 6 to 8 ml of contrast was injected through a 21-gauge needle while fluoroscopy was performed with a conventional C-arm. The C-arm was coupled to a Quantel IDIS Mobile Digital Subtraction Angiogram Unit (Quantel Medical Products Group, Clemmons, N.C.) for image enhancement and immediate playback. There were no postoperative deaths or neurologic complications. Abnormal radiographic results led to reopening of endarterectomy sites in eight patients, which resulted in successful correction of the defects. There was a single asymptomatic occlusion of the internal carotid artery at 3 weeks in the patient with the only false-negative result on the completion study. Intraarterial digital subtraction angiography is a safe and useful technique for intraoperative quality control of carotid endarterectomy. It provides visual images that can be easily repeated in several projections, uses small volumes of contrast, and has no timing requirements for filming and injecting.

Carotid Artery Diseases↗

Perioperative evaluation of carotid endarterectomy by 3D-CT angiography with refined reconstruction: preliminary experience of CEA without conventional angiography.

Three-dimensional CT angiography (3D-CTA) was employed for perioperative evaluation of carotid endarterectomy (CEA) as an alternative to conventional angiography. A total of 62 carotid arteries were examined before and after CEA, 26 with an early 3D-CT system and 36 with multidetector helical CT allowing sophisticated reconstruction by a personal workstation. In addition to patients who had undergone conventional angiography at other institutes, 10 subjects underwent CEA on the basis of 3D-CTA findings alone. The findings provided detailed information with an excellent view of carotid stenoses. Volume rendering images comprehensively visualized lesions and surrounding structures as well as calcifications, which were also well depicted by maximum intensity projection images. Evaluation of the cerebral circulation is one problem that still requires solution, although cerebral vessels were delineated by 3D-CTA. One patient experienced transient hemiparesis, but no significant permanent deficit. We conclude that 3D-CTA is a safe and accurate modality that is a practical alternative to conventional perioperative angiography.

Aged↗

Reliability of hepatic artery configuration in 3D CT angiography compared with conventional angiography--special reference to living-related liver transplant donors.

Although an accurate anatomical understanding of the hepatic arteries is the most and essential step in living-related liver transplantation (LRLT), the need to reduce the burden place on the donor should be considered in imaging diagnosis. The present study examined the reliability of intravenously enhanced three-dimensional (3D) angiography from multidetector-row computed tomography (MDCT) in evaluating the anatomical configuration of the hepatic arteries comparing with those from conventional angiography by Seldinger method. A total of 109 patients underwent MDCT and 3D images were reconstructed on arterial phase using the volume rendering (VR) method. In the case of 3D angiography, at an infusion rate of 4 ml/s, the extrahepatic hepatic arteries were visualized successfully in all cases (the right, left and middle hepatic artery). The aberrant hepatic arteries were successfully visualized in 23 of 24 cases. The 3D angiography is a reliable method of visualizing the extrahepatic and aberrant hepatic arteries. This minimally invasive examination procedure is useful in individual operative planning and is help to increase the safety of surgery.

Adult↗

Carotid artery: prospective blinded comparison of two-dimensional time-of-flight MR angiography with conventional angiography and duplex US.

A prospective blinded comparison of two-dimensional (2D) time-of-flight (TF) magnetic resonance (MR) angiography and color duplex flow ultrasound (US) with conventional angiography as a standard of reference was performed in 50 patients with hemispheric ischemic symptoms. The guidelines of the North American Symptomatic Carotid Endarterectomy Trial for measuring stenosis of the internal carotid artery were utilized for maximum-intensity-projection (MIP) images and conventional angiograms. While the 2D TF MIP technique overrepresented the degree of stenosis in the internal carotid arteries, it matched the performance of color duplex flow US as measured by means of receiver operating characteristic curves. A signal void on the MIP images corresponded to a 70% or greater internal carotid artery stenosis in 17 of 20 arteries. At its current state of development, the accuracy of 2D TF MR angiography equals that of US in characterizing the degree of carotid stenosis but cannot be considered a replacement for conventional angiography.

Adult↗

Mild carotid artery atherosclerosis: assessment by 3-dimensional time-of-flight magnetic resonance angiography, with reference to intravascular ultrasound imaging and contrast angiography.

BACKGROUND AND PURPOSE: Our aim was to evaluate the usefulness of 3-dimensional time-of-flight magnetic resonance angiography (3-D TOF MRA) in detection and quantification of mild atherosclerotic changes of carotid arteries with reference to intravascular ultrasound (IVUS) and contrast angiography. METHODS: TOF MRA at 1.5 T, IVUS, and selective digital subtraction angiography were performed on 31 extracranial carotid arteries of 27 patients (mean age, 52 years; age range, 17 to 75 years) undergoing neuroendovascular interventions. The atherosclerotic lesions were registered, and quantitative measurements of plaque thickness, luminal diameters, and diameter stenosis were independently performed for the imaging modalities. RESULTS: Among 170 arterial segments analyzed, IVUS revealed a total of 48 atherosclerotic lesions (mean diameter stenosis, 17%; range, 4% to 40%), only 25 of which were depicted on digital subtraction angiography. Analysis of the axial source images of TOF MRA resulted in sensitivity of 77% to 83% and specificity of 71% to 80% in lesion depiction for the 2 readers with reference to IVUS. The values of diameter stenosis measured from MRA and IVUS were closely interrelated (r=0.53 to 0.61, P<0.001). CONCLUSIONS: Three-dimensional TOF MRA is feasible and moderately accurate for evaluation of mild atherosclerotic changes of carotid arteries.

Adolescent↗

High-resolution spiral computed tomography coronary angiography in patients referred for diagnostic conventional coronary angiography.

BACKGROUND: The diagnostic performance of the latest 64-slice CT scanner, with increased temporal (165 ms) and spatial (0.4 mm3) resolution, to detect significant stenoses in the clinically relevant coronary tree is unknown. METHODS AND RESULTS: We studied 52 patients (34 men; mean age, 59.6+/-12.1 years) with atypical chest pain, stable or unstable angina pectoris, or non-ST-segment elevation myocardial infarction scheduled for diagnostic conventional coronary angiography. All patients had stable sinus rhythm. Patients with initial heart rates > or =70 bpm received beta-blockers. Mean scan time was 13.3+/-0.9 seconds. The CT scans were analyzed by 2 observers unaware of the results of invasive coronary angiography, which was used as the standard of reference. All available coronary segments, regardless of size, were included in the evaluation. Lesions with > or =50 luminal narrowing were considered significant stenoses. Invasive coronary angiography demonstrated the absence of significant disease in 25% (13 of 52), single-vessel disease in 31% (16 of 52), and multivessel disease in 45% (23 of 52) of patients. One unsuccessful CT scan was classified as inconclusive. Ninety-four significant stenoses were present in the remaining 51 patients. Sensitivity, specificity, and positive and negative predictive values of CT for detecting significant stenoses on a segment-by-segment analysis were 99% (93 of 94; 95% CI, 94 to 99), 95% (601 of 631; 95% CI, 93 to 96), 76% (93 of 123; 95% CI, 67 to 89), and 99% (601 of 602; 95% CI, 99 to 100), respectively. CONCLUSIONS: Noninvasive 64-slice CT coronary angiography accurately detects coronary stenoses in patients in sinus rhythm and presenting with atypical chest pain, stable or unstable angina, or non-ST-segment elevation myocardial infarction.

Aged↗

[A case of subarachnoid hemorrhage verified as cerebral vasospasm by using three-dimensional CT angiography (3 D-CTA): reference to comparison with conventional angiography].

The authors present a case of aneurysmal subarachnoid hemorrhage that were verified as cerebral vasospasm by using both three-dimensional CT angioraphy (3 D-CTA) and conventional angiography. A 45-year-old man was referred to our department 4th day after sudden onset of a severe headache. On admission, emergency 3 D-CTA showed the cerebral vasospasm involving M 1 segment. Conventional angiography performed at the same day of the left internal carotid artery confirmed the cerebral vasospasm of the same vessel as 3 D-CTA, and furthermore demonstrated the left middle cerebral artery (MCA) and anterior cerebral artery (ACA) genu aneurysms. The former was seen as a ruptured aneurysm from brain CT findings (Fisher group 3). On the 10th day after the onset, 3 D-CTA demonstrated the remaining severe cerebral vasospasm of the supraclinoid portion of left ICA and M 1 segment. Findings at the conventional angiography subsequently performed were concordant with those of 3 D-CTA. The patient was successfully treated with delayed surgical clipping for both aneurysms without the symptoms related to the cerebral vasospasm and discharged without neurological abnormality. We consider that 3 D-CTA shows promise as a minimally invasive method of evaluating the cerebral vasospasm and would take the place of the conventional angiography.