PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “parameter optimization”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15Linked to original sources

Spatial and temporal matching of receptive field properties of binocular cells in area 19 of the cat.

The spatial and temporal properties of single neurons were investigated in area 19 of the cat. We evaluated the matching of binocular receptive field properties with regard to the respective strength of the ipsilateral and contralateral inputs. Results indicate that most cells in area 19 are well tuned to spatial and temporal frequencies and exhibit relatively low contrast threshold (mean=6.8%) when assessed using optimal parameters and tested through the dominant eye. Spatial resolution (mean=0.75 c/degree), optimal spatial frequencies (mean=0.16 c/degree) were relatively low and spatial bandwidths (mean=2.1 octaves) were broader as compared to those of cells in area 17 but comparable to those of cells in other extrastriate areas. On the other hand temporal resolution (mean=10.7 Hz), optimal temporal frequency (mean=4.5 Hz) and temporal bandwidths (mean=2.9 octaves) were higher and broader than in primary visual cortex. A significant relationship exists between most of the cell's properties assessed through either eye. For some parameters, such as spatial and temporal resolution, ocular dominance was shown to be significantly related to the extent of matching between the two eyes. For these parameters, binocular cells that exhibited a balanced ocular dominance were generally well matched with regard to the receptive field properties of each eye whereas the largest mismatches were found in cells that were more strongly dominated by one eye. These results suggest that visual input contributes to the activation of cells in area 19 in a redundant manner, possibly attesting to the multiplicity of parallel pathways to this area in the cat.

Animals↗

[Effect of the conditions of isolation of free and bound ligands on the accuracy of the radioimmunoassay of steroids].

Testosterone radioimmunoassay (RIA) was used to analyse the factors which influenced the precision and accuracy of steroid RIA. Selection of optimal parameters (concentrations of activated charcoal and of the radioactive steroid) was necessary in order to reduce the influence of non-specific binding and error of fractionation on the RIA results. The scheme for estimation of the optimal values of these parameters is described.

Charcoal↗

Studies on the feasibility of urinary bladder evacuation by direct spinal cord stimulation. I. Parameters of most effective stimulation.

In 30 female dogs, spinal cord stimulation was tested to find the optimal parameters producing good voiding and, hopefully, total bladder emptying. Twelve different electrodes or application modifications were examined. Variable frequencies, stimulus duration, and voltages were applied. Search of the site of highest detrusor response (micturition center) was easily identifiable. It became obvious that electrode design was not of critical importance: the responses were basically the same whether we used the wrap-around electrode, which stimulates an entire level, or the coaxial electrode which theoretically limits the current spread around its minute exposed tip. The stimulation parameters that gave the best results were: 2 to 5 volts; frequency: 10 to 15 cps; duration 1 msec. The site of highest detrusor response was round vertebral level L5 1/2, corresponding to cord level S2-4. Generally, no voiding was obtained because of too high sphincteric contraction during stimulation; it appeared that a sphincteric center overlaps the micturition center in either direction. To achieve successful voiding during stimulation, a separation of these two centers with selective stimulation of the detrusor center is necessary, eleiminating sphincteric contraction.

Animals↗

Study of microencapsulation for pituitary transplantation: capsule preparation and in vitro study.

We have developed microcapsules using sodium alginate (SA) and Poly-L-Lysine (PLL). A factorial design method of screening was chosen to study influences of different experimental parameters on size and stability of the capsules. We found that air flow affects initial size of the capsules significantly, while the molecular weight (MW) of PLL and incubation time have a positive impact on the expansion when capsules are incubated in sodium citrate (SC). When the capsules were continuously shaken in an attempt to mimic in vivo environmental conditions, those capsules made with optimal parameters (0.1% PLL, 42,000 MW, incubated for 6 minutes; 1.5% SA, incubated for 4 minutes; SC bath 4 minutes; 25# needle; air flow 14L/min) were still intact after 30 days and not totally ruptured until 90 days, while those developed with less strict parameters were ruptured within 2 hours in 50%. We also encapsulated human pituitary adenoma cells using PLL of 80,000 MW and cultured them for 9 days. Adenoma cells, both encapsulated or non-encapsulated, secreted the same amount of hormones. Our preliminary study suggests that selecting optimal combinations of experimental parameters is essential in developing durable microcapsules, which may be potentially used for pituitary transplantation in vivo.

Adenoma↗

Multicomponent analysis of volatile organic compounds in water by automated purge and trap coupled to gas chromatography-mass spectrometry.

The performance of an automated purge and trap concentrator coupled to gas chromatography-mass spectrometric detection was evaluated by analyzing 40 volatile organic compounds of different chemical families. Compounds chosen defined as toxic for the environment and for human health were selected according to Directive 76/464/CEE. The present work includes: (i) the optimization of the purge and trap conditions, (ii) the establishment of quality parameters and in last instance (iii) the analysis of surface waters. The analytical method consisted of a modification of the EPA Method 524.2 in which water was pumped, via an automated AquaTek 70 Liquid Autosampler to a 25-ml purging device, where samples were purged and trapped in a Tenax or Tenax-Silica and Charcoal column. Afterwards, helium was used to desorb the trapped analytes that flow directly into the GC column. Mass spectrometric analysis was carried out in selected ion monitoring and scan modes to ensure quantification and confirmation of the results. Parameters optimized were the sample volume analyzed, bubbling flow-rate and time and temperature of desorption. Optimal conditions lead to mean recoveries of 80%, limits of detection between 0.002 and 0.1 microg/l, linearity from 0.01 to 2.5 microg/l and maximum standard deviation of 10%, using a Tenax trap. This protocol permitted a high precision and sample throughput and was used to determine volatile organic compounds in surface river, effluents and coastal waters of Portugal, on a routine basis.

Calibration↗

An automated form of video image analysis applied to classification of movement disorders.

Video image analysis is able to provide quantitative data on postural and movement abnormalities and thus has an important application in neurological diagnosis and management. The conventional techniques require patients to be videotaped while wearing markers in a highly structured laboratory environment. This restricts the utility of video in routine clinical practise. We have begun development of intelligent software which aims to provide a more flexible system able to quantify human posture and movement directly from whole-body images without markers and in an unstructured environment. The steps involved are to extract complete human profiles from video frames, to fit skeletal frameworks to the profiles and derive joint angles and swing distances. By this means a given posture is reduced to a set of basic parameters that can provide input to a neural network classifier. To test the system's performance we videotaped patients with dopa-responsive Parkinsonism and age-matched normals during several gait cycles, to yield 61 patient and 49 normal postures. These postures were reduced to their basic parameters and fed to the neural network classifier in various combinations. The optimal parameter sets (consisting of both swing distances and joint angles) yielded successful classification of normals and patients with an accuracy above 90%. This result demonstrated the feasibility of the approach. The technique has the potential to guide clinicians on the relative sensitivity of specific postural/gait features in diagnosis. Future studies will aim to improve the robustness of the system in providing accurate parameter estimates from subjects wearing a range of clothing, and to further improve discrimination by incorporating more stages of the gait cycle into the analysis.

Algorithms↗

Parameter estimation by reduced-order linear associative memory (ROLAM).

In a series of papers we have shown that nonlinear parameter estimation by linear association provides accurate estimates of the parameters in complex systems described by nonlinear differential equations even in the presence of additive white noise of considerable power. The technique is based on linearly associating the system's output with a set of parameter values spanning the region of interest. When an actual output is measured, the system's unknown parameters could be estimated by a matrix inversion. The size of the inverted matrix, being equal to the length of the output vector, poses a limiting factor upon the generalization of the technique. In this paper we propose a modification which requires the inversion of a matrix whose dimension equals the number of model parameters. The modified version is called reduced-order associative memory (ROLAM). The technique is applied to two complex lumped-parameter nonlinear models: the Van der Pol relaxation oscillator and the passive neuron model of the granule cells. Results validate ROLAM as a parameter-estimation tool which is especially suited in cases where the number of parameters is large, the number of samples in the observation signal is high, or when on-line parameter estimation is required. It is also shown that ROLAM provides an optimal parameter estimate in the special case of single-parameter nonlinear models.

Algorithms↗

Plate equations for piezoelectrically actuated flexural mode ultrasound transducers.

This paper considers variational methods to derive two-dimensional plate equations for piezoelectrically actuated flexural mode ultrasound transducers. In the absence of analytical expressions for the equivalent circuit parameters of a flexural mode transducer, it is difficult to calculate its optimal parameters and dimensions, and to choose suitable materials. The influence of coupling between flexural and extensional deformation, and coupling between the structure and the acoustic volume on the dynamic response of piezoelectrically actuated flexural mode transducer is analyzed using variational methods. Variational methods are applied to derive two-dimensional plate equations for the transducer, and to calculate the coupled electromechanical field variables. In these methods, the variations across the thickness direction vanish by using the stress resultants. Thus, two-dimensional plate equations for a stepwise laminated circular plate are obtained.

Journal Article↗

Long-term enhancement of CA1 synaptic transmission is due to increased quantal size, not quantal content.

Quantal components of Schaffer collateral synaptic transmission recorded intracellularly from CA1 pyramidal cells were examined using 2 methods: simultaneous recordings of CA3-CA1 cell-pairs, and minimal electrical stimulation in stratum radiatum. Quantal parameters estimated by the method of failures and by a computer algorithm that optimized parameter estimates using deconvolution of background noise were highly correlated. EPSP-amplitude histograms of CA3-CA1 cell pairs (N = 10) and minimal electrical stimulation (N = 33) could be adequately described either by Poisson or binomial statistics, or by both, and exhibited similar estimates of unit quantal size (q) and mean quantal content (m). Paired-pulse stimulation with 50 msec between stimuli resulted in an expected facilitation in the EPSP amplitude and increase in m during the second response, as estimated by noise deconvolution, by the decrease in apparent failures, and by a decrease in the coefficient of variation of the EPSP. Tetanization of the Schaffer collaterals that induced long-term enhancement (LTE/LTP) of the population response was associated with an average increase in q for minimal-stimulation responses, with no significant change in any estimate of m. Taken together, these data indicate that, under the present experimental conditions, LTE is expressed as an increase in quantal size, rather than an increase in the number of quanta released per presynaptic impulse. Although this is not definitive evidence for a postsynaptic mechanism, these findings do further restrict the classes of possible presynaptic mechanisms that may be proposed to account for LTE expression.

Action Potentials↗

Sensitivity analysis for high quantiles of ochratoxin A exposure distribution.

Using available data from a consumption survey and contamination data on ochratoxin A (OA) in food, a sensitivity analysis (SA) for high quantiles (95th and 99th quantiles) of OA exposure distribution was carried out, obtained by a Monte Carlo simulation in French children. Exposure assessment for food contaminants is important to control the risk of foodborne diseases. Risk assessors are interested in high quantiles of contaminant exposure distributions. As these exposure distributions are generally very asymmetrical, it is difficult to obtain relevant and stable high quantiles in such a context. Determining OA exposure distribution is complex because it is based on the sum of elementary exposure distributions (eight foodstuffs are analysed here), and each one of these is the product of a consumption distribution and a contamination distribution. The SA enables us to quantify the influences of the parameter variability of the consumption and contamination probability density functions (pdf) which have been fitted to the data, our simulation model inputs, on the 95th and 99th quantiles of the output exposure distribution. After some preliminary trials, we have postulated a quadratic polynomial regression model for the quantiles of OA exposure distribution in view of undertaking this SA. This regression model comprises 32 main factors, their 496 two-factor interactions and their 32 quadratic terms. The 32 factors are the parameters of the fitted pdf: 16 parameters of Gamma distributions relative to the eight consumed foods and 16 parameters of Gamma distributions relative to the eight food OA contaminations. For an optimal parameter estimation of such a large model, we used an experimental design approach depending on a resolution-V fractional factorial design of 6561 experiments. The factor ranges are established by a preliminary study of bootstrap sampling. From the bootstrap samples, the factor ranges are obtained taking into account the correlation between the two parameters of the fitted Gamma pdf. A full exposure distribution is simulated for each of the 6561 experiments. The consumption dependencies are taken into account by the Iman and Conover method. On the basis of this analysis, validated and useful models for each desired quantile are obtained showing a major influence of the parameters of "Cereals" (consumption and contamination) and slightly less so for parameter of "Pork" consumption in the sensitivity of the quantiles.

Adolescent↗

The velocity-response curves of the cat's superior colliculus neurons.

The velocity-response curves of the cat's superior colliculus neurons responding to moving stimuli mere studied quantitatively. They were fitted by logarithmic Gaussian curves described by three parameters: optimal stimulus velocity, amplitude and dispersion of the curve. Since reversal of the stimulus movement direction changed neither optimal stimulus velocity nor dispersion of the velocity tuning curve, then the fourth parameter, directional asymmetry, is postulated to describe fully, in conjunction with three parameters mentioned above, the dependence of the neuron response to velocity and direction on the stimulus motion. All parameters were roughly normally distributed and uncorrelated with each other in the sample of cells investigated. Some implications of our results for the classification of cells, and some arguments for population coding” against single cell trigger feature coding are discussed.

Animals↗

Quinoprotein glucose dehydrogenase modified thick-film electrodes for the amperometric detection of phenolic compounds in flow injection analysis.

The use of thick-film electrodes as basic transducers for highly sensitive amperometric biosensors using PQQ (pyrroloquinoline quinone) dependent glucose dehydrogenase (GDH) with short response times is described. The enzyme is embedded in a polyurethane matrix on top of a platinum based thick film electrode and its ability to reduce oxidized phenolic compounds is exploited. The electrochemical amplification is based on the oxidation of the analyte on the surface of the electrode followed by its enzymatic reduction. Different parameters of the glucose dehydrogenase electrode system using dopamine as a model analyte were optimized, e.g., membrane thickness, pH value, buffer system, flow rate and storage conditions. Using optimized parameters the sensitivity and detection limits for various phenolic compounds were evaluated. The comparison of electrodes from the identical as well as from different batches shows the ability to produce a number of well reproducible sensors showing remarkably small differences with respect to parameters as sensitivity, response times and measuring range.

Acinetobacter calcoaceticus↗

The mechanism of reaction of ferricyanide-pretreated mixed-valence-state membrane-bound cytochrome oxidase with oxygen at 173 K.

1. The results of non-linear optimization studies on the mechanism of reaction of ferricyanide-pretreated mixed-valence-state cytochrome oxidase with O2 at 173 K are presented. The analysis is carried out on data obtained by means of dual-wavelength multi-channel spectroscopy at four wavelength pairs (444-463 nm, 604-630 nm, 608-630 nm and 830-940 nm) and at two O2 concentrations (360 micron and 520 micron). The only model that satisfies the triple requirement of a standard deviation within the standard error of the experimental data, a random distribution of residuals and good determination of the optimized parameters, is a three-intermediate sequential mechanism. 2. On the basis of the optimized values of the relative absorption coefficients of the intermediates at each wavelength obtained from the present paper together with data from optical wavelength scanning and e.p.r. spectroscopy obtained by low-temperature trapping studies, the possible valence states of the metal centres in each of the intermediates are discussed.

Chemical Phenomena↗

Developmental increase in CA3-CA1 presynaptic function in the hippocampal slice.

1. We recorded extracellular and intracellular CA3-CA1 synaptic responses in hippocampal slices from neonatal rats [postnatal day (P) 15-21 and P29-35]. Presynaptic function was examined by measuring input-output relationships and paired-pulse facilitation and by quantal analysis of minimally evoked responses. 2. Extracellular recording revealed no difference in excitatory postsynaptic potential (EPSP) threshold or the fiber potential response for a given stimulus intensity between the two age groups. However, the slope of the field EPSP was consistently larger in older animals. The increase in EPSP slope was associated with a decrease in paired-pulse facilitation, suggesting an increase in presynaptic function with postnatal development. 3. Extracellular results were confirmed by intracellular recordings that revealed no difference in the minimal stimulation intensity needed to evoke a response, an increase in mean EPSP amplitude with development, and a decrease in paired-pulse facilitation. Quantal parameters were extracted by three separate methods including method of failures, coefficient of variance, and parameter optimization through noise deconvolution. All methods supported presynaptic mediation of facilitation. Comparison of quantal parameters during development indicated an increase in mean quantal content. 4. The results demonstrate that synaptic strength is altered over the course of development because of, at least in part, changes in presynaptic release mechanisms. Developmental differences in presynaptic function provide an explanation of differences in mechanisms for expression of long-term potentiation. The lower initial probability of transmitter release in neonates may permit increased presynaptic change.

Animals↗

Feasibility of using intracardiac impedance measurements for capture detection.

Energy consumption and longevity of modern pacemakers are determined by the controlling electronic circuitry and by the stimulation energy. While with technological progress the electronics' energy consumption has been reduced significantly, clinical practice shows that many cardiac pacemakers are programmed to suboptimal settings with regard to minimization of pacing energy consumption. Several methods for optimizing pacemaker output settings have been proposed in the past. The most promising concept is an output parameter optimizing pacemaker with automatic capture detection. We examined whether it is possible to distinguish between effective and ineffective pacemaker stimulus capture by analyzing high pass filtered intracardiac impedance signals that are derived from standard bipolar pacing leads. In one series of 11 patients undergoing replacement or implantation of chronic bipolar pacemakers, four patients during electrophysiology studies, and eight volunteers undergoing invasive electrophysiology trials, we examined intracardiac impedance signals obtained with various stimulation rates and output parameter settings. Additionally we analyzed a series of five patients with implanted pacemakers that can measure and telemeter intracardiac impedance signals. Several evaluation concepts have been analyzed regarding their ability to discriminate between effective and ineffective stimuli. We developed an adequate algorithm that detects capture or loss of capture at different output parameter settings based on intracardiac impedance analysis. The sensitivity is 98.5% and specificity is 91% to loss of capture for the currently investigated algorithm and this can be used to determine the optimal setting of pulse width and amplitude with regard to energy consumption. This concept is currently under realization in the external programmer and in the future an implementation of these algorithms within the pacemaker itself is intended.

Algorithms↗

Wall compliance and violin cavity modes.

Violin corpus wall compliance, which has a substantial effect on cavity mode frequencies, was added to Shaw's two-degree-of-freedom (2DOF) network model for A0 ("main air") and A1 (lowest length mode included in "main wood") cavity modes. The 2DOF model predicts a V(-0.25) volume dependence for A0 for rigid violin-shaped cavities, to which a semiempirical compliance correction term, V(-x(c)) (optimization parameter x(c)) consistent with cavity acoustical compliance and violin-based scaling was added. Optimizing x(c) over A0 and A1 frequencies measured for a Hutchins-Schelleng violin octet yielded x(c) approximately 0.08. This markedly improved A0 and A1 frequency predictions to within approximately +/- 10% of experiment over a range of about 4.5:1 in length, 10:1 in f-hole area, 3:1 in top plate thickness, and 128:1 in volume. Compliance is a plausible explanation for A1 falling close to the "main wood" resonance, not increasingly higher for the larger instruments, which were scaled successively shorter compared to the violin for ergonomic and practical reasons. Similarly incorporating compliance for A2 and A4 (lowest lower-/upper-bout modes, respectively) improves frequency predictions within +/-20% over the octet.

Journal Article↗

[Electrostimulation of the phrenic nerve in dogs].

Respiratory parameters have been studied by electrical stimulation of phrenic nerves (EPN) in 12 dogs. The optimal parameters of an electrical stimulus were found for long-term EPN. EPN increased minute respiratory volume, when respiratory rate raised to 18 per min, and decreased, when respiratory rate diminished to 6 per min. Another parameter--oxygen utilization index--diminished at high respiratory rate and increased at low one, which reflected hyper- or hypoventilation status, respectively. The data obtained indicate that controlled lung ventilation may maintain living status of dogs for a long time without alteration of general respiratory parameters.

Animals↗