PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “reflection”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15Linked to original sources

Reflection of retrograde waves within the cochlea and at the stapes.

A number of authors [de Boer and Viergever, Hear. Res. 13, 101-112 (1984); de Boer et al., in Peripheral Auditory Mechanisms (Springer-Verlag, Berlin, 1986); Hear. Res. 23, 1-7 (1986); Viergever, in Auditory Frequency Selectivity (Plenum, New York, 1986), pp. 31-38; Kaernbach et al., J. Acoust. Soc. Am. 81, 408-411 (1987)] have argued that backward-traveling waves, in striking contrast to waves traveling forward towards the helicotrema, suffer appreciable reflection as they move through the basal turns of the cochlea. Such reflection, if present, would have important consequences for understanding the nature and strength of otoacoustic emissions. The apparent asymmetry in reflection of cochlear waves is shown, however, to be an artifact of the boundary condition those authors impose at the stapes: conventional cochlear models are found not to generate reflections of waves traveling in either direction even when the wavelength changes rapidly and the WKB approximation breaks down. Although backward-traveling waves are not reflected by the secular variation of the geometrical and mechanical characteristics of the cochlea, they are reflected when they reach the stapes. The magnitude of that boundary reflection is computed for the cat and shown to be a large, rapidly varying function of frequency.

Acoustics↗

Color of cultures of Staphylococcus epidermidis determined by spectral reflectance colorimetry.

Brown, Richard W. (National Animal Disease Laboratory, Ames, Iowa). Color of cultures of Staphylococcus epidermidis determined by spectral reflectance colorimetry. J. Bacteriol. 91:911-918. 1966.-A colorimeter with a reflectance attachment was used to study pigment production by Staphylococcus epidermidis strains grown on a medium containing Trypticase Soy Agar (BBL) and cream. The color of each culture was first characterized by reflectance colorimetry for dominant wavelength, purity, and luminous reflectance (Y) and was then classified visually into 1 of 10 color grades. There was not complete agreement in grading colors by the two methods, inasmuch as cultures that were considered more pigmented in relation to other cultures by the reflectance method were sometimes graded visually as less pigmented, and vice versa. Nevertheless, when the cultures were visually graded as being more pigmented, there was a concomitant increase in the average values of dominant wavelength and purity with a decrease in Y for the cultures in each higher grade. Thus, the nonpigmented cultures had the lowest dominant wavelength and purity values but the highest Y (brightness) values, whereas the most pigmented cultures had the highest dominant wavelength and purity values, but the lowest Y values. These results indicated that the cultures did not produce pigments of different hues (greenish-yellow, yellow, yellowish-orange) each with high, medium, and low degrees of purity and brightness. The value (1 - z), where the chromaticity coordinate z = Z/(X + Y + Z), was found to be proportional to the purity value. An inverse relationship between the tristimulus Z and purity values was also demonstrated. All cultures tested by the reflectance method were also classified according to the type of spectral absorption curve obtained with pigments extracted from the cultures with methanol. A comparison of these methods indicated that determining the type of spectral absorption curve would be better for differentiating strains of S. epidermidis, whereas the use of the reflectance method would be better for determining differences of pigment production within strains.

Color↗

A method for estimating macromolecular reflection by human synovium, using measurements of intra-articular half lives.

Recent studies show that very large macromolecules in synovial fluid, such as hyaluronan and large proteoglycans, are partially reflected by the synovial lining during fluid drainage, and thus selectively retained within the cavity. Size selective molecular reflection is a fundamental property of membranes, and a method for quantifying the reflective behaviour of human synovium could be of value in several pathophysiological areas. The method proposed here is based on the intra-articular half lives of the macromolecule of interest and of a smaller, easily cleared protein such as albumin. The key relation is derived from the law of conservation of mass, using simple algebra. It is found that, when the intra-articular half lives of albumin and a macromolecular test solute are determined simultaneously, the reflected fraction of the test solute is given by the complement of the half life ratio. Examples are given. Intra-articular half lives can thus be used to consider such questions as whether immune complexes are significantly reflected by the synovial surface, how the reflective property changes in arthritides or with treatment, and how significantly reflection might influence the intra-articular concentration of large "markers" of joint disease activity.

Half-Life↗

Differential effects of wave reflections and peripheral resistance on aortic blood pressure: a model-based study.

It has been generally accepted that arterial system wave reflections act to increase aortic blood pressure and the load placed on the left ventricle. Using a mathematical model of the coupled left ventricle-arterial system, we predict that this is not the case. With the model, two aspects of wave reflection, the global reflection coefficient [TG(omega)] and the pulse wave velocity (cph), were adjusted independently. In addition, TG(omega) and cph could be altered independently of the direct-current properties of the arterial system model. Reduction of TG(omega) yielded increases in stroke volume (SV) as well as in peak systolic (Ps), diastolic (Pd), and mean aortic (Pao) pressures and, hence, increased the load on the left ventricle. SV and Pao increased only in the range where strong reflection occurs. Reduced cph also yielded higher pressures, whereas increased cph resulted in reduced Pao and Pd but increased Ps. The changes in pressures and SV in response to altered TG(omega) and cph were relatively small compared with absolute levels. Simulated vasoconstriction and vasodilation further demonstrated the much greater importance of peripheral resistance on pressure and SV levels and lead to the prediction that pressure reduction in vasodilation occurs not because of, but in spite of, reduced wave reflections. We conclude that these results have not yet been observed experimentally, because reflection cannot yet be separated from the direct-current properties of the arterial system; therefore wave reflections themselves have not yet been adequately studied in the intact animal.

Animals↗

Negative wave reflections in pulmonary arteries.

The pulmonary arterial branching pattern suggests that the early systolic forward-going compression wave (FCW) might be reflected as a backward-going expansion wave (BEW). Accordingly, in 11 open-chest anesthetized dogs we measured proximal pulmonary arterial pressure and flow (velocity) and evaluated wave reflection using wave-intensity analysis under low-volume, high-volume, high-volume + 20 cmH2O positive end-expiratory pressure (PEEP), and hypoxic conditions. We defined the reflection coefficient R as the ratio of the energy of the reflected wave (BEW [-]; backward-going compression wave, BCW [+]) to that of the incident wave (FCW [+]). We found that R = -0.07 +/- 0.02 under low-volume conditions, which increased in absolute magnitude to -0.20 +/- 0.04 (P < 0.01) under high-volume conditions. The addition of PEEP increased R further to -0.26 +/- 0.02 (P < 0.01). All of these BEWs were reflected from a site ~3 cm downstream. During hypoxia, the BEW was maintained and a BCW appeared (R = +0.09 +/- 0.03) from a closed-end site ~9 cm downstream. The normal pulmonary arterial circulation in the open-chest dog is characterized by negative wave reflection tending to facilitate right ventricular ejection; this reflection increases with increasing blood volume and PEEP.

Animals↗

Pressure-altering agents affect central aortic pressures more than is apparent from upper limb measurements in hypertensive patients: the role of arterial wave reflections.

The pressure pulse does not have the same amplitude in central and peripheral arteries, but it is amplified toward the periphery; the degree of this amplification depends principally on wave reflection. Despite the conventional clinical and epidemiological focus on peripheral pressures, the most physiologically relevant pressures for both cardiac and vascular effects are central pressures. The reflected wave contributes differently in the configuration of the peripheral and central pressure waveform. Therefore, we hypothesized that agents that alter wave reflections could have an unequal effect on central and peripheral pressures in hypertensive patients. Thus, the effect of caffeine was investigated in 10 hypertensive subjects according to a randomized, placebo-controlled, double-blind, crossover design. Central aortic pressures and wave reflection were assessed with applanation tonometry and pulse wave analysis. After caffeine, augmentation index and augmented pressure increased by 4.6%, (P<0.005) and 5.7 mm Hg (P<0.001), respectively, indicating increased effect of wave reflection from the periphery. The increase in aortic systolic pressure was greater compared with that in radial artery pressure at 30 minutes (25%) and marginally greater at 60 minutes (21%). Furthermore, the increase in aortic pulse pressure was greater at 30 and 60 minutes (34% and 40%, respectively). The intensified reflected wave after caffeine was largely responsible for the disparate effect between central and peripheral pressures by boosting the peak of the central and not of the peripheral waveform. This study shows that pressure-altering agents might affect central pressures more than is apparent from the corresponding upper limb values because of the concomitant changes in wave reflection.

Aorta↗

Specular reflections and the perception of shape.

Many materials, including leaves, water, plastic, and chrome exhibit specular reflections. It seems reasonable that the visual system can somehow exploit specular reflections to recover three-dimensional (3D) shape. Previous studies (e.g., J. T. Todd & E. Mingolla, 1983; J. F. Norman, J. T. Todd, & G. A. Orban, 2004) have shown that specular reflections aid shape estimation, but the relevant image information has not yet been isolated. Here we explain how specular reflections can provide reliable and accurate constraints on 3D shape. We argue that the visual system can treat specularities somewhat like textures, by using the systematic patterns of distortion across the image of a specular surface to recover 3D shape. However, there is a crucial difference between textures and specularities: In the case of textures, the image compressions depend on the first derivative of the surface depth (i.e., surface orientation), whereas in the case of specularities, the image compressions depend on the second derivative (i.e., surfaces curvatures). We suggest that this difference provides a cue that can help the visual system distinguish between textures and specularities, even when present simultaneously. More importantly, we show that the dependency of specular distortions on the second derivative of the surface leads to distinctive fields of image orientation as the reflected world is warped across the surface. We find that these "orientation fields" are (i) diagnostic of 3D shape, (ii) remain surprisingly stable when the world reflected in the surface is changed, and (iii) can be extracted from the image by populations of simple oriented filters. Thus the use of specular reflections for 3D shape perception is both easier and more reliable than previous computational work would suggest.

Cues↗

[Effects of information on and reflection of women's pain experience during mammography].

At mammography, strong compression of the breasts is required to reduce the radiation dose and to obtain radiographic images of high quality. In recent times the mass media have received a number of letters with complaints about the painfulness of the examination and an unsympathetic reception by the personnel. The aim of this study was to find out what effect information and a special manner of reception ("reflection") had on the experience of pain at mammography. Reflection meant that the X-ray nurse, in an accepting manner, reflected the feelings and facts which the woman expressed. The study was performed as a 2 x 2 factorial design. One independent variable was a letter of information, with the two alternatives letter of information and no letter of information, and another was reflection, with the two alternatives reflection and no reflection. Seventy-six women were randomly allocated to these four conditions. The letter of information stated why the examination was to be performed, how it is done and how it is usually experienced. The results showed that all women in all groups experienced relatively little pain. They considered that they were well received and were satisfied with the information. The difference between the groups was small. There was a tendency for those who were both received with reflection and were given a letter of information to be more satisfied with the examination as compared with the other women. A larger number of women in this former group than in the other groups stated reasons for their assessment. This result was significant.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Using reflection to develop clinical expertise.

Reflection is becoming widely recognized as an effective means by which nurses can develop their practice and is a prominent feature of both pre- and postregistration education programmes. More specifically, the UKCC directs that all nurses are required to keep a personal, professional profile, which means that they are obliged to engage in reflective activities. In order to develop practice, nurses must reflect on what they do and what they would want to do better. Reflection is a purposeful activity which is more than just a recall of events. Implicit within reflective activity is a need on the relector's part to change behaviour. The following article explores the concepts of expertise and reflection and suggests how one may relate to the other. Its purpose is to heighten awareness of the use of reflection for profile development and ultimately as a means of developing nursing practice.

Clinical Competence↗

Reflection demystified: answering some common questions.

There is a growing body of literature related to reflection. However, few authors address how to reflect at a practical level. This article aims to answer some of the more common questions about reflection: What is reflection about? What is its value for nursing practice? What skills are needed to be a reflective practitioner? Where to start? There are doubts concerning the effectiveness of reflection and there is little research evidence regarding its benefits. Despite this, it is argued that reflection has the potential to raise nurses' awareness of practice.

Clinical Competence↗

Sub-quarter-wave multilayer coatings with high reflectance in the extreme ultraviolet.

Multilayer coatings with a small number of layers were designed and prepared to provide an increase in normal-incidence reflectance in the extreme ultraviolet compared with the reflectance of available single-layer coatings, namely, SiC, B4C, and Ir. Multilayers were designed to produce coatings with the highest possible reflectance at 91.2 and at 58.4 nm. At these wavelengths all the materials absorb radiation strongly, but still a reflectance enhancement can be obtained by means of sub-quarter-wave multilayer coatings with two or more different materials. Sub-quarter-wave multilayer coatings based on Al, MgF2, diamondlike carbon, B4C, SiC, and Ir showed higher reflectance than single-layer coatings of SiC and B4C not only at the target wavelength but in a wide band ranging from 50 nm to the 121.6-nm H Lyman-alpha line. Multilayer coatings suffered some reflectance degradation over time. However, after approximately 80-100 days of aging in a desiccator, the reflectance for the multilayer coatings was greater than for the single-layer coatings.

Journal Article↗

Experimental analysis in recording transmission and reflection holograms at the same time and location.

Holographic recording media with a reflection layer are useful because they make it possible to maintain backward compatibility with CDs and DVDs, and a conventional servo system is easily attachable. The incident beam is fed back to the recording layer by the reflection layer, so there are four beam pairs to record the transmission and reflection holograms. We analyze the basic property of the transmission and reflection holograms and evaluate the problem when the transmission and reflection holograms are recorded at the same time. It is shown that the shrinkage in the photopolymer medium has a different effect on each hologram, so the readout image from the two holograms is misaligned. Those diffraction beams make the interference pattern, and the signal-to-noise ratio (SNR) of the output image decreased. Taking into account the difference in wavelength selectivity between the transmission and the reflection holograms, we propose a way to select one hologram to get the diffraction beam and eliminate the interference pattern using the tuning readout wavelength. By using this method, we can eliminate the diffraction beam from the reflection hologram and keep a high SNR.

Journal Article↗

Characterization of normal and abnormal pulmonary surface by reflected ultrasound.

The use of reflected ultrasound in the diagnosis of pulmonary disease has been limited due to the strong reflection and high absorption of acoustic energy by alveoli containing air. Our study reports the ultrasonic characteristics of normal and diseased pulmonary surface. Two measurements, the coefficient of pulmonary reflection and the tissue frequency signature, were studied with specially calibrated instuments. The coefficient of pulmonary reflection in 23 normal subjects was - 19.6 +/- 0.1 dB at 5.5 MHz. In ten patients with documented pulmonary emboli, the coefficient of pulmonary reflection was -47.4 +/- 0.1 dB, significantly less than normal (P less than 0.1). The tissue frequency signature in 18 normal subjects was specular at higher and nonspecular at lower frequencies, with a typical dip at 5.2 MHz. In patients with chronic obstructive pulmonary disease, the tissue frequency signature was flat, and the typical dip was absent. In patients with pulmonary emboli, the characteristic shape of the tissue frequency signature was preserved, but there was a generalized loss of magnitude of the reflection. Thus, our preliminary data indicate that reflected ultrasound provides a noninvasive method for differentiating normal from diseased pulmonary surfaces.

Animals↗

Assessing carotenoid content in plant leaves with reflectance spectroscopy.

Spectral reflectance of maple, chestnut and beech leaves in a wide range of pigment content and composition was investigated to devise a nondestructive technique for total carotenoid (Car) content estimation in higher plant leaves. Reciprocal reflectance in the range 510 to 550 nm was found to be closely related to the total pigment content in leaves. The sensitivity of reciprocal reflectance to Car content was maximal in a spectral range around 510 nm; however, chlorophylls (Chl) also affect reflectance in this spectral range. To remove the Chl effect on the reciprocal reflectance at 510 nm, a reciprocal reflectance at either 550 or 700 nm was used, which was linearly proportional to the Chl content. Indices for nondestructive estimation of Car content in leaves were devised and validated. Reflectances in three spectral bands, 510+/-5 nm, either 550+/-15 nm or 700+/-7.5 nm and the near infrared range above 750 nm are sufficient to estimate total Car content in plant leaves nondestructively with a root mean square error of less than 1.75 nmol/cm2.

Algorithms↗

Impact of reflective mulch on yield of strawberry plants and incidence of damage by tarnished plant bug (Heteroptera: Miridae).

The current study investigated the impact of reflective mulch on yield of strawberry plants and incidence of damage by tarnished plant bugs, Lygus lineolaris (Palisot de Beauvois), for three strawberry cultivars: 'Honeoye', 'Earliglow', and two sibling Dayneutrals ('Tribute' and 'Tristar', herein considered as one cultivar). Of all cultivars tested, Honeoye was the most productive and least susceptible to tarnished plant bug. For Earliglow and Honeoye, reflective mulch enhanced productivity of strawberry plants and suppressed density of nymphs per flower cluster and proportion of damaged fruits, but did not significantly impact numbers of nymphs or damaged fruits per hectare, Results with Dayneutrals were not consistently significant. Both in the presence or absence of reflective mulch, proportion of damaged fruits increased with increasing density of nymphs per flower cluster and with decreasing number of fruits harvested per row section, suggesting that planting productive strawberry cultivars or maintaining cultural practices that promote high yield may provide an effective line of defense against tarnished plant bug. These results also suggest that reflective mulch may suppress incidence of damage by tarnished plant bug both directly, by reducing number of nymphs per flower cluster, and indirectly, by enhancing productivity of strawberry plants. Economic analyses evaluating costs and benefits of using reflective mulch, as well as studies investigating mechanisms that underlie the impact of reflective mulch on yield and incidence of damage by tarnished plant bug, are still needed before reflective mulch can be implemented as a management strategy in commercial strawberry fields.

Agriculture↗

Reflection in the disability education of undergraduate nurses: an effective learning tool?

Reflection was integrated into an undergraduate nursing curriculum, with different frameworks demonstrating the application of a structured approach to reflection. Reflection is defined as examination and exploration of an issue of concern to help create or clarify meaning. The aim of this qualitative study was to evaluate the usefulness of formal reflection in the context of undergraduate nursing education during the disability module. Twelve reflection assignments written by second-year nursing students were analyzed. The analysis indicated that students' reflection focused less on their experience of working with people with disabilities and more on their overall learning experience and coping with clinical practice. A central theme, Coping with Clinical Practice, and four subthemes were identified. Students acknowledged reflection as beneficial to their learning and linked to their clinical practice.

Adult↗

Journaling: a quasi-experimental study of student nurses' reflective learning ability.

The use of journaling or journal writing in clinical education is one of the strategies used to develop critical thinking. Reflective journal writing, as it is commonly known, can nurture many qualities of a critical thinker and promote thoughtful nursing practice. Using a quasi-experimental design in this study, reflective journaling was introduced to a sample of first year Bridging Course student nurses at a Private Nursing Education Institution, to assess its effectiveness in reflective learning. The study design enabled comparisons between two groups: one group of students assigned to do journaling (experimental group) and another group of students (control group) who did not journal. The students in the experimental group were given a period of eight weeks to journal their clinical experiences. At the end of this period, both groups were given an exercise, based on a clinical situation, to analyse reflectively and a comparison made on their performance. Descriptive statistics were used to analyse data and Fisher's Exact Test was used to determine the significance of differences observed within and between groups. The results showed that students in the experimental group performed better in exploring alternatives of action (p < 0.10) and formulating responses in similar future situations (p < 0.05) during the process of reflection. There was no significant difference between the groups' scores with regard to their ability to describe the clinical experience, to explore their related feelings, to evaluate the experience and to interpret/create meaning for themselves. Recommendations are made for continued student support and guidance during clinical education if reflection is considered to enhance reflective, thoughtful nursing practice.

Documentation↗

Reflection: a challenging innovation for nurses.

The concepts of reflection and reflective practice have been widely embraced by the nursing profession despite some apparent ambivalence highlighted in the literature. On the one hand, reflection is reported to be a valuable and powerful educational process; it is claimed to develop practice-based theories, encourage practitioners to evaluate their practice, promote learner self-awareness, narrow the theory-practice gap, challenge habitual practice and identify tacit knowledge. On the other hand, commentators point out that there is insufficient empirical evidence to support these claims and that its unstructured implementation can have deleterious effects on practitioners' psychological well-being and the outcomes of nursing education. It will be argued in this paper that the realisation of the benefits claimed to accrue from reflective practice together with the avoidance of its potential deleterious personal and educational outcomes hinges on three factors. These are: firstly, that the frameworks or protocols introduced to promote reflective practice are consistent with the purposes it seeks to achieve; secondly, that the essentially political nature of reflective practice is recognised and addressed; and thirdly, that the resourcing requirements for introducing and maintaining reflective practice in clinical units are also recognised and addressed.

Adult↗