PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Microfluidics”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14Linked to original sources

Imaging of peptide adsorption to microfluidic channels in a plastic compact disc using a positron emitting radionuclide.

A method for studying peptide-surface interactions within microfluidic channels by radionuclide imaging is described. With the high surface area-to-volume ratio of channels in miniaturised devices, combined with low amounts of analyte, non-specific peptide adsorption is a critical issue. The objective of the study was therefore to develop a method capable of direct detection of adsorbed peptide within microfluidic channels. A micro-device consisting of channels moulded in a plastic compact disc was chosen for the study, together with two selected peptides of different lengths and isoelectric point (pI) values. A bifunctional chelator, DOTA, was attached to the peptide by conjugation and labelled with the short-lived positron emitting radionuclide 68Ga. Quantitative images of radiotracer distribution within the microfluidic channels were obtained using a PhosphorImager system. The power of the method was demonstrated by the ability to clearly measure changes in adsorption when varying a number of parameters that typically affect peptide adsorption. These included surface modifications, analyte concentration, pH, and ionic strength. Additionally, two quantification methods were developed and compared. Radionuclide imaging also permitted visualisation of adsorption and release processes in microchannel chromatographic columns. The results suggest that radionuclide imaging is a suitable tool not only for the study of peptide adsorption to the microchannels presented in this study but also as a versatile tool to measure peptide-surface interactions in a wide variety of miniaturised structures and devices.

Adsorption↗

Surfactant-enhanced liquid-liquid extraction in microfluidic channels with inline electric-field enhanced coalescence.

Continuous microfluidic liquid-liquid extraction is realized in a microfluidic device by generating emulsions with large interfacial areas for mass transfer, and subsequently breaking these emulsions using electric fields into easily separated segments of immiscible liquids (plugs). The microfluidic device employs insulated electrodes in a potassium hydroxide-etched channel to create large electric fields (100 kV m(-1)) that drive coalescence of the emulsion phase. The result is a transition from disperse to slug flow that can then readily be separated by gravity. Extractions of phenol and p-nitrophenol from an aqueous to hexane-surfactant solution serve as model systems. In addition to the increased surface area in the emulsion, extraction efficiency is enhanced by reverse micelles resulting from the presence of surfactants. The surfactant concentration is varied approximately 1-10 wt% and a general two-parameter model is developed to quantify the extraction behavior and demonstrate the effectiveness of reverse micelle enhanced extraction.

Micelles↗

Improving agglutination tests by working in microfluidic channels.

Latex agglutination tests are used for the diagnosis of diseases in man and animals. They are generally simple, cheap, and do not require sophisticated equipment, nor highly specialized skills. In this Technical Note, we put latex agglutination tests in a microfluidic format. The experiment is performed in PDMS (polydimethylsiloxane) microchannels, using streptavidin-coated superparamagnetic beads and a magnetic field. The target molecule is biotinylated protein A. By taking full advantage of the microfluidic conditions (scaling down of the detection volume and controlled action of the shear flow), we achieved an analytical sensitivity of 10 fmol l(-1)(several hundreds of fg ml(-1)) and a fast response (a few minutes) ; the test is also quantitative. Performances of agglutination tests can thus be improved by orders of magnitude by adapting them to a microfluidic format; this comes in addition to the usual advantages offered by this technology (integration, high throughput etc.).

Agglutination Tests↗

Development of a microfluidic biosensor module for pathogen detection.

The development of a microfluidic biosensor module with fluorescence detection for the identification of pathogenic organisms and viruses is presented in this article. The microfluidic biosensor consists of a network of microchannels fabricated in polydimethylsiloxane (PDMS) substrate. The microchannels are sealed with a glass substrate and packed in a Plexiglas housing to provide connection to the macro-world and ensure leakage-free flow operation. Reversible sealing permits easy disassembly for cleaning and replacing the microfluidic channels. The fluidic flow is generated by an applied positive pressure gradient, and the module can be operated under continuous solution flow of up to 80 microL min(-1). The biosensor recognition principle is based on DNA/RNA hybridization and liposome signal amplification. Superparamagnetic beads are incorporated into the system as a mobile solid support and are an essential part of the analysis scheme. In this study, the design, fabrication and the optimization of concentrations and amounts of the different biosensor components are carried out. The total time required for an assay is only 15 min including sample incubation time. The biosensor module is designed so that it can be easily integrated with a micro total analysis system, which will combine sample preparation and detection steps onto a single chip.

Bacteria↗

Facile fabrication of microfluidic systems using electron beam lithography.

We present two fast and generic methods for the fabrication of polymeric microfluidic systems using electron beam lithography: one that employs spatially varying electron-beam energy to expose to different depths a negative electron-beam resist, and another that employs a spatially varying electron-beam dose to differentially expose a bi-layer resist structure. Using these methods, we demonstrate the fabrication of various microfluidic unit structures such as microchannels of a range of geometries and also other more complex structures such as a synthetic gel and a chaotic mixer. These are made without using any separate bonding or sacrificial layer patterning and etching steps. The schemes are inherently simple and scalable, afford high resolution without compromising on speed and allow post CMOS fabrication of microfluidics. We expect them to prove very useful for the rapid prototyping of complete integrated micro/nanofluidic systems with sense and control electronics fabricated by upstream processes.

Electrons↗

Characterization of a microfluidic dispensing system for localised stimulation of cellular networks.

We present a 3-D microfluidic device designed for localized drug delivery to cellular networks. The device features a flow cell comprising a main channel for nutrient delivery as well as multiple channels for drug delivery. This device is one key component of a larger, fully integrated system now under development, based upon a microelectrode array (MEA) with on-chip CMOS circuitry for recording and stimulation of electrogenic cells (e.g. neurons, cardiomyocytes). As a critical system unit, the microfluidics must be carefully designed and characterized to ensure that candidate drugs are delivered to specific regions of the culture at known concentrations. Furthermore, microfluidic design and functionality is dictated by the size, geometry, and material/electrical characteristics of the CMOS MEA. Therefore, this paper reports on the design considerations and fabrication of the flow cell, including theoretical and experimental analysis of the mass transfer properties of the nutrient and drug flows, which are in good agreement with one another. To demonstrate proof of concept, the flow cell was mounted on a dummy CMOS chip, which had been plated with HL-1 cardiomyocytes. A test chemical compound was delivered to the cell culture in a spatially resolved manner. Envisioned applications of this stand-alone system include simultaneous toxicological testing of multiple compounds and chemical stimulation of natural neural networks for neuroscience investigations.

Algorithms↗

Microfluidic sorting system based on optical waveguide integration and diode laser bar trapping.

Effective methods for manipulating, isolating and sorting cells and particles are essential for the development of microfluidic-based life science research and diagnostic platforms. We demonstrate an integrated optical platform for cell and particle sorting in microfluidic structures. Fluorescent-dyed particles are excited using an integrated optical waveguide network within micro-channels. A diode-bar optical trapping scheme guides the particles across the waveguide/micro-channel structures and selectively sorts particles based upon their fluorescent signature. This integrated detection and separation approach streamlines microfluidic cell sorting and minimizes the optical and feedback complexity commonly associated with extant platforms.

Cell Culture Techniques↗

Soft lithographic patterning of supported lipid bilayers onto a surface and inside microfluidic channels.

We present simple soft lithographic methods for patterning supported lipid bilayer (SLB) membranes onto a surface and inside microfluidic channels. Micropatterns of polyethylene glycol (PEG)-based polymers were fabricated on glass substrates by microcontact printing or capillary moulding. The patterned PEG surfaces have shown 97 +/- 0.5% reduction in lipid adsorption onto two dimensional surfaces and 95 +/- 1.2% reduction inside microfluidic channels in comparison to glass control. Atomic force microscopy measurements indicated that the deposition of lipid vesicles led to the formation of SLB membranes by vesicle fusion due to hydrophilic interactions with the exposed substrate. Furthermore, the functionality of the patterned SLBs was tested by measuring the binding interactions between biotin (ligand)-labeled lipid bilayer and streptavidin (receptor). SLB arrays were fabricated with spatial resolution down to approximately 500 nm on flat substrate and approximately 1 microm inside microfluidic channels, respectively.

Dimethylpolysiloxanes↗

A passive microfluidic hydrogen-air fuel cell with exceptional stability and high performance.

We describe an advanced microfluidic hydrogen-air fuel cell (FC) that exhibits exceptional durability and high performance, most notably yielding stable output power (>100 days) without the use of an anode-cathode separator membrane. This FC embraces an entirely passive device architecture and, unlike conventional microfluidic designs that exploit laminar hydrodynamics, no external pumps are used to sustain or localize the reagent flow fields. The devices incorporate high surface area/porous metal and metal alloy electrodes that are embedded and fully immersed in liquid electrolyte confined in the channels of a poly(dimethylsiloxane) (PDMS)-based microfluidic network. The polymeric network also serves as a self-supporting membrane through which oxygen and hydrogen are supplied to the cathode and alloy anode, respectively, by permeation. The operational stability of the device and its performance is strongly dependent on the nature of the electrolyte used (5 M H2SO4 or 2.5 M NaOH) and composition of the anode material. The latter choice is optimized to decrease the sensitivity of the system to oxygen cross-over while still maintaining high activity towards the hydrogen oxidation reaction (HOR). Three types of high surface area anodes were tested in this work. These include: high-surface area electrodeposited Pt (Pt); high-surface area electrodeposited Pd (Pd); and thin palladium adlayers supported on a "porous" Pt electrode (Pd/Pt). The FCs display their best performance in 5 M H2SO4 using the Pd/Pt anode. This exceptional stability and performance was ascribed to several factors, namely: the high permeabilities of O2, H2, and CO2 in PDMS; the inhibition of the formation of insoluble carbonate species due to the presence of a highly acidic electrolyte; and the selectivity of the Pd/Pt anode toward the HOR. The stability of the device for long-term operation was modeled using a stack of three FCs as a power supply for a portable display that otherwise uses a 3 V battery.

Air↗

A microfluidic flow distributor generating stepwise concentrations for high-throughput biochemical processing.

In this paper, we describe a microfluidic device in which solutions with stepwise concentrations can be accurately generated by continuously introducing two kinds of miscible liquids from each inlet, and biochemical processing can be conducted at the various conditions. Introduced liquid flows are geometrically divided into a number of downstream flows through multiple distribution channels, and each divided flow is then mixed with the divided flow of another liquid at a confluent point. The lengths of the precisely designed distribution channels determine the mixing ratio of the two liquids, without the influence of flow rate. In this study, a PDMS microfluidic device able to generate nine different concentrations was fabricated, and the performance of this device was estimated via colorimetric assay. As a biological application of this device, cell cultivation was performed under different concentration conditions. Due to its simplicity of operation, this microfluidic flow distributor will be applied to various kinds of biological analysis and screening systems.

Alginates↗

Dose-dependent cell-based assays in V-shaped microfluidic channels.

The capability of lab-on-a-chip technologies in controlling cell transportation, generating concentration gradients, and monitoring cellular responses offers an opportunity to integrate dose-dependent cell-based bioassays on a chip. In this study, we have developed microfluidic modules featured with channel components and sandbag structures for positioning biological cells within the microchip. We have demonstrated that by geometric modulation of the microchannel architectures, it is possible to immobilize individual cells at desired locations with controllable numbers, to generate defined concentration gradients at various channel lengths, and to improve the efficiency and reproducibility in data acquisition. The microfluidic module was used to exercise a series of cell-based assays, including the measurement of kinetics and dynamics of intracellular enzymatic activities, the analysis of cellular response under the stimulation of two chemicals with defined concentration profiles, and the study of laser irradiation effect on cellular uptake of photosensitizers. The results demonstrated the capabilities of the microfluidic module for simultaneously conducting multiple sets of dose-dependent, cell-based bioassays, and for quantitatively comparing responses of individual cells under various stimulations.

Biological Assay↗

Chitosan-mediated in situ biomolecule assembly in completely packaged microfluidic devices.

We report facile in situ biomolecule assembly at readily addressable sites in microfluidic channels after complete fabrication and packaging of the microfluidic device. Aminopolysaccharide chitosan's pH responsive and chemically reactive properties allow electric signal-guided biomolecule assembly onto conductive inorganic surfaces from the aqueous environment, preserving the activity of the biomolecules. A transparent and nonpermanently packaged device allows consistently leak-free sealing, simple in situ and ex situ examination of the assembly procedures, fluidic input/outputs for transport of aqueous solutions, and electrical ports to guide the assembly onto the patterned gold electrode sites within the channel. Both in situ fluorescence and ex situ profilometer results confirm chitosan-mediated in situ biomolecule assembly, demonstrating a simple approach to direct the assembly of biological components into a completely fabricated device. We believe that this strategy holds significant potential as a simple and generic biomolecule assembly approach for future applications in complex biomolecular or biosensing analyses as well as in sophisticated microfluidic networks as anticipated for future lab-on-a-chip devices.

Biosensing Techniques↗

Injection molded microfluidic chips featuring integrated interconnects.

An injection molding process for the fabrication of disposable plastic microfluidic chips with a cycle time of 2 min has been designed, developed, and implemented. Of the sixteen commercially available grades of cyclo-olefin copolymer (COC) that were screened for autofluorescence and transparency to ultraviolet (UV) light, Topas 8007 x 10 was identified as the most suitable for production. A robust solid metal mold insert defining the microfluidic channels was rapidly microfabricated using a process that significantly reduces the time required for electroplating. No wear of the insert was observed even after over 1000 cycles. The chips were bonded by thermal fusion using different bonding conditions. Each condition was tested and its suitability evaluated by burst pressure measurements. The COC microfluidic chips feature novel, integrated, reversible, standardized, ready-to-use interconnects that enable operation at pressures up to 15.6 MPa, the highest value reported to date. The suitability of these UV transparent, high pressure-resistant, disposable devices was demonstrated by in situ preparation of a high surface area porous polymer monolith within the channels.

Microfluidic Analytical Techniques↗

High-speed fabrication of patterned colloidal photonic structures in centrifugal microfluidic chips.

In this paper, we report a rapid and facile method for fabricating colloidal photonic crystals inside microchannels of radially symmetric microfluidic chips which were made using soft-lithography. As the suspension of monodisperse silica or polystyrene latex spheres was driven to flow through the channels under the action of centrifugal force, the colloidal spheres were quickly assembled into face centered cubic arrangement which had a few photonic stop bands. The soft-microfluidic channels and cells confined the colloidal crystals into designed patterns. The optical reflectance was modulated by the refractive-index mismatch between the colloidal particles and the solvent in the interstices between the particles. Therefore, the present microfluidic chips with built-in colloidal photonic crystals can be used as in-situ optofluidic microsensors for high throughput screening or light filters in integrated adaptive optical devices.

Colloids↗

T cell chemotaxis in a simple microfluidic device.

This paper describes the use of a simple microfluidic device for studying T cell chemotaxis. The microfluidic device is fabricated in poly(dimethylsiloxane) (PDMS) using soft-lithography and consists of a "Y" type fluidic channel. Solutions are infused into the device by syringe pumps and generate a concentration gradient in the channel by diffusion. We show that the experimentally measured gradient profiles agree nicely with theoretical predictions and the gradient is stable in the observation region for cell migration. Using this device, we demonstrate robust chemotaxis of human T cells in response to single and competing gradients of chemokine CCL19 and CXCL12. Because of the simplicity of the device, it can flexibly control gradient generation in space and time, and would allow generation of multiple gradient conditions in a single chip for highly parallel chemotaxis experimentation. Visualization of T cell chemotaxis has previously been limited to studies in 3D matrices or under agarose assays, which do not allow precise control or variation in conditions. Acknowledging the importance of lymphocyte homing in the adaptive immune response, the ability to study T cell chemotaxis in microfluidic devices offers a new approach for investigating lymphocyte migration and chemotaxis in vitro.

Cells, Cultured↗

Integrated thin-film polymer/fullerene photodetectors for on-chip microfluidic chemiluminescence detection.

We report the use of solution-processed thin-film organic photodiodes for microscale chemiluminescence. The active layer of the photodiodes comprised a 1 : 1 blend by weight of the conjugated polymer poly(3-hexylthiophene) [P3HT] and [6,6]-phenyl-C(61)-butyric acid-methylester [PCBM]--a soluble derivative of C(60). The devices had an active area of 1 mm x 1 mm, and a broad-band response from 350 to 700 nm, with an external quantum efficiency of more than 50% between 450 and 550 nm. The photodiodes have a simple layered structure that permits facile integration with planar chip-based systems. To evaluate the suitability of the organic devices as integrated detectors for microscale chemiluminescence, a peroxyoxalate based chemiluminescence reaction (PO-CL) was monitored within a poly(dimethyl-siloxane) (PDMS) microfluidic device. Quantitation of hydrogen peroxide indicated excellent linearity and yielded a detection limit of 10 microM, comparable with previously reported results using micromachined silicon microfluidic chips with integrated silicon photodiodes. The combination of organic photodiodes with PDMS microfluidic chips offers a means of creating compact, sensitive and potentially low-cost microscale CL devices with wide-ranging applications in chemical and biological analysis and clinical diagnostics.

Dimethylpolysiloxanes↗

A fully integrated microfluidic genetic analysis system with sample-in-answer-out capability.

We describe a microfluidic genetic analysis system that represents a previously undescribed integrated microfluidic device capable of accepting whole blood as a crude biological sample with the endpoint generation of a genetic profile. Upon loading the sample, the glass microfluidic genetic analysis system device carries out on-chip DNA purification and PCR-based amplification, followed by separation and detection in a manner that allows for microliter samples to be screened for infectious pathogens with sample-in-answer-out results in < 30 min. A single syringe pump delivers sample/reagents to the chip for nucleic acid purification from a biological sample. Elastomeric membrane valving isolates each distinct functional region of the device and, together with resistive flow, directs purified DNA and PCR reagents from the extraction domain into a 550-nl chamber for rapid target sequence PCR amplification. Repeated pressure-based injections of nanoliter aliquots of amplicon (along with the DNA sizing standard) allow electrophoretic separation and detection to provide DNA fragment size information. The presence of Bacillus anthracis (anthrax) in 750 nl of whole blood from living asymptomatic infected mice and of Bordetella pertussis in 1 microl of nasal aspirate from a patient suspected of having whooping cough are confirmed by the resultant genetic profile.

DNA↗

Comparison of on-chip and off-chip microfluidic kinase assay formats.

Kinases represent an important class of targets for pharmaceutical drug development. Microfluidic devices capable of running kinase assays with either an on-chip or an off-chip enzymatic reaction have been developed. For the on-chip assay, reagent addition, mixing, enzymatic reaction, and electrophoretic separation and detection of substrate and product all take place in the channels of the microfluidic chip. For the off-chip assay, the reaction takes place in a microtiter plate, whereas the electrophoretic separation and detection of substrate and product take place in the channels of the chip. To probe differences between the on-chip and off-chip assays, a panel of commercially available kinase inhibitors was assayed at 10 microM against cyclic AMP-dependent protein kinase A, glycogen synthase kinase 3beta, mitogen- and stress-activated protein kinase, and Akt1 using both the off-chip and on-chip assays. Good correlation was observed between inhibition measured by the two methods, with most of the differences in measured inhibition being attributed to compound solubility and enzyme concentration effects. Microfluidic devices represent an attractive platform for kinase assays due to high data quality and the possibility of on-chip assay integration, leading to reagent and labor savings.

Microfluidics↗