[On the problem of the causal mechanism of the blood circulation and atmospheric pressure].
Explore the source record for details and available documents.
SEARCH · PubMed Health
Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
A miniaturized nebulizer chip for capillary liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (capillary LC-microchip APCI-MS) is presented. The APCI chip consists of two wafers, a silicon wafer and a Pyrex glass wafer. The silicon wafer has a DRIE etched through-wafer nebulizer gas inlet, an edge capillary insertion channel, a stopper, a vaporizer channel and a nozzle. The platinum heater electrode and pads for electrical connection were patterned on to the Pyrex glass wafer. The two wafers were joined by anodic bonding, creating a microchip version of an APCI-source. The sample inlet capillary from an LC column is directly connected to the vaporizer channel of the APCI chip. The etched nozzle in the microchip forms a narrow sample plume, which is ionized by an external corona needle, and the formed ions are analyzed by a mass spectrometer. The nebulizer chip enables for the first time the use of low flow rate separation techniques with APCI-MS. The performance of capillary LC-microchip APCI-MS was tested with selected neurosteroids. The capillary LC-microchip APCI-MS provides quantitative repeatability and good linearity. The limits of detection (LOD) with a signal-to-noise ratio (S/N) of 3 in MS/MS mode for the selected neurosteroids were 20-1000 fmol (10-500 nmol l(-1)). LODs (S/N = 3) with commercial macro APCI with the same compounds using the same MS were about 10 times higher. Fast heat transfer allows the use of the optimized temperature for each compound during an LC run. The microchip APCI-source provides a convenient and easy method to combine capillary LC to any API-MS equipped with an APCI source. The advantages and potentials of the microchip APCI also make it a very attractive interface in microfluidic APCI-MS.
Presented here is an approach to representing the data from atmospheric pressure chemical ionization (APCI) mass spectrometry (MS) of triacylglycerols (TAG) using a set of one, two, or three Critical Ratios. These Critical Ratios may be used directly to provide structural information concerning the regioisomeric composition of the triacylglycerols (TAG), and about the degree of unsaturation in the TAG. An AAA-type, or Type I, TAG has only one Critical Ratio, the ratio of the protonated molecule, [M + H]+, to the DAG fragment ion, [AA]+. The Critical Ratio for a Type I TAG is [MH]+/Z[DAG]+, and the mass spectrum of a Type I TAG can be reproduced from only this one ratio. An ABA/AAB/BAA, or Type II, TAG has two Critical Ratios, the [MH]+/sigma[DAG]+ ratio and the [AA]+/[AB]+ ratio. The [AA]+/[AB]+ ratio for a single TAG or TAG mixture can be compared with the [AA]+/[AB]+ ratios of pure regioisomeric standards, and the percentage of each regioisomer can be estimated. The abundance of the protonated molecule and the abundances of the two [DAG]+ fragment ions can be calculated from the two Critical Ratios for a Type II TAG. To calculate the abundances, the Critical Ratios are processed through the Bottom-Up Solution to the TAG lipidome. First, Critical Limits are calculated from the Critical Ratios, and then the Critical Ratios are classified into Cases by comparison with the Critical Limits. Once the Case classification is known, the equation for the abundance of each ion in the mass spectrum is given by the Bottom-Up Solution. A Type III TAG has three different FA and three Critical Ratios. The [MH]+/Z[DAG]+ ratio is the first Critical Ratio, the [AC]+/([AB]+ + [BC]+) ratio is the second Critical Ratio, and the [BC]+/[AB]+ ratio is the third Critical Ratio. The second critical ratio for a Type III TAG can be compared with regioisomeric standards to provide an estimate of the percentage composition of the regioisomers. The three Critical Ratios for a Type III TAG can be processed through the Bottom-Up Solution to calculate the four ion abundances that make up the APCI-MS mass spectrum. The Critical Ratios constitute a reduced data set that provides more information in fewer values than the raw abundances.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A series-coupled (tandem) ensemble of two capillary GC columns using different stationary phases and a pneumatically actuated low-volume valve connecting the column junction point to an atmospheric-pressure vent line is used to adjust the ensemble separation of selected pairs of target compounds. The valve is normally closed, and the pressure at the column junction point assumes the value that would occur in the absence of any other connections. The valve can be opened for brief periods of time, thus producing pulses of atmospheric pressure at the column junction point. If a component pair is separated by the first column but coelutes from the column ensemble, the ensemble separation can be increased if a pulse occurs when one of the components has migrated across the column junction but the second component is still on the first column. All of the mixture components that are on the same column during the time that the valve is open (pulse duration) will be shifted to either larger or smaller retention times, but the pattern of peaks (elution order) for these components from the column ensemble will be relatively unaffected by the pressure pulse. Multiple pulses can be used to enhance the separation of different component pairs, which sequentially reach the column junction point. Performance of the valve-operated system is described. Time-of-flight mass spectrometry with time-array detection is used to examine the effects of pulse duration on the separation achieved for different component pairs.
The coupling of a rotation planar preparative thin-layer chromatography system on-line with mass spectrometry is demonstrated using a simple plumbing scheme and a self-aspirating heated nebulizer probe of a corona discharge atmospheric pressure chemical ionization source. The self-aspiration of the heated nebulizer delivers approximately 20 microL/min of the 3.0 mL/min eluate stream to the mass spectrometer, eliminating the need for an external pump in the system. The viability of the coupling is demonstrated with a three-dye mixture composed of fat red 7B, solvent green 3, and solvent blue 35 separated and eluted from a silica gel-coated rotor using toluene. The real-time characterization of the dyes eluting from the rotor is illustrated in positive ion full-scan mode. Other self-aspirating ion source systems including atmospheric pressure photoionization, electrospray ionization, and inductively coupled plasma ionization, for example, might be configured and used in a similar manner coupled to the chromatograph to expand the types of analytes that could be ionized, detected, and characterized effectively.
A new atmospheric pressure (AP) infrared (IR) matrix-assisted laser desorption/ionization (MALDI) ion source was developed and interfaced with a Thermo Finnigan LCQ ion trap mass spectrometer. The source utilized a miniature all-solid-state optical parametric oscillator (OPO)-based IR laser system tunable in the lambda = 1.5-4 microm spectral range and a nitrogen ultraviolet (UV) laser (lambda = 337 nm) for use in comparative studies. The system demonstrated comparable performance at 3 microm and 337 nm wavelengths if UV matrices were used. However, AP IR-MALDI using a 3 microm wavelength showed good performance with a much broader choice of matrices including glycerol and liquid water. AP IR-MALDI mass spectra of peptides in the mass range up to 2000 Da were obtained directly from aqueous solutions at atmospheric conditions for the first time. A potential use of the new AP IR-MALDI ion source includes direct MS analysis of biological cells and tissues in a normal atmospheric environment as well as on-line coupling of mass spectrometers with liquid separation techniques.
Negative-ion atmospheric pressure chemical ionization (APCI) mass spectrometry and in-source collisionally induced dissociation (CID) were employed to obtain structural information of lutein esters from marigold extract. Both molecular ions and structurally significant fragments corresponding to the loss of fatty acids were observed in high abundance in the current study. Six lutein diesters including lauroylmyristoyl-lutein (LML), dimyristoyl-lutein (dML), myristoylpalmitoyl-lutein (MPL), dipalmitoyl-lutein (dPL), palmitoylstearoyl-lutein (PSL) and distearoyl-lutein (dSL) were characterized in a marigold flower extract. Breakdown curves (plots of relative ion abundance vs. internal energy) of three lutein diesters were established by monitoring the relative ion abundance of molecular and fragment ions at different cone voltages during negative-ion APCI-LC/MS analysis.
Explore the source record for details and available documents.
A fast quantitative high-performance liquid chromatographic separation method with atmospheric pressure chemical ionization mass spectrometric detection (HPLC-APCI-MS) was developed for the determination of low-molecular-mass aliphatic mono- and dicarboxylic acids typically present in different industrial process waters. A mixture of glycolic, lactic, a-glucoisosaccharinic, oxalic, maleic, fumaric, succinic, malic, glutaric, methylsuccinic, and adipic acids was separated using an RP chromatographic system. Adipic acid was used as an internal standard to calculate correlation coefficients for the acids studied. The chromatographic analysis of these acids was primarily carried out by means of gradient elution with an aqueous formic acid solution (0.15%, pH 2.5) and methanol using a modified C18 stationary phase. Good acid separation could be obtained for all acids by optimizing the chromatographic conditions. The method provides a simple sample preparation and faster analysis time compared to the traditional gas chromatographic methods, thus enabling almost real-time monitoring of these acids. Finally, the method developed was applied to the analysis of a complex mixture of aliphatic hydroxy carboxylic acids, which are formed as alkaline degradation products of carbohydrates during wood delignification and are present in the cooking spent liquor (black liquor).
The feasibility of ultra thin-layer chromatography atmospheric pressure matrix-assisted laser desorption ionization mass spectrometry (UTLC-AP-MALDI-MS) has been studied in the analysis of small molecules. Because of a thinner adsorbent layer, the monolithic UTLC plates provide 10-100 times better sensitivity in MALDI analysis than conventional high performance thin-layer chromatography (HPTLC) plates. The limits of detection down to a low picomole range are demonstrated by UTLC-AP-MALDI-MS. Other advantages of UTLC over HPTLC include faster separations and lower solvent consumption. The performances of AP-MALDI-MS and vacuum MALDI-MS have been compared in the analysis of small drug molecules directly from the UTLC plates. The desorption from the irregular surface of UTLC plates with an external AP-MALDI ion source combined with an ion trap instrument provides clearly less variation in measurements of m/z values when compared with a vacuum MALDI-time-of-flight (TOF) instrument. The performance of the UTLC-AP-MALDI-MS method has been applied successfully to the purity analysis of synthesis products produced by solid-phase parallel synthesis method.
A specific assay for the quantitative determination of the new antibiotic azithromycin in a low volume of human serum is described. The assay uses on-line high-performance liquid chromatography (HPLC) and atmospheric pressure chemical ionization mass spectrometry (HPLC-APCI). Deuterium-labeled azithromycin was synthesized and used as the internal standard of the assay. The drug and the internal standard are extracted from 50 microliters of serum, and aliquots are injected onto a standard reverse-phase HPLC column. The effluent from the HPLC column at 1 ml/min is introduced into the atmospheric pressure source of a SCIEX API III mass spectrometer. Azithromycin concentrations in serum are determined by the selected monitoring of the protonated molecular ions of the drug and the internal standard. Our assay yields accurate and precise results over the range 10 ng/ml to 250 ng/ml. The correlation between the assay and a standard HPLC-electrochemical method, requiring a larger volume of serum, has been determined. The two methods showed excellent agreement. Because of its low volume requirement, our HPLC-APCI assay can be substituted for the standard assay for the investigation of azithromycin pharmacokinetics in children.
The present work describes the development and application of an on-line atmospheric pressure ionisation (APCI) LC-MS interface for the simultaneous determination of seven toxicologically relevant cholesterol oxides (7alpha-hydroxycholesterol, 7beta-hydroxycholesterol, 25-hydroxycholesterol, 7-ketocholesterol, 5,6alpha-, 5,6beta-epoxycholesterol and cholestan-3beta,5alpha,6beta-triol). The HPLC method has been optimised to reach better separation of all tested compounds. The influences of APCI parameters (nebulising temperature, cone voltage, source temperature) on signal intensity and fragmentation pattern were investigated for all tested cholesterol oxides compounds. This is the first report on optimisation and determination of two compounds 7alpha-hydroxycholesterol and 5,6beta-epoxycholesterol in processed food using LC-MS. After extraction with hexane, clean-up was carried out using solid-phase extraction on a silica column. For the chromatographic separation of cholesterol oxides an Aquasil C18 column was used with acetonitrile-methanol (60:40) as mobile phase. For the first time we report the use of such a C18 column with a relatively hydrophilic nature for the separation of cholesterol oxides. APCI-MS detection was then applied in selected ion monitoring and positive ion modes by using the molecular ions and the main fragments. The developed method shows good linearity, high repeatability and good recovery for all tested cholesterol oxides. The method was applied for determination of seven selected cholesterol oxidation products in different foodstuffs such as butter, butteroil, lard and egg powder.
Atmospheric pressure matrix-assisted laser desorption/ionization (AP-MALDI) and ion trap mass spectrometry have been used to study the fragmentation behavior of native peptides and peptide derivatives prepared for de novo sequencing applications. Sulfonic acid derivatized peptides were observed to fragment more extensively and up to 28 times more efficiently than the corresponding native peptides. Tandem mass spectra of native peptides containing aspartic or glutamic acids are dominated by cleavage on the C-terminal side of the acidic residues. This significantly limits the amount of sequence information that can be derived from those compounds. The MS/MS spectra of native tryptic peptides containing oxidized Met residues show extensive loss of CH(3)SOH and little sequence-specific fragmentation. On the other hand, the tandem mass spectra of derivatized peptides containing Asp, Glu and oxidized Met show much more uniform fragmentation along the peptide backbone. The AP-MALDI tandem mass spectra of some derivatized peptides were shown to be qualitatively very similar to the corresponding vacuum MALDI postsource decay mass spectra, which were obtained on a reflector time-of-flight instrument. However, the ion trap mass spectrometer offers several advantages for peptide sequencing relative to current reflector time-of-flight instruments including improved product ion mass measurement accuracy, improved precursor ion selection and MS(n). These latter capabilities were demonstrated with solution digests of model proteins and with in-gel digests of 2D-gel separated proteins.
High performance liquid chromatography-atmospheric pressure chemical ionisation mass spectrometry (HPLC-APCI MS) was applied to the characterisation of triacylglycerols (TAGs) in animal fats. The major TAGs in four fats (beef, chicken, lamb and pork) were identified and positional isomers assigned according to their APCI mass spectra. Beef and lamb fat TAGs were confirmed as containing higher proportions of saturated fatty acids compared with those of chicken and pork. HPLC-APCI MS was also shown to be of value in providing regiospecific information for the fatty acids in individual TAG species. For example, beef and lamb fat were shown to contain both cis- and trans-isomers of the 18:1 fatty acid, whilst chicken and pork contained only the cis-isomer. When the position of fatty acid substitution was determined from the APCI spectra, whilst the cis- 18:1 was predominantly found in the 2-position of the TAG, the trans-18:1 showed a preference for the 1/3-position. Similarly, it was confirmed that although the 2-position of beef, chicken and lamb fat TAGs was dominated by unsaturated fatty acids, in pork fat, a characteristically high proportion of palmitic acid was seen in this position. The TAGs identified compared well with those reported previously. The distributions of 2-position fatty acids seen in lamb and pork fat compared favourably with those obtained by the more traditional method of lipase degradation. Although the distributions for chicken and beef showed some discrepancies, these can be attributed to weaknesses in the quantification procedure or the specificity of the lipase. Overall, the technique of HPLC-APCI MS has been shown to be very powerful for the regiospecific analysis of animal fats.
Infrared atmospheric pressure matrix-assisted laser desorption/ionization on an ion trap mass spectrometer is used to analyze frozen samples generated using a Peltier-cooled sample stage. This allows for the analysis of samples in water without the addition of matrix, in near-native conditions, and with minimal loss of water due to evaporation. Analysis of frozen samples is extended to study peptides, carbohydrates, and glycolipids.