Improved native UV laser induced fluorescence detection for single cell analysis in poly(dimethylsiloxane) microfluidic devices.

Single cell analytics is a key method in the framework of proteom research allowing analyses, which are not subjected to ensemble-averaging, cell-cycle or heterogeneous cell-population effects. Our previous studies on single cell analysis in poly(dimethylsiloxane) microfluidic devices with native label-free laser induced fluorescence detection [W. Hellmich, C. Pelargus, K. Leffhalm, A. Ros, D. Anselmetti, Electrophoresis 26 (2005) 3689] were extended in order to improve separation efficiency and detection sensitivity. Here, we particularly focus on the influence of poly(oxyethylene) based coatings on the separation performance. In addition, the influence on background fluorescence is studied by the variation of the incident laser power as well as the adaptation of the confocal volume to the microfluidic channel dimensions. Last but not least, the use of carbon black particles further enhanced the detection limit to 25 nM, thereby reaching the relevant concentration ranges necessary for the label-free detection of low abundant proteins in single cells. On the basis of these results, we demonstrate the first electropherogram from an individual Spodoptera frugiperda (Sf9) cell with native label-free UV-LIF detection in a microfluidic chip.

Animals↗

High-resolution chiral separation using microfluidics-based membrane chromatography.

A plastic microfluidic system, containing porous poly(vinylidene fluoride) (PVDF) membranes adsorbed with bovine serum albumin (BSA), is demonstrated for high resolution chiral separation of racemic tryptophan and thiopental mixtures. Microfluidic networks on poly(dimethylsiloxane) (PDMS) substrates are fabricated by capillary molding technique. This miniaturized chiral separation system consists of two layers of PVDF membranes which are sandwiched between two PDMS slabs containing microchannels facing the membranes. On-line adsorption of BSA onto the membranes is employed for the preparation of chiral stationary phase and the evaluation of solution conditions in an effort to achieve maximum protein adsorption. Variations in the mobile phase conditions, including solution pH and ammonium sulfate concentration, are studied for their effects on chiral separation. Based on the large surface area to volume ratio of porous membrane media, adsorbed BSA onto the PVDF membranes enables high resolution separation of racemic mixtures with sample consumption of sub-nanogram or less in the integrated microfluidic networks. In addition, the membrane pore diameter in the submicron range eliminates the constraints of diffusional mass-transfer resistance during protein adsorption and chiral chromatographic processes.

Adsorption↗

Surface passivation of a microfluidic device to glial cell adhesion: a comparison of hydrophobic and hydrophilic SAM coatings.

Cell adhesion in a microfluidic structure can lead to catastrophic flow problems due to the comparable size of the cell with the microfabricated device. Such issues are important in the growing research area involving the merging of biological materials and MEMS devices. We have examined the surface compatibility of uncoated and coated microfabricated glass and semiconductor surfaces under static solution (cell culture) and flow experiments (microfluidic device) using glial (astrocyte and glioblastoma) cells. Bare semiconductor and glass surfaces were most attractive to cell adhesion, promoting biofouling under both static and flow conditions. Passivation of the surfaces was performed with silane coupling agents octadecyltrimethoxysilane (OTMS) or N-(triethoxysilylpropyl)-O-polyethylene oxide urethane (TESP) on SiO2 surfaces via self-assembled monolayer (SAM) deposition. The hydrophilic TESP coating was effective at inhibiting biofouling of the microfluidic structure, allowing greater than several minutes of fluid flow. The hydrophobic OTMS coating, on the other hand, promoted cell adhesion leading to restricted flow within a few minutes. Interestingly, under cell culture conditions the TESP surface exhibited biocompatible properties for glial cell adhesion and proliferation, in contrast to the OTMS surface which resisted cell growth. These studies suggest that cell adhesion is dependent upon the time domain of the cell-surface interaction.

Astrocytes↗

Generation of natural pH gradients in microfluidic channels for use in isoelectric focusing

As a part of an ongoing investigation of the use of isoelectric focusing (IEF) in microfluidic devices, pH gradients were electrochemically formed and optically quantified in microfluidic channels using acid-base indicators. The microchannels consisted of two parallel 40-mm-long electrodes with an interelectrode gap of 2.54 mm; top and bottom transparent windows were separated by 0.2 mm. Gradients in pH were formed as a result of the electrochemical decomposition of water at an applied potential not higher than 2.5 V to avoid generation of gas bubbles. Solutions contained low concentrations of a single buffer. The stability of the pH gradients and their sensitivity to changes in initial conditions were investigated under static (nonflow) conditions. Isoelectric focusing of sample biological analytes, bovine hemoglobin and bovine serum albumin, was performed to illustrate the potential of "microfluidic transverse IEF" for use in continuous concentration and separation systems.

Journal Article↗

Voltammetry on microfluidic chip platforms

Microfluidic chip devices are shown to be attractive platforms for performing microscale voltammetric analysis and for integrating voltammetric procedures with on-chip chemical reactions and fluid manipulations. Linear-sweep, square-wave, and adsorptive-stripping voltammograms are recorded while electrokinetically "pumping" the sample through the microchannels. The adaptation of voltammetric techniques to microfluidic chip operation requires an assessment of the effect of relevant experimental variables, particularly the high voltage used for driving the electroosmotic flow, upon the background current, potential window, and size or potential of the voltammetric signal. The exact potential window of the chip detector is dependent upon the driving voltage. Manipulation of the electroosmotic flow opens the door to hydrodynamic modulation (stopped-flow) and reversed-flow operations. The modulated analyte velocity permits compensation of the microchip voltammetric background. Reversal of the driving voltage polarity offers extended residence times in the detector compartment. Rapid square-wave voltammetry/flow injection operation allows a detection limit of 2 x 10(-12) mol (i.e., 2 pmol) of 2,4,6-trinitrotoluene (TNT) in connection with 47 nL of injected sample. The ability of integrating chemical reactions with voltammetric detection is demonstrated for adsorptive stripping measurements of trace nickel using the nickel-dimethylglyoxime model system. The voltammetric response is characterized using catechol, hydrazine, TNT, and nickel as test species. The ability to perform on-chip voltammertic protocols in advantageous over nanovial voltammetric operations that lack a liquid-handling capability. Coupling the versatility of microfluidic chips with the rich information content of voltammetry thus opens an array of future opportunities.

Journal Article↗

Formation of natural pH gradients in a microfluidic device under flow conditions: model and experimental validation.

A new isoelectric focusing technique has been developed that incorporates natural pH gradient formation in microfluidic channels under flowing conditions. In conjunction, a one-dimensional finite difference model has been developed that solves a system of algebraic-ordinary differential equations that describe the phenomena occurring in the system, including hydrolysis at the electrodes, buffering effects of weak acids and bases, and mass transport due to both diffusion and electrophoresis. A quantitative, noninvasive, optically based method of monitoring pH gradient formation is presented, and the experimental data generated by this method are found to be in good agreement with model predictions. In addition, the model provides a theoretical explanation for initially unexpected experimental results. Model predictions are also shown to match well with experimental results of microfluidic isoelectric focusing of a single protein species. Accounting for the nonuniform velocity profile, characteristic of pressure-driven flow in microfluidic channels, is found to improve predictions of dynamic pH changes close to the electrodes and overall time required to reach steady state, but to reduce the accuracy of dynamic pH change predictions in other regions of the channel.

Journal Article↗

Development of a multichannel microfluidic analysis system employing affinity capillary electrophoresis for immunoassay.

A six-channel microfluidic immunoassay device with a scanned fluorescence detection system is described. Six independent mixing, reaction, and separation manifolds are integrated within one microfluidic wafer, along with two optical alignment channels. The manifolds are operated simultaneously and data are acquired using a singlepoint fluorescence detector with a galvano-scanner to step between separation channels. A detection limit of 30 pM was obtained for fluorescein with the scanning detector, using a 7.1-Hz sampling rate for each of the reaction manifolds and alignment channels (57-Hz overall sampling rate). Simultaneous direct immunoassays for ovalbumin and for anti-estradiol were performed within the microfluidic device. Mixing, reaction, and separation could be performed within 60 s in all cases and within 30 s under optimized conditions. Simultaneous calibration and analysis could be performed with calibrant in several manifolds and sample in the other manifolds, allowing a complete immunoassay to be run within 30 s. Careful chip conditioning with methanol, water, and 0.1 M NaOH resulted in peak height RSD values of 3-8% (N = 5 or 6), allowing for cross-channel calibration. The limit of detection (LOD) for an anti-estradial assay obtained in any single channel was 4.3 nM. The LOD for the cross-channel calibration was 6.4 nM. Factors influencing chip and detection system design and performance are discussed in detail.

Journal Article↗

Control of flow direction in microfluidic devices with polyelectrolyte multilayers.

Electroosmotic flow (EOF) is commonly utilized in microfluidics. Because the direction of the EOF can be determined by the substrate surface charge, control of the surface chemical state offers the potential, in addition to voltage control, to direct the flow in microfluidic devices. We report the use of polyelectrolyte multilayers (PEMs) to alter the surface charge and control the direction of flow in polystyrene and acrylic microfluidic devices. Relatively complex flow patterns with simple arrangements of applied voltages are realized by derivatization of different arms of a single device with oppositely charged polyelectrolytes. In addition, flow in opposite directions in the same channel is possible. A positively derivatized plastic substrate with a negatively charged lid was used to achieve top-bottom opposite flows. Derivatization of the two sides of a plastic microchannel with oppositely charged polyelectrolytes was used to achieve side-by-side opposite flows. The flow is characterized using fluorescence imaging and particle velocimetry.

Journal Article↗

Integrated microfluidic system enabling protein digestion, peptide separation, and protein identification.

An integrated platform is presented for rapid and sensitive protein identification by on-line protein digestion and analysis of digested proteins using electrospray ionization mass spectrometry or transient capillary isotachophoresis/capillary zone electrophoresis with mass spectrometry detection. A miniaturized membrane reactor is constructed by fabricating the microfluidic channels on a poly(dimethylsiloxane) substrate and coupling the microfluidics to a poly(vinylidene fluoride) porous membrane with the adsorbed trypsin. On the basis of he large surface area-to-volume ratio of porous membrane media, adsorbed trypsin onto the poly(vinylidene fluoride) membrane is employed for achieving ultrahigh catalytic turnover. The extent of protein digestion in a miniaturized membrane reactor can be directly controlled by the residence time of protein analytes inside the trypsin-adsorbed membrane, the reaction temperature, and the protein concentration. The resulting peptide mixtures can either be directly analyzed using electrospray ionization mass spectrometry or further concentrated and resolved by electrophoretic separations prior to the mass spectrometric analysis. This microfluidic system enables rapid identification of proteins in minutes instead of hours, consumes very little sample (nanogram or less), and provides on-line interface with upstream protein separation schemes for the analysis of complex protein mixtures such as cell lysates.

Adsorption↗

A method for filling complex polymeric microfluidic devices and arrays.

This paper describes an improved method for filling microfluidic structures with aqueous solutions. The method, channel outgas technique (COT), is based on a filling procedure carried out at reduced pressures. This procedure is compared with previously reported methods in which microfluidic channels are filled either by using capillary forces or by applying a pressure gradient at one or more empty reservoirs. The technique has proven to be > 90% effective in eliminating the formation of bubbles within microfluidic networks. It can be applied to many devices, including those containing PDMS-terminated channel features, a single channel inlet, and three-dimensional arrays.

Journal Article↗

Integrated plastic microfluidic devices with ESI-MS for drug screening and residue analysis.

For this work, two different plastic microfluidic devices are designed and fabricated for applications in high-throughput residue analysis of food contaminants and drug screening of small-molecule libraries. Microfluidic networks on copolyester and poly(dimethylsiloxane) substrates are fabricated by silicon template imprinting and capillary molding techniques. The first device is developed to perform affinity capture, concentration, and direct identification of targeted compounds using electrospray ionization mass spectrometry. Poly(vinylidene fluoride) membranes sandwiched between the imprinted copolyester microchannels in an integrated platform provide continuous affinity dialysis and concentration of a reaction mixture containing aflatoxin B1 antibody and aflatoxins. The second microfluidic device is composed of microchannels on the poly(dimethylsiloxane) substrates. The device is designed to perform miniaturized ultrafiltration of affinity complexes of phenobarbital antibody and barbiturates, including the sequential loading, washing, and dissociation steps. These microfabricated devices not only significantly reduce dead volume and sample consumption but also increase the detection sensitivity by at least 1-2 orders of magnitude over those reported previously. Improvements in detection sensitivity are attributed to analyte preconcentration during the affinity purification step, limited analyte dilution in the microdialysis junction, minimal sample loss, and the amenability of ESI-MS to nanoscale sample flow rates.

Aflatoxin B1↗

Detection of viable Cryptosporidium parvum using DNA-modified liposomes in a microfluidic chip.

This paper describes a microfluidic chip that enables the detection of viable Cryptosporidium parvum by detecting RNA amplified by nucleic-acid-sequence-based amplification (NASBA). The mRNA serving as the template for NASBA is produced by viable C. parvum as a response to heat shock. The chip utilizes sandwich hybridization by hybridizing the NASBA-generated amplicon between capture probes and reporter probes in a microfluidic channel. The reporter probes are tagged with carboxyfluorescein-filled liposomes. These liposomes, which generate fluorescence intensities not obtainable from single fluorophores, allow the detection of very low concentrations of targets. The limit of detection of the chip is 5 fmol of amplicon in 12.5 microL of sample solution. Samples of C. parvum that underwent heat shock, extraction, and amplification by NASBA were successfully detected and clearly distinguishable from controls. This was accomplished without having to separate the amplified RNA from the NASBA mixture. The microfluidic chip can easily be modified to detect other pathogens. We envision its use in mu-total analysis systems (mu-TAS) and in DNA-array chips utilized for environmental monitoring of pathogens.

Animals↗

An integrated fluorescence detection system in poly(dimethylsiloxane) for microfluidic applications.

This paper describes a prototype of an integrated fluorescence detection system that uses a microavalanche photodiode (microAPD) as the photodetector for microfluidic devices fabricated in poly(dimethylsiloxane) (PDMS). The prototype device consisted of a reusable detection system and a disposable microfluidic system that was fabricated using rapid prototyping. The first step of the procedure was the fabrication of microfluidic channels in PDMS and the encapsulation of a multimode optical fiber (100-microm core diameter) in the PDMS; the tip of the fiber was placed next to the side wall of one of the channels. The optical fiber was used to couple light into the microchannel for the excitation of fluorescent analytes. The photodetector, a prototype solid-state microAPD array, was embedded in a thick slab (1 cm) of PDMS. A thin (80 microm) colored polycarbonate filter was placed on the top of the embedded microAPD to absorb scattered excitation light before it reached the detector. The microAPD was placed below the microchannel and orthogonal to the axis of the optical fiber. The close proximity (approximately 200 microm) of the microAPD to the microchannel made it unnecessary to incorporate transfer optics; the pixel size of the microAPD (30 microm) matched the dimensions of the channels (50 microm). A blue light-emitting diode was used for fluorescence excitation. The microAPD was operated in Geiger mode to detect the fluorescence. The detection limit of the prototype (approximately 25 nM) was determined by finding the minimum detectable concentration of a solution of fluorescein. The device was used to detect the separation of a mixture of proteins and small molecules by capillary electrophoresis; the separation illustrated the suitability of this integrated fluorescence detection system for bioanalytical applications.

Carbonic Anhydrases↗

Performance of an integrated microoptical system for fluorescence detection in microfluidic systems.

This article presents a new integrated microfluidic/microoptic device designed for basic biochemical analysis. The microfluidic network is wet-etched in a Borofloat 33 (Pyrex) glass wafer and sealed by means of a second wafer. Unlike other similar microfluidic systems, elements of the detection system are realized with the help of microfabrication techniques and directly deposited on both sides of the microchemical chip. The detection system is composed of the combination of refractive circular or elliptical microlens arrays and chromium aperture arrays. The microfluidic channels are 60 microm wide and 25 microm deep. The elliptical microlenses have a major axis of 400 microm and a minor axis of 350 microm. The circular microlens diameters range from 280 microm to 350 microm. The apertures deposited on the outer chip surfaces are etched in a 3000-A-thick chromium layer. The overall thickness of this microchemical system is < 1.6 mm. A limit of detection of 3.3 nM for a Cy5 solution in phosphate buffer (pH 7.4) was demonstrated. The cross-talk signal measured between two adjacent microchannels with 1 mm pitch was < 1:5600, meaning that < or = 1.8 x 10(-4)% of the fluorescence light power emitted from one microchannel filled with a 50 microM Cy5 solution reaches the photodetector at the adjacent microchannel. This performance compares very well with that obtainable in microchemical chips using confocal fluorescence systems, taking differences in parameters, such as excitation power into microchannels, data acquisition rates, and signal filtering into account.

Journal Article↗

An electrospray ionization source for integration with microfluidics.

We have demonstrated a new electrospray ionization (ESI) device incorporating a tip made from a shaped thin film, bonded to a microfluidic channel, and interfaced to a time-of-flight mass spectrometer (TOFMS). A triangular-shaped thin polymer tip was formed by lithography and etching. A microfluidic channel, 20 microm wide and 10 microm deep, was embossed in a cyclo olefin substrate using a silicon master. The triangular tip was aligned with the channel and bonded between the channel plate and a flat plate to create a microfluidic channel with a wicking tip protruding from the end. This structure aided the formation of a stable Taylor cone at the apex of the tip, forming an electrospray ionization source. This source was tested by spraying several solutions for mass spectrometric analysis. Because the components are all made by lithographic approaches with high geometrical fidelity, an integrated array system with multiple channels can be formed with the same method and ease as a single channel. We tested a multichannel system in a multiplexed manner and showed reliable operation with no significant cross contamination between closely spaced channels.

Cytochrome c Group↗

Microarrays assembled in microfluidic chips fabricated from poly(methyl methacrylate) for the detection of low-abundant DNA mutations.

Low-density arrays were assembled into microfluidic channels hot-embossed in poly(methyl methacrylate) (PMMA) to allow the detection of low-abundant mutations in gene fragments (K-ras) that carry point mutations with high diagnostic value for colorectal cancers. Following spotting, the chip was assembled with a cover plate and the array accessed using microfluidics in order to enhance the kinetics associated with hybridization. The array was configured with zip code sequences (24-mers) that were complementary to sequences present on the target. The hybridization targets were generated using an allele-specific ligase detection reaction (LDR), in which two primers (discriminating primer that carriers the complement base to the mutation being interrogated and a common primer) that flank the point mutation and were ligated joined together) only when the particular mutation was present in the genomic DNA. The discriminating primer contained on its 5'-end the zip code complement (directs the LDR product to the appropriate site of the array), and the common primer carried on its 3' end a fluorescent dye (near-IR dye IRD-800). The coupling chemistry (5'-amine-containing oligonucleotide tethered to PMMA surface) was optimized to maximize the loading level of the zip code oligonucleotide, improve hybridization sensitivity (detection of low-abundant mutant DNAs in high copy numbers of normal sequences), and increase the stability of the linkage chemistry to permit re-interrogation of the array. It was found that microfluidic addressing of the array reduced the hybridization time from 3 h for a conventional array to less than 1 min. In addition, the coupling chemistry allowed reuse of the array > 12 times before noticing significant loss of hybridization signal. The array was used to detect a point mutation in a K-ras oncogene at a level of 1 mutant DNA in 10,000 wild-type sequences.

DNA↗

Cell docking and on-chip monitoring of cellular reactions with a controlled concentration gradient on a microfluidic device.

We have developed a microfluidic device for on-chip monitoring of cellular reactions. The device consists of two primary analytical functions: control of cell transport and immobilization, and dilution of an analyte solution to generate a concentration gradient. In this device, a dam structure in parallel to the fluid flow was constructed for docking and alignment of biological cells, which allows the fragile cells to move in the microfluidic channels and to be immobilized with controllable numbers in desired locations. The cells docked on the parallel dam structure are exposed to minimal stress caused by fluidic pressure. Additionally, a network of microfluidic channels was designed to generate a concentration gradient by controlled fluid distribution and diffusive mixing. An analyte solution could be diluted to different gradients as a function of distance along the dam. We used the ATP-dependent calcium uptake reaction of HL-60 cells as a model for on-chip measurement of the threshold ATP concentration that induces significant intracellular calcium signal. The results have demonstrated the feasibility of using the microchip for real-time monitoring of cellular processes upon treatment of a concentration gradient of a test solution. The integration of cell manipulation and solution manipulation on a microchip allows the measurement of concentration-dependent biological responses within a confined microscale feature.

Adenosine Triphosphate↗

High-pressure microfluidic control in lab-on-a-chip devices using mobile polymer monoliths.

We have developed a nonstick polymer formulation for creating moving parts inside of microfluidic channels and have applied the technique to create piston-based devices that overcome several microfluidic flow control challenges. The parts were created bycompletely filling the channels of a glass microfluidic chip with the monomer/ solvent/initiator components of a nonstick photopolymer and then selectively exposing the chip to UV light in order to define mobile pistons (or other quasi-two-dimensional shapes) inside the channels. Stops defined in the substrate prevent the part from flushing out of the device but also provide sealing surfaces so that valves and other flow control devices are possible. Sealing against pressures greater than 30 MPa (4,500 psi) and actuation times less than 33 ms are observed. An on-chip check valve, a diverter valve, and a 10-nL pipet are demonstrated. This valving technology, coupled with high-pressure electrokinetic pumps, should make it possible to create a completely integrated HPLC system on a chip.