PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “PICRATES”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15Linked to original sources

[The value of fingernail creatinine measurement in the identification of acute and chronic renal failure].

It is difficult to distinguish acute renal failure (ARF) clinically from chronic renal failure (CRF), especially in the patients who do not have medical history records. Since fingernail creatinine (Ncr) reflects serum creatinine (Scr) at the time of nail formation, it has been suggested that Ncr level might represent that of Scr around 4 months previously. In this study, clipped fingernail specimens from 60 normal individuals (Scr 85.75 +/- 3.54 mumol/L), 35 patients with CRF (Scr 568.41 +/- 47.74 mumol/L) and 15 patients with ARF (Scr 123.60 +/- 17.29 mumol/L) were analyzed for creatinine by a standard alkaline picrate method. The results showed that Ncr level was significantly lower in the normal group (61.89 +/- 10.25 mumol/100g fingernail) than in the CRF group (130.04 +/- 34.55 mumol/100g fingernail) P less than 0.001. In the ARF group Ncr level (65.59 +/- 2.5 mumol/100g fingernail) was more or less the same as that in normal controls. It is concluded that Ncr measurement is of clinical value in identification of ARF.

Acute Kidney Injury↗

A simplified procedure for eliminating the negative interference of bilirubin in the Jaffé reaction for creatinine.

The negative interference by bilirubin in the measurement of creatinine by the Jaffé procedure is well documented. We describe a procedure for the elimination of interfering bilirubin by oxidation to biliverdin through the addition of potassium ferricyanide before the alkaline picrate reagent. We detected no negative interference with the addition of as much as 600 mumol/L bilirubin. The procedure shows good agreement with a recently described blank rate method for analyzing icteric samples.

Bilirubin↗

Preparation of inner ear sensory hair bundles for high resolution scanning electron microscopy.

Chemical fixation techniques for preservation of sensory hair bundles in the mammalian inner ear for scanning electron microscopy (SEM) are reviewed. Fixatives employed were glutaraldehyde, glutaraldehyde-picrate, glutaraldehyde-tannic acid, glutaraldehyde-formaldehyde, glutaraldehyde followed by postfixation with osmium tetroxide and the osmium thiocarbohydrazide (OTOTO) method. Dehydration was routinely accomplished with ascending grades of acetone followed by critical point drying with liquid CO2 or fluorocarbon sublimation. Specimens other than those prepared by the OTOTO method were metal coated with gold, gold-palladium or platinum. Material was viewed at high resolution (2-3 nm) in a transmission electron microscope (TEM) fitted with a scanning system and an LaB6 filament. A few specimens, which were either coated with platinum, carbon or uncoated, were examined in a field emission SEM. We have concluded that glutaraldehyde fixation followed by critical point drying with CO2 and coating with platinum gives the best general preservation of stereocilia and their cross-links for routine high resolution SEM, but that carbon-coated or uncoated specimens offer potentially better results free from metal coating artifacts when viewed with field emission SEM. These methods have enabled us to make novel observations upon the surface detail and cross-links of stereocilia which have helped considerably in understanding the mechanical properties of hair bundles particularly in relation to sensory transduction. We have found that stereocilial surface detail and cross-links are sensitive to fixation regimens. In particular they are degraded by exposure to osmium tetroxide; they are also highly labile since deleterious changes in their appearance can be detected as early as 15 minutes following death.

Animals↗

Use of a synthetic soluble bilirubin derivative to assess interference in creatinine measurements.

In assessing interference from bilirubin, the use of a synthetic soluble derivative (ditaurobilirubin, DTB) is recommended as a surrogate for the natural conjugates (Bc). We compared the interference effect of unconjugated bilirubin (Bu), Bc, and DTB, using six mechanized methods for serum creatinine measurement. No significant interference was noted in methods that include removal of proteins or in an enzymatic method involving NADH oxidation. Heavy (negative) interference was observed in an alkaline picrate method, and in direct enzymatic methods based on hydrogen peroxide measurement: interference was always more pronounced in the presence of the two soluble derivatives (Bc and DTB), whose interference was of the same magnitude. These results point out the utility of testing for bilirubin interference by using soluble derivatives, in addition to Bu, and suggest the feasibility of using DTB as a surrogate for Bc for this purpose.

Bilirubin↗

[The stabilization of physostigmine salicylate injection solutions. 2].

In a long term test covering 4 years the potency of stabilizing agents for 0.04% physostigmine salicylate (1) solutions was studied under thermal loading. Thereby complex stabilizers were used as well as simple stabilizing agents. The most effective stabilization was achieved with 0.1% ascorbic acid. The results of the 1th information concerning the stabilization of a 0.1% 1 injection solution with ascorbic acid over a period of one year were confirmed in a long term test for 0.04% 1 solutions. At the some time these long term tests confirmed the formulation as being established for the "Standard Formulas 1988". The stability tests were carried out spectrophotometricly by using the picrate method. Other methods mentioned in literature gave no satisfying reproducibility.

Chemistry, Pharmaceutical↗

Effects of the local anesthetic bupivacaine on oxidative phosphorylation in mitochondria. Change from decoupling to uncoupling by formation of a leakage type ion pathway specific for H+ in cooperation with hydrophobic anions.

The effects of the local anesthetic bupivacaine on the oxidative phosphorylation in rat liver mitochondria were examined. Bupivacaine caused a maximum of about 7-fold stimulation of state 4 respiration at about 3 mM, released oligomycin-inhibited state 3 respiration, and activated ATPase to a similar extent to that by the weakly acidic uncoupler SF 6847. These effects were greatly enhanced by the addition of certain hydrophobic anions such as 1-anilino-8-naphthalenesulfonate, tetraphenyl borate, and picrate. In the absence of these anions, bupivacaine did not increase the proton conductance in either energized or nonenergized mitochondrial membranes or in artificial bilayer lipid membranes and did not have any effect on the proton motive force. However, it greatly enhanced the proton conductivity of these membrane systems and collapsed the proton motive force in the presence of hydrophobic anions. The results of noise analysis of artificial lipid bilayer membranes indicated that an ion pair complex of bupivacaine with hydrophobic anions formed a leakage-type ion pathway. Thus it is concluded that bupivacaine acts as a decoupler in the absence of added hydrophobic anions but in cooperation with certain anions as an uncoupler of oxidative phosphorylation due to formation of a H(+)-specific pathway in the membranes.

Adenosine Triphosphatases↗

Determination of creatinine in serum and urine by a rapid liquid-chromatographic method.

We describe an HPLC ion-pair procedure for rapid and specific evaluation of creatinine in serum and urine. We used a 15 cm X 4.6 mm ODS column with a 50/50 (by vol) mixture of sodium decanesulfonic acid (10 mmol/L, pH 3.2) and methanol and measured absorbance at 236 nm. Serum (100 microL) or 30-fold-diluted urine (100 microL) was added to 400 microL of acetone. After centrifugation, the supernates (300 microL) were dried, reconstituted with the mobile phase, and injected into the HPLC. Assay precision was tested for concentrations of 10, 29, and 130 mg/L and yielded, respectively, 3.1%, 2.1%, and 1.1% for within-day CV and 2.8%, 2.1%, and 2.2% for total CV. Analytical recovery was 102 (+/- 6.7%). Linearity was demonstrated in the 0-200 mg/L range for serum and 0-3.5 g/L range for urine (r greater than or equal to 0.999). The detection limit for creatinine (signal-to-noise ratio = 3) was 0.5 mg/L. We used cimetidine for internal standardization. Correlation was good between this procedure and the Jaffé kinetic, the enzymatic (creatinine amidohydrolase), and the Fuller's earth alkaline picrate methods.

Chromatography, High Pressure Liquid↗

Effect of heat treatment on plasma creatinine measurement.

The effects of heat treatment on plasma creatinine values obtained by enzymatic and kinetic alkaline picrate methods were compared. No marked differences were found for plasma samples following heat treatment at 56 degrees C for 0.5 or 1 h, compared to nonheat treated samples.

Creatinine↗

A peroxidase-coupled kinetic enzymatic procedure evaluated for measuring serum and urinary creatinine.

We evaluated an enzymatic procedure for the automated determination of serum and urinary creatinine. The procedure was sensitive and precise for serum creatinine concentrations as low as 3 mg/L, and the standard curve was linear to 200 mg/L. Measurements of creatinine in clinical serum and urine specimens agreed with those obtained by two other enzymatic methods and four picric acid methods. There was no interference from picrate-reactive substances tested. Among other substances, bilirubin (50-100 mg/L) interfered negatively with the assay, decreasing apparent creatinine concentrations by as much as 6 mg/L. The advantages of specificity, speed, and convenience make this enzymatic procedure an attractive primary or secondary method for creatinine determinations in clinical laboratories.

Adult↗

How certain drugs interfere negatively with the Jaffé reaction for creatinine.

Phenacemide and cephalothin may interfere either positively or negatively with the determination of creatinine by the Jaffé reaction, depending on the analytical system. The drug-picrate chromophores maximally absorb within the first minute of reaction (21 s for phenacemide, 45 s for cephalothin), after which the absorbances decrease. Thus, these drugs negatively interfere in analytical systems involving kinetic measurements when the time interval of measurement includes the period of decreasing absorbance.

Autoanalysis↗

[Enzymatic assay of creatinine in serum: comparison with Jaffé methods (author's transl)].

The creatinine concentrations in 337 sera were determined by enzymatic assay and by six different modifications of the Jaffé method. The enzymatic assay showed satisfactory precision and gave the same results as the assay after adsorption on Fuller's earth (Lloyd's reagent). All other methods using picrate gave falsely high values: the relative deviation from the enzymatic method had a median value between +20% and +50% for creatinine concentrations in the range 22-88 mu mol/l, and between +10% and 30% for creatinine concentrations in the range 89-177 mu mol/l. The study thus confirms the lack of specificity of all Jaffé methods, with the exception of the assay after adsorption on Fuller's earth.

Creatinine↗

Enzymatic assay for creatinine with fixed-time kinetics on a centrifugal analyzer.

A method is described for enzymatic measurement of serum creatinine using a centrifugal analyzer. The method employs fixed-time kinetics and a true serum blank. The method required 100 microliters of serum and is linear to 90 mg per L. Day-to-day precision studies revealed a standard deviation (coefficient of variation) of less than +/- 0.5 mg per L (7.4 percent) at a mean creatinine concentration of 6 mg per L and +/- 0.5 mg per L (1.8 percent) at a mean value of 28 mg per L. The method was free of interferences from acetoacetic acid, ascorbic acid, bilirubin, and hemoglobin. The speed, precision, and accuracy of the method suggest that it represents a useful alternative to methods using the alkaline picrate procedure.

Amidohydrolases↗

Spironolactones and glomerular filtration.

For pharmacologic screening to identify hyperaldosteronism in patients after renal transplantation, spironolactone (Soludactone, Searle) was administered intravenously in 12 subjects (mean dose 1.2 g in the course of 3 days). After its administration a decrease in glomerular filtration rate was assessed when measured by chromogen clearance. Simultaneous measurement of creatinine showed no change, nor was there any change in the plasma level and excretion fraction of urea. The decrease in chromogen clearance was due to an increase in plasma level of the chromogen. Thus the decrease in its clearance was an artifact resulting most probably from the reaction of spironolactone metabolites with alkaline picrate, which was used for the determination of chromogen. In addition to the causes of the glomerular filtration rate decrease after spironolactone which have been reported in the literature - volume depletion and direct influence on the kidneys - the possibility of a fictive decrease must be taken into consideration.

Adult↗

Serum creatinine. A CAP survey.

The results of the 1976--1977 College of American Pathologists Survey of serum creatinine measurements performed by more than 5,000 laboratories are presented. The most widely used method employs the colorimetric measurement of the alkaline picrate-creatinine (Jaffe) reaction. In general, all manual and automated systems yielded comparable creatinine concentrations except the centrifugal analyzers, which manifested a consistently high bias. Interlaboratory variation was lowest for continuous-flow and the DuPont discrete systems. Lloyd's reagent resulted in a clinically insignificant reduction of creatinine concentration in lyophilized sera.

Autoanalysis↗

Ethanol mustard cytotoxicity in vitro toward murine leukemia and bone marrow progenitor cells.

Ethanol mustard, 2-[bis(2-chloroethyl)amino]ethanol-picrate, was approximately one tenth as cytotoxic as mechlorethamine toward both murine bone marrow progenitor cells and L1210 leukemia cells. Choline protected cells against nitrogen mustard cytotoxicity, but increased their sensitivity toward ethanol mustard. 2-(di-n--butylamino)ethanol was the best protector of both bone marrow precursor cells and L1210 cells against ethanol mustard cytotoxicity. Both ethanol mustard and 2-(di-n-butylamino)ethanol showed non-competitive inhibition of choline transport.

Animals↗

Combined enzymic-Jaffé method for determination of creatinine in serum.

Concentrations of creatinine, as determined in serum by a method involving the combined use of creatinine amidohydrolase (EC 3.5.2.10) and alkaline sodium picrate were found to be factitiously low, owing to a reversal of the enzyme reaction. This effect could be eliminated by converting creatine, the product of the enzymic reaction, to creatine phosphate. The combined enzymic-Jaffé method was therefore modified to include creatine amidohydrolase, creatine kinase, ATP, and Mg2+ in the reaction mixture. The modified method has good precision. We saw no significant interferences by relatively high concentrations of acetone, acetylacetone, ADP, creatine, creatine phosphate, glucose, glycocyamine, or pyruvate. Likewise, no interferences were evident with icteric, lipemic, or hemolytic serum samples. There was an excellent agreement between creatinine values obtained with our method and by a reference method based on isotope dilution-mass fragmentography. Our method is considerably simpler than the fully enzymic method for determination of creatinine and might be a method of choice if a high accuracy is desired.

Adenosine Triphosphate↗

Identification of interstitial cells of Cajal. Significance for studies of human small intestine and colon.

BACKGROUND: Interstitial cells of Cajal (ICC) were described a century ago by Ramón y Cajal a.o. as primitive neurons in the intestines. In the period 1900-1960 a large number of light microscopical studies of ICC were published, in which ICC were identified by heir characteristic morphology. After 1960 electron microscopical studies emphasized similarities between ICC and fibroblasts. In our early studies of ICC in the external musculature of mouse small intestine, we identified ICC by their characteristic morphology and topography, and we analyzed the relation between ICC, autonomic nerves and smooth muscle. These studies strongly suggested that ICC were fundamental regulators of external muscle function. These hypotheses have since been supported by independent morphological and electrophysiological evidence, strongly suggesting a pacemaker role of some ICC populations as well as other regulatory functions (mechanoreceptive, mediating inhibitory nervous input). In spite of this possible fundamental importance for G-I motility, ICC have not been adequately described or even identified in human intestine, and hence, never included in ultrastructural studies of G-I neuropathology. This survey presents the concepts of ultrastructure necessary for identification and morphological studies of ICC in human intestine. METHODOLOGY: Several light microscopical methods have been claimed selective for intestinal ICC (and nerves), including vital methylene blue, Golgi methods, silver impregnations and ZIO-methods. Unfortunately, even the most reliable of them (ZIO, vital methylene blue) do not work at all in some animal species and in some, regions of the intestinal wall. In our hands, the best results have been obtained in mouse small intestine with vital methylene blue staining (AP only) and with ZIO methods (all levels of the musculature). None of them have yet proved their value in human intestine, although we have occasionally stained ICC-SMP in human colon with ZIO methods. Optimal ultrastructural preservation of ICC for TEM studies in laboratory animals, has been achieved by fixation by vascular perfusion. In humans, the ultrastructural preservation was satisfactory, but not ideal, after optimizing the immersion fixatives (Karnovsky-types, addition of picrate). RESULTS AND DISCUSSION: General architecture of musculature externa. ICC differ markedly in their organization and ultrastructure from one part of the gut and from one region to another. For understanding the extent and distribution of ICC plexuses it is therefore critical to preserve a stringency and uniformity with respect to terminologies and descriptions of topography. Auerbach's plexus (AP) designates the ganglionated plexus between the main muscle layers in small and large intestine, whereas we prefer to use the term myenteric plexus for all nerves in the external muscle. The deep muscular plexus (DMP) designates the two-dimensional, non-ganglionated nerve plexus between the thick outer and thin inner subdivision of the circular muscle layer in the small intestine. In our material a similar plexus was not present in colon. The submuscular plexus (SMP) indicates the non-ganglionated, two-dimensional nerve plexus present at the submucosal surface of the colonic circular muscle. The circular muscle in small- and large intestine of large animals (dogs, humans) is organized into lamellae, separated by main septa piercing the whole layer. Both in the small intestine and colon the innermost circular muscle cells, are smaller, and, particularly in colon, more irregular than the bulk of the circular muscle. Identification of ICC in laboratory animals. By TEM ICC are distinguishable as a separate cell type in the small- and large intestine of all species investigated.(ABSTRACT TRUNCATED)

Animals↗