PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “WASTES”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15Linked to original sources

[Waste management strategy and the role of the environmental protection and energy efficiency fund].

On 14 October 2005, the Croatian Parliament adopted the National Strategy of Waste Management pursuant to Article 8 of the Waste Act. This strategy defines its objectives and the means to reach them, and gives an overview of the current situation in waste management. It seeks to provide a realistic framework for the effective reduction of national waste load and for a sustainable waste management. This Strategy defines 15 major waste flows which are in concordance with the EU practice. It also defines waste management buildings and plants, and looks into the remediation of municipal waste landfills. According to the Strategy, waste management will be present on all levels of administration: from national to local, and will include all areas of production, consumption, and everyday life. Founded on the EU's general principles of waste management, this Strategy provides the ideal framework for a sustained waste management in Croatia by the year 2025. Environmental Protection and Energy Efficiency Fund is one of the key administration bodies within the waste management system. It collects taxes for motor vehicles, for sulphur and nitrogen oxide pollution sources, for environmental hazardous and non-hazardous industrial waste load, and for the use of the environment. The Fund participates in the ongoing municipal landfill remediation projects and programmes all over Croatia (currently 161 landfills are being remedied) and helps to establish new regional and county waste management centres. It co-finances clean production technology projects, projects whose aim is to reduce the emission of harmful gases, projects for reusable energy sources and for more efficient use of energy, projects for remediation of unregulated municipal landfills, projects for primary recycling, and projects for biodiversity landscapes. According to an estimate, the implementation of the National Strategy of Waste Management will cost over 24 billion Croatian kunas (about 3.3 billion Euros). Beside national and local revenues, the Fund will play a key role in carrying this burden.

Croatia↗

Medical waste management in Korea.

The management of medical waste is of great importance due to its potential environmental hazards and public health risks. In the past medical waste was often mixed with municipal solid waste and disposed of in residential waste landfills or improper treatment facilities (e.g. inadequately controlled incinerators) in Korea. In recent years, many efforts have been made by environmental regulatory agencies and waste generators to better manage the waste from healthcare facilities. This paper presents an overview of the current management practices of medical waste in Korea. Information regarding generation, composition, segregation, transportation, and disposal of medical wastes is provided and discussed. Medical waste incineration is identified as the most preferred disposal method and will be the only available treatment option in late 2005. Faced with increased regulations over toxic air emissions (e.g. dioxins and furans), all existing small incineration facilities that do not have air pollution control devices will cease operation in the next few years. Large-scale medical waste incinerators would be responsible for the treatment of medical waste generated by most healthcare facilities in Korea. It is important to point out that there is a great potential to emit air toxic pollutants from such incinerators if improperly operated and managed, because medical waste typically contains a variety of plastic materials such as polyvinyl chloride (PVC). Waste minimization and recycling, control of toxic air emissions at medical waste incinerators, and alternative treatment methods to incineration are regarded to be the major challenges in the future.

Air Pollutants↗

A study of the dental solid waste produced in a school of dentistry in Turkey.

Dental wastes are regulated under medical waste control regulations in most countries. Even though the quantity of hazardous wastes in dental solid wastes is a small proportion, there is still cross infection risk and potential danger for environment associated with mismanaged wastes. For this reason, knowledge of waste composition and development of proper management alternatives are necessary. In this study, the composition of solid wastes coming from eight clinics of the dental school of a University hospital in Turkey is examined. Although the waste has some variations between the two samplings, the general picture is such that the major components remain pretty much the same (in terms of %) for a fixed clinic. The composition of waste changes from one clinic to the other as expected. However, one can deduce from the data obtained that at about 35%, rubber gloves constitute close to the half of the total solid waste in almost all the clinics. Other major component is paper forming approximately 30% of the solid waste. In general, total waste coming from the clinics is related with the number of procedures conducted on patients at the clinics. Only a small fraction of the waste is hazardous indicating that at Hacettepe University School of Dentistry, hazardous waste collection rules are obeyed in most of the times.

Dental Waste↗

Biomedical waste in laboratory medicine: audit and management.

Pathology, microbiology, blood bank and other diagnostic laboratories generate sizable amount of biomedical waste (BMW). The audit of the BMW is required for planning proper strategies. The audit in our laboratory revealed 8 kgs anatomical waste, 600 kgs microbiology waste, 220 kgs waste sharps, 15 kgs soiled waste, 111 kgs solid waste, 480 litres liquid waste along with 33,000 litres per month liquid waste generated from labware washing and laboratory cleaning and 162 litres of chemical waste per month. Section wise details are described in the text. Needle sharps are collected in puncture proof containers and the needles autoclaved before sending to needle pit. The glass forms the major sharp category and is disinfected with hypochlorite before washing/recycling. All microbiology waste along with containers/plates/tubes are autoclaved before recycling/disposal. The problem of formalin fixed anatomical waste as histology specimens is pointed out. The formalin containing tissues cannot be sent for incineration for the fear of toxic gas release and the guidelines by the Biomedical waste rule makers need to be amended for the issue. The discarded/infected blood units in blood bank need to be autoclaved before disposal since chemical treatments are difficult or inefficient. The liquid waste management needs more attention and effluent treatment facility needs to be viewed seriously for hospital in general. The segregation of waste at source is the key step and reduction, reuse and recycling should be considered in proper perspectives.

Hospitals↗

Management of infectious waste by US hospitals.

In July 1987 and January 1988, forty-six percent (441/955) of randomly selected US hospitals responded to a questionnaire intended to identify their waste disposal practices. Survey responses were received from hospitals in 48 states. United States hospitals generated a median of 6.93 kg of hospital waste per patient per day and infectious waste made up 15% of the total hospital waste. Most hospitals (greater than 90%) considered blood, microbiology, "sharps," communicable disease isolation, pathology, autopsy, and contaminated animal carcass waste as infectious. Other sources of hospital waste that were commonly (greater than 80%) designated infectious were surgical, dialysis, and miscellaneous laboratory waste. The infectious waste was normally (80%) treated via incineration or steam sterilization before disposal, whereas noninfectious waste was discarded directly in a sanitary landfill. Eight-two percent of these US hospitals are discarding blood, microbiology, sharps, pathology, and contaminated animal carcass waste in accordance with the Centers for Disease Control's recommendations, while the compliance rate for the Environmental Protection Agency's recommendations (excluding optional waste) is 75%. No hospital could identify an infection problem (excluding needle-stick injuries) that was attributable to the disposal of infectious waste. While the management of infectious waste by US hospitals is generally consistent with the Centers for Disease Control's guidelines, many hospitals employ overly inclusive definitions of infectious waste.

Centers for Disease Control and Prevention, U.S.↗

Warren K. Sinclair keynote address: contemporary issues in risk-informed decision making on the disposition of radioactive waste.

A consistent and transparent risk-informed approach to managing nuclear waste is plagued with different regulators, different rules and regulations for different waste types, different compliance requirements, and indecisions about probabilistic vs. deterministic models. Low-activity waste management is particularly void of a path forward with respect to being risk-informed. Risk assessment is not referenced in the statutes on low-activity waste even though both the U.S. Environmental Protection Agency and U.S. Nuclear Regulatory Commission (U.S. NRC) have policies to apply consistent risk management approaches to all of their programs. The U.S. NRC has developed guidance on the preparation of probabilistic performance assessments for low-activity waste facilities, but there have been no serious takers and a lack of initiative on the part of licensees. Thus, little to no experience exists on risk-informing low-activity waste. The missed opportunities include establishing a risk basis that would allow for simpler, safer, and much less costly alternatives for low-activity waste disposal while enabling society to have the full benefit of radiation technologies. There is hope that congressional action or regulatory rule making will address some of these issues with the result being the adoption of a more general and unified approach to risk-informed regulation of all types of waste. Just as much of the initiative for risk-informed nuclear power came from industry, it must also be the case for nuclear waste. A start would be the adoption of a basic framework of risk assessment in waste management applicable to all types of waste--radioactive and nonradioactive. The "set of triplets" risk assessment framework that is applicable to any kind of risk is an established alternative. It is believed that such a framework with the support of a regulatory structure made compatible through appropriate rulemaking or congressional action, and the experience of the probabilistic performance assessments for the Waste Isolation Pilot Plant and the proposed Yucca Mountain high-level waste repository, could result in the right path forward for the regulation and management of low-activity waste.

Decision Making↗

Revolutionary advances in medical waste management. The Sanitec system.

It is the purpose of this collective review to provide a detailed outline of a revolutionary medical waste disposal system that should be used in all medical centers in the world to prevent pollution of our planet from medical waste. The Sanitec medical waste disposal system consists of the following seven components: (1) an all-weather steel enclosure of the waste management system, allowing it to be used inside or outside of the hospital center; (2) an automatic mechanical lift-and-load system that protects the workers from devastating back injuries; (3) a sophisticated shredding system designed for medical waste; (4) a series of air filters including the High Efficiency Particulate Air (HEPA) filter; (5) microwave disinfection of the medical waste material; (6) a waste compactor or dumpster; and (7) an onboard microprocessor. It must be emphasized that this waste management system can be used either inside or outside the hospital. From start to finish, the Sanitec Microwave Disinfection system is designed to provide process and engineering controls that assure complete disinfection and destruction, while minimizing the operator's exposure to risk. There are numerous technologic benefits to the Sanitec systems, including environmental, operational, physical, and disinfection efficiency as well as waste residue disinfection. Wastes treated through the Sanitec system are thoroughly disinfected, unrecognizable, and reduced in volume by approximately 80% (saving valuable landfill space and reducing hauling requirements and costs). They are acceptable in any municipal solid waste program. Sanitec's Zero Pollution Advantage is augmented by a complete range of services, including installation, startup, testing, training, maintenance, and repair, over the life of this system. The Sanitec waste management system has essentially been designed to provide the best overall solution to the customer, when that customer actually looks at the total cost of dealing with the medical waste issue. The Sanitec system is the right choice for healthcare and medical waste professionals around the world.

Equipment Design↗

Hospital waste management in the teaching hospitals of Karachi.

OBJECTIVE: To evaluate the current practices of segregation approaches, storage arrangements, collection and disposal systems in the teaching hospitals of Karachi. METHODS: A cross-sectional survey was conducted in eight teaching hospitals of Karachi, using convenient sampling technique. The instrument of research was a self administered questionnaire, with four sections, relating to the general information of the institution, administrative information, information regarding Health Waste Management personnel and a check-list of Hospital Waste Management activities. RESULTS: Out of eight hospitals visited 2 (25%) were segregating sharps, pathological waste, chemical, infectious, pharmaceutical and pressurized containers at source. For handling potentially dangerous waste, two (25%) hospitals provided essential protective gears to its waste handlers. Only one (12.5%) hospital arranged training sessions for its waste handling staff regularly. Five (62.5%) hospitals had storage areas but mostly it was not protected from access of scavengers. Five (62.5%) hospitals disposed off their hazardous waste by burning in incinerators, two (25%) disposed off by municipal landfills and one (12.5%) was burning waste in open air without any specific treatment. No record of waste was generally maintained. Only two (25%) hospitals had well documented guidelines for waste management and a proper waste management team. CONCLUSION: There should be proper training and management regarding awareness and practices of waste disposal. Research must be undertaken to seal existing gaps in the knowledge about hospital waste management. The hospital waste management guidelines enacted on 7th June 2004 should be followed and regulated by law enforcement agencies rigorously.

Awareness↗

Collection of domestic waste. Review of occupational health problems and their possible causes.

During the last decade, a growing interest in recycling of domestic waste has emerged, and action plans to increase the recycling of domestic waste have been agreed by many governments. A common feature of these plans is the implementation of new systems and equipment for the collection of domestic waste which has been separated at source. However, only limited information exists on possible occupational health problems related to such new systems. Occupational accidents are very frequent among waste collectors. Based on current knowledge, it appears that the risk factors should be considered as an integrated entity, i.e. technical factors (poor accessibility to the waste, design of equipment) may act in concert with high working rate, visual fatigue due to poor illumination and perhaps muscle fatigue due to high work load. Musculoskeletal problems are also common among waste collectors. A good deal of knowledge has accumulated on mechanical load on the spine and energetic load on the cardio-pulmonary system in relation to the handling of waste bags, bins, domestic containers and large containers. However, epidemiologic studies with exposure classification based on field measurement are needed, both to further identify high risk work conditions and to provide a detailed basis for the establishment of occupational exposure limits for mechanical and energetic load particularly in relation to pulling, pushing and tilting of containers. In 1975, an excess risk for chronic bronchitis was reported for waste collectors in Geneva (Rufèner-Press et al., 1975) and data from the Danish Registry of Occupational Accidents and Diseases also indicate an excess risk for pulmonary problems among waste collectors compared with the total work force. Surprisingly few measurements of potentially hazardous airborne exposures have been performed, and the causality of work-related pulmonary problems among waste collectors is unknown. Recent studies have indicated that implementation of some new waste collection systems may result in an increased risk of occupational health problems. High incidence rates of gastrointestinal problems, irritation of the eye and skin, and perhaps symptoms of organic dust toxic syndrome (influenza-like symptoms, cough, muscle pains, fever, fatigue, headache) have been reported among workers collecting the biodegradable fraction of domestic waste. The few data available on exposure to bio-aerosols and volatile compounds have indicated that these waste collectors may be simultaneously exposed to multiple agents such as dust containing bacteria, endotoxin, mould spores, glucans, volatile organic compounds, and diesel exhaust. Several studies have reported similar health problems as well as high incidence rates of pulmonary disease among workers at plants recycling domestic waste.(ABSTRACT TRUNCATED AT 400 WORDS)

Accidents, Occupational↗

Comparison of waste composition in a continuing-care retirement community.

OBJECTIVE: To determine the composition of wastes generated in a continuing-care retirement community (CCRC) and to analyze the effects of source-reduction activities and meal delivery system change on the amount of waste generated in the facility. DESIGN: A waste stream analysis was conducted at the same CCRC during spring 1994 (period 1: baseline), spring 1995 (period 2: source reduction intervention), and fall 1995 (period 3: service delivery intervention). Weight, volume, and collapsed volume were determined for food and packaging wastes. SETTING: Tray service and wait staff service are provided to 70 residents in a health care unit, and family-style service is an optional service available to 130 residents in the independent-living units. A mean of 229 meals are served per day. INTERVENTION: Intervention included the implementation of source-reduction activities and a change in a service-delivery system in periods 2 and 3, respectively. STATISTICAL ANALYSIS PERFORMED: Descriptive statistics were used to determine the composition of waste. Analysis of variance and a multiple comparison method (least significant difference) were used to compare mean weight and volume of waste generated in period 1 with data collected during periods 2 and 3. RESULTS: Mean waste generated per meal by weight and volume ranged from 0.93 to 1.00 lb and 1.44 to 1.65 gal, respectively. Significantly less production waste by weight (0.18 lb/meal) and volume (0.12 gal/meal) was generated in period 2 than in period 1 (0.32 lb/meal and 0.16 gal/meal, respectively). Significantly less service waste by weight (0.31 lb/meal) and volume (0.05 gal/meal) was discarded in period 3 than in period 1 (0.37 lb/meal and 0.15 gal/meal, respectively). Significantly less total waste and plastic by weight was disposed of after the interventions. The study conclusions indicated that implementing source-reduction practices and changing the meal-delivery system affected the composition of waste generated. APPLICATIONS: Knowledge of waste stream composition can help other foodservice professionals and consulting dietitians identify waste-reduction activities and recycling opportunities. The quantity and type of waste generated should be considered when operational decisions are made relative to market form of food, menu choices, service-delivery systems, and production forecast and controls.

Activities of Daily Living↗

Medical waste treatment and disposal methods used by hospitals in Oregon, Washington, and Idaho.

This study investigated medical waste practices used by hospitals in Oregon, Washington, and Idaho, which includes the majority of hospitals in the U.S. Environmental Protection Agency's (EPA) Region 10. During the fall of 1993, 225 hospitals were surveyed with a response rate of 72.5%. The results reported here focus on infectious waste segregation practices, medical waste treatment and disposal practices, and the operating status of hospital incinerators in these three states. Hospitals were provided a definition of medical waste in the survey, but were queried about how they define infectious waste. The results implied that there was no consensus about which agency or organization's definition of infectious waste should be used in their waste management programs. Confusion around the definition of infectious waste may also have contributed to the finding that almost half of the hospitals are not segregating infectious waste from other medical waste. The most frequently used practice of treating and disposing of medical waste was the use of private haulers that transport medical waste to treatment facilities (61.5%). The next most frequently reported techniques were pouring into municipal sewage (46.6%), depositing in landfills (41.6%), and autoclaving (32.3%). Other methods adopted by hospitals included Electro-Thermal-Deactivation (ETD), hydropulping, microwaving, and grinding before pouring into the municipal sewer. Hospitals were asked to identify all methods they used in the treatment and disposal of medical waste. Percentages, therefore, add up to greater than 100% because the majority chose more than one method. Hospitals in Oregon and Washington used microwaving and ETD methods to treat medical waste, while those in Idaho did not. No hospitals in any of the states reported using irradiation as a treatment technique. Most hospitals in Oregon and Washington no longer operate their incinerators due to more stringent regulations regarding air pollution emissions. Hospitals in Idaho, however, were still operating incinerators in the absence of state regulations specific to these types of facilities.

Idaho↗

Consumption and production waste: another externality of tobacco use.

OBJECTIVE: To describe the waste produced by and environmental implications of individual cigarette consumption (filter tips, packages, and cartons) and tobacco manufacturing. STUDY SELECTION: All available articles and reports published since 1970 related to cigarette consumption and production waste were reviewed. DATA SOURCES: Global cigarette consumption data were used to estimate cigarette butt and packaging waste quantities. Data from the Center for Marine Conservation's International Coastal Cleanup Project were used to describe some environmental impacts of tobacco-related trash. Data from the United States Environmental Protection Agency's (EPA's) Toxics Release Inventory and reported global cigarette consumption totals were used to estimate waste production from cigarette manufacturing. DATA EXTRACTION AND SYNTHESIS: In 1995, an estimated 5.535 trillion cigarettes (27,675 million cartons and 276,753 million packages) were sold by the tobacco industry globally. Some of the wastes from these products were properly deposited, but a large amount of tobacco consumption waste ends up in the environment. Some is recovered during environmental clean-up days. For the past eight years (1990-1997), cigarette butts have been the leading item found during the International Coastal Cleanup Project; they accounted for 19.1% of all items collected in 1997. The tobacco manufacturing process produces liquid, solid, and airborne waste. Among those wastes, some materials, including nicotine, are designated by the EPA as Toxics Release Inventory (TRI) chemicals. These are possible environmental health hazards. In 1995, the global tobacco industry produced an estimated 2262 million kilograms of manufacturing waste and 209 million kilograms of chemical waste. In addition, total nicotine waste produced in the manufacture of reduced nicotine cigarettes was estimated at 300 million kilograms. CONCLUSIONS: Laws against littering relative to cigarette butts could be better enforced. Additional taxes might be levied on cigarette products that would then be directed to environmental clean-up efforts. The tobacco industry should improve the biodegradability of filters, reduce packaging waste, and educate its customers. Worksites and public buildings should be encouraged or required to supply appropriate disposal mechanisms at all building entrances. Public awareness campaigns about the magnitude and prevention of cigarette consumption waste could be developed through partnerships among environmental groups, health organisations, and environmental protection agencies. Tobacco production waste should be a source of concern and regulation by governments throughout the world; it contains numerous chemicals which may be considered health hazards, not the least of which is nicotine produced in the manufacture of low-nicotine cigarettes.

Environmental Monitoring↗

Waste benefits of CO2 policies in Japan.

A linear programming model REAP (Regional Environmental strategy Analysis Program) has been developed for the analysis of the consequences of a CO2 tax for petrochemical products such as plastics (CO2, carbon dioxide, is the most important greenhouse gas). Special attention has been paid to the impacts on waste management. The results suggest that a 10,000 Y t(-1) CO2 tax would result in a significant reduction of CO2 emissions in the petrochemical life cycle, ranging from 40 Mt in 2015 to 70 Mt CO2 in later decades (more than 50% emission reduction). Waste quantities will be reduced simultaneously. The CO2 tax results in an 18% reduction of plastic waste weight in 2015 (3 Mt waste). Lower tax levels that may be politically more acceptable would result in proportionally lower environmental benefits. CO2 benefits and waste benefits of a CO2 tax are of equal importance in policy terms. Apart from changes in waste volume, CO2 taxes would affect the cost-effectiveness of waste handling technologies. Energy recovery in industrial kilns may replace conventional waste incineration. Recycling constitutes half of the total waste treatment. Given these results, current investments in new incineration capacity may suffer from insufficient waste availability during the next two decades in case CO2 taxes are introduced. A third effect of a CO2 tax is a significant increase of waste transportation. The results show that this increase is concentrated in the central part of Honshu (Kinki, Chubu & Kanto). Such transportation can result in new local environmental impacts that should be analysed in more detail. Given the strong impact of CO2 taxes on waste quantities and waste treatment it is recommended to co-ordinate CO2 policies and solid waste policies.

Carbon Dioxide↗

Hospital waste management and toxicity evaluation: a case study.

Hospital waste management is an imperative environmental and public safety issue, due to the waste's infectious and hazardous character. This paper examines the existing waste strategy of a typical hospital in Greece with a bed capacity of 400-600. The segregation, collection, packaging, storage, transportation and disposal of waste were monitored and the observed problematic areas documented. The concentrations of BOD, COD and heavy metals were measured in the wastewater the hospital generated. The wastewater's toxicity was also investigated. During the study, omissions and negligence were observed at every stage of the waste management system, particularly with regard to the treatment of infectious waste. Inappropriate collection and transportation procedures for infectious waste, which jeopardized the safety of staff and patients, were recorded. However, inappropriate segregation practices were the dominant problem, which led to increased quantities of generated infectious waste and hence higher costs for their disposal. Infectious waste production was estimated using two different methods: one by weighing the incinerated waste (880 kg day(-1)) and the other by estimating the number of waste bags produced each day (650 kg day(-1)). Furthermore, measurements of the EC(50) parameter in wastewater samples revealed an increased toxicity in all samples. In addition, hazardous organic compounds were detected in wastewater samples using a gas chromatograph/mass spectrograph. Proposals recommending the application of a comprehensive hospital waste management system are presented that will ensure that any potential risks hospital wastes pose to public health and to the environment are minimized.

Aliivibrio fischeri↗

Evaluation of fruit-vegetable and fish wastes as alternative feedstuffs in pig diets.

Fruit-vegetable and fish wastes were evaluated as potential feedstuffs for growing-finishing pigs. Wastes were collected from shops in the city of Salamanca (Spain) and their nutritional composition, mineral content and digestibility were determined. The dry matter of the wastes under study was relatively low (12% for fruit-vegetable waste and 26% for fish waste), but they presented all of the nutrient requirements for swine diets. The fish waste contained 58% crude protein, 22% ash, 19% ether extract and 1% crude fibre, whereas the fruit-vegetable waste contained 65% nitrogen free extract, 13% crude fibre, 12% crude protein, 8% ash and 2% ether extract. Waste digestibility decreased with temperature, and hence temperatures over 65 degrees C for fruit-vegetable waste and 105 degrees C for fish waste should not be used in the treatment to reduce the moisture and to ensure the microbiology quality. Therefore, two diets were formulated using linear programming. The analysed waste was included in approximately 20% of one of the diets, while another diet was formulated without any type of waste. These data showed that this part of biodegradable municipal waste could be managed as alternative feedstuffs in swine diets, reducing the amount of biodegradable municipal waste going to landfills.

Animal Feed↗

Environmental and health impacts of household solid waste handling and disposal practices in third world cities: the case of the Accra Metropolitan Area, Ghana.

Inadequate provision of solid waste management facilities in Third World cities results in indiscriminate disposal and unsanitary environments, which threatens the health of urban residents. The study reported here examined household-level waste management and disposal practices in the Accra Metropolitan Area, Ghana. The residents of Accra currently generate large amounts of solid waste, beyond the management capabilities of the existing waste management system. Because the solid waste infrastructure is inadequate, over 80 percent of the population do not have home collection services. Only 13.5 percent of respondents are served with door-to-door collection of solid waste, while the rest dispose of their waste at communal collection points, in open spaces, and in waterways. The majority of households store their waste in open containers and plastic bags in the home. Waste storage in the home is associated with the presence of houseflies in the kitchen (r = .17, p < .0001). The presence of houseflies in the kitchen during cooking is correlated with the incidence of childhood diarrhea (r = .36, p < .0001). Inadequate solid waste facilities result in indiscriminate burning and burying of solid waste. There is an association between waste burning and the incidence of respiratory health symptoms among adults (r = .25, p < .0001) and children (r = .22, p < .05). Poor handling and disposal of waste are major causes of environmental pollution, which creates breeding grounds for pathogenic organisms, and the spread of infectious diseases. Improving access to solid waste collection facilities and services will help achieve sound environmental health in Accra.

Animals↗

Current legislation governing clinical waste disposal.

The paper considers UK and EC Legislation regulating clinical waste disposal. The legal definition of clinical waste is distinguished from both 'health care waste' and 'infectious waste'. Waste can be pre-treated so as to enable it to be disposed of through the normal waste stream. The legislation is looked at by reference to (i) production and storage; (ii) handling and transportation; and (iii) disposal. It is vitally important to draw up a waste management strategy. Effective segregation at source is a key factor in the waste management strategy and it will enable hospital authorities to make economic savings in waste disposal costs. The Paper considers the Duty of Care under the Environmental Protection Act 1990 and stresses the obligation on each person in the waste disposal chain to discharge the Duty. Landfilling as a method of disposal is discouraged except for waste where no possibility of infection arises. There are problems with hospital incinerators meeting modern emission standards. Requirements for licensing new incinerators are examined. The new Waste Management Licensing Regulations 1994 require applications for Waste Management Licenses to demonstrate technical and financial competence as 'fit and proper persons'. The Paper concludes by examining penalties for breach of regulatory provisions.

England↗

Radioactive waste disposal implications of extending Part IIA of the Environmental Protection Act to cover radioactively contaminated land.

A short study has been carried out of the potential radioactive waste disposal issues associated with the proposed extension of Part IIA of the Environmental Protection Act 1990 to include radioactively contaminated land, where there is no other suitable existing legislation. It was found that there is likely to be an availability problem with respect to disposal at landfills of the radioactive wastes arising from remediation. This is expected to be principally wastes of high volume and low activity (categorised as low level waste (LLW) and very low level waste (VLLW)). The availability problem results from a lack of applications by landfill operators for authorisation to accept LLW wastes for disposal. This is apparently due to perceived adverse publicity associated with the consultation process for authorisation coupled with uncertainty over future liabilities. Disposal of waste as VLLW is limited both by questions over volumes that may be acceptable and, more fundamentally, by the likely alpha activity of wastes (originating from radium and thorium operations). Authorised on-site disposal has had little attention in policy and guidance in recent years, but may have a part to play, especially if considered commercially attractive. Disposal at BNFL's near surface disposal facility for LLW at Drigg is limited to wastes for which there are no practical alternative disposal options (and preference has been given to operational type wastes). Therefore, wastes from the radioactively contaminated land (RCL) regime are not obviously attractive for disposal to Drigg. Illustrative calculations have been performed based on possible volumes and activities of RCL arisings (and assuming Drigg's future volumetric disposal capacity is 950,000 m3). These suggest that wastes arising from implementing the RCL regime, if all disposed to Drigg, would not represent a significant fraction of the volumetric capacity of Drigg, but could have a significant impact on the radiological capacity with respect to 226Ra plus 232Th. The government's decision-making programme for managing solid radioactive wastes in the UK may possibly achieve a general consensus that the use of landfill for LLW from the RCL regime has a fundamental role to play. However, this is unlikely to change the situation within the next few years. No new national facility arising from this programme is likely to be available during the first decade of the operation of a new RCL regime. Hence it appears that Drigg will need to play an important role for some years to come.

Humans↗