PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “COMPRESSION”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15Linked to original sources

One-handed versus two-handed chest compressions in paediatric cardio-pulmonary resuscitation.

OBJECTIVES: To determine emergency department (ED) staff preference for one- or two-handed paediatric chest compressions and to determine if there was a difference in compression rates delivered and fatigability between the techniques. METHODS: This was a randomised, cross-over observational study of paediatric CPR performed on a standard paediatric manikin by ED staff. Consenting, eligible staff [ED doctors and nurses] performed CPR in pairs with chest compressions delivered using a one- and two-handed technique. The outcomes of interest were compression rates for one- and two-handed CPR, decrease in compression rate over time for each technique and staff preference for technique. Data was analysed using descriptive statistics, Chi Square test and Mann-Whitney U-test as appropriate. RESULTS: Sixty-two ED staff participated in the study. Compression rates with both techniques were similar and higher than guidelines recommend (133.6 min(-1) for one-handed and 135.7 min(-1) for two-handed respectively). The compression rate slowed by 6.9 compressions/min over 1 min in one-handed compressions compared with 2.6 compressions/min in two-handed compressions (p = 0.0264). 65.6% of participants reported that they preferred the two-handed compression technique. CONCLUSION: This study showed that CPR compression rate is similar with one- and two-handed compression techniques, but compression rate decreased more quickly with the one-handed technique. The majority of staff preferred the two-handed compression technique for reasons of ease, control and uniformity with other CPR techniques.

Cardiopulmonary Resuscitation↗

High-pressure, rapid-inflation pneumatic compression improves venous hemodynamics in healthy volunteers and patients who are post-thrombotic.

PURPOSE: Deep vein thrombosis (DVT) is a preventable cause of morbidity and mortality in patients who are hospitalized. An important part of the mechanism of DVT prophylaxis with intermittent pneumatic compression (IPC) is reduced venous stasis with increased velocity of venous return. The conventional methods of IPC use low pressure and slow inflation of the air bladder on the leg to augment venous return. Recently, compression devices have been designed that produce high pressure and rapid inflation of air cuffs on the plantar plexus of the foot and the calf. The purpose of this study is to evaluate the venous velocity response to high-pressure, rapid-inflation compression devices versus standard, low-pressure, slow-inflation compression devices in healthy volunteers and patients with severe post-thrombotic venous disease. METHOD: Twenty-two lower extremities from healthy volunteers and 11 lower extremities from patients with class 4 to class 6 post-thrombotic chronic venous insufficiency were studied. With duplex ultrasound scanning (ATL-Ultramark 9, Advanced Tech Laboratory, Bothell, Wash), acute DVT was excluded before subject evaluation. Venous velocities were monitored after the application of each of five IPC devices, with all the patients in the supine position. Three high-pressure, rapid-compression devices and two standard, low-pressure, slow-inflation compression devices were applied in a random sequence. Maximal venous velocities were obtained at the common femoral vein and the popliteal vein for all the devices and were recorded as the mean peak velocity of three compression cycles and compared with baseline velocities. RESULTS: The baseline venous velocities were higher in the femoral veins than in the popliteal veins in both the volunteers and the post-thrombotic subjects. Standard and high-pressure, rapid-inflation compression significantly increased the popliteal and femoral vein velocities in healthy and post-thrombotic subjects. High-pressure, rapid-inflation compression produced significantly higher maximal venous velocities in the popliteal and femoral veins in both healthy volunteers and patients who were post-thrombotic as compared with standard compression. Compared with the healthy volunteers, the patients who were post-thrombotic had a significantly attenuated velocity response at both the popliteal and the femoral vein levels. CONCLUSION: High-pressure, rapid-inflation pneumatic compression increases popliteal and femoral vein velocity as compared with standard, low-pressure, slow-inflation pneumatic compression. Patients with post-thrombotic venous disease have a compromised hemodynamic response to all IPC devices. However, an increased velocity response to the high-pressure, rapid-inflation compression device is preserved. High-pressure, rapid-inflation pneumatic compression may offer additional protection from thrombotic complications on the basis of an improved hemodynamic response, both in healthy volunteers and in patients who were post-thrombotic.

Adult↗

Augmentation of cardiac output and carotid blood flow by chest and abdomen phased compression cardiopulmonary resuscitation.

Phased compression cardiopulmonary resuscitation, whereby the chest and abdomen are compressed sequentially, is a new approach to the classical cardiopulmonary resuscitation technique, which is based on the compression of the chest alone. Six dogs with cardiac arrest were treated by external chest and abdominal compression using a rigid plexiglas suit lined with flexible perithoracic and periabdominal bladders. Fast inflation and deflation of the two independent bladders, together with forced ventilation of the lung, generated phased pressure pulses. The physiological variables monitored throughout the experiment included central venous, left ventricular, and central arterial pressures, carotid blood flow, cardiac output, and acid base balance. The phased compression technique was performed with phased time lags of 0, 150, 300, 400, 600, 700, and 850 ms between the abdominal and thoracic pressure pulses. A random sequence of the different phased compression modes, each lasting for 3-10 minutes, was applied during the prolonged resuscitation procedure that lasted for up to 70 minutes. By starting the abdominal compression 300-400 ms before the thoracic compression the carotid flow index improved by 77% (from 13% with simultaneous compression to 23% with phased compression) and the cardiac output index increased by 65% (from 7.8% with simultaneous compression to 12.5%). The results provide insight into the chest pump concept and the role of intrathoracic and intra-abdominal pressures in generating improved blood circulation during cardiopulmonary resuscitation, and show the advantages of phased compression over chest compression alone and simultaneous chest and abdominal compression.

Animals↗

Effects of ankle-to-knee external pressures on skin blood perfusion under and distal to compression.

OBJECTIVE: To compare the effects of select leg compression pressures on blood perfusion in the skin overlying bone and the skin distal to the leg compression. DESIGN: Blood perfusion of skin overlying the tibia and the foot dorsum was simultaneously measured in 12 healthy subjects using laser Doppler. Each subject's calf was compressed from ankle to knee with an air cast that applied external pressure, ranging from 0 to 40 mm Hg in 10 mm Hg increments. All measurements were initiated after a 20-minute rest interval and were recorded with each subject in a supine position. SETTING: University research center. RESULTS: The main findings show that compression causes a significant decrease in skin blood perfusion (SBF) at both sites, with greater reductions in SBF occurring with increased compression pressure. Greater SBF reductions occurred at the foot than at the directly compressed tibia site. Thus, at the highest pressure (40 mm Hg), the foot SBF reduction (61.6% +/- 13.7%) was greater than at the directly compressed tibial site (33.3% +/- 0.3%), both of which were significantly less than baseline (P <.01). CONCLUSIONS: The present findings and considerable related evidence indicate that lower extremity external compression, within the range of commonly used therapeutic levels, reduces SBF by an amount that depends on the magnitude of the compression pressures. The quantitative difference between the effect of compression on SBF within the compression area, and distal to it, is likely a result of the way that the compression affects arteriolar and venous resistance to blood flow at the 2 sites. From a clinical perspective, it would seem prudent to anticipate that sub-bandage and distal SBF would be negatively affected by compression, with greater effects likely in tissue distal to compression.

Adult↗

Performance of hearing-impaired listeners under various types of amplitude compression.

Speech perception by subjects with sensorineural hearing impairment was studied using various types of short-term (syllabic) amplitude compression. Average speech level was approximately constant. In quiet, a single-channel wideband compression (WBC) with compression ratio equal to 10, attack time 10 ms and release time 90 ms produced significantly higher scores than a three-channel multiband compression (MBC) or no compression when a nonsense syllable test (City University of New York) was used. The scores under MBC, WBC, or no compression were not significantly different when the modified rhyme test (MRT) was used. But when overshoots caused by compression were clipped, the MRT scores improved significantly. The influence of MBC on reverberant speech and of WBC on noisy speech were tested with the MRT. Reverberation reduced the scores, and this reduction was the same with compression as without. Noise added to speech before compression also reduced the scores, but the reduction was larger with compression than without. When noise was added after compression, an improvement was observed when WBC had a compression ratio of about 5, attack time 1 ms, and release time 30 ms. Other compression modes (e.g., with high-frequency pre-emphasis) did not show an improvement. The results indicate that WBC with a compression ratio around 5, attack time shorter than 3 ms, and release time between 30 and 90 ms can be beneficial if signal-to-noise ratio is large, or, if in a noisy or reverberant environment, the effects of noise or reverberation are eliminated by using listening systems.

Aged↗

Decomposition of protein experimental compressibility into intrinsic and hydration shell contributions.

The experimental determination of protein compressibility reflects both the protein intrinsic compressibility and the difference between the compressibility of water in the protein hydration shell and bulk water. We use molecular dynamics simulations to explore the dependence of the isothermal compressibility of the hydration shell surrounding globular proteins on differential contributions from charged, polar, and apolar protein-water interfaces. The compressibility of water in the protein hydration shell is accounted for by a linear combination of contributions from charged, polar, and apolar solvent-accessible surfaces. The results provide a formula for the deconvolution of experimental data into intrinsic and hydration contributions when a protein of known structure is investigated. The physical basis for the model is the variation in water density shown by the surface-specific radial distribution functions of water molecules around globular proteins. The compressibility of water hydrating charged atoms is lower than bulk water compressibility, the compressibility of water hydrating apolar atoms is somewhat larger than bulk water compressibility, and the compressibility of water around polar atoms is about the same as the compressibility of bulk water. We also assess whether hydration water compressibility determined from small compound data can be used to estimate the compressibility of hydration water surrounding proteins. The results, based on an analysis from four dipeptide solutions, indicate that small compound data cannot be used directly to estimate the compressibility of hydration water surrounding proteins.

Algorithms↗

Systolic compression of epicardial coronary and intramural arteries in children with hypertrophic cardiomyopathy.

It has been suggested that systolic compression of epicardial coronary arteries is an important cause of myocardial ischemia and sudden death in children with hypertrophic cardiomyopathy. We examined the associations between sudden death, systolic coronary compression of intra- and epicardial arteries, myocardial perfusion abnormalities, and severity of hypertrophy in children with hypertrophic cardiomyopathy. We reviewed the angiograms from 57 children with hypertrophic cardiomyopathy for the presence of coronary and septal artery compression; coronary compression was present in 23 (40%). The left anterior descending artery was most often affected, and multiple sites were found in 4 children. Myocardial perfusion abnormalities were more frequently present in children with coronary compression than in those without (94% vs 47%, P = 0.002). Coronary compression was also associated with more severe septal hypertrophy and greater left ventricular outflow gradient. Septal branch compression was present in 65% of the children and was significantly associated with coronary compression, severity of septal hypertrophy, and outflow obstruction. Multivariate analysis showed that septal thickness and septal branch compression, but not coronary compression, were independent predictors of perfusion abnormalities. Coronary compression was not associated with symptom severity, ventricular tachycardia, or a worse prognosis. We conclude that compression of coronary arteries and their septal branches is common in children with hypertrophic cardiomyopathy and is related to the magnitude of left ventricular hypertrophy. Our findings suggest that coronary compression does not make an important contribution to myocardial ischemia in hypertrophic cardiomyopathy; however, left ventricular hypertrophy and compression of intramural arteries may contribute significantly.

Adolescent↗

Evaluation of irreversible JPEG compression for a clinical ultrasound practice.

A prior ultrasound study indicated that images with low to moderate levels of JPEG and wavelet compression were acceptable for diagnostic purposes. The purpose of this study is to validate this prior finding using the Joint Photographic Experts Group (JPEG) baseline compression algorithm, at a compression ratio of approximately 10:1, on a sufficiently large number of grayscale and color ultrasound images to attain a statistically significant result. The practical goal of this study is to determine if it is feasible for radiologists to use irreversibly compressed images as an integral part of the day to day ultrasound practice (ie, perform primary diagnosis with, and store irreversibly compressed images in the ultrasound PACS archive). In this study, 5 Radiologists were asked to review 300 grayscale and color static ultrasound images selected from 4 major anatomic groups. Each image was compressed and decompressed using the JPEG baseline compression algorithm at a fixed quality factor resulting in an average compression ratio of approximately 9:1. The images were presented in pairs (original and compressed) in a blinded fashion on a PACS workstation in the ultrasound reading areas, and radiologists were asked to pick which image they preferred in terms of diagnostic utility and their degree of certainty (on a scale from 1 to 4). Of the 1499 total readings, 50.17% (95% confidence intervals at 47.6%, and 52.7%) indicated a preference for the original image in the pair, and 49.83% (95% confidence intervals at 47.3%, and 52.0%) indicated a preference for the compressed image. These findings led the authors to conclude that static color and gray-scale ultrasound images compressed with JPEG at approximately 9:1 are statistically indistinguishable from the originals for primary diagnostic purposes. Based on the authors laboratory experience with compression and the results of this and other prior studies, JPEG compression is now being applied to all ultrasound images in the authors' radiology practice before reading. No image quality-related issues have been encountered after 12 months of operation (approximately 48000 examinations).

Algorithms↗

Arterial compression of the retro-olivary sulcus of the ventrolateral medulla in essential hypertension and diabetes.

Pulsatile arterial compression in the retro-olivary sulcus along the surface of the ventrolateral medulla has been postulated as a mechanism in both essential hypertension and diabetes. The objective of this study was to test the independent effect of arterial compression in the retro-olivary sulcus on each of these diseases, using separate logistic regression models to control for other known risk factors. Study design was case-control. The study population consisted of 147 consecutive patients treated for neurological conditions requiring MRI of the posterior cranial fossa. Information on essential hypertension, diabetes, and risk factors for each disease was abstracted from medical records. Presence of arterial compression was determined by blinded review of magnetic resonance images. In the essential hypertension analysis, odds of arterial compression among hypertensive patients were 2.99-times the odds among normotensive subjects (P=0.04), controlling for hypertension risk factors such as age, body mass index, race, diabetes, and family history of hypertension. Of compressed hypertensive subjects, 56% were compressed on the left and 44% were compressed on the right. In the diabetes analysis, odds of arterial compression among diabetic subjects were 1.14-times the odds among nondiabetic subjects (P=0.83). Of compressed diabetic subjects, 60% were compressed on the left, and 40% were compressed on the right. Results suggest that arterial compression of the retro-olivary sulcus may be an independent risk factor for essential hypertension in this population, supporting the postulate for a treatable (with microvascular decompression) neural mechanism for essential hypertension. However, in the diabetic population, the slight increase in the odds of arterial compression was not significant.

Aged↗

Compressive biomechanical properties of human nasal septal cartilage.

BACKGROUND: Nasal septal cartilage is frequently used in nasal reconstruction and is a common source of chondrocytes for cartilage tissue engineering. The biomechanical properties of septal cartilage have yet to be fully defined and this limits the ability to compare it to the various alternative tissue-implant materials or tissue-engineered neocartilage. Given the unique structure and orientation of the septum within the nose, we sought to investigate anisotropic behaviors of septal cartilage in compression and correlate this to the concentration of glycosaminoglycans (GAG) and collagen within the cartilage. METHODS: Human nasal septal cartilage specimens were tested in confined compression, with each sample analyzed in a medial orientation and also either a vertical or caudal-cephalic orientation, with the order of tests randomized. The equilibrium confined compression (aggregate) modulus, HAO, and the permeability, kp, at different offset compression levels were obtained for each compression test. After testing, the cartilage samples were solubilized, and the concentrations of GAG and collagen were obtained. RESULTS: Forty-nine compression tests (24 medial, 12 vertical, 13 caudal-cephalic) were run on cartilage specimens obtained from 21 patients. There was a significant effect of orientation on compression modulus, HAO, with the vertical (0.7 +/- 0.12 MPa) and caudal-cephalic (0.66 +/- 0.01 MPa) orientations being significantly stiffer (p = 0.05) than the medial orientation (0.44 +/- 0.04 MPa). There was a trend of an orientation effect on kp at 15% offset compression (p = 0.12) and a borderline significant effect of orientation on kp at 30% offset compression (p = 0.05), demonstrating the M orientation to be more permeable than both the vertical and caudal-cephalic orientations. Both univariate and multivariate analysis did not demonstrate a significant effect of order of compression, age, gender, thickness, dry/wet weight, GAG, or collagen on either HAO, or kp values (p > 0.05). CONCLUSION: This study provides new information on the compressive properties of septal cartilage along different axes of compression. The results demonstrate that human septal cartilage is anisotropic; the compressive stiffness is higher in the vertical and caudal-cephalic orientations than in the medial orientation. Additionally, the medial orientation tends to have the greatest permeability. The data obtained in this study provide a reference to which various craniofacial reconstruction materials and tissue-engineered neocartilage can be compared.

Adolescent↗

Clinical signs and evoked response alterations associated with chronic experimental cord compression.

Cortical and spinal evoked potentials were used to monitor the effect of experimental chronic cord compression in cats. An implantable compression screw made it possible to maintain the animals unrestrained. The mean compression period was 10 weeks (maximum 16.5 weeks). Compression was increased by stepwise tightening of the screw at intervals of 4 to 7 days under ketamine anesthesia. Evoked potentials were monitored before and after each compression step with repeated recordings, and were analyzed in terms of alterations in amplitude, latency, and waveform. Amplitude response curves were plotted where the amount of compression at each recording was expressed as a percentage of total compression. Changes in spinal evoked potentials occurred rather early (mean 36% of total compression), while obvious cortical evoked potential changes appeared rather late (mean 91% of total compression). Neurological alterations appeared later than alterations in spinal evoked response but prior to alterations in cortical evoked response. Thus, alterations in cortical somatosensory evoked potentials in the presence of chronic spinal compression indicate a severe degree of compression and do not seem to be of diagnostic value in the early detection of chronic spinal cord compression. It is suggested that the monitoring of spinal rather than cortical evoked responses would be more useful in locating and detecting chronic compression spinal cord damage.

Animals↗

Evaluation of the influence of image compression to the automatic discrimination of histological images of skin lesions.

OBJECTIVES: Telemedicine offers the possibility to get the opinion of an expert within a short time. To reduce data transfer via a network image compression is recommended. The disadvantage of error-free compression is a low compression rate. On the other hand an increased compression rate affects the information content of the image. In this study we evaluated the influence of the compression rate on the automatic discrimination of histological skin lesions in dermatopathology. METHODS: To be independent from subjective reviewing by a dermatopathologist we used tissue counter analysis (TCA) for automatic discrimination of skin tissue. TCA is based on the partition of the image into square elements where the features are calculated out of each square element. 40 cases of benign common nevi and 40 cases of malignant melanoma were used as the study set. First TCA was applied to the uncompressed images to check the discrimination power of the method. Then in the next steps the method was applied to the images with successively higher compression rates. For image compression the wavelet compression was used, where the compression rate was determined by neglecting wavelet coefficients with a magnitude below a given threshold. The number of remaining wavelet coefficients was used as criteria for the compression rate. RESULTS: This study shows that TCA allows automated discrimination even at higher compression rates where only 6-18% of the wavelet coefficients are used for image reconstruction. The recognition rate at higher compression is better for malignant melanoma than for benign common nevi. CONCLUSION: The power of automated discrimination is not essential affected by wavelet image compression.

Austria↗

The dependence between the strength and stiffness of cancellous and cortical bone tissue for tension and compression: extension of a unifying principle.

A strong positive correlation between the apparent ultimate strength and stiffness of bone tissue that can be expressed by a unified relationship has been observed for cortical bone in tension and low-density cancellous bone in compression. For practical purposes, the existence of a relationship between strength and stiffness is significant in that bone stiffness can be measured in vivo using non-invasive methods. It is generally accepted that bone strength is greater in compression than in tension whereas there is no substantial evidence that bone stiffness in compression is different from that in tension. This might suggest that compressive strength would relate to the stiffness, if at all, in a way that is different from tensile strength. In order to examine similarities and differences in the way strength is associated with stiffness between modes of loading and tissue type, we tested equine cortical bone and bovine cancellous bone in compression and examined these data together with previously reported data from compression testing of human cancellous bone as well as tensile testing of cortical bone from various sources. We have found for cortical bone that (i) the sensitivity of strength to stiffness is the same for tension and compression (p>0.75, ANCOVA), and (ii) the difference between the magnitudes of compressive and tensile strength for cortical bone is the result of an additive, rather than a multiplicative factor (52.1 MPa after adjusting to 1 microstrain/s, p<0.0001, ANOVA). High-density bovine tibial cancellous bone, on the other hand, has a steeper slope for its compressive strength-stiffness relationship than that for cortical bone and human cancellous bone, resulting in a transitional relationship between compressive strength and stiffness for a range of bone types and densities. Based on the current results and previous work, it is suggested that the offset strength in the compressive strength-stiffness relationship may be a direct manifestation of the difference between the compressive and tensile strengths of the bone material that constitutes the building blocks of the bone structure. Deviation of high-density cancellous bone compressive behavior from the other bone types and densities is attributed to stress distribution differences between the bone types.

Adaptation, Physiological↗

Comparison of two intermittent pneumatic compression systems. A hemodynamic study.

AIM: Sequential leg compression has been previously shown to be superior to uniform compression. The aim of our study was to compare the hemodynamic effectiveness of the portable sequential compression device (SCD Express Compression System, Tyco Healthcare Group LP, Mansfield, MA, USA) with a rapid inflation device (VenaFlow, Aircast, Inc, Summit, NJ, USA). The former, by sensing venous refill time, commences compression when the calf veins are refilled. METHODS: The two devices were tested in 12 normal volunteers in the semirecumbent position using duplex ultrasound. Baseline and augmented flow velocity and volume flow were measured at the level of the common femoral vein, above the saphenofemoral junction. Refilling time was determined from velocity recordings of the common femoral vein. Total and peak volume of blood expelled per hour during compression were calculated using flow data and the individual cycling rate. RESULTS: Both devices increased venous flow velocity, up to 3.8 times the baseline (all P<0.001). Refill time of the rapid inflation device was shorter in comparison with the sequential compression device (15+/-2.2 vs 25+/-4 s; P<0.001), suggesting incomplete vein evacuation. The sequential compression device, by augmenting flow throughout a significantly longer compression period per cycle (10.9 s vs 6.3 s), expelled significantly more venous blood (121+/-68 vs 81+/-63 mL; P<0.001). Similarly, the total volume of blood expelled per hour with the sequential compression device was 100% higher than the rapid inflation device (9685+/-5426 vs 4853+/-3658 mL; P<0.001). Although peak velocity enhancement was higher with the rapid inflation device, flow augmentation (a product of average blood flow velocity) was comparable (669+/-367 vs 771+/-574 cm/s; P=0.223) with the sequential compression device, mainly because the rapid inflation device failed to maintain flow enhancement beyond the initial flow surge. CONCLUSIONS: Sequential compression showed hemodynamic superiority compared to a rapid inflation device. This was enhanced further by the sensing of refill time, which resulted in more compression cycles over time. The relative efficacy of the two devices in deep vein thrombosis prevention should be tested in future studies.

Blood Flow Velocity↗

Performing chest compressions in a confined space.

Standard cardiopulmonary resuscitation (CPR) may be difficult to perform in a confined space. This study set out to evaluate alternative techniques of chest compression, which may be easier to perform in such situations. Nineteen airline employees, trained in basic life support (BLS), were recruited to take part in the study. Following refresher training in standard one- and two-person CPR, they were taught two alternative techniques of chest compression: one-person over-the-head (OTH) and two-person straddle (STR). Their performances of chest compression during one-person standard CPR (St-1) and two-person standard CPR (St-2) were then compared with their performances during OTH and STR using a recording manikin. There were no statistically significant differences between the two-person methods of compression (St-2 and STR) for any of the parameters measured. There were no statistically significant differences between the one-person methods of chest compression (St-1 and OTH) for the average compression rate, the number of chest compressions achieved in a minute, or the average hands-off time per cycle. For OTH the average compression depth was significantly less than for St-1 (P = 0.0149) and there were more compressions of incorrect depth (P = 0.0400). The average duty cycle was significantly higher for OTH (P = 0.0045). 30.4% of compressions were incorrectly placed for OTH compared with 7.7% for St-1 (P = 0.0025). It was concluded that the quality of chest compression during two-person straddle CPR compares favorably with chest compression during standard two-person CPR, and may be useful in situations where space is limited. If only one rescuer is available to perform CPR, and limited space makes it impossible to carry out standard CPR, over-the-head CPR is an alternative method. However, in this study, hand placement during chest compression was poor, and additional training may be necessary before it can be considered a safe technique.

Adult↗

Compression force-depth relationship during out-of-hospital cardiopulmonary resuscitation.

BACKGROUND: Recent clinical studies reporting the high frequency of inadequate chest compression depth (<38 mm) during CPR, have prompted the question if adult human chest characteristics render it difficult to attain the recommended compression depth in certain patients. MATERIAL AND METHODS: Using a specially designed monitor/defibrillator equipped with a sternal pad fitted with an accelerometer and a pressure sensor, compression force and depth was measured during CPR in 91 adult out-of-hospital cardiac arrest patients. RESULTS: There was a strong non-linear relationship between the force of compression and depth achieved. Mean applied force for all patients was 30.3+/-8.2 kg and mean absolute compression depth 42+/-8 mm. For 87 of 91 patients 38 mm compression depth was obtained with less than 50 kg. Stiffer chests were compressed more forcefully than softer chests (p<0.001), but softer chests were compressed more deeply than stiffer chests (p=0.001). The force needed to reach 38 mm compression depth (F38) and mean compression force were higher for males than for females: 29.8+/-14.5 kg versus 22.5+/-10.2 kg (p<0.02), and 32.0+/-8.3 kg versus 27.0+/-7.0 kg (p<0.01), respectively. There was no significant variation in F38 or compression depth with age, but a significant 1.5 kg mean decrease in applied force for each 10 years increase in age (p<0.05). Chest stiffness decreased significantly (p<0.0001) with an increasing number of compressions performed. Average residual force during decompression was 1.7+/-1.0 kg, corresponding to an average residual depth of 3+/-2 mm. CONCLUSION: In most out-of-hospital cardiac arrest victims adequate chest compression depth can be achieved by a force<50 kg, indicating that an average sized and fit rescuer should be able to perform effective CPR in most adult patients.

Adolescent↗

Intermittent calf and foot compression increases lower extremity blood flow.

PURPOSE: Although foot compression increases foot skin perfusion and calf compression increases popliteal artery blood flow, these compression techniques have not been evaluated in combination. The purpose of this study was to evaluate whether calf and foot compression applied separately and simultaneously increase popliteal artery blood flow and/or foot skin perfusion, and to assess the relative merits of compression in patients with superficial femoral artery occlusion. METHODS: Twenty-two legs from 12 normal volunteers with ankle/brachial indices (ABIs) > 0.96, and 10 legs from 7 claudicator patients with angiographically documented superficial femoral artery (SFA) occlusion and patent popliteal arteries with ABIs < 0.8 were studied in the sitting position. Calf and foot cuffs connected to a rapidly inflating and deflating timed-pressure pump (Art-Assist-AA 1000; ACI Medical Inc., San Marcos, California) were applied to the subject in the sitting position. Skin blood flow of the great toe was measured with a laser doppler (Laserflo model BPM 403A; TSI Inc., St. Paul, Minnesota), and popliteal artery blood flow was measured using duplex ultrasonography (ATL-Ultramark 9; Advanced Tech Laboratory, Bothell, Washington). Foot and calf compression was applied separately and simultaneously at 120 mm Hg pressure, with a 10-second inflation and 20-second deflation cycle. Popliteal artery blood flow and foot skin perfusion were recorded and the mean of 6 cycles calculated. RESULTS: Precompression popliteal artery blood flow (mL/min) for volunteers was 38.86 +/- 3.94, and for patients was 86.30 +/- 14.55 (P = 0.001). Precompression foot skin perfusion (mL/min/ 100/g tissue) for volunteers was 1.67 +/- 0.29, and for patients was 4.00 +/- 0.92 (P = 0.01). With the application of calf, foot, and simultaneous calf and foot compression, the popliteal artery blood flow increased in volunteers by 124%, 54%, and 173%, respectively, and in patients by 76%, 13%, and 50%. Foot skin perfusion increased in volunteers by 260%, 500%, and 328%, respectively, and in patients by 116%, 246%, and 188%. Relative increases in popliteal artery blood flow and foot skin perfusion were higher in volunteers compared with patients during compression; however, the absolute values for foot skin perfusion and popliteal artery blood flow were consistently higher in patients. CONCLUSIONS: Measured in the sitting position, the resting popliteal artery blood flow and foot skin perfusion are greater in patients with SFA occlusion compared with normal volunteers. Following compression, popliteal artery blood flow and foot skin perfusion increased in both groups, but relatively more in volunteers. Increases in popliteal artery blood flow are significantly higher with calf compression than with foot compression for both groups. A patent SFA allows for additive increases in popliteal artery blood flow with simultaneous foot and calf compression in normal persons, whereas this is not observed in patients. However, the increases in foot skin perfusion in patients with an occluded SFA parallel the increases shown in normal volunteers, with separate and simultaneous foot and calf compression.

Adult↗

Removal of dermal edema with class I and II compression stockings in patients with lipodermatosclerosis.

BACKGROUND: Lipodermatosclerosis is a sequela of deep venous insufficiency and a risk factor for the occurrence of venous leg ulceration. Medical compression stockings facilitate leg ulcer healing and prevent occurrence of ulcers resulting from removal of edema. Although the exact level of compression necessary for removal of dermal edema in patients with deep venous insufficiency has not been established, garments providing high compressive values of 30 to 40 mm Hg have been recommended. Dermal edema can be visualized by high-frequency ultrasonography. OBJECTIVE: We used ultrasound imaging to study whether a lower level of compression (class I 18 to 26 mm Hg vs class II 26 to 36 mm Hg) is effective in removal of dermal edema. This question is important because the use of hosiery with a lower compression class would enhance compliance and enable treatment of patients with mixed arteriovenous disease. METHODS: In 11 patients skin images were obtained with 20 MHz ultrasound from the malleolar region in lipodermatosclerotic skin and corresponding normal skin of the contralateral leg. The ratio of low echogenic pixel number to total pixel number (LEP/TP), which correlates with dermal water, was measured before and after 5 days of applied compression in two treatment courses where classes of compression were switched randomly. Ankle circumference was also measured. RESULTS: We found that LEP/TP was 33% higher in lipodermatosclerotic skin than in the matched normal skin indicating presence of skin edema. Application of class I and II compressive hosiery resulted in LEP/TP decrease by 17% (95% confidence interval, 0.07 to 0.26) and 14% (95% confidence interval, 0.04 to 0.21), respectively, suggestive of dermal edema reduction. No statistically significant difference in efficacy of dermal edema removal between class I and II was found. No changes in ankle circumference after application of both classes of compression was observed. CONCLUSION: Application of light and moderate compression results in a partial edema removal from the dermis in lipodermatosclerosis in the absence of measurable reduction in leg circumference. Class I compression is as effective as class II for elimination of dermal edema. These data indicate that light compression may be a useful modality for patients with deep venous insufficiency and lipodermatosclerosis who are not eligible for treatment with garments having higher compressive forces.

Adult↗