[Calibration and standardization in enzyme immunoassay].

Calibration is performed using multipoints of the calibrator in enzyme immunoassay (EIA). Calibration curves in EIA are frequently represented by non-linearity. Therefore, calibration in EIA is fitted with suitable functions. These functions are demonstrated with logistic curve, logit-log conversion, spleen function, etc. Consequently, the calibration procedure is indicated for the manufacturer's instruction, and also the calibrator is prepared as a commercial available reagent kit. To minimize EIA measurements among laboratories, and among methods, standardization with a common suitable reference material is needed. Reference materials for EIA, international standards are prepared by the expert committee of WHO. These standards must be transferred to national standards, manufacturer's standards and calibrators of commercial available reagent kits. Finally, the measured value from the routine method is maintained with commutability and traceability.

Calibration↗

Effect of calibration on dispersion of glycohemoglobin values determined by 111 laboratories using 21 methods.

One hundred eleven laboratories, using 21 different methods based on five different principles, determined glycohemoglobin (GHb) percentages in two identical series of six lyophilized hemolysates and three similarly processed calibrators, distributed 3 months apart. To assign GHb percentages to calibrators, we used HbA1c results from nine participants who used the Bio-Rad Diamat high-performance liquid chromatographic method. Three-point calibration with assigned values improved mean intralaboratory variation (CV) from 6.6% to 3.5%. For samples with low (5.5%) and high (14.1%) GHb percentages, respectively, calibration decreased interlaboratory variation per method (from 10% to 4% and from 6% to 3%), inter-method variation (from 18% to 4% and from 16% to 3%), and overall interlaboratory variation (from 25% to 7% and from 15% to 4%). Without calibration, 71% of the laboratories did not meet the clinically desirable intralaboratory CV of 3.5%; calibration reduced this proportion to 39%. We conclude that, irrespective of the analytical method used, calibration greatly reduces all sources of GHb variation.

Calibration↗

Multi-center study of thromboplastin calibration precision--influence of reagent species, composition, and International Sensitivity Index (ISI).

Four thromboplastin reagents were tested by 18 laboratories in Europe, North-America, and Australasia, according to a detailed protocol. One thromboplastin was the International Reference Preparation for ox brain thromboplastin combined with adsorbed bovine plasma (coded OBT/79), and the second was a certified reference material for rabbit brain thromboplastin, plain (coded CRM 149R). The other two thromboplastin reagents were another rabbit plain brain thromboplastin (RP) with a lower ISI than CRM 149R and a rabbit brain thromboplastin combined with adsorbed bovine plasma (RC). Calibration of the latter two reagents was performed according to methods recommended by the World Health Organization (W.H.O.). The purpose of this study was to answer the following questions: 1) Is the calibration of the RC reagent more precise against the bovine/combined (OBT/79) than against the rabbit/plain reagent (CRM 149R)? 2) Is the precision of calibration influenced by the magnitude of the International Sensitivity Index (ISI)? The lowest inter-laboratory variation of ISI was observed in the calibration of the rabbit/plain reagent (RP) against the other rabbit/plain reagent (CRM 149R) (CV 1.6%). The highest inter-laboratory variation was obtained in the calibration of rabbit/plain (RP) against bovine/combined (OBT/79) (CV 5.1%). In the calibration of the rabbit/combined (RC) reagent, there was no difference in precision between OBT/79 (CV 4.3%) and CRM 149R (CV 4.2%). Furthermore, there was no significant difference in the precision of the ISI of RC obtained with CRM 149R (ISI = 1.343) and the rabbit/plain (RP) reagent with ISI = 1.14. In conclusion, the calibration of RC could be performed with similar precision with either OBT/79 or CRM 149R, or RP.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Determination of calibration function in thermal field flow fractionation under thermal field programming.

A new procedure for determining the calibration function able to relate retention and operative parameters to molecular weight of the species in thermal field flow (ThFFF) under thermal field programming (TFP) conditions is presented. The procedure involves determining the average values of retention parameters under TFP and determining a numerical function related to the temperature variations that occur during TFP. The calibration parameters are obtained by a procedure fitting the retention and operative parameters that hold true at the beginning of the TFP. The procedure is closely related to the one previously developed to calibrate the retention time axis under TFP ThFFF and, together, they constitute a full calibration procedure. Experimental validation was performed with reference to polystyrene (PS)-decalin and PS-THF systems. The calibration functions here obtained were compared to those derived by the classical procedure at constant thermal field ThFFF to obtain the calibration function at variable cold wall temperatures. Excellent agreement was found in all cases proving "universality" of the ThFFF calibration concept, i.e. it is independent of the particular system on which it was determined and can thus be extended to ThFFF operating under TFP. The new procedure is simpler than the classical one since it requires less precision in setting the instrumentation and can be obtained with fewer experiments. The potential applications for the method are discussed.

Journal Article↗

Comparison of the effects of potassium and pH on the calibre of cerebral veins and arteries.

The vasomotor response of individual pial veins and arteries on the convexity of the cerebral cortex to perivascular microinjection of mock cerebrospinal fluid (CSF) containing various concentrations of potassium (K+) and of various pH (achieved by altering the bicarbonate, HCO-3 concentration) have been examined in cats anaesthetised with alpha-chloralose. Microapplication of CSF containing 0 mM HCO-3 (pH 4.80) effected significant increases in calibre of pial veins and arteries of 9.3 +/- 2.4% and 38.2 +/- 4% respectively (mean calibre change +/- SE), whereas CSF containing 22 mM HCO-3 (pH 7.45) which constricted pial arteries significantly (-18.5 +/- 2.9%) minimally altered venous calibre (-4.3 +/- 2.2%). Microapplication of CSF containing 0 mM potassium resulted in a significant reduction in pial arterial calibre (-11.4 +/- 2.8%) but failed to alter pial venous calibre (-0.3 +/- 0.6%). Perivascular microapplication of CSF containing moderately elevated potassium concentrations (10 mM) which effected marked, significant increases in pial arterial calibre (49.3 +/- 3.9%) did not significantly alter the calibre of the pial veins (mean response -1.6 +/- 2.4%). The perivascular administration of CSF containing a high concentration of potassium (40 mM) resulted in the significant constriction of both pial veins (-13.5 +/- 0.9%) and pial arteries (-47.2 +/-6.3%). The magnitude of the response was significantly smaller in the pial veins. The relative insensitivity to K+ and pH of the pial veins as compared to pial arteries suggests that alteration in the chemical composition of of the perivascular fluid are of lesser importance in the control of cerebrovascular capacitance than for the regulation of cerebrovascular resistance.

Animals↗

Elucidation of accuracy in calibration of MR signal intensity based on transmission amplitude method.

To calibrate magnetic resonance (MR) signal intensity that depends on radio frequency (RF) coil loading, the transmission amplitude (TRA) for the excitation in the transmit-receive RF coil has been used as a good index in the so-called TRA method. As this TRA method needs neither an internal reference nor an additional external reference for the calibration, its accuracy is free from reference measurements. This study elucidated the calibration accuracy of MR signal intensities based on the TRA method. A cylindrical gel phantom was used for accuracy measurements with a 1.5-T MRI unit with conventional T1 imaging as a simple pulse sequence for various loading conditions. The brain parenchyma of eight healthy volunteers also showed calibrated MR signal deviations. The error of the phantom calibration measurements was 2.18% (S.D.%). The background noise intensity of images was theoretically derived to correlate with the impedance mismatching of the RF coil, which is inevitable for fixed tuning, even for automatic tuning that is not always exact. Taking into account this noise intensity, the calibration method was modified to reduce its error to 1.50%. The standard deviations of the calibrated values in the thalamus and frontal white matter were 2.9 and 3.8%, respectively. We suggest that the modified TRA method is a practical and reliable technique to obtain clinical numeric evidence.

Brain↗

Statistical survey of "saturation analysis" calibration curve data for prednisolone, prednisone and digoxin.

An extensive survey of radioimmunoassay calibration data for prednisolone, prednisone and digoxin indicated that the common practice of preparing calibration curves with individual subject's pre-dose plasma or serum, and using this to estimate unknown concentrations for the same subject, is not supported by statistical considerations. Preparation of calibration plots from pooled data is better because this introduces less bias in estimated concentrations. Such a method also saves a great deal of time, since it is not necessary to repeat the calibration procedure each time, "unknowns" are being assayed. The data suggest that there is no optimum calibration plot for all radioimmunoassays. Rather, each antibody-drug combination should be investigated thoroughly to determine the best calibration plot for the particular combination. We found that the best calibration plots are: the logistic-logarithmic plot for prednisolone; nonlinear least squares fit to a polyexponential equation for nisolone; nonlinear least squares fit to a polyexponential equation for prednisone; and a weighted least squares regression of normalized % bound versus concentration for figoxin. The error in the radioimmunoassay is usually concentration-dependent, and, in certain regions of the standard curve, is larger than the literature indicates, since, frequently, the error has been gauged from % bound values, but should be guaged from inversely-estimated concentrations.

Digoxin↗

Appropriateness of plane pressure-sensitive film calibration for contact stress measurements in articular joints.

OBJECTIVE: To examine how accurately calibration stains from pressure-sensitive film samples compressed between perfectly flat surfaces represent contact pressures measured with the film inserted between curved joint surfaces. DESIGN: Experimental study. BACKGROUND: Contact pressure distributions and areas in joints are often quantified using pressure-sensitive film inserted between the articular surfaces. Absolute pressure values are recovered from the film through a calibration procedure. Since the calibration is typically performed in a different environment from the experimental measurements, a systematic error in the pressure magnitudes may be introduced. METHODS: Calibration stains were produced with an Instron machine using a flat and a slightly curved indenter. Calibration curves were fitted to the raw data of both indenters using a model representing the functional characteristics of the pressure-sensitive film. RESULTS: No systematic differences between the calibration curves from the flat and the curved indenter were observed. CONCLUSIONS: It appears that calibration with the film in a flat configuration is adequate for contact pressure measurements between moderately curved articular surfaces.

Journal Article↗

TOF-SIMS: accurate mass scale calibration.

A study is presented of the factors affecting the calibration of the mass scale in time-of-flight secondary ion mass spectrometry (TOF-SIMS). At the present time, TOF-SIMS analysts using local calibration procedures achieve a rather poor relative mass accuracy of only 150 ppm for large molecules (647 u) whereas for smaller fragments of <200 u this figure only improves to 60 ppm. The instrumental stability is 1 ppm and better than 10 ppm is necessary for unique identification of species. The above experimental uncertainty can lead to unnecessary confusion where peaks are wrongly identified or peaks are ambiguously assigned. Here we study, in detail, the instrumental parameters of a popular single stage reflection TOF-SIMS instrument with ion trajectory calculations using SIMION. The effect of the ion kinetic energy, emission angle, and other instrumental operating parameters on the measured peak position are determined. This shows clearly why molecular and atomic ions have different relative peak positions and the need for an aperture to restrict ions at large emission angles. These data provide the basis for a coherent procedure for optimizing the settings for accurate mass calibration and rules by which calibrations for inorganics and organics may be incorporated. This leads to a new generic set of ions for mass calibration that improves the mass accuracy in our interlaboratory study by a factor of 5. A calibration protocol is developed, which gives a relative mass accuracy of better than 10 ppm for masses up to 140 u. The effects of extrapolation beyond the calibration range are discussed and a recommended procedure is given to ensure that accurate mass is achieved within a selectable uncertainty for large molecules. Additionally, we can alternatively operate our instrument in a regime with good energy discrimination (i.e., poor energy compensation) to study the fragmented energies of molecules. This leads to data that support previous concepts developed in G-SIMS.

Journal Article↗

Calibration of AFM cantilever stiffness: a microfabricated array of reflective springs.

Calibration of the spring constant of atomic force microscope (AFM) cantilevers is necessary for the measurement of nanonewton and piconewton forces, which are critical to analytical applications of AFM in the analysis of polymer surfaces, biological structures and organic molecules. We have developed a compact and easy-to-use reference standard for this calibration. The new artifact consists of an array of 12 dual spiral-cantilever springs, each supporting a mirrored polycrystalline silicon disc of 160 microm in diameter. These devices were fabricated by a three-layer polysilicon surface micromachining method, including a reflective layer of gold on chromium. We call such an array a Microfabricated Array of Reference Springs (MARS). These devices have a number of advantages. Cantilever calibration using this device is straightforward and rapid. The devices have very small inertia, and are therefore resistant to shock and vibration. This means they need no careful treatment except reasonably clean laboratory conditions. The array spans the range of spring constant from around 0.16 to 11 N/m important in AFM, allowing almost all contact-mode AFM cantilevers to be calibrated easily and rapidly. Each device incorporates its own discrete gold mirror to improve reflectivity. The incorporation of a gold mirror both simplifies calibration of the devices themselves (via Doppler velocimetry) and allows interferometric calibration of the AFM z-axis using the apparent periodicity in the force-distance curve before contact. Therefore, from a single force-distance curve, taking about one second to acquire, one can calibrate the cantilever spring constant and, optionally, the z-axis scale. These are all the data one needs to make accurate and reliable force measurements.

Journal Article↗

Quantitative nanotribology by AFM: a novel universal calibration platform.

The quantitative determination of friction forces by atomic force microscopy (AFM) in nanotribology requires the conversion of the output voltage signal of the sector area-sensitive photodiode to force using (a) the torsional spring constant of the cantilever and (b) the lateral sensitivity of the photodiode. Many existing methods provide calibration factors with large errors and suffer from poor reproducibility. We report on the fabrication, validation, and application of a new, universally applicable standard specimen that enables one to accurately calibrate all types of AFM cantilevers and tips for quantitative friction force measurements. The Si(100) calibration standard, which exhibits 30 and 50 mum wide notches with tilt angles theta between 20 degrees and 35 degrees with respect to the wafer surface, was fabricated by focused ion beam (FIB) milling. The quantification of friction forces obtained on this universal standard specimen using a direct method (the improved wedge calibration method, as introduced by Ogletree, Carpick, and Salmeron Rev. Sci. Instrum. 1996, 67, 3298-3306), which yields (a) and (b) simultaneously, was critically tested for various types of Si3N4 integrated cantilever-tip assemblies. The error in the calibration factors obtained was found to be ca. 5%, which is a significant improvement compared to errors of 30-50% observed for the often applied two-step calibration procedures of cantilever lateral force constant and photodiode sensitivity. As demonstrated for oxidized Si(100), thin films of poly(methyl methacrylate) (PMMA), and micropatterned self-assembled monolayers (SAMs) on gold, the calibration of various V-shaped and single beam cantilevers based on the application of the new universal standard in conjunction with the direct wedge method proposed allows one to conveniently perform quantitative nanotribological measurements for a wide range of materials and applications.

Journal Article↗

Calibration of measures for psychotherapy outcome studies.

Many findings in psychology, including those in psychotherapy, lack interpretability because measures are not in any meaningful metric. Measures need to be calibrated so as to endow them with inherent meaning. In particular, it is important to calibrate measures against behaviors and real events in people's lives. Approaches to calibrating measures include calibration against direct personal experience, against cross-experiential equivalents, and against cross-modal equivalents, to reflect empirically established behavioral implications as well as just noticeable differences in behavior or between people. Psychological measures may never be as closely calibrated as those for physical properties, but wider reporting of unstandardized regression equations would be of great help. Psychological measures also need to be calibrated against each other so as to permit easy transformations of values or substitutions of measures. Finally, greater standardization of measures is recommended so as to produce better bases for calibration.

Humans↗

Do lymphocytes require calibration?

Complexity in the activation/regulatory apparatus and the variable nature of the antigen-binding site dictate that B and T cells establish and select, during their development, appropriate activation and control mechanisms beyond simple antigen-binding specificity. These mechanisms are established partly by fixed interactions dictated by genetically defined structures, but they are also attained by calibration during ontogeny. This calibration depends on the ordered expression of early components (each of which is invariant), on their interaction with specific ligands, and on the receipt of invariant signals for calibration. Lymphocytes calibrate themselves by expressing various cell surface components, such as restricted heavy chain D-regions and pseudo-light chains. These are expressed in association with elements that will make up the antigen-receptor complex of mature lymphocytes. Calibration by invariant signals results in the establishment, selection and active maintenance of cellular activities which serve to control lymphocyte function. Since these cellular activities are one of a number of possible conditions, they are referred to as variant controls. Effectively calibrated basic cellular functions, specialized responses and cellular interactions allow lymphocytes to attain self-nonself discrimination. If calibration fails, lymphocytes will develop abnormalities, such as immunodeficiency and autoimmunity.

Animals↗

On the use of "calibration equations" in perception research.

Gogel's procedure of using "calibration equations" to obtain reports of perceived distance which are at least partially independent of individual differences in response bias, was examined. The procedure involves determining the relationship between reported and physical distances in a full-cue viewing situation. By making four assumptions, this equation can be used to "calibrate" responses gathered from other situations in which perceived distances are under investigation. In the present experiment, both verbal and string-pull measures of perceived distance were obtained for several objects under reduced viewing conditions. Calibration equations were determined for each response measure in a full-cue setting. The usefulness of the calibration technique was tested by comparing the differences between the two response measures for each object seen in reduced viewing, both before and after the application of the calibration procedure. The results indicated that, consistent with the usefulness of the calibration technique, group differences between the measures were almost always decreased by the procedure. However, no general improvement in the agreement of the measures was found when the data were examined on an individual basis. From the results, a modification of the method of calculating calibration equations was suggested that might increase its usefulness by simplifying the arithmetic operations required for the procedure.

Adolescent↗

The calibration of CT Hounsfield units for radiotherapy treatment planning.

Computer tomographic (CT) scans are used to correct for tissue inhomogeneities in radiotherapy treatment planning. In order to guarantee a precise treatment, it is important to obtain the relationship between CT Hounsfield units and electron densities (or proton stopping powers for proton radiotherapy), which is the basic input for radiotherapy planning systems which consider tissue heterogeneities. A method is described to determine improved CT calibrations for biological tissue (a stoichiometric calibration) based on measurements using tissue equivalent materials. The precision of this stoichiometric calibration and the more usual tissue substitute calibration is determined by a comparison of calculated proton radiographic images based on these calibrations and measured radiographs of a biological sample. It has been found that the stoichiometric calibration is more precise than the tissue substitute calibration.

Humans↗

Size-exclusion chromatographic determination of polymer molar mass averages using a fractal calibration.

The characterization of polymers by size-exclusion chromatography basically consists of the determination of the weight-average molar mass (Mw), number-average molar mass (Mn), and polydispersity index (I). An accurate estimation of these magnitudes requires the use of a reliable and trusted calibration curve. Three procedures for building up a calibration curve are analyzed in this work. The first is the classical universal calibration (UC), based on the elution of tetrahydrofuran-polystyrene in a system as reference. The second is based on the proper calibration curve made with standards of the sample under study. However, two main drawbacks arise when using these methodologies: the nonfulfilment of the UC when secondary mechanisms, other than pure size-exclusion, are present in the separation process; and the lack of a broad set of narrow standards of the sample under analysis in the second procedure. In order to circumvent these difficulties, a third, recently-proposed approach based on fractal considerations is applied. The accuracy and reliability of this method is proven through the calculation of the deviations observed in the estimation of the Mw values for polymer samples in different solvent-gel chromatographic systems. Whereas the classical UC shows a mean deviation of approximately 80% relative to the values given by the manufacturer, the fractal calibration yields a mean deviation of approximately 16%, similar to that obtained from the proper calibration. Moreover, the fractal procedure only needs one polymeric sample to generate the calibration curve.

Journal Article↗

A simple mathematical modification of TRISS markedly improves calibration.

BACKGROUND: TRISS has reigned as the preeminent trauma outcome prediction model for 20 years. Despite this endorsement, the calibration of TRISS has been poor in most data sets where it has been examined. We hypothesized that the lack of calibration of TRISS was because of the inappropriate mathematical specification of the model that TRISS is based on, rather than the predictors in the model. In particular, we hypothesized that the nonlinearity of the Injury Severity Score (ISS) in the log odds of death was responsible for the poor calibration of TRISS, and further, that this nonlinearity could be corrected by the simple addition of an ISS squared term to the TRISS model. METHODS: We examined ISS in the log odds of mortality for linearity in one large trauma data set, the National Pediatric Trauma Registry (NPTR) (n = 53,113 from 1985-1996; mortality, 1.3%); and two small data sets, the University of New Mexico (UNM) (n = 3,142 from 1991-1995; mortality, 8.6%) and Portland, Oregon (PORT) (n = 2,916 from 1990-1994; mortality, 1.75%). In addition, in the NPTR we compared the calibration of TRISS models with and without linearity in the log odds of death. RESULTS: In the NPTR, ISS was profoundly nonlinear in the log odds of death for both blunt and penetrating trauma (p < 0.001). Moreover, the overall calibration of the TRISS model for the NPTR data was significantly improved when the nonlinearity of ISS was corrected by the addition of a quadratic ISS term as demonstrated by a 70% reduction (improvement) in the Hosmer-Lemeshow statistic. Interestingly, the addition of the ISS squared term did not affect the discrimination of the model. The log odds of survival in the UNM and PORT data sets were also better modeled when an ISS squared term was added (UNM, p = 0 0.052; PORT, p = 0.014), but improvements in the Hosmer-Lemeshow statistic were smaller, possibly because of the small size of these data sets. CONCLUSION: The TRISS model for outcome prediction currently uses ISS in a mathematically inappropriate way that impairs the calibration, but not the discrimination, of its predictions. If TRISS is to continue as the prediction standard for trauma, a quadratic ISS term must be added to the model. In the future, outcome prediction models should undergo thorough statistical modeling and evaluation before being released. Injury severity descriptors other than ISS (such as ASCOT, ICISS, or NISS) may require other modeling techniques to optimize the calibration of survival models that use these injury scores.

Adolescent↗

Calibration age and quartet divergence date estimation.

The date of a single divergence point--between living alligators and crocodiles--was estimated with quartet dating using calibrations of widely divergent ages. For five mitochondrial sequence datasets, there is a clear relationship between calibration age and quartet estimate--quartets based on two relatively recent calibrations support younger divergence estimates than do quartets based on two older calibrations. Some of the estimates supported by young quartets are impossibly young and exclude the first appearance of the group in the fossil record as too old. The older estimates--those based on two relatively old calibrations--may be overestimates, and those based on one old and one recent calibration support divergence estimates very close to fossil data. This suggests that quartet dating methods may be most effective when calibrations are applied from different parts of a clade's history.

Alligators and Crocodiles↗