PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Solid Phase Microextraction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14Linked to original sources

Theoretical considerations on the use of solid-phase microextraction with complex environmental samples.

The equations governing the use of equilibrium solid-phase microextraction (SPME) for environmental samples with complex heterogeneous matrices were derived in terms of parameters commonly measured or estimated by environmental scientists. Parameterization of the SPME equations allowed for the a priori prediction of SPME performance as a function of analyte and sample properties as well as experimental conditions. A theoretical evaluation of SPME was performed for a broad range of realistic scenarios using calculated equilibrium partitioning parameters and the implications for practical applications were discussed. Potential pitfalls and errors in quantitative measurements were identified, and different approaches to SPME calibration were presented. The concept of an optimum minimum volume for the analysis of heterogeneous environmental samples was presented and fully developed. Data from three previous studies were used to validate the correctness of our theoretical framework; the agreement between the measured relative recoveries of a variety of hydrophobic organic chemicals and theoretical predictions was reasonable. The results of this study highlight the potential for SPME to be a valuable technique for the measurement of hydrophobic organic contaminants in complex environmental samples. The SPME technique appears to be especially well suited for samples with high solids-to-water ratios and/or large sample volumes. Examples of such applications include sediment interstitial water and in situ field measurements, respectively.

Calibration↗

Sample preparation with fiber-in-tube solid-phase microextraction for capillary electrophoretic separation of tricyclic antidepressant drugs in human urine.

Solid-phase microextraction (SPME) is a solvent-free sample preparation technique using a thin coating attached to the surface of a fused silica-fiber as the extraction medium, which has been successfully applied to the analysis of a wide variety of compounds by coupling to gas chromatography (GC). In recent years, in-tube SPME using GC capillary column as the extraction medium has also been developed and coupled with liquid chromatography (LC) for the preconcentration of nonvolatile compounds. In this study, an on-line interface between the fiber-in-tube SPME and capillary electrophoresis (CE) has been developed, and the preconcentration and separation of four tricyclic antidepressant (TCA) drugs, amitriptyline, imipramine, nortriptyline, and desipramine, were performed with the hyphenated system. Under the optimized condition, a better extraction performance than conventional in-tube SPME was obtained, even the length of the extraction medium was much shorter. The results clearly indicated that the fiber was working effectively as an extraction medium. For the separation of these four TCAs, capillary electrophoretic separation with beta-cyclodextrin as the buffer additive has been employed and the application of the developed system to the analysis of complex sample mixtures in a biological matrix is also demonstrated.

Amitriptyline↗

Single step determination of fragrances in Cucurbita flowers by coupling headspace solid-phase microextraction low-pressure gas chromatography-tandem mass spectrometry.

Coupling headspace solid-phase microextraction (HS-SPME) and low-pressure gas chromatography-tandem mass spectrometry (LP-GC-MS-MS) has been used for determining 20 volatile compounds present in flowers. HS-SPME coupled with LP-GC-MS-MS acts in a synergic way allowing a fast extraction and analysis of the target compounds. The method has been optimised studying the influence of the adsorption temperature and adsorption time. The best results were obtained heating the SPME vials at 60 degrees C for 5 min using 65 microm poly(dimethylsiloxane-divinylbenzene) fibers. The validation of the method ensures the fitness for the purpose of the analytical method, achieving appropriate lower limits, recoveries and precision. The analytical method has been applied to the characterisation of zucchini flowers fragrances in air using passive sampling, in order to improve our knowledge on zucchini fragrances and to better pollination technique in future steps.

Cucurbita↗

Multivariate optimization of a solid-phase microextraction method for the analysis of phthalate esters in environmental waters.

A solid-phase microextraction method (SPME) coupled to gas chromatography-mass spectrometry (GC-MS) has been developed for the determination of the six phthalate esters included in the US Environmental Protection Agency (EPA) Priority Pollutants list in water samples. These compounds are dimethyl phthalate (DMP), diethyl phthalate (DEP), di-n-butyl phthalate (DBP), butylbenzyl phthalate (BBP), di-2-ethylhexyl phthalate (DEHP) and di-n-octyl phthalate (DOP). Detailed discussion of the different parameters, which could affect the extraction process, is presented. Main factors have been studied and optimized by means of a multifactor categorical design. Different commercial fibers, polydimethylsiloxane (PDMS), polydimethylsiloxane-divinylbenzene (PDMS-DVB), polyacrylate (PA), Carboxen-polydimethylsiloxane (CAR-PDMS) and Carbowax-divinylbenzene (CW-DVB), have been investigated, as well as the extraction mode, exposing the fiber directly into the sample (DSPME) or into the headspace over the sample (HS-SPME), and different extraction temperatures. The use of this experimental design allowed for the evaluation of interactions between factors. Extraction kinetics has also been studied. The optimized microextraction method showed linear response and good precision for all target analytes. Detection limits were estimated considering the contamination problems associated to phthalate analysis. They were in the low pg mL(-1), excluding DEHP (100 pg mL(-1)). The applicability of the developed SPME method was demonstrated for several real water samples including mineral, river, industrial port and sewage water samples. All the target analytes were found in real samples. Levels of DEP and DEHP were over 1 ng mL(-1) in some of the samples.

Chemical Fractionation↗

Monoterpene and sesquiterpene hydrocarbons of virgin olive oil by headspace solid-phase microextraction coupled to gas chromatography/mass spectrometry.

In the present article, a headspace solid-phase microextraction method coupled to GC/MS was developed and applied for the simultaneous determination of mono- and sesquiterpenic hydrocarbons in virgin olive oils of different olive variety and geographical origin. Analysis of various oils resulted in the simultaneous detection of 15 monoterpenes and 30 sesquiterpenes. Some of these hydrocarbons were previously reported to be constituents of virgin olive oil terpenoid fraction, although we also detected some terpenic hydrocarbons that have not previously been documented as present in virgin olive oil. Significant differences were detected in the proportion of terpenic compounds in oils obtained from different olive varieties grown in different geographical areas. The monoterpene, and particularly the sesquiterpene composition of olive oil may be used to distinguish samples from different cultivar and geographical areas.

Gas Chromatography-Mass Spectrometry↗

Investigation of volatile biomarkers in lung cancer blood using solid-phase microextraction and capillary gas chromatography-mass spectrometry.

In the present work, solid-phase microextraction (SPME) and gas chromatography-mass spectrometry (GC-MS) was developed for investigation of lung cancer volatile biomarkers. Headspace SPME conditions (fiber coating, extraction temperature and extraction time) and desorption conditions were optimized and applied to determination of volatiles in human blood. To find the biomarkers of lung cancer, investigation of volatile compounds in lung cancer blood and control was performed by using the present method. Concentrations of hexanal and heptanal in lung cancer blood were found to be much higher than those in control blood. The two molecules of hexanal and heptanal were regarded as biomarkers of lung cancer. By comparison of volatiles in breath and in blood, it is demonstrated that hexanal and heptanal in breath were originated from blood and screening of lung cancer by breath analysis be feasible. These results show that SPME/GC-MS is a simple, rapid and sensitive method very suitable for investigation of volatile disease markers in human blood.

Adult↗

Optimization of headspace solid-phase microextraction conditions for the determination of organophosphorus insecticides in natural waters.

Headspace solid-phase microextraction (HS-SPME) has been developed for the analysis of seven organophosphorus insecticides, i.e. diazinon, fenitrothion, fenthion, ethyl parathion, methyl bromophos, ethyl bromophos and ethion in natural waters. Their determination was carried out using gas chromatography with flame thermionic and mass spectrometric detection. To perform the HS-SPME, two types of fibre have been assayed and compared: polyacrylate (PA 85 microm), and polydimethylsiloxane (PDMS 100 microm). The main parameters affecting the HS-SPME process such as temperature, salt additives, memory effect, stirring rate and adsorption-time profile were studied. The method was developed using spiked natural waters such as ground, sea, river and lake water in a concentration range of 0.05-1 microg/l. The HS-SPME conditions were optimized in order to obtain the maximum sensitivity. Detection limits varied from 0.01 to 0.04 microg/l and relative standard deviations (RSD <17%) were obtained showing that the precision of the method is reliable. The method showed also good linearity for the tested concentration range with regression coefficients ranging between 0.985 and 0.999. Recoveries were in relatively high levels for all the analytes and ranged from 80 to 120%. Water samples collected from different stations along the flow of Kalamas river (NW Greece) were analyzed using the optimized conditions in order to evaluate the potential of the proposed method to the trace-level screening determination of organophosphorus insecticides. The analysis with HS-SPME has less background interference and the advantage of its non-destructive nature reveal the possibility of the repetitive use of the SPME fibre.

Gas Chromatography-Mass Spectrometry↗

Optimization of the headspace solid-phase microextraction for determination of glycol ethers by orthogonal array designs.

A headspace solid-phase microextraction (HS-SPME), in conjunction with gas chromatography-flame ionization detection for use in the determination of six frequently used glycol ethers at the microg/l level is described. A 75 microm Carboxenpolydimethylsiloxane fiber was used to extract the analytes from an aqueous solution. Experimental HS-SPME parameters such as extraction temperature, extraction time, salt concentration and sample volume, were investigated and optimized by orthogonal array experimental designs. The relative standard deviations for the reproducibility of the optimized HS-SPME method varied from 1.48 to 7.59%. The correlation coefficients of the calibration curves exceeded 0.998 in the microg/l range of concentration with at least two orders of magnitude. The method detection limits for glycol ethers in deionized water were in the range of 0.26 to 3.42 microg/l. The optimized method was also applied to the analysis of glycol ethers in urine and blood samples with the method detection limits ranged from 1.74 to 23.2 microg/l.

Chromatography, Gas↗

Analysis of volatiles of malt whisky by solid-phase microextraction and stir bar sorptive extraction.

Blended Scotch whisky was analysed by solid-phase microextraction (SPME) and stir bar sorptive extraction (SBSE) to study the composition of the volatiles. For SPME analysis, three different fibres were compared, poly(dimethylsiloxane) (PDMS) (100 microm). poly(acrylate) (PA) (85 microm) and divinylbenzene-Carboxen on poly(dimethylsiloxane) (DVB-CAR-(PDMS) (50/30 microm). It was found that the PDMS and DVB-CAR-PDMS fibres showed a higher enrichment capacity than PA as well as a better reproducibility. The influence of sampling time, temperature and salt addition on the enrichment of volatiles as well as the difference between liquid and headspace SPME were studied. An optimum SPME method was developed. Finally a more recent sample preparation technique, namely SBSE was evaluated to extract whisky volatiles.

Alcoholic Beverages↗

Solid-phase microextraction for herbicide determination in environmental samples.

Liquid-liquid extraction or solid-phase extraction followed by gas chromatography (GC) or high-performance liquid chromatography are traditional herbicide residue determination methods for environmental samples. Solid-phase microextraction (SPME) is a solventless, fast, and sensitive alternative herbicide residue extraction method that can be applied to numerous environmental matrices. The objective of this paper was to review SPME literature regarding extraction theory, extraction modes, fiber types, and method optimization in conjunction with present and future SPME applications for herbicide determination in environmental samples.

Chromatography, Gas↗

Solid-phase microextraction of volatile compounds in "Terrincho" ewe cheese. Comparison of different fibers.

Solid-phase microextraction coupled to gas chromatography-mass spectrometry (GC-MS) was applied to study the volatile compounds in "Terrincho" ewe cheese. Six types of fibers were tested and the main extraction parameters were studied. Carboxen-polydimethylsiloxane fiber 75 microm (CAR-PDMS) achieved the most complete profile of ewe cheese volatile compounds. The optimised conditions used for characterization of "Terrincho" ewe cheese were: sample vial equilibration at 20 degrees C for 20 min, followed by CAR-PDMS fiber exposure to the headspace above the sample for 30 min and finally thermal desorption of the adsorbed substances, in the injector port for GC-MS analysis. This technique was a useful tool for the differentiation of 11 "Terrincho" ewe cheeses, all taken from the same cheesemaking season with 30 days of ripening but from three different farmhouses, according to their volatile fraction. Results obtained were statistically treated by categorical principal component analysis. Subsequently, 49.15% of the variation in data was due to the first dimension (k = 12.7) and the second dimension (k = 8.88) accounted for 34.2% of the total information. Volatile profiles among samples indicated cheese group separation according to farmhouse of production.

Animals↗

Solid-phase microextraction for the determination of iodinated trihalomethanes in drinking water.

A headspace solid-phase microextraction (HS-SPME) method has been developed for the determination of iodinated trihalomethanes (ITHMs) in treated water samples. Mixed THMs (bromochloroido-, bromodiiodo-, chlorodiiodo-, dibromoiodo- and dichloroiodo-) were previously synthesized since commercial standards are not available. HS-SPME has shorter equilibration times than direct SPME, a cleaner background and a longer fiber life. Experimental parameters such as the selection of SPME coatings, sample volume, extraction time and addition of salts were studied. The Carbowax-divinylbenzene fiber appears to be the most suitable for the determination of ITHMs. Analytical parameters such as linearity, limit of detection and precision were also evaluated. HS-SPME was compared to liquid-liquid microextraction for the analyses of spiked treated water samples, obtaining a good agreement. It is concluded that HS-SPME has a great potential for drinking water analysis.

Adsorption↗

Solid-phase microextraction coupled with atomic emission spectroscopy--rapid screening for volatile chlorinated compounds.

Solid-phase microextraction (SPME) coupled with atomic emission spectroscopy was evaluated as a rapid screening tool for volatile halogenated compounds in water samples. After extraction, the SPME fiber was introduced to the injector where the analytes were rapidly and efficiently desorbed. The analytes entered the detector over a short period of time and produced one well-defined analyte signal. Element selective responses were measured to confirm the presence and to roughly estimate the content of volatile compounds. The total time for extraction and detection was approximately 5 min, which makes this method a rapid and promising technique for determination of total amount of volatile halogenated compounds. The proposed technique may prove useful as a screening test in order to pinpoint the samples that need further assessment by capillary gas chromatography.

Chemistry Techniques, Analytical↗

Analysis of volatile fatty acids in wastewater collected from a pig farm by a solid phase microextraction method.

The main purpose of this study is to develop a reliable Solid Phase Microextraction (SPME) method for monitoring the concentration of volatile fatty acid (VFA) in the wastewater collected from pig farms. Ten volatile fatty acid species were spiked in 2 ml of swine wastewater and extracted with a carbowax coated extraction fiber to evaluate the accuracy and precision of the method. The fiber was introduced into a gas chromatography system by thermal desorption and detected by a mass spectrometer detector. The estimated method detection limits ranged from 11.5 mM/L for formic acid to 0.03 mM/L for heptanoic acid. The method is more sensitive than the sample direct injection method. The percentage recovery of analytes ranged from 77.3 for propanoic acid to 114.1 for formic acid at the spike level of 19.09 mM/L. The compound absorption rate varied significantly with the fiber absorption time for n-Valeric, isocaproic, n-caproic and heptanoic acids. An SPME method with twenty minutes fiber absorption and three minutes thermal desorption was tested in this study and resulted in good reproducibility for analyzing VFAs in swine wastewater. The method may be applied for scanning a wide spectrum of polar organic compounds in environmental samples.

Acrylic Resins↗

Polypyrrole-coated capillary coupled to HPLC for in-tube solid-phase microextraction and analysis of aromatic compounds in aqueous samples.

In-tube solid-phase microextraction (SPME) based on a polypyrrole (PPY)-coated capillary was investigated for the extraction of aromatic compounds from aqueous solutions. The PPY-coated capillary was coupled on-line to HPLC that was programmed with an autosampler to achieve automated in-tube SPME and HPLC analysis. Three groups of aromatics, including both polar and nonpolar compounds, were examined. The results demonstrated that the PPY coating had a higher extraction efficiency than the currently used commercial capillary coatings, especially for polycyclic aromatic compounds and polar aromatics due to the increasing pi-pi interactions, interactions by polar functional groups, and hydrophobic interactions between the polymer and the analytes. In addition to the functional groups in the PPY coating, which contributed to the higher extraction efficiency and selectivity toward analytes, the coating's porous surface structure,which was revealed by electron microscopy experiments, provided a high surface area that allowed for high extraction efficiency. It was found that the extraction efficiency and selectivity could be tuned by changing the coating thickness. The preliminary study of the extraction mechanism indicated that analytes were extracted onto the PPY coating mainly by an adsorption mechanism. The method was used for the extraction and analysis of both polar and nonpolar aromatics in aqueous samples.

Journal Article↗

Time-weighted average sampling with solid-phase microextraction device: implications for enhanced personal exposure monitoring to airborne pollutants.

The solid-phase microextraction (SPME) device is used as a time-weighted average (TWA) sampler for gas-phase analytes by retracting the coated fiber a known distance into its needle housing during the sampling period. Unlike in conventional spot sampling with SPME, the TWA sampling approach does not allow the analytes to reach equilibrium with the fiber coating, but rather they diffuse through the opening in the needle to the location of the sorbent. The amount of analytes accumulated over time gives the measurement of the average concentration to which the device was exposed to. Depending on the sorbent used as the sink, TWA sampling for various analytes is possible with times ranging from 15 min to at least 16 h. Both the poly(dimethylsiloxane) (PDMS) and poly(dimethylsiloxane)/divinylbenzene (PDMS/DVB) fiber coating phases were tested, with the latter employing on-fiber derivatization for reactive carbonyl compounds, e.g., formaldehyde. Described herein are the theoretical and practical considerations for using the SPME device as a TWA sampler.

Air Pollutants, Occupational↗

Optimization of solid phase microextraction analysis for the headspace volatile compounds of parmesan cheese.

Optimum conditions of solid phase microextraction (SPME) analysis of the headspace volatile compounds of Parmesan cheese in airtightly sealed 100-mL bottles were developed. The coefficient of variation of SPME analysis on the headspace volatile compounds of Parmesan cheese was 2%. The reproducibility of SPME was improved by a combination of sampling at -10 degrees C, controlling the sample temperature, and uniform magnetic stirring of samples during equilibrium and isolation steps. The sensitivity of SPME increased by 125% in total peak areas by a combination of 40 min of sonication and 25% (w/v) sodium phosphate solution, compared with that of samples containing deionized water only (P < 0.05). The addition of salt solution or sonication treatment in samples increased the headspace volatile compounds of cheese quantitatively without producing any new volatile compounds.

Cheese↗

Evaluation of Solid-Phase Microextraction for Analysis of Volatile Metabolites Produced by Staphylococci.

The evaluation of solid-phase microextraction (SPME) for analysis of flavor compounds produced by bacteria has been studied. First, it was necessary to determine the optimal conditions to extract the different volatile compounds in dilute aqueous solutions. For this, the effects of salt, headspace, and liquid samplings and two coating phases [poly(dimethylsiloxane) (PDMS) and poly(acrylate) (PA)] were tested. The addition of salt enhanced SPME absorption of all the compounds. Ethyl ester was better extracted in liquid sampling with PDMS phase, whereas all of the other compounds were better extracted in headspace sampling at 80 degrees C with PA phase. The SPME technique was applied to the analysis of bacterial metabolites. It has been shown that Staphylococcus xylosus (16) and Staphylococcus carnosus (833) were able to produce esters and to catabolize leucine and that S. carnosus (833) limited the oxidation of free fatty acids.

Journal Article↗