PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “AORTIC STENOSIS”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16Linked to original sources

Doppler echocardiography as a predictor of pregnancy outcome in the presence of aortic stenosis: A case report.

Aortic stenosis in pregnancy can be a life-threatening condition, but fortunately it is rare. In the modern era, careful obstetric and cardiologic monitoring, particularly through echocardiography, have improved fetal and maternal outcomes. However, a test that could predict outcome has not been available for patients with aortic stenosis who seek prepregnancy counseling. We report a case in which exercise Doppler echocardiography was used to predict cardiac function and maximal gradients in a woman with a bicuspid aortic valve who wished to become pregnant.

Adult↗

Accelerated progression of calcific aortic stenosis in dialysis patients.

BACKGROUND: Abnormalities of the aortic valve occur with increased frequency in patients with renal failure and may contribute to the observed excess cardiovascular mortality. Little data exist on the rate at which aortic stenosis progresses in this patient group. METHODS: A retrospective case-control study was designed to compare the rate of progression of aortic stenosis in dialysis patients with that in sex-matched controls. Dialysis patients with aortic stenosis were identified by a search of the echocardiography database. Twenty-eight dialysis patients were compared to 56 sex-matched controls, all of whom had aortic stenosis on at least two echocardiograms 6 months apart. Changes in mean and peak transvalvular gradient as well as valve area were calculated from echocardiographic data and compared. RESULTS: Aortic stenosis progressed more rapidly in the dialysis patients than in the controls when measured by change in valve area (-0.19 vs. -0.07 cm2/year; p < 0.001) and change in peak transvalvular gradient (6.5 vs. 3.9 mm Hg/ year; p = 0.04). There was also a trend towards more rapid progression of mean transvalvular gradient (4.9 vs. 2.5 mm Hg/year; p = 0.052). On multivariate linear regression analysis, only end-stage renal failure (p = 0.02) and baseline valve area (p = 0.04) predicted accelerated progression of aortic stenosis. CONCLUSIONS: Aortic stenosis progressed more rapidly in the presence of renal failure. The time frames for review and operation in dialysis patients should be shorter than for the general population.

Aged↗

Coronary-subclavian steal associated with severe aortic stenosis treated with combined percutaneous stenting and minimally invasive aortic valve replacement.

We describe coronary-subclavian steal restricting flow to the left internal mammary artery (LIMA) associated with critical aortic stenosis treated with combined percutaneous transluminal stenting and minimally invasive aortic valve replacement (AVR). An 86-year-old patient had coronary artery bypass graft placement (CABG) seven years prior with the LIMA anastomosed to the left anterior descending coronary artery (LAD). At the time of CABG, the patient had mild aortic stenosis and normal left ventricular function. By the time of re-presentation with refractory angina and heart failure, the patient had developed critical aortic stenosis. Because repeat CABG with median sternotomy risked damaging the LIMA, pre-operative revascularization was planned to minimize the likelihood of peri-operative ischemia. Stenting of the subclavian artery was performed prior to minimally invasive AVR.

Aged↗

Retrograde percutaneous aortic valve implantation for critical aortic stenosis.

Recently, a prosthetic aortic valve has been implanted percutaneously in several patients using an antegrade transseptal approach. This has been shown to be feasible and associated with dramatic hemodynamic improvement. We report a retrograde implantation of a percutaneous heart valve (PHV) in an 84-year-old man with critical aortic stenosis and refractory congestive heart failure after difficulties encountered with an initial antegrade approach. While attempting antegrade transseptal implantation of a PHV, the anterior leaflet of the mitral valve was tethered by the guidewire resulting in severe mitral regurgitation and pulseless electrical activity. Cardiac resuscitation was successful. Utilizing a retrograde approach, the PHV was successfully implanted in a stable position below the coronary ostia and well above the mitral valve leaflets. The aortic valve area increased from 0.55 to 1.7 cm2 with only mild paravalvular aortic regurgitation. Despite marked improvement in aortic valve function, the patient died secondary to guidewire-induced mitral valve anterior leaflet laceration, severe mitral regurgitation, and cardiogenic shock. Retrograde implantation of a PHV can be successfully performed with substantial increase in aortic valve area and an acceptable degree of aortic regurgitation. Although the retrograde approach may be associated with greater risk of vascular access site complications, it may be considerably safer by avoiding potential guidewire injury to the mitral valve. Further refinements in technique may establish the retrograde approach as the preferred means of PHV implantation in nonsurgical patients with critical aortic stenosis.

Aged↗

Predictors of mortality, complications, and length of stay in aortic valve replacement for aortic stenosis.

The introduction of aortic balloon valvuloplasty has prompted review of established techniques to treat aortic valve disease. To this end, the surgical results were reviewed for 1,148 patients undergoing aortic valve replacement, with and without associated coronary artery bypass grafting, for aortic stenosis between January 1, 1975 and September 1, 1987. The overall death rate was 4.6%. The neurological event rate (stroke or reversible ischemic event) was 4.2%, the myocardial infarction rate was 3.5%, and 30.7% had a hospital stay in excess of 10 days. Mortality for isolated elective aortic valve replacement rose from 2.5% for patients under age 70 to 7.3% for those over age 70. Mortality for elective aortic valve replacement plus coronary bypass was 3.8% for patients under age 70 and 11.6% for patients over age 70. The neurological event rate rose from 3.0% to 8.4% and the prolonged length of stay from 28% to 42%. By stepwise logistic regression analysis, the predictors of in-hospital mortality were age and emergent surgery. Age was the only multivariate predictor of neurological events. The year of surgery and emergent status were the multivariate predictors of prolonged length of hospital stay. Aortic valve replacement for aortic stenosis is a well-established technique with low neurological event rates and mortality, which may be predicted in advance. Newer techniques must be considered in light of data such as these.

Aged↗

The prognostic value of intraoperative pressure gradients with congenital aortic stenosis.

Patients with congenital aortic stenosis are subject to sudden death without prior symptoms. Indications for operation are based on pressure gradients, but intraoperative evaluation of results after relief of obstruction can be subjective and arbitrary. Between September, 1981, and October, 1983, 21 patients underwent operation for relief of congenital aortic stenosis. Fifteen had valvular, 4 had supravalvular, and 2 had subvalvular stenosis. Seven patients were 1 year of age or younger, 2 being 3 days old. Preoperative inotropic support and emergency operation were necessary in 2 patients. Intraoperative pressure gradients were measured in all but the 2 patients who were 3 days old. All patients survived without complications. Intraoperative and postoperative pressure gradients were available in 16 patients. The average preoperative pressure gradient was 76 mm Hg. It was significantly lowered to 20 mm Hg (p less than 0.001) intraoperatively, which compared with 15 mm Hg postoperatively. Three patients had an unsatisfactorily high intraoperative pressure gradient after initial intervention. Immediate reexploration and incision of the rudimentary commissure in 2 and excision of redundant valvular tissue in the other resulted in a more satisfactory pressure gradient without substantial aortic insufficiency. We suggest that measurement of intraoperative pressure gradients can accurately assess the results of therapy and allow the surgeon the option of reexploration for further intervention. Moreover, the high correlation between intraoperative and postoperative pressure gradients can help in planning postoperative management and future cardiac catheterizations.

Adolescent↗

[Pathophysiologic role of myocardial hypertrophy, microcirculatory dysfunction and cardiomyocyte apoptosis in aortic stenosis].

The burden of aortic stenosis is increasing steadily and, despite major advances in diagnosis and management, surgical valve replacement is still the only effective treatment. Most recently, experimental studies in animals and clinical studies in humans have shown that myocardial hypertrophy, microcirculatory dysfunction and cardiomyocyte apoptosis are among the central pathophysiologic mechanisms involved in the natural history of aortic stenosis, i.e. the passage from a compensated and hypertrophic heart to a dysfunctional heart prone to ischemia, arrhythmia and pump failure. This updated review emphasizes the promises of these new research avenues as well as their potential therapeutic applications.

Aortic Valve Stenosis↗

Gastrointestinal bleeding in aortic stenosis.

Gastrointestinal bleeding in aortic stenosis is an uncommon condition but when present it is often undiagnosed. The usual radiological proceedures fail to demonstrate the source of bleeding. Mesenteric angiography, however, will identify the lesion. The lesion is usually a vascular malformation located in the right colon. The angiodysplasia may also occur in other parts of the gastrointestinal tract. We have encountered five patients with aortic stenosis who had multiple massive hemorrhages of the lower gastrointestinal tract who defied diagnosis by the conventional methods. Mesenteric angiography, however, disclosed the orgin of the bleeding. In four patients vascular malformations were found in the right colon and one in the jejunum. Right hemicolectomy and partial jejunectomy resulted in a cure in all.

Aged↗

[Aortic stenosis in the elderly].

Aortic stenosis is observed with an increasing frequency in the elderly. Main features in the elderly are the frequency of advanced stage of the heart disease, and of associated diseases, either cardiac, in particular coronary lesions, or extracardiac. This can explain that perioperative morbidity and mortality are higher than in younger patients. However, after the operative period, long-term prognosis is good. Life expectancy becomes similar to a general population and functional results are excellent. In case of symptomatic aortic stenosis in the elderly, the decision to operate should take into account an evaluation of the individual risk to benefit ratio, and avoid to differ the decision until an advanced stage of the disease.

Age Factors↗

Determination of coronary reserve in patients with supravalvular aortic stenosis.

Coronary reserve in patients with supravalvular aortic stenosis may be limited by coronary artery ostial obstruction or left ventricular hypertrophy. To assess the relative effect of these two factors on coronary reserve, seven patients with supravalvular aortic stenosis were studied intraoperatively before and after repair. Six patients who underwent elective cardiac surgery for conditions that did not involve the left ventricle or the left anterior ascending coronary artery served as controls (control group 1). Four patients were studied before and after cardiopulmonary bypass to determine if cardiopulmonary bypass altered coronary reserve in normal vessels perfusing normal ventricle (control group 2). Using a pulsed Doppler probe to determine coronary velocity, coronary reactive hyperemia was induced in the left anterior descending coronary artery (patients with supravalvular aortic stenosis and group 1 controls) or right ventricular branches of the right coronary artery (group 2 controls) during maximal coronary dilation produced by a 20-second coronary occlusion. All patients with supravalvular aortic stenosis underwent patch aortoplasty to relieve left coronary artery ostial obstruction and outflow tract obstruction; three patients also underwent aortic valvotomy and one patient also underwent valve replacement. Coronary reactive hyperemia was calculated as the ratio of peak to resting velocity. This ratio was 5.0 +/- 0.6 (mean +/- SEM) preoperatively and 3.6 +/- 0.3 postoperatively in control group 2. Thus, coronary reserve was only modestly reduced after cardiopulmonary bypass. Before repair, the ratio of peak to resting velocity was markedly reduced in patients with supravalvular aortic stenosis compared with control group 1 (1.8 +/- 0.3 vs 4.9 +/- 0.5, p less than 0.05) and did not change after repair (1.7 +/- 0.2), even though the aortic gradient was reduced (80 +/- 14 vs 38 +/- 6 mm Hg, p less than 0.05) and real or potential coronary ostial obstruction was eliminated by the operation. Because coronary reserve did not improve after surgery in patients with supravalvular aortic stenosis, we conclude that left ventricular hypertrophy is probably the primary determinant of decreased coronary reserve in these patients.

Adolescent↗

Clinical evaluation of high-frequency (ultrasonic) mechanical débridement in the surgical treatment of calcific aortic stenosis.

Repair of aortic valve stenosis due to calcific degeneration may lead to hemodynamic and clinical improvement without the problems inherent with prosthetic valves. We have evaluated the use of a device capable of débriding calcium, the Cavitron ultrasonic aspirator (CUSA), as an adjunct to mechanical débridement in the repair of calcific aortic stenosis. Ten patients (five women), ages 63 to 83 years, were studied by M-mode, two-dimensional, and Doppler echocardiography before and an average of 26 (range 3 to 124) days after this procedure. The degree of calcification of the valve cusps was clearly reduced. The maximal cusp excursion increased from 0.7 +/- 0.1 cm preoperatively to 1.5 +/- 0.4 cm postoperatively (p = 0.006). The peak aortic gradient fell from 80 +/- 36 mm Hg to 28 +/- 10 mm Hg (p = 0.0007). The mean aortic gradient fell from 53 +/- 20 mm Hg to 16 +/- 5 mm Hg (p less than 0.0001). Aortic valve area calculated by the continuity equation increased from 0.6 + 0.2 cm2 to 1.6 +/- 0.6 cm2 (p = 0.0009). No patient had more than mild aortic insufficiency preoperatively. Postoperatively, color Doppler flow mapping revealed severe aortic insufficiency in two patients. Seven patients had further echocardiographic evaluation 99 (range 33 to 196) days after the procedure. These studies revealed the development of severe aortic insufficiency in an additional four patients. Four patients with severe symptomatic aortic insufficiency eventually underwent aortic valve replacement. Pathology revealed scarring and retraction of the aortic cusps. Widening of the commissures was responsible for the severe aortic insufficiency.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

Normal rate of ventricular emptying in valvular aortic stenosis.

The delayed upstroke of the arterial pulse in valvular aortic stenosis has been attributed, in part, to prolonged left ventricular emptying. Left ventricular emptying rate, however, has not been measured in aortic stenosis. We assessed the rate of left ventricular emptying by computer analysis of biplane cineangiograms in seven normal subjects, six patients with mild to moderate aortic stenosis, and 12 patients with severe aortic stenosis. As an indicator of delayed arterial pulse rise, T time index (time to half maximum aortic pressure corrected for heart rate) was measured in each group. T time index averaged 0.07 +/- 0.01 units in normal subjects, 0.14 +/- 0.04 units in the patients with mild to moderate aortic stenosis, and 0.13 +/- 0.05 units in those with severe aortic stenosis. Patients with mild to moderate and severe aortic stenosis differed significantly from normal subjects. Relative emptying rates were defined as the percentage of initial systolic volume ejected divided by the percentage of systole elapsed. These relative emptying rates were determined during the first, second, and third thirds of systole in all three groups. No significant decrease in the relative rate of left ventricular emptying was noted when each group of patients with aortic stenosis was compared with the normal subjects. Neither was there slowing in the actual rate of ejection of blood in ml per second throughout systole. We conclude that the rate of ventricular emptying is normal in aortic stenosis and does not explain the arterial pulse delay in this disease.

Adult↗

Changes in effective aortic valve area during ejection in adults with aortic stenosis.

Measurements of valve orifice area in aortic stenosis are based on the assumption that orifice area remains constant throughout ejection and is independent of transvalvular gradients and flow. Recent studies, however, have suggested that the calculated valve area of calcific aortic stenosis may change in different flow conditions. Therefore, we tested the hypothesis that in vivo effective orifice area of a stenotic aortic valve changes continuously during ejection, which would make a single area measurement a potentially inadequate indicator of the severity of the stenosis. Doppler measurements of flow velocity in the ascending aorta and in the left ventricular outflow tract at peak velocity, at half-peak velocity during acceleration (midacceleration), and at half-peak velocity during deceleration (mid-deceleration) were obtained in 26 patients with aortic stenosis (mean gradient 50 +/- 19 mm Hg and effective aortic orifice are 0.7 +/- 0.3 dcm2) and in 14 normal subjects of similar age and gender, to calculate instantaneous effective aortic orifice area at midacceleration, at peak velocity and at mid-deceleration. In the 26 patients with aortic stenosis, aortic valve area at midacceleration was 84 +/- 15% of valve area at peak velocity (p < 0.0001), and valve area at mid-deceleration was 113 +/- 17% of that measured at peak velocity (p < 0.01). Conversely, in normal subjects, aortic valve area remained constant during ejection and was 97 +/- 5% and 99 +/- 6% of valve area at peak velocity, respectively, at midacceleration and mid-deceleration (p > 0.05). In addition, in patients with aortic stenosis the percentage of change in effective aortic valve area from midacceleration to mid-deceleration varied widely, from -17% to +49% (mean change +26 +/- 14%). There was no relation between percentage of change in effective valve area and mean transaortic gradient (r = 0.05; p = 0.30) or effective valve area at peak velocity (r = -0.11; p = 0.14). Our results indicate that effective aortic valve area continues to change during ejection in patients with aortic stenosis, and that the magnitude of this change is independent of the usual indexes of severity of the stenosis. Conversely, effective aortic valve area remains constant during ejection in normal subjects.

Aged↗

Cinefluoroscopy of the aortic valve: an accurate noninvasive method for assessing critical aortic stenosis in the elderly.

The purpose of this study was to assess whether the degree of fluoroscopic aortic valve calcification could help identify the presence of aortic stenosis in the elderly. To evaluate the diagnostic utility of cardiac fluoroscopy for the detection of aortic stenosis (aortic valve area less than or equal to 1.0 cm 2) in patients 60 years or older, aortic valve area determined by cardiac catheterization was related to the pattern of calcification seen on cinefluoroscopy in 97 patients (mean age of 72 +/- 6 years) with suspected aortic stenosis. Dense circumferential (3+) calcification of the aortic valve was seen on cinefluoroscopy in 56 of 59 patients with an aortic valve area less than or equal to 1.0 cm 2 (sensitivity 95%), compared to 5 of 38 patients with aortic valve area greater than 1.0 cm2 (specificity 87%) (p less than .001). These findings suggest that in patients 60 years of age or older with suspected aortic stenosis, a dense circumferential (3+) aortic valve calcification on cinefluoroscopy is highly predictive of an aortic valve area less than or equal to 1.0 cm2 with a positive predictive accuracy of 91% and a negative predictive accuracy of 91%. Thus cinefluoroscopy may provide an accurate adjunct or alternative to Doppler echocardiography in the assessment of aortic stenosis in the elderly.

Aged↗

Aortic valve replacement in elderly patients with aortic stenosis.

OBJECTIVE: To assess the risk of aortic valve replacement and long-term follow-up in elderly patients with dominant aortic stenosis. DESIGN: Retrospective analysis of patients who had aortic valve replacement over a 10 year period and were routinely seen in an outpatient clinic. SETTING: University hospital. PATIENTS: 93 patients aged > or = 60 and 47 patients > or = 70 years with symptomatic aortic stenosis undergoing aortic valve replacement. MAIN OUTCOME MEASURES: Early and late mortality in different age groups. Influence of preoperative signs and symptoms on overall outcome. RESULTS: The proportion of patients older than 70 years increased from 11% in 1978 to 54% in 1986. Perioperative mortality was 3.6% and mortality after 2 and 5 years was 9% and 13% respectively. Survival was similar (85% and 83%, respectively) in patients aged 60-69 years (group 1, n = 93, mean age 64.5 (2.7) and patients aged > or = 70 years (group 2, n = 47, mean age 72.6 (2.5)). Additional coronary artery disease and coronary bypass grafting did not significantly affect survival. The cardiothoracic ratio was inversely related to survival (Cox regression, p < 0.05). Preoperative symptoms (syncope, angina pectoris, and dyspnoea) were similar in both patient groups. After a mean (SD) follow up of 51 (33) months 96% of surviving patients were in NYHA functional class I or II with no difference between the two age groups. Similarly, the cardiothoracic ratio and Sokolow index decreased to near normal values in both age groups. CONCLUSION: The risk of aortic valve replacement in patients with dominant aortic stenosis is low and not significantly influenced by age. Therefore replacement may be performed without increased risk in elderly patients and with a good long-term outcome.

Age Factors↗

Prophylactic aortic valve replacement in older patients for mild aortic stenosis during coronary bypass surgery.

Coronary bypass surgery (CBS) is performed in many older patients who frequently also have mild calcific aortic stenosis. It is important that a correct assessment of the severity of aortic stenosis is done by calculating the aortic valve area. Mild aortic stenosis is aortic valve area >1.5 cm(2), >0.9 cm(2)/m(2); severe aortic stenosis is aortic valve area < or =1.0 cm(2), < or =0.6 cm(2)/m(2). Patients who have severe aortic stenosis should have aortic valve replacement (AVR) at the time of CBS. Patients with mild aortic stenosis should not have AVR simultaneously with CBS because: 1) patients having AVR+CBS have a higher operative and 10-year mortality; 2) prosthetic heart valves are associated with a complication rate of 2%-6% per year; and 3) only about 12% of patients with mild aortic stenosis will have developed severe aortic stenosis in 10 years. Performing AVR for mild aortic stenosis at the time of CBS will probably result in 91 unnecessary AVRs and 29 excess deaths in 10 years.

Aged↗

Reversibility of cardiac dysfunction after valve replacement in elderly patients with severe aortic stenosis.

BACKGROUND: The role of aortic valve replacement for aortic stenosis has not been fully defined in terms of the postoperative reversibility of cardiac dysfunction and pulmonary hypertension in elderly patients. METHODS: Cardiac function, assessed by radioisotope ventriculography and catheterization data, was evaluated before and after operation, and their results were compared between preoperative and postoperative data in each group of younger patients (<69 years, group I, n = 29) and elderly patients (> or =70 years, group II, n = 21). RESULTS: One month postoperatively the peak ejection rate determined by radioisotope ventriculography improved significantly in comparison with the preoperative value in elderly patients (preoperatively, 228 +/- 38 versus postoperatively, 319 +/- 116% end-diastolic volume per second, p < 0.05), although their preoperative peak ejection rate was severely depressed. The postoperative peak filling rate of the elderly group was not completely reversible to almost normal value, whereas that of the younger group was completely reversible. Early diastolic peak filling rate (one-third peak filling rate) was not reversible in both two groups. Pulmonary hypertension in the elderly patients was reversible to postoperative almost normal pulmonary artery pressure despite the severity of aortic stenosis (systolic pulmonary artery pressure preoperatively, 37 +/- 16 mm Hg versus postoperatively, 25 +/- 5 mm Hg, p < 0.02; diastolic pulmonary artery pressure preoperatively, 15 +/- 6 mm Hg versus postoperatively, 10 +/- 4 mm Hg, p < 0.05). CONCLUSIONS: Both cardiac dysfunction, reflected by reduction of peak ejection rate, and pulmonary hypertension in elderly patients with severe aortic stenosis were reversed, reaching almost normal values 1 month after operation.

Aged↗

Unnecessary deaths from valvular aortic stenosis.

The annual mortality from aortic valvular stenosis was calculated among potential candidates for surgical replacement of the aortic valve. From the Swedish Central Register of Causes of Death, 70 patients below the age of 80 years who had died from aortic stenosis during a 1-year period in the County of Stockholm (population 1.5 million), were identified. A retrospective analysis of their medical records showed that 37 individuals were suitable candidates for surgery. The presence of aortic stenosis had been verified at autopsy in 31 (84%) patients. The remaining six patients (16%) had their aortic stenosis diagnosis established by a thorough non-invasive investigation performed before death. Although typical signs and symptoms of aortic stenosis were recorded in all 37 patients, only six (16%) of them had been considered by their physicians to be suitable candidates for surgery prior to death. The deceased patients were compared with a group of 68 patients who had undergone aortic valve replacement for aortic stenosis during the same period. There were no significant differences between the two groups with regard to symptoms and clinical findings, except for a higher incidence of syncope in the operated group. It is concluded that, of 105 (68 surgically treated and 37 deceased) eligible patients with aortic stenosis, 37 individuals did not receive surgical care in time. The reason for this was probably insufficient knowledge of the curability of the disease.

Aged↗