Steady-state limiting currents at finite conical microelectrodes.

The investigation of steady-state diffusion-limiting currents at finite conical microelectrodes is reported. Such electrodes are of particular interest as probes in studies of kinetic reactions, measurements in microenvironments, and high-resolution electrochemical imaging. The diffusion-limiting currents were calculated using numerical (finite element) analysis and compared to those obtained at inlaid disk and hemispheroidal microelectrodes. Time-dependent simulations demonstrating the approach of the diffusion current to a steady-state value are also reported. The steady-state diffusion-limiting currents obtained were found to be a strong function of the electrode geometry, including the aspect ratio of the cone and the thickness of the insulating sheath. Thus, simple, approximate analytical expressions which account for these geometrical dependencies in the simulated steady-state diffusion-limited currents are also reported. As a limiting case, an analytical approximation was obtained for the steady-state current to a microdisk as a function of the insulator thickness. The use of these approximate equations in calculating electrode radii from steady-state diffusion-limiting currents is demonstrated, and good agreement was found with previously reported experimental studies. Use of the frequently implemented hemispherical theory to analyze steady-state diffusion-limiting currents obtained with finite conical microelectrodes is shown to result in an experimentally acceptable underestimation of the electrode radius.

Journal Article↗

Fabrication of integrated microelectrodes for electrochemical detection on electrophoresis microchip by electroless deposition and micromolding in capillary technique.

A new method for the fabrication of an integrated microelectrode for electrochemical detection (ECD) on an electrophoresis microchip is described. The pattern of the microelectrode was directly made on the surface of a microscope slide through an electroless deposition procedure. The surface of the slide was first selectively coated with a thin layer of sodium silicate through a micromolding in capillary technique provided by a poly(dimethylsiloxane) (PDMS) microchannel; this left a rough patterned area for the anchoring of catalytic particles. A metal layer was deposited on the pattern guided by these catalytic particles and was used as the working electrode. Factors influencing the fabrication procedure were discussed. The whole chip was built by reversibly sealing the slide to another PDMS layer with electrophoresis microchannels at room temperature. This approach eliminates the need of clean room facilities and expensive apparatus such as for vacuum deposition or sputtering and makes it possible to produce patterned electrodes suitable for ECD on microchip under ordinary chemistry laboratory conditions. Also once the micropattern is ready, it allows the researchers to rebuild the electrode in a short period of time when an electrode failure occurs. Copper and gold microelectrodes were fabricated by this technique. Glucose, dopamine, and catechol as model analytes were tested.

Journal Article↗

Microelectrode array microscopy: investigation of dynamic behavior of localized corrosion at type 304 stainless steel surfaces.

Scanning electrochemical microscopy (SECM) and a recently developed microelectrode array microscope have been used to study localized corrosion and electron-transfer characteristics of native oxide layers of type 304 stainless steels. The I-/I3- redox couple was employed as a mediator and allowed sensitive detection of oxide breakdown events. In solutions containing I-, a signal at the microelectrode was observed on type 304 stainless steel surfaces at active pitting corrosion sites. Under conditions where pitting corrosion occurs, SECM was used to track the temporal characteristics of the reaction in a spatial manner. However, because of the time required to create an image, much of the temporal information was not obtained. To improve the temporal resolution of the measurement, microelectrode array microscopy (MEAM) was developed as a parallel method of performing SECM. The demonstration shown reveals the potential of MEAM for analysis of surface chemistry on temporal and spatial domains.

Journal Article↗

High frequency faradaic rectification voltammetry at microelectrodes.

An experimental setup for carrying out faradaic rectification measurements at micrometer-sized electrodes under potential control is described. A new method of data analysis is proposed that allows the determination of the standard rate constant and the electron-transfer coefficient of a fast charge transfer process without knowing the impedance of the microelectrode. This method is based on the frequency dependence of the shape of the faradaic rectification voltammograms (i.e., the average width of the peaks and the ratio of the peak heights) rather than on the magnitude of the faradaic rectification signal. The method was tested in the determination of heterogeneous electron transfer kinetics of Fe(CN)6(3-/4-) and Ru(NH3)6(2+/3+) in aqueous solutions on a platinum microelectrode (12.5 microm in radius) and ferrocene/ferrocinum redox couple in a dimethylformamide solution on a gold microelectrode (12.5 microm in radius).

Journal Article↗

Alkanethiolate self-assembled monolayers as functional spacers to resist protein adsorption upon Au-coated nerve microelectrode.

Alkanethiolate self-assembled monolayers (SAMs) of varied chain lengths were adsorbed upon Au-coated nerve microelectrodes and employed as protein-resistant spacers. The microelectrode spiraled as a cuff type can be used for restoring motor function via electrical stimulation on the peripheral nerve system; however, an increase of electrode impedance might occur during implantation. In this work, a thin-film SAMs treatment upon Au/polyimide (PI) surface of the microelectrode provided a hydrophobic characteristic, which retarded protein adsorption at the initial stage and subsequent pileup (or thickening) process. The protein-resistant effect exhibited comparable SAMs of different chain lengths adsorbed upon Au/PI surfaces. The increase of electrode impedance as a function of protein deposition time was mainly correlated with the addition of reactance that was associated with the pileup thickness of the deposited protein. Particularly, the SAMs-modified surface was capable to detach a significant portion of the accumulated protein from the protein-deposited SAMs/Au/PI, whereas the protein-deposited layers exhibited firm adhesion upon Au/PI surface. It is therefore very promising to apply thin-film SAMs adsorbed upon Au-coated surface for bioinvasive devices that have the need of functional electrical stimulations or sensing nerve signals during chronic implantation.

Adsorption↗

Ca-selective microelectrodes and their application to plant cells and tissues.

The use of Ca(2+)-selective microelectrodes is difficult because of some basic problems: (a) electrodes with submicron tips may display non-Nernstian slopes; (b) liquid membrane microelectrodes respond only slowly (within seconds) to changes in ion activity; (c) turgid plant cells with tough walls damage the sensitive tip. This article describes concisely recent advances in fabricating Ca(2+)-selective single and double-barreled microelectrodes and their intracellular applications to different plant cell materials. Beveling the electrodes, mixing the sensor components with polyvinylchloride, insulation of the hydrated glass, and stabilization of the tips with inert materials are considered the basic concepts to circumvent most difficulties. It is concluded that the Ca(2+)-electrode can be a useful tool in plant physiology, but in spite of recent progress this technique remains experimentally demanding.

Journal Article↗

Measurement of net fluxes of ammonium and nitrate at the surface of barley roots using ion-selective microelectrodes.

Neutral carrier-based liquid membrane ion-selective microelectrodes for NH(4) (+) and NO(3) (-) were developed and used to investigate inorganic nitrogen acquisition in two varieties of barley, Hordeum vulgare L. cv Olli and H. vulgare L. cv Prato, originating in cold and warm climates, respectively. In the present paper, the methods used in the fabrication of ammonium- and nitrate-selective microelectrodes are described, and their application in the study of inorganic nitrogen uptake is demonstrated. Net ionic fluxes of NH(4) (+) and NO(3) (-) were measured in the unstirred layer of solution immediately external to the root surface. The preference for the uptake of a particular ionic form was examined by measuring the net flux of the predominant form of inorganic nitrogen, with and without the alternative ion in solution. Net flux of NH(4) (+) into the cold-adapted variety remained unchanged when equimolar concentrations (200 micromolar) of NH(4) (+) and NO(3) (-) were present. Similarly, net flux of NO(3) (-) into the warm-adapted variety was not affected when NH(4) (+) was also present in solution. The high temporal and spatial resolution afforded by ammonium- and nitrate-selective microelectrodes permits a detailed examination of inorganic nitrogen acquisition and its component ionic interactions.

Journal Article↗

A metaanalysis comparing the results of pallidotomy performed using microelectrode recording or macroelectrode stimulation.

OBJECT: There is an active debate regarding whether pallidotomy should be performed using macroelectrode stimulation or the more sophisticated and expensive method of microelectrode recording. No prospective, randomized trial results have answered this question, although personnel at many centers claim one method is superior. In their metaanalysis the authors reviewed published reports of both methods to determine if there is a significant difference in clinical outcomes or complication rates associated with these methods. METHODS: A metaanalysis was performed with data from reports on the use of unilateral pallidotomy in patients with Parkinson disease (PD) that were published between 1992 and 2000. A Medline search was conducted for the key word "pallidotomy" and additional studies were added following a review of the references. Only those studies dealing with unilateral procedures performed in patients with PD were included. Papers were excluded if they described a cohort smaller than 10 patients or a follow-up period shorter than 3 months or included cases that previously had been reported. The primary end points for outcome were the percentages of improvement in dyskinesias and in motor scores determined by the Unified PD Rating Scale (UPDRS). Complications were categorized as mortality, intracranial hemorrhage, visual deficit, speech deficit, cognitive decline, weakness, and other. There were no significant differences between the two methods with respect to improvements in dyskinesias (p = 0.66) or UPDRS motor scores (p = 0.62). Microelectrode recording was associated with a significantly higher (p = 0.012) intracranial hemorrhage rate (1.3 +/- 0.4%), compared with macroelectrode stimulation (0.25 +/- 0.2%). CONCLUSIONS: In reports of patients with PD who underwent unilateral pallidotomy, operations that included microelectrode recording were associated with a small, but significantly higher rate of symptomatic intracranial hemorrhage; however, there was no difference in postoperative reduction of dyskinesia or bradykinesia compared with operations that included macroelectrode stimulation.

Electrodes↗

Effect of nitrite and nitrate on biogenic sulfide production in sewer biofilms determined by the use of microelectrodes.

The effects of O2 and NO3- concentrations on in situ sulfate reduction and sulfide reoxidation in microaerophilic wastewater biofilms grown on rotating disk reactors were investigated by the use of microelectrodes for O2, S2-, NO3-, NO2-, and pH. Microelectrode measurements showed the vertical microzonation of O2 respiration, NO3- respiration, H2S oxidation and SO4(2-) reduction in the biofilms. The microelectrode measurements indicate that sulfate reducing activity was largely restricted to a narrow anaerobic zone located about 500 microm below the biofilm surface. An addition of nitrate forced the sulfate reduction zone deeper in the biofilm and reduced the specific sulfate reduction rate as well. The sulfate reduction zone was consequently separated from the O2 and NO3- respiration zones. Anaerobic H2S oxidation with NO3- was also induced by addition of nitrate to the medium. Measurements of the reduced inorganic sulfur compounds (FeS, FeS2 and S0), total-Mn and total-Fe in the biofilm indicated that the produced H2S became immediately oxidized with O2, NO3- and other oxidants, mainly ferric/ferrous hydrates. On the basis of the present results, it was estimated that of all sulfide produced, 13% of the sulfide was precipitated by metal ions as FeS and S0 just above the sulfate reduction zone, 65% was anaerobically oxidized to SO4(2-) with NO3- as an electron acceptor and 22% was aerobically oxidized within the biofilm incubated in 70 micromol l(-1) of DO and 280 micromol l(-1) of NO3-.

Biofilms↗

Electrochemical detection of allergen in small-volume whole blood using an array microelectrode: a simple method for detection of allergic reaction.

A safe, simplified, and rapid method for detection of allergen has been developed. Serotonin, a chemical mediator secreted during an allergic reaction, was used as a marker in electrochemical detection. A 20-microL drop of whole blood was used for the electrochemical detection of allergen using an array microelectrode. When cyclic voltammetry was carried out on whole blood samples containing 1 microg/mL serotonin, an anodic peak current appeared at around 350 mV versus a silver/silver chloride electrode using a Nafion-coated array microelectrode. Allergen was selectively detected using whole blood samples by applying a constant potential of 350 mV after 40 min incubation with addition of allergen. The results obtained by the electrochemical detection method correlated well with the diagnosis obtained from the amount of IgE antibody.

Adult↗

Effect of nitrite and nitrate on in situ sulfide production in an activated sludge immobilized agar gel film as determined by use of microelectrodes.

Microelectrode, fluorescence in situ hybridization (FISH), and denaturing gradient gel electrophoresis (DGGE) analyses were used to investigate the effect of nitrite and nitrate on in situ sulfide production in an activated sludge immobilized agar gel film. Microelectrode measurements of O(2), H(2)S, NO(3)(-), NO(2)(-), and pH revealed that the addition of NO(2)(-) and NO(3)(-) forced sulfate reduction zones deeper in the agar gel and significantly reduced the in situ sulfide production levels. The sulfate reduction zone was consequently separated from O(2) and NO(2)(-) or NO(3)(-) respiration zones with increasing the concentrations of NO(2)(-) and NO(3)(-). These NO(2)(-) and NO(3)(-) treatments had only a transient effect on sulfide production. The in situ sulfide production quickly recovered to the previous levels when NO(2)(-) and NO(3)(-) were removed. The PCR-DGGE and FISH analyses revealed that 2-day-continuous addition of 500 microM NO(3)(-) did not change the metabolically active sulfate-reducing bacterial (SRB) community. On the basis of these data, it could be concluded that the addition of NO(2)(-) and NO(3)(-) did not kill SRB, but induced the interspecies competition for common carbon source (i.e., acetate) between nitrate-reducing heterotrophic bacteria and SRB and enhanced the oxidation of the produced sulfide, which were main possible causes of the suppression of in situ sulfide production in the agar gel.

Agar↗

Electron microscopic studies of serially sectioned cat spinal alpha-motoneurons. I. Effects of microelectrode impalement and intracellular staining with the fluorescent dye "Procion Yellow".

Cat spinal alpha-motoneurons were studied in the light and electron microscope after intracellular recording and staining with the fluorescent dye Procion Yellow. Generally, the ultrastructural preservation of the stained neurons improved when the amount of dye delivered was decreased, and when the duration of the microelectrode impalement of the neuron as well as the time between the intracellular staining and the tissue fixation was kept as short as possible. Utilizing the optimal experimental procedure finally arrived at, about one-third of the stained neurons could be used for further quantitative morphometric analysis. With respect to synaptology and gross architecture these cells appeared to differ from control motoneurons mainly with regard to a focal disarrangement of the cell body periphery, probably a result of the microelectrode injury, and a certain degree of damage to some large boutons.

Animals↗

Nitric oxide release during evoked neuronal activity in cerebellum slices: detection with platinized carbon-fiber microelectrodes.

Nitric oxide is an important biological messenger that particularly induces the relaxation of smooth muscle cells surrounding vessels, and, hence, controls the flow of blood. This mechanism is essential for brain function, and its fine control, termed functional hyperemia, is supposed to be realized by certain neurons that may release bursts of NO*. The aim of the present study is to examine the advantages of platinized carbon-fiber microelectrodes (5-7 microm tip diameter) for the direct and in situ electrochemical detection of NO* released by neurons into ex vivo cerebellum slices. After establishing the different analytical properties of the platinized carbon-fiber microelectrodes in vitro on NO* solutions at 50 nM to 1 mM concentration, they were characterized using DEA-NONOate solutions that chemically decompose into NO*, and therefore mimic the measurement of transient variations of NO* concentration in biological samples. This validated the present approach, so that direct, in situ ex vivo measurements of nitric oxide released by neurons in a rat cerebellar slice are presented and discussed.

Animals↗

Methodological aspects of microelectrode measurements in cellular spheroids.

Different types of oxygen microelectrodes have been tested in measurements on cellular spheroids. The shape of the oxygen gradients varied strongly depending on size and type of the spheroids. No significant differences in the results were obtained when different types of electrodes were applied. All measurements were made in a perfusion chamber. The shape of the gradients did not vary with time in the perfusion chamber. The reproducibility was found good in repeated measurements using the same spheroid. No mechanical or chemical disturbances were seen during the penetration of the spheroids. Changes in the medium flow rate through the chamber did not drastically change the shape of the oxygen gradients. Almost no convection could be seen at the bottom of the chamber close to the spheroids. The composition of the medium was found to be of importance. Lock's solution containing glucose was found to be satisfactory. The potential signals in the double barrel electrodes allowed an accurate determination of the position when the electrode hit the spheroid surface. The information gained from microelectrode measurements in spheroids might be valuable for the understanding of effects of new tumor treatment modalities in which hypoxic cell sensitizers or high LET radiation are utilized.

Animals↗

Microelectrode monitoring of cortical and subcortical structures during stereotactic surgery.

We describe microelectrode recording and stimulation techniques to delineate the cellular boundaries and neural projections of stereotactic brain targets. These techniques have applications in the surgery for pain, movement disorders and in psychosurgery. Neuronal records from stereotactic operations including thalamotomy, pallidotomy, cingulotomy and anterior capsulotomy are discussed. These tools are used to distinguish gray matter from white matter, to obtain direct measures of cellular activity in the target, to identify the physiological properties and receptive fields of the subpopulation of neurons at the electrode tip and to avoid lesion making induced injury to adjacent structures. Microelectrode recording and stimulation techniques improve physiological localization and decrease the possibility of unwanted neurological complications with functional stereotactic procedures.

Brain↗

Single-microelectrode voltage clamp measurements of pancreatic beta-cell membrane ionic currents in situ.

A conventional patch clamp amplifier was used to test the feasibility of measuring whole-cell ionic currents under voltage clamp conditions from beta-cells in intact mouse islets of Langerhans perifused with bicarbonate Krebs buffer at 37 degrees C. Cells impaled with a high resistance microelectrode (ca. 0.150 G omega) were identified as beta-cells by the characteristic burst pattern of electrical activity induced by 11 mM glucose. Voltage-dependent outward K+ currents were enhanced by glucose both in the presence and absence of physiological bicarbonate buffer and also by bicarbonate regardless of the presence or absence of glucose. For comparison with the usual patch clamp protocol, similar measurements were made from single rat beta-cells at room temperature; glucose did not enhance the outward currents in these cells. Voltage-dependent inward currents were recorded in the presence of tetraethylammonium (TEA), an effective blocker of the K+ channels known to be present in the beta-cell membrane. Inward currents exhibited a fast component with activation-inactivation kinetics and a delayed component with a rather slow inactivation; inward currents were dependent on Ca2+ in the extracellular solution. These results suggest the presence of either two types of voltage-gated Ca2+ channels or a single type with fast and slow inactivation. We conclude that it is feasible to use a single intracellular microelectrode to measure voltage-gated membrane currents in the beta-cell within the intact islet at 37 degrees C, under conditions that support normal glucose-induced insulin secretion and that glucose enhances an as yet unidentified voltage-dependent outward K+ current.

Animals↗

Microelectrode studies of toad urinary bladder epithelial cells using a novel mounting method.

To optimise the conditions for recording stable membrane potentials, epithelial cells of short-circuited toad bladders were impaled via either their apical or basolateral membranes. Microelectrode impalements via the apical membrane were affected by impalement damage and were typically biphasic, consisting of an initial sharp increase in apical membrane potential (Vsc of around -26 mV), followed by a rapid depolarization of Vsc towards 0 mV in the next 10-20 s. To facilitate basolateral impalement two different methods for mounting bladders were tested. Both mounting methods yielded similar values for Vsc and Ra/Rb (the ratio of apical to basolateral membrane resistance) of around -57 mV and 5, respectively, which were larger than those recorded via the apical membrane and consistent with potential measurements from other tight epithelial tissues. Of the two basolateral mounting methods tested, the agar method gave the most stable impalements, making it possible to use amiloride and Ba2+ to assess for impalement damage. In conclusion, basolateral impalements of agar-mounted toad bladders makes this traditionally difficult tissue amenable to microelectrode studies.

Animals↗

Novel magnesium ion-selective microelectrodes based on a neutral carrier.

Two types of Mg(2+)-selective microelectrodes based on a synthetic neutral carrier and containing poly-(vinyl chloride) (PVC) are described. The first is applicable to intracellular Mg2+ assays and suffers no interference from alkali and all other alkaline-earth metal cations. The second can be used for determining intra- as well as extracellular Mg2+ activities, but Ca2+ and especially lipophilic cations (e.g. acetylcholine) may interfere. Cyclohexanone is used for dissolving the PVC-containing membrane phases thus avoiding problems encountered with the much more volatile tetrahydrofuran. The procedure gives a higher output of working microelectrodes and can also be applied with other membrane phases.

Calcium↗