PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Denture, Partial, Removable”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14Linked to original sources

Etched castings as an adjunct to mouth preparation for removable partial dentures.

Electrochemically etched nonprecious metal castings have been bonded to etched enamel for use in mouth preparation procedures for removable partial denture placement. The castings have been in service and subject to loading by the dentures for 26 to 42 months. To date, bond strengths have been sufficient to support function of both castings and removable partial dentures clinically. None of the castings has failed in its bond. Evidence that the technique may be a valuable adjunct is building in the field of prosthodontics. Use may be far reaching as dentists apply the concept to a wide variety of patient requirements in dental treatment. As more commercial dental laboratories acquire the capability to etch metals, cost should be minimized. Application is not time-consuming. Some steps are technique-sensitive, however, and short cuts are not well tolerated. This is especially true of cementation procedures where moisture or contamination of the field may lead to failure of the bond. It should be noted that each nonprecious metal is different from other metals in its composition, and therefore, results and techniques reported in this study can only be cited for the metal used. In addition, the acid used for etching one alloy may not be effective on another alloy. Finally, it is important that all castings be checked under a binocular microscope to ensure that proper etching did occur. Underetching and overetching both lead to a weakened bond and potential failure.

Acid Etching, Dental↗

Clinical evaluation of removable partial dentures 10 years after insertion: success rates, hygienic problems, and technical failures.

The aim of this retrospective study was to examine the condition and success rate of various designs of removable partial dentures 10 years after placement. Seventy-four patients treated with 101 mainly conical crown-retained dentures (CCRDs), clasp-retained removable partial dentures (RPDs), or a combination of conical crown and clasp-retained dentures (CRPDs) were reexamined. Prosthetic findings were compared to baseline values at insertion and checked for factors that may affect them. Overall, 36.6% of the prostheses were regarded as successes, 23.8% as partial successes, and 39.6% as failures. Also, only one-third of the prostheses showed neither hygienic problems nor technical failures. The statistical analysis identified no single parameter as significantly affecting the success rate of the partial dentures. Prostheses supported by several abutment teeth had improved success, and RPDs had a higher failure rate (66.7%) than CCRDs (33.3%) and CRPDs (44.8%); however, because of the limited number of RPDs these differences were not statistically significant. Although the prostheses were unsupervised in service, the 60.4% overall success rate of the dentures was somewhat higher than in other studies on precision-retained prostheses.

Chi-Square Distribution↗

Removable partial denture design: importance of clinical variables.

A study was conducted to ascertain the influence of clinical variables on removable partial denture design. Dentures were first designed using only the information usually available to technicians, namely, surveyed, articulated study casts. These designs were then modified using information available to the dentist, that is, clinical variables. Of the 208 dentures analysed, 80 (39%) needed modification to 171 components because of patient-related variables. This high number of modifications reinforces the position that removable partial denture design should be instigated and guided by the dentist.

Dental Occlusion, Traumatic↗

Fabricating a gold occlusal platform on a removable partial denture to help prevent extrusion of mandibular incisors.

A clinical procedure is presented in which a maxillary removable partial denture replacing anterior teeth was fabricated with a cast gold anterior occlusal platform. This treatment is indicated to correct abrasion caused by extruded mandibular anterior teeth on the maxillary removable partial denture. The advantages compared to prosthetic teeth supported by an acrylic resin base or metal-backed facings are discussed. This technique allows for development of optimal esthetics, strength, and durability while preventing further extrusion and excessive wear of the teeth occluding against prosthesis.

Denture Design↗

Evaluation of cobalt, chromium, and nickel concentrations in plasma and blood of patients with removable partial dentures.

This study assessed the plasma and blood concentrations of Cr, Co, and Ni among subjects using removable partial dentures. A comparison was made between subjects with and without RPD treatment history. Control group consisted of 10 healthy individuals without dentures. Concentrations of Cr, Co, and Ni in subjects' plasma and blood were measured with an atomic absorption spectrophotometer. Data were statistically analyzed by ANOVA, and multiple comparison test (alpha = 0.05) was used to identify significant differences between groups. RPD use had a significant effect on the concentrations of Cr (P < 0.001) and Ni (P < 0.05) in blood and plasma. As such, there were statistically significant differences between the control and study groups for the concentrations of Cr and Ni in blood and plasma. However, RPD use exhibited no significant effect on Co concentration in plasma. In conclusion, the use of removable partial dentures with metal frameworks led to an increase in the concentrations of Cr and Ni in both blood and plasma.

Analysis of Variance↗

Comparison of cast Ti-Ni alloy clasp retention with conventional removable partial denture clasps.

STATEMENT OF PROBLEM: The elastic property of Ti-Ni alloy may be a desirable property for cast removable partial dentures. However, little is known about the retentive properties of cast Ti-Ni alloy clasps. PURPOSE: This in vitro study investigated the retentive force of various types of clasps during repeated cycles of placement and removal to determine whether Ti-Ni alloy clasps maintain their initial retentive force under varied conditions, including different retentive undercut depths and clasp size (thickness and width). MATERIAL AND METHODS: The test models were developed using a mandibular dentiform with a horizontal plane of occlusion. Two complete metal abutment crowns were made for the left second molar, differing only in retentive undercut depths. A total of 98 clasps (n=7) were fabricated, including 14 wrought wire clasps and 28 clasps from each of the following alloys: Co-Cr alloy (Biosil), Type IV gold alloy (Cast-4), and Ti-Ni alloy (TN-10). Clasps were made to engage one of 2 retentive undercut depths (0.25 mm or 0.75 mm) and were made in 2 sizes (0.8 mm or 1.4 mm). Each clasp was radiographically examined for casting defects and porosity. The force (N) required to remove the clasps was measured using a universal testing machine with a crosshead speed of 10 mm/min. After measuring the retentive force, a masticatory simulator was used to cycle the clasps on and off the metal crown 500 times, simulating the insertion and removal of a removable partial denture clasp. The cycling sequence was repeated 10 times, and retention force was measured after each sequence. The internal surface of the clasp arms was examined for evidence of metal fatigue using scanning electron microscopy. Data were subjected to 2-way and 4-way analysis of variance, followed by Scheffe's multiple comparison test (alpha=.05). RESULTS: Co-Cr alloy and gold alloy clasps in the 0.25-mm retentive undercut groups experienced a gradual decrease in retentive force measurements (P<.001). In contrast, the Ti-Ni alloy clasps maintained a retentive force of approximately 1.8 N and 2.6 N for the 0.8 mm and 1.4 mm clasp groups, respectively. Although Ti-Ni alloy clasps' retentive force was reduced slightly after the first cycling sequence, it was negligible compared with other clasps tested. The wrought wire clasps also retained their retentive force until the final cycling sequence. A similar trend was found in the clasp groups engaging 0.75-mm retentive undercuts. CONCLUSION: Although the end-point retention for all the clasps was similar, there was less change in the retentive force of the cast Ti-Ni alloy clasps after repeated cycling sequences of simulated placement and removal.

Analysis of Variance↗

Longitudinal study on torque transmitted from denture base to an abutment tooth of lower distal-extension removable partial dentures with conus crown telescopic system.

The purpose of this study was to make a longitudinal analysis of torque transmitted to a direct abutment tooth of a lower distal-extension removable partial dentures constructed with the conus crown telescopic system. Torque around the vertical and lateral axes of the tooth were measured during chewing of food at the time of insertion of the new dentures to about three months after. The maximal mean value of torque (Max.MT) was calculated from the peak level of all chewing strokes at the minimum of the interocclusal distance. The integration values of torque (I) and time (T) from initiation of chewing to swallowing were obtained, then the average value of torque (Ave.T) was calculated (Ave.T = I/T). The results are summarized as follows: (a) There were no remarkable changes of Max.MT around the both axes; (b) Max.MT around the lateral axis was 7-47 x 10(-3) kgm (mean: 25 x 10(-3) kgm) (1 kgm = 9.8 Nm) in the downward direction and Ave.T around the lateral axis was 6-14 x 10(-3) kgm ss-1 (mean: 10 x 10(-3) kgm ss-1) in the downward direction; (c) There were marked differences of Max.MT and Ave.T around the vertical axis between subjects. Max.MT around the vertical axis was less than 24 x 10(-3) kgm and Ave.T around the vertical axis was less than 6 x 10(-3) kgm ss-1.

Aged↗

[Removable partial dentures applied by electric welding and soldering methods].

The joining procedure for uniting metal structures is very important in the dental clinic, and various kinds of metal joining methods have been performed for clinical application. The conventional torch soldering method using a blow torch has been generally adopted. However, it has several clinical problems, especially in the construction of removable partial dentures. The base metal wires made of a chromium-cobalt alloy are subject to changes in their mechanical properties caused by heating, when wrought wire clasps are joined to rests or frameworks. In addition to the flexibility of wrought wire clasps, damage to acrylic resin denture bases and acrylic resin teeth occurs in the repair of removable partial dentures. In this paper, the electric resistance welding and soldering methods were applied to attach wrought wire components to a removable partial denture framework to resolve the problems of the torch soldering method. As a result, it is suggested that these electric resistance welding and soldering methods have the following advantages, as compared with the conventional torch soldering method. 1. When using this electric resistance welding method, it is possible to fix metals temporarily to each other more securely and strongly than the conventional temporary fixation methods using sticky wax or acrylic resin. 2. The electric resistance soldering method does not require any heat insulation or a partition as the torch soldering method does, because the soldered area is only heated partially. 3. In the case of soldering electrically wrought wire clasps to metal structures such as rests and connectors, there is no fear of of overheating a wide area of wires.(ABSTRACT TRUNCATED AT 250 WORDS)

Chromium Alloys↗

The effect of removable partial denture framework design on gingival inflammation: a clinical model.

A clinical trial using the experimental gingivitis model developed for periodontal clinical research was performed to evaluate the effect of a removable partial denture mandibular major connector design on the surrounding gingival tissues. A comparison of the state of health of adjacent gingival tissues was made between the linguoplate (control) and cingulum bar (test) major connectors. Clinical parameters were recorded in a single-blind crossover experimental gingivitis trial. Subjects were brought to a level of optimal gingival health and then randomly assigned to use one framework design while refraining from any oral hygiene. Measurements were made at 7-day intervals for 21 days. The subjects were returned to optimal oral health and repeated the experimental period with the alternate design. Results showed a greater increase in mean gingival inflammation with the control than with the test removable partial denture, suggesting that the cingulum bar has fewer detrimental effects on gingival tissues than the linguoplate major connector. Results of this study suggest that the experimental gingivitis model can be a useful and valid system for studying the potential effects of a removable partial denture design on surrounding oral tissues.

Adult↗

Radiographic and metallographic evaluation of porosity defects and grain structure of cast chromium cobalt removable partial dentures.

A study was undertaken to determine the defects in the internal microstructure of clasps of cast chromium cobalt removable partial denture frameworks. Ninety cast frameworks were radiographically evaluated for porosity with an industrial radiographic machine. The grain structure of the clasps was analyzed with an optical photomicroscope before and after various heat treatments. The radiographic study showed a large number of internal defects in various parts of removable partial denture frameworks. The grain structure study revealed microporosities randomly distributed within the matrix. Various heat treatments were performed and resulted in no change in the grain structure of the original castings.

Chromium Alloys↗

Support of removable partial dentures in situations with a unilaterally missing canine and a curved edentulous ridge.

The load and movement of abutments and removable partial dentures were examined in situations with a unilaterally missing canine and a curved edentulous ridge. These measurements were performed on a model adapted to intraoral conditions. In this simulation, removable partial dentures supported by incisors may result in failure. Spring rest support results in significantly reduced articulation vertically and horizontally when compared with solid rest support and avoids periodontal overloading.

Analysis of Variance↗

Comparison of the in vitro fatigue resistance of an acrylic resin removable partial denture reinforced with continuous glass fibers or metal wires.

PURPOSE: The fatigue resistance of heat-polymerized acrylic resin test specimens reinforced with continuous glass fibers or metal wire was investigated. MATERIALS AND METHODS: Test specimens in the shape of maxillary removable partial dentures were reinforced with one of the following: (1) circular steel wire (cross-sectional diameter, 1.0 mm); (2) semicircular steel wire (cross-sectional diameter, 1.0 x 2.0 mm); or (3) continuous unidirectional E-glass fibers. Ten specimens were fabricated for each test group. The specimens were tested by a constant force flexural fatigue test at a force of 180 N while immersed in 37 degrees C water. The number of loading cycles required to generate a fatigue fracture and the position of the fracture were measured. RESULTS: Results showed that the test specimens, which were either unreinforced or reinforced with metal wires, fractured after 13,197 to 39,237 loading cycles. For the glass fiber-reinforced test specimens, the fracture did not coincide with the region of the strengthener but with the opposite side of the test specimen after 1,239,298 loading cycles. The position of the fracture showed a statistically significant variation between the test groups (P < .001). CONCLUSIONS: This study suggests that the fatigue resistance of acrylic resin removable partial dentures reinforced with glass fibers are superior to those removable partial dentures reinforced with conventional metal wire.

Analysis of Variance↗

The mandibular first premolar as an abutment for distal-extension removable partial dentures: a modified clasp assembly design.

Sound mandibular first premolars can be used as sole abutments for bilateral distal-extension removable partial dentures, if the denture is designed to minimise the torque applied to the abutment teeth. A simplified modification of the conventional torque-releasing clasp-assembly designs is suggested for these teeth. This modification entails a mesial rest on each abutment tooth connected to the distal proximal plate via a lingual bracing arm. A circumferential clasp arm is optional for buccal retention of the removable partial denture. As with conventional designs, the metal framework is designed to permit some rotational tissueward movement of the distal extension bases, yet not compromise the retention and stability of the prosthesis.

Bicuspid↗

Periodontal considerations in removable partial denture treatment: a review of the literature.

PURPOSE: A critical review of the literature on the periodontal considerations in removable partial denture (RPD) treatment is presented. MATERIALS AND METHODS: A MEDLINE search was conducted for studies pertaining to the effects of RPDs on the periodontal tissues during the various phases of prosthetic treatment. The review included both in vivo and in vitro studies. RESULTS: The use of RPDs leads to detrimental qualitative and quantitative changes in plaque. There seems to be a lack of information regarding the effects of RPDs on the status of periodontally compromised abutments. A number of studies, mainly in vitro, have failed to agree on the ideal RPD design. Clinical trials have shown that if basic principles of RPD design are followed (rigid major connectors, simple design, proper base adaptation), periodontal health of the remaining dentition can be maintained. CONCLUSION: Removable partial dentures do not cause any adverse periodontal reactions, provided that preprosthetic periodontal health has been established and maintained with meticulous oral hygiene. Frequent hygiene recalls and prosthetic maintenance are essential tools to achieve a good long-term prognosis. More prospective clinical trials are needed on the effect of RPDs on the condition of periodontally involved abutment teeth.

Dental Abutments↗

Chewing patterns before and after treatment with completè maxillary and bilateral distal-extension mandibular removable partial dentures.

Prosthodontic rehabilitation with complete maxillary dentures and mandibular bilateral distal-extension removable partial dentures did not change the general masticatory function to any great extent. However, the velocity of the mandible was increased, especially in the opening phase, and so was the mandibular displacement. The latter seems to be the cause for a long closing duration. The chewing cycle became more even and teardrop shaped, and the prosthodontic rehabilitation also resulted in a decrease of the number of chewing cycles. The Selspot system offers a possibility to study adaptation to prosthodontic treatment objectively by measurements of time and movement.

Adaptation, Physiological↗

Future needs for fixed and removable partial dentures in the United States.

STATEMENT OF PROBLEM: Because of the decline in missing teeth among most adults, prosthodontic advanced training programs are concerned about the need for prosthodontics in the future. PURPOSE: An analysis was conducted to project the unmet need for fixed and removable partial dentures in the years 2005, 2010, and 2020. MATERIAL AND METHODS: Unmet need was calculated as follows: Total need equals the number of persons in each age cohort multiplied by the percentage who need a fixed or removable partial denture multiplied by the average procedure time required to provide the service. Total unmet need then equals total need minus the annual supply of prosthodontic services delivered by prosthodontists and general practitioners. RESULTS: Projected results indicate that total unmet need will increase from 488 million hours in 2005 to 517 million hours in 2010 and to 560 million hours in 2020. CONCLUSION: The significance of the results is that unmet prosthodontic need will increase and exceed the supply of services for the foreseeable 20-year future. Practicing dentists will find that a sizable minority of the population will continue to need fixed and removable partial denture services.

Adult↗