PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Computer Peripherals”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16Linked to original sources

Operationalizing a bedside pen entry notebook clinical database system in consultation-liaison psychiatry.

No current system of computerized data entry of clinical information in consultation-liaison (C-L) psychiatry has been well received or has demonstrated that it saves the consultant's time. The inability to achieve accurate, complete, systematic collection of discrete variables and data entry in the harried C-L setting is a major impediment to the advancement of the subspecialty and health services research. The hand-held Notebook computer with Windows PEN ENTRY MICROCARES capabilities has permitted one-time direct entry of data at the time of collection at the patient's bedside. Variable choice and selection enhances the completeness and accuracy of data collection. For example, ICD-9, Axis III diagnoses may be selected from a "look-up" which at the same time automatically assigns the appropriate code and diagnostic-related groups, (DRG) number. A patient narrative can be typed at the nurse's station, a chart note printed for the medical record, and the MICRO-CARES literature database perused with the printing of selected citations, abstracts, and in some cases experts' commentaries for the consultee. The consultant's documentation time is halved using the NOTEBOOK WINDOWS PEN ENTRY MICRO-CARES software, with the advantage of more accurate and complete data description than with the traditional handwritten consultation records. Consultees preferred typewritten in contrast to handwritten notes. The cost of the hardware (about $2000) is less than that of an optical scanner, and it permits report generation and archival searches at the nurses' station without returning to the C-L office for scanning. Radio frequency or ethernet download from the Notebook permits direct data transfer to th C-L office archive computer.

Attitude of Health Personnel↗

[Navigated implantation of total knee endoprostheses--a comparative study with conventional instrumentation].

OBJECTIVE: A navigation system should improve the quality of a total knee prosthesis implantation in comparison to the classical, surgeon-controlled operative technique. METHODS: The authors have implanted 40 knee total prostheses with an optical infrared navigation system (Orthopilot AESCULAP, Tuttlingen--group A). The quality of implantation was studied on postoperative long leg AP and lateral X-rays, and compared to a control group of 40 computer-paired total knee prostheses o the same model (Search Prosthesis, AESCULAP, Tuttlingen) implanted with a classical, surgeon-controlled technique (group B). RESULTS: An optimal mechanical femorotibial angle (3 degrees valgus to 3 degrees varus) was obtained by 33 cases in group A and 31 cases in group B (p > 0.05). Better results were seen for the coronal and sagittal orientation of both tibial and femoral components in group A. Globally, 26 cases of the group A and 12 cases of the group B were implanted in an optimal manner for all studied criteria (p < 0.01). CONCLUSIONS: The used navigation system allows a significant improvement of the quality of implantation of a knee total prosthesis in comparison to a classical, surgeon-controlled instrumentation. Long-term outcome could be consequently improved.

Arthroplasty, Replacement, Knee↗

["Spatial shift alignment (SSA)"--a new method for determining blood flow velocity in video capillary microscopy].

A new technique (spatial shift alignment [SSA]) for measuring capillary blood velocity in human capillaries in the skin is described. A capillaroscopic image is digitized by means of a frame grabber. Within the lumen of a suitable capillary limb a region of interest known as a slot is placed. At a frame frequency of 25 per second, this slot is copied in a free part of the frame grabber store along a horizontal axis. A static space-time image with light diagonal bands representing the plasma gaps in their passage through the capillary limb is obtained. By determining the gradient of the diagonal bands, a measure of the capillary blood velocity is obtained. The SSA system was validated by means of a simulated model using known fixed velocities between 0 and 1.0 mm/sec (r = 0.979, n = 24). The procedure can be employed with any image processing systems, and enables continuous monitoring of the velocity measurements. Since it is time-saving and just as accurate as the frame-to-frame method, SSA could be widely applied to the measurement of blood cell velocity in capillaroscopy.

Blood Flow Velocity↗

Electrophoretic gel image analysis software for the molecular biology laboratory.

We present GelReader 1.0, a microcomputer program designed to make precision, digital analysis of one-dimensional electrophoretic gels accessible to the molecular biology laboratory of modest means. Images of electrophoretic gels are digitized via a desktop flatbed scanner from instant photographs, autoradiograms or chromogenically stained blotting media. GelReader is then invoked to locate lanes and bands and generate a report of molecular weights of unknowns, based on specified sets of standards. Frequently used standards can be stored in the program. Lanes and bands can be added or removed, based upon users' subjective preferences. A unique lane histogram feature facilitates precise manual addition of bands missed by the software. Image enhancement features include palette manipulation, histogram equalization, shadowing and magnification. The user interface strikes a balance between program autonomy and user intervention, in recognition of the variability in electrophoretic gel quality and users' analytical needs.

Computer Peripherals↗

Bone density reduction in various measurement sites in men and women with osteoporotic fractures of spine and hip: the European quantitation of osteoporosis study.

We have measured bone mineral density (BMD) using dual X-ray absorptiometry (DXA) of the spine and hip, spinal quantitative computed tomography (QCTspi), and peripheral radial quantitative computed tomography (pQCTrad) in 334 spine and 51 hip fracture patients. The standardized hip and spine BMD for each patient was calculated and compared with the combined reference ranges published previously, each densitometer having been cross-calibrated with the prototype European Spine Phantom (ESPp) or the European Forearm Phantom (EFP). Male and female fracture cases had similar BMD values after adjusting for body size, where appropriate. This suggests that the relationship between bone density (mass per unit volume) and fracture risk is similar between men and women. However, compared with age-matched controls, mean decreases in BMD ranged from 0.78 SD units (women with hip fracture, DXAspi) to 2.57 SD units (men with spine fractures, QCTspi). The proportion of spine and hip fracture patients falling below the cutoff for osteoporosis (T-score <-2.5 SD) proposed by the World Health Organization (WHO) study group varied according to different BMD measurement procedures (range 18-94%). This finding suggests that the WHO definition requires different thresholds when used with non-DXA BMD measurement techniques. Receiver operator characteristic (ROC) analysis was used to compare measurement techniques for their ability to discriminate between cases and controls. Among DXA sites, the proximal femur was preferred when evaluating generalized bone loss, particularly in elderly people. An additional spinal BMD measurement may add clinical value if spine fracture risk assessment has a high priority. Both axial and peripheral QCT techniques performed comparably to DXA in spinal osteoporosis, so investigators and clinicians may use any of the three technologies with similar degrees of confidence for the diagnosis of generalized or site-specific bone loss providing straightforward clinical guidelines are followed.

Absorptiometry, Photon↗

Corrected formula for estimating peripheral blood flow by impedance plethysmography.

In this paper, the limitations of the conventional formula for the computation of peripheral blood flow from impedance plethysmograms are highlighted, and a correction to the formula is suggested. A conductivity cell experiment is described to show the dependence of the value of the blood flow index (BFI), obtained from the conventional formula, on the mean resistivity of the cell. It is also shown that the value of the corrected BFI is independent of the mean resistivity. Anomalies observed in the amplitude of systolic waves in impedance plethysmograms of patients with oedema are explained.

Adult↗

Biopotentials as command and feedback signals in functional electrical stimulation systems.

Today Functional Electrical Stimulation (FES) is available as a clinical tool in muscle activation used for picking up objects, for standing and walking, for controlling bladder emptying, and for breathing. Despite substantial progress in development and new knowledge, many challenges remain to be resolved to provide a more efficient functionality of FES systems. The most important task of these challenges is to improve control of the activated muscles through open loop or feedback systems. Command and feedback signals can be extracted from biopotentials recorded from muscles (Electromyogram, EMG), nerves (Electroneurogram, ENG), and the brain (Electroencephalogram (EEG) or individual cells). This paper reviews work in which EMG, ENG, and EEG signals in humans have been used as command and feedback signals in systems using electrical stimulation of motor nerves to restore movements after an injury to the Central Nervous System (CNS). It is concluded that the technology is ready to push for more substantial clinical FES investigations in applying muscle and nerve signals. Brain-computer interface systems hold great prospects, but require further development of faster and clinically more acceptable technologies.

Action Potentials↗

Dose evaluation and effective dose estimation from multi detector CT.

Computed tomography (CT) has evolved remarkably through device improvement and advancement of peripherals, including computers. In 1999, multi detector-row CT (MDCT) appeared and rapid high-speed scanning became possible. However, usefulness of MDCT in actual clinical application cannot be assessed until the exposure doses are assessed appropriately. Since CT examinations need a comparatively high dose, it is necessary to evaluate patient exposure for introduction of MDCT. Patient doses by three types of MDCTs were evaluated for cases of scanning of the chest and abdomen-pelvis. The examination conditions were the same as those in actual clinical examinations. The obtained effective doses were 9.4-28 mSv for the chest examination and 13-28 mSv for the abdomen-pelvis. The average surface doses varied between 16-43 mGy for the chest examination and 20-37 mGy for the abdomen-pelvis. The highest surface dose was 57 mGy for the abdomen-pelvis examination. The exposed doses differed according to scanning method and imaging conditions such as tube current, slice thickness and so on. It seemed that there is room for dose reduction by proper adjustment of scan conditions in MDCT examinations.

Humans↗

Distal radius: in vivo assessment with quantitative MR imaging, peripheral quantitative CT, and dual X-ray absorptiometry.

PURPOSE: To evaluate in vivo the relationship between magnetic resonance (MR) imaging relaxation time and bone mineral density (BMD) at the distal radius. MATERIALS AND METHODS: The 1/T2* MR imaging relaxation rates and dual X-ray absorptiometry (DXA) measurements were evaluated in the trabecular bone of the distal 5 cm of the radius in 14 healthy premenopausal women and 11 healthy postmenopausal women and in 11 women with osteoporosis. Trabecular and total BMD were measured with peripheral quantitative computed tomography (CT). RESULTS: In healthy women, 1/T2* values and trabecular BMD at peripheral quantitative CT were significantly correlated but 1/T2* and total BMD were not. Statistically significant (P = .03) correlations between 1/T2* and DXA were found only in the most distal area covered with DXA. The 1/T2* values were more closely correlated with age and showed higher relative annual decreases (0.47%-0.81%) than peripheral quantitative CT (0.20%-0.59%) or DXA (0.10%-0.39%). Pre- and postmenopausal healthy subjects could be distinguished only with MR imaging, and postmenopausal healthy and osteoporotic subjects only with CT and DXA. CONCLUSION: MR imaging relaxation rates correlate well with trabecular BMD in vivo.

Absorptiometry, Photon↗

The cumulative verification image analysis tool for offline evaluation of portal images.

PURPOSE: Daily portal images acquired using electronic portal imaging devices contain important information about the setup variation of the individual patient. The data can be used to evaluate the treatment and to derive correction for the individual patient. The large volume of images also require software tools for efficient analysis. This article describes the approach of cumulative verification image analysis (CVIA) specifically designed as an offline tool to extract quantitative information from daily portal images. METHODS AND MATERIALS: The user interface, image and graphics display, and algorithms of the CVIA tool have been implemented in ANSCI C using the X Window graphics standards. The tool consists of three major components: (a) definition of treatment geometry and anatomical information; (b) registration of portal images with a reference image to determine setup variation; and (c) quantitative analysis of all setup variation measurements. The CVIA tool is not automated. User interaction is required and preferred. Successful alignment of anatomies on portal images at present remains mostly dependent on clinical judgment. Predefined templates of block shapes and anatomies are used for image registration to enhance efficiency, taking advantage of the fact that much of the tool's operation is repeated in the analysis of daily portal images. RESULTS: The CVIA tool is portable and has been implemented on workstations with different operating systems. Analysis of 20 sequential daily portal images can be completed in less than 1 h. The temporal information is used to characterize setup variation in terms of its systematic, random and time-dependent components. The cumulative information is used to derive block overlap isofrequency distributions (BOIDs), which quantify the effective coverage of the prescribed treatment area throughout the course of treatment. Finally, a set of software utilities is available to facilitate feedback of the information for treatment plan recalculation and to test various decision strategies for treatment adjustment. CONCLUSIONS: The CVIA tool provides comprehensive analysis of daily images acquired with electronic portal imaging devices. Its offline approach allows characterization of the nature of setup variation for the individual patient that would have been difficult to deduce using only a few daily or weekly portal images. Distribution of the tool will help establish an important database of setup variation from many clinics. The information derived from CVIA can also serve as the foundation to integrate treatment verification, treatment planning, and treatment delivery.

Computer Peripherals↗