PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Fractures, Comminuted”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16Linked to original sources

[External fixation of comminuted fractures of the distal extremity of the radius : technical details (author's transl)].

Experience gained by the authors in the use of external metacarpo-radial fixation for compound fractures of the lower extremity of the radius has led to their proposal of a technique that is less aggressive to the soft tissues. They employ a systematic approach to the radius and second metacarpal, followed by the use of atraumatic plates applied by means of a simple screw.

Fracture Fixation↗

[Simple, complete, and comminuted fractures of the sternum. Analysis of 14 cases with osteosynthesis].

The authors report 14 cases of fractured sternum operated upon in thoracic surgery at United Hospital in Foggia. Most of the ostheosynthesis of the sternum were done with two Patellar set sutures. The follow-up revealed good stabilization of the thoracic cage and good alignment of the fractured site. Postoperative respiratory distress was never noted, neither was thoracotomy ever required.

Adult↗

A modification of the use of extraskeletal immobilization for comminuted fractures of the distal radius.

The patients selected for this modification of the Roger Anderson device are few, because the method is intended for unstable fractures of the distal radius. Extensive disabling stiffening of the wrist and hand encountered following prolonged immobilization by rigid distraction methods can be avoided or greatly reduced by this simple modification of the method. This modification of the extraskeletal fixation should prove to be superior to rigid distraction when early decompression of the carpal tunnel is indicated.

Fracture Fixation↗

Hybrid external fixation of comminuted tibial plateau fractures.

Comminuted tibial plateau fractures present a surgical challenge to the orthopaedic surgeon. Over the years, treatment has ranged from traction to cast immobilization to open reduction and internal fixation. More recently, indirect reduction techniques with external fixation have been used. At the authors' institution, from 1990 to 1992, 18 Schatzker Types V and VI tibial plateau fractures were treated in 18 patients with indirect reduction and application of a Monticelli-Spinelli hybrid external fixation system. Two patients had additional internal fixation and were excluded from this review. All 16 patients were available for followup evaluation. The mean time to union was 4.5 months. There were no nonunions. Three patients developed a varus deformity. Fifteen had radiographic evidence of early degenerative changes at 1 year followup. There were 11 superficial pin tract infections in 4 patients; all resolved with local pin care and a short course of oral antibiotics. There were no deep infections. With the added advantages of minimal to no soft tissue stripping and early knee range of motion, this technique is recommended for treatment of these difficult fractures.

Adult↗

Distraction pinning for radial metaphysis fractures.

Comminuted fractures of the distal radial metaphysis are inherently unstable. Reduction can be obtained utilizing traction, and then the fracture stabilized by placing pins proximal and distal to the fracture and incorporating these pins in a short-arm cast. The results of 36 patients treated in this manner were analyzed. An excellent result was achieved in 78% of the cases.

Bone Nails↗

Comminuted distal radius fractures.

Comminuted displaced fractures of the distal end of the radius pose a significant treatment challenge. The goal of treatment is to restore functional, painless motion of the wrist and fingers. Although satisfactory results correlate to a large extent with obtaining and maintaining normal anatomy, excessive distraction and a flexed wrist position with external fixation cause more harm than good, even if the anatomy is restored.

External Fixators↗

Comminuted femoral shaft fractures.

Comminuted femoral shaft fractures are often grouped with more simple femoral fractures for study. Although union always occurs, shortening and angulation can result from closed treatment using traction and cast bracing. Operative intervention using locked intramedullary nails can lead to a consistently excellent outcome when the performance of the procedure is technically correct. The surgical procedure can eliminate a difficult management problem in multiply-injured patients.

Bone Nails↗

Role of formalin-preserved allograft in fresh fractures with comminution.

The use of bone grafting in polytrauma patients is associated with significant problems. Additional surgical time is required for the use of cancellous autografts, and there may be a significant incidence of donor site morbidity. Various types of allografts used in western countries are expensive to obtain and store, and the technical know-how required for their use may not be available in Third World countries. A series is reported in which formalin-preserved allograft (FPA) was used for the management of comminuted fractures in 22 polytrauma cases. This type of allograft is inexpensive, easy to prepare and store, and has been shown in experimental and clinical studies to be nonantigenic and sterile. The complication rate and time to union were comparable with a control series of autografted cases and previously reported series in the literature. Based on the results in this series of patients, the use of FPA is recommended for the grafting of multiple fractures, especially when other forms of allograft are not available because of technical or financial limitations.

Adolescent↗