PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “space driven”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15Linked to original sources

Estimating a state-space model from point process observations.

A widely used signal processing paradigm is the state-space model. The state-space model is defined by two equations: an observation equation that describes how the hidden state or latent process is observed and a state equation that defines the evolution of the process through time. Inspired by neurophysiology experiments in which neural spiking activity is induced by an implicit (latent) stimulus, we develop an algorithm to estimate a state-space model observed through point process measurements. We represent the latent process modulating the neural spiking activity as a gaussian autoregressive model driven by an external stimulus. Given the latent process, neural spiking activity is characterized as a general point process defined by its conditional intensity function. We develop an approximate expectation-maximization (EM) algorithm to estimate the unobservable state-space process, its parameters, and the parameters of the point process. The EM algorithm combines a point process recursive nonlinear filter algorithm, the fixed interval smoothing algorithm, and the state-space covariance algorithm to compute the complete data log likelihood efficiently. We use a Kolmogorov-Smirnov test based on the time-rescaling theorem to evaluate agreement between the model and point process data. We illustrate the model with two simulated data examples: an ensemble of Poisson neurons driven by a common stimulus and a single neuron whose conditional intensity function is approximated as a local Bernoulli process.

Action Potentials↗

Computer-controlled mechanical lung model for application in pulmonary function studies.

A computer controlled mechanical lung model has been developed for testing lung function equipment, validation of computer programs and simulation of impaired pulmonary mechanics. The construction, function and some applications are described. The physical model is constructed from two bellows and a pipe system representing the alveolar lung compartments of both lungs and airways, respectively. The bellows are surrounded by water simulating pleural and interstitial space. Volume changes of the bellows are accomplished via the fluid by a piston. The piston is driven by a servo-controlled electrical motor whose input is generated by a microcomputer. A wide range of breathing patterns can be simulated. The pipe system representing the trachea connects both bellows to the ambient air and is provided with exchangeable parts with known resistance. A compressible element (CE) can be inserted into the pipe system. The fluid-filled space around the CE is connected with the water compartment around the bellows; The CE is made from a stretched Penrose drain. The outlet of the pipe system can be interrupted at the command of an external microcomputer system. An automatic sequence of measurements can be programmed and is executed without the interaction of a technician.

Humans↗

Verification of nerve root decompression during minimally-invasive lumbar microdiskectomy: a practical application of surgeon-driven evoked EMG.

Lumbar microendoscopic diskectomy (MED) has gained widespread acceptance as an alternative to conventional open microdiskectomy due to several potential advantages, including reductions in postoperative pain and recovery time. However, constraints in visualization and working space present technical difficulties in the verification of nerve root decompression and the identification of sequestered disc fragments. This study was undertaken to investigate whether a surgeon-driven, evoked EMG paradigm could be used for intraoperative verification of nerve root decompression within the technical and mechanical confines of lumbar MED. Twenty-two patients underwent intraoperative EMG stimulation threshold recordings during lumbar microendoscopic diskectomy. In this series, the EMG threshold recorded directly from the nerve root immediately prior to diskectomy was 8.6 +/- 4.4 mA. Following decompression, the threshold was 4.2 +/- 2.1 mA. The difference in pre- and post-decompression EMG stimulation threshold, 4.4 +/- 4.0 mA, was statistically significant (p < 0.001). In two of the 22 cases (9.1 %), the EMG threshold was initially unchanged following diskectomy, and further exploration revealed sequestered disc fragments. After removal of these fragments, an appropriate decrease in the EMG threshold was observed. The results from this study suggest that surgeon-driven, evoked EMG threshold testing may provide a simple, effective adjunct to lumbar microendoscopic diskectomy for intraoperative verification of nerve root decompression.

Adult↗

Spatio-temporal analysis of the role of climate in inter-annual variation of malaria incidence in Zimbabwe.

BACKGROUND: On the fringes of endemic zones climate is a major determinant of inter-annual variation in malaria incidence. Quantitative description of the space-time effect of this association has practical implications for the development of operational malaria early warning system (MEWS) and malaria control. We used Bayesian negative binomial models for spatio-temporal analysis of the relationship between annual malaria incidence and selected climatic covariates at a district level in Zimbabwe from 1988-1999. RESULTS: Considerable inter-annual variations were observed in the timing and intensity of malaria incidence. Annual mean values of average temperature, rainfall and vapour pressure were strong positive predictors of increased annual incidence whereas maximum and minimum temperature had the opposite effects. Our modelling approach adjusted for unmeasured space-time varying risk factors and showed that while year to year variation in malaria incidence is driven mainly by climate, the resultant spatial risk pattern may to large extent be influenced by other risk factors except during high and low risk years following the occurrence of extremely wet and dry conditions, respectively. CONCLUSION: Our model revealed a spatially varying risk pattern that is not attributable only to climate. We postulate that only years characterized by extreme climatic conditions may be important for developing climate based MEWS and for delineating areas prone to climate driven epidemics. However, the predictive value of climatic risk factors identified in this study still needs to be evaluated.

Bayes Theorem↗

A novel configuration of bioartificial liver support system based on circulating microcarrier culture.

The purpose of this investigation is to initiate a new bioartificial liver support system that utilizes circulating microcarrier cultures in the extracapillary space of a hollow fiber cartridge. The material exchange occurs on the membranes of the hollow fiber. Toxins are metabolized by the circulating cells on the microcarriers driven by a centrifugal pump. We inoculated 2-3 x 10E8 Hep G2 cells on 2.5 grams of Cytodex 3 microcarriers, and allowed them flowing in the extracapillary space of a modified plasma filter. 10% FCS Medium was pumped through the capillaries at different rates. Cells keep morphological integrity and functionality during the circulation. These preliminary results suggest that this configuration of a bioartificial liver support system offers a future investigation.

Albumins↗

Does the nuclear envelope contain two types of ligand-gated Ca2+ release channels?

The nuclear envelope is composed of two membranes deliminating a perinuclear space which displays functional properties similar to those of a Ca2+-storing compartment. ATP-driven Ca2+ uptake and InsP3-induced Ca2+ release processes have been described in isolated nuclei. Recently, it was reported that cADP-ribose and InsP3 can trigger a nucleoplasmic Ca2+ increase. It was hypothesized that the inner nuclear membrane possesses Ca2+ channels that are regulated by ryanodine or InsP3. Radio-ligand binding assays and Western blot experiments were performed in order to investigate their presence in sheep cardiac and rat liver nuclear envelopes. Ryanodine receptors (RyR) were not detected in liver nuclear envelopes by either binding assay or Western blot analysis. However, cardiac nuclear envelopes were found to retain a very low level of specific ryanodine binding, which was not detected on immuno-blots obtained with three types of isoform-specific RyR antibodies. In contrast, nuclear InsP3-binding sites were consistently detected in both cardiac and liver nuclear envelopes. Altogether, these results provide evidence for the major contributor InsP3-gated Ca2+ channels in control of Ca2+ release from the perinuclear space in liver and cardiac cells.

Animals↗

A fast-freezing device with a retractable environmental chamber, suitable for kinetic cryo-electron microscopy studies.

The design and construction of a fast-freezing device are described. A polycarbonate chamber, in which the humidity and temperature are controlled by microprocessors, slides on a robust chassis guided by ball or Teflon bushings. In its freezing position, the chamber rests on top of the cryogen vessel. The specimen is therefore frozen directly from the experimental conditions within the chamber without exposure to the external environment. After freezing, the chamber, but not the specimen, rises automatically, vacating space for handling the specimen. The chamber, the shutter, and the specimen are all driven pneumatically at an adjustable speed of up to approximately 10 m s-1 and coordinated by either pneumatic or electronic logical gates. Provisions are made for automatic blotting, spraying, and flashing. The chamber is compatible with a liquid nitrogen-cooled copper block assembly for impact (slam) freezing for freeze-substitution and freeze-fracture.

Cryopreservation↗

Syringomyelia and the arachnoid web.

Three cases of syringomyelia associated with arachnoid webs are reported. Each patient presented with progressive myelopathy and had thoracic syringes detected on magnetic resonance imaging (MRI). In one patient the web was also visible. At operation a thoracic arachnoid web was found, obstructing the subarachnoid compartment in each patient. One patient had intraoperative ultrasound, which demonstrated caudal web movement with each cardiac systole. The webs were divided and shunts inserted into the syringes. All patients improved clinically, and on follow-up MRI. Arachnoid webs are likely to represent a focal band of arachnoiditis and are difficult to visualise on standard preoperative MR imaging. A reduction in the subarachnoid space compliance with resultant increase in pulse pressure and potentiation of an arterial pulsation driven perivascular flow could explain the associated syringes. Treatment should be aimed at restoring compliance, and involve division of the web with or without shunt insertion.

Adult↗

Reduction of mass bias and matrix effects in inductively coupled plasma mass spectrometry with a supplemental electron source in a negative extraction lens

Electrons from a heated tungsten filament are created inside the extraction lens and driven out toward the skimmer. These electrons move through the ion path and reduce space charge effects between positive ions in the beam. The ion transmission efficiency is improved by factors of two (for Pb+) to 27 (for Li+). The greater sensitivity improvement for low-mass ions leads to a substantial reduction in mass bias. With the additional electrons, MO+/M+ and M2+/M+ abundance ratios increase but can be minimized with a small reduction in aerosol gas flow rate. No new background ions are observed with this technique. Matrix effects can be significantly diminished when the electron source is operated under the high electron current mode. The mass dependence of matrix-induced suppression of analyte signals is essentially eliminated. Using flow injection analysis to minimize solid deposition, the technique can tolerate Na matrix up to 10000 ppm (1%) with only approximately 15% loss of analyte sensitivity.

Journal Article↗

Diffusion by extrinsic noise in the kicked Harper map.

A significantly improved analytic understanding of the extrinsically driven diffusion process is presented in a nonlinear dynamical system in which the phase space is divided into periodic two-dimensional tiles of regular motion, separated by a connected separatrix network (web) [previously studied by A. J. Lichtenberg and Blake P. Wood, Phys. Rev. Lett. 62, 2213 (1989)]. The system is represented by the usual "kicked Harper map" with added extrinsic noise terms. Three different diffusion regimes are found depending upon the strength of the extrinsic perturbation l relative to the web and regular motions. When the extrinsic noise is dominant over the intrinsic stochasticity and the regular rotation motions in the tile, diffusion obeys the random phase scaling l(2). When the extrinsic noise is dominant over the intrinsic stochasticity, but weaker than the regular rotation motion, the diffusion scales as lK(1/2), where K is the strength of the intrinsic kick. These findings agree well with numerical simulation results. When the extrinsic noise process is weaker than the stochastic web process, we analytically reproduce the well-known numerical result: The web diffusion is reduced by the ratio of phase-space areas of intrinsic to extrinsic stochasticity.

Journal Article↗

Entrainment of a spatially extended nonlinear structure under selective forcing.

The response of a nonlinear state to a variable forcing periodic in space is studied in an extended dynamical system consisting of a liquid crystal layer driven to convection. Both the statics and the dynamics of the entrainment and the locking effects are analyzed. The dynamics of the evolution are controlled by topological singularities that allow a diffusion of the phase. The mechanisms involved are related to the role of the defects in systems undergoing spontaneous symmetry breakings.

Journal Article↗

Are ions involved in the gating of calcium channels?

The rates of activation and deactivation of the currents carried by calcium, strontium, or barium ions through the voltage-sensitive calcium channel of Paramecium are different. The differences cannot be attributed to complications due to internal ion concentration, calcium channel inactivation, potassium current activation, surface charge effects, or incomplete space clamping. The findings indicate participation of the divalent cations in the voltage-driven calcium channel gating process.

Animals↗

Biphasic blood volume changes with lower body suction in humans.

We recorded blood and plasma mass density and hematocrit of antecubital venous blood in 12 subjects in the supine position before, during, and after 20-40 min of lower body subatmospheric pressure (LBNP) of -35 mmHg. Mass density values decreased during the first minutes of LBNP, indicating a transient 2.8% blood volume gain before they rose as expected. After LBNP, a pronounced further density increase, indicating a further 1.5% hemoconcentration, preceded the return toward control. This pattern suggests reflex-driven transient filtration effects. Computed mass density of fluid exchanged between blood and extravascular space was 1,007.2 +/- 4.4 milligrams (37.0 degrees C); mass density of erythrocytes remained unaltered. We conclude that sudden unloading of central pressure receptors with LBNP causes microvascular fluid gain preceding fluid loss (hemoconcentration) during LBNP, and receptor loading after LBNP additionally causes fluid loss preceding inward filtration (hemodilution) during recovery. These effects can be quantified with high-precision blood and plasma mass densitometry performed by the mechanical oscillator technique.

Adolescent↗

An orbiting scroll blood pump without valves or rotating seals.

Valves in blood pumps are expensive and provide modes of failure. Rotating seals offer sites of thrombus formation and infection. In this study, a prototype pump incorporating no valves or rotating seals was constructed and tested. In this device, fluid is pumped by the orbital action of a spiral shaped scroll relative to an identical stationary scroll whose starting axis is rotated 180 degrees with respect to the orbiting scroll. The two scrolls, which are machined integral with scroll plates, form pockets that are filled from the outside and then ejected in the center as the orbiting scroll completes each cycle. The orbiting scroll is driven by a crank mechanism connected to a motor. Fluid is contained in the space around the scrolls by a flexible collar and does not contact the driving mechanism. The prototype pump is approximately 7.6 cm in diameter and 2.5 cm thick and has an orbiting radius of 5.1 mm. The output of the pump was very sensitive to the clearance between the scroll tip and the base of the opposite scroll plate. For a clearance of 51 microns, pressure differences as high as 400 mmHg and flows as high as 7.7 l/min (of water) were produced at 260 rpm. At 450 rpm with a 330 microns clearance, pressure differences as high as 185 mmHg and flows as high as 7.3 l/min resulted. The relationships between pressure difference and flow were very linear in all cases. Volumetric efficiency was as high as 70% and increased with speed.

Biomechanical Phenomena↗

Aquaporin-4 water channel protein in the rat retina and optic nerve: polarized expression in Müller cells and fibrous astrocytes.

The water permeability of cell membranes differs by orders of magnitude, and most of this variability reflects the differential expression of aquaporin water channels. We have recently found that the CNS contains a member of the aquaporin family, aquaporin-4 (AQP4). As a prerequisite for understanding the cellular handling of water during neuronal activity, we have investigated the cellular and subcellular expression of AQP4 in the retina and optic nerve where activity-dependent ion fluxes have been studied in detail. In situ hybridization with digoxigenin-labeled riboprobes and immunogold labeling by a sensitive postembedding procedure demonstrated that AQP4 and AQP4 mRNA were restricted to glial cells, including MHller cells in the retina and fibrous astrocytes in the optic nerve. A quantitative immunogold analysis of the MHller cells showed that these cells exhibited three distinct membrane compartments with regard to AQP4 expression. End feet membranes (facing the vitreous body or blood vessels) were 10-15 times more intensely labeled than non-end feet membranes, whereas microvilli were devoid of AQP4. These data suggest that MHller cells play a prominent role in the water handling in the retina and that they direct osmotically driven water flux to the vitreous body and vessels rather than to the subretinal space. Fibrous astrocytes in the optic nerve similarly displayed a differential compartmentation of AQP4. The highest expression of AQP4 occurred in end feet membranes, whereas the membrane domain facing the nodal axolemma was associated with a lower level of immunoreactivity than the rest of the membrane. This arrangement may allow transcellular water redistribution to occur without inducing inappropriate volume changes in the perinodal extracellular space.

Animals↗

The effect of seating force and die spacing on pulpward cementation pressure transmission: a laboratory study.

Pulpward pressure transmission during crown cementation occurs via the dentinal tubules. The present study investigated the effect of crown seating forces and the effect of increasing the die spacing on pulpward pressure transmission. Twenty upper premolars were prepared with 1 mm shoulder margins for non-precious metal full crowns. A 0-104 kPa pressure transducer (Mediamate EA, Data Instruments, Baltimore, MD, USA) was connected, via the sectioned root of the premolar, to the pulp chamber which was perfused with saline at 83 kPa driven by nitrogen gas, for two hours prior to cementation. Crowns with 2 or 6 layers of die-spacing were seated with 25 N or 100 N force using zinc-phosphate cement. The pressure transducer was connected to a Wheatstone bridge (Measurements Group, Instruments Division) and the extent of crown seating and output from the pressure transducer was recorded. Results indicate that 25 N seating force produced a lower mean pulpward pressure (41 +/- 54 Pa) compared to the 100 N seating force (251 +/- 276 Pa). Seating was significantly improved with 6 layers of die-spacing (seating discrepancy 18 +/- 12 mm) compared with 2 layers (139 +/- 111 mm). It is concluded that a higher seating force increases pulpward pressure transmission. Increasing die spacing improved crown seating but did not affect the amount of pressure transmitted.

Adolescent↗

Water transport and the distribution of aquaporin-1 in pulmonary air spaces.

Recent evidence suggests that water transport between the pulmonary vasculature and air spaces can be inhibited by HgCl2, an agent that inhibits water channels (aquaporin-1 and -5) of cell membranes. In the present study of isolated rat lungs, clearances of labeled (3HOH) and unlabeled water were compared after instillation of hypotonic or hypertonic solutions into the air spaces or injection of a hypotonic bolus into the pulmonary artery. The clearance of 3HOH between the air spaces and perfusate after intratracheal instillation and from the vasculature to the tissues after pulmonary arterial injections was invariably greater than that of unlabeled water, indicating that osmotically driven transport of water is limited by permeability of the tissue barriers rather than the rate of perfusion. Exposure to 0.5 mM HgCl2 in the perfusate and air-space solution reduced the product of the filtration coefficient and surface area (PfS) of water from the air spaces to the perfusate by 28% after instillation of water into the trachea. In contrast, perfusion of 0.5 mM HgCl2 in air-filled lungs reduced PfS of the endothelium by 86% after injections into the pulmonary artery, suggesting that much of the action of this inhibitor is on the endothelial surfaces. Confocal laser scanning microscopy demonstrated that aquaporin-1 is on mouse pulmonary endothelium. No aquaporin-1 was found on alveolar type I cells with immunogold transmission electron microscopy, but small amounts were present on some type II cells.

Animals↗

Sensory experience and the formation of a computational map of auditory space in the brain.

The basic wiring of the brain is first established before birth by using a variety of molecular guidance cues. These connections are then refined by patterns of neural activity, which are initially generated spontaneously and subsequently driven by sensory experience. In the superior colliculus, a midbrain nucleus involved in the control of orienting behaviour, visual, auditory, and tactile inputs converge to form superimposed maps of sensory space. Maps of visual space and of the body surface arise from spatially ordered projections from the retina and skin, respectively. In contrast, the map of auditory space is computed within the brain by tuning the neurons to different localization cues that result from the acoustical properties of the head and ears. Establishing and maintaining the registration of the maps in the face of individual differences in the size and relative positions of different sense organs is an activity-dependent process in which the synaptic circuits underlying the auditory representation are modified and calibrated under the influence of both auditory and visual experience. BioEssays 1999;21:900-911.

Animals↗