PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “PHOSPHORESCENCE”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16Linked to original sources

Evaluation of low-scaling methods for calculation of phosphorescence parameters.

In order to find a methodology that is a compromise between favorable computational scaling and tolerable errors, a series of nonrelativistic approaches for the calculation of radiative phosphorescence lifetimes are benchmarked against fully relativistic four-component results. The study of the a 3A2-X 1A1 transition intensity in the series of H2CX molecules, where X is a chalcogene atom, X={O,S,Se,Te}, indicates a general good agreement between fully relativistic four-component and nonrelativistic perturbation-theoretical calculations. Among the nonrelativistic approaches, the scaled-charge spin-orbit operator approach is recognized as to provide transition matrix elements that are in good agreement with those obtained with the more elaborate Breit-Pauli and atomic mean field spin-orbit operators. This finding supports phosphorescence calculations using the available linear scaling technology for large complexes and, together with effective-core potentials, large complexes including heavy elements.

Journal Article↗

Time-dependent density functional theory investigation of the absorption, fluorescence, and phosphorescence spectra of solvated coumarins.

Using time-dependent density functional theory (TD-DFT) and the polarizable continuum model, we have computed the electronic transitions of a large panel of coumarin dyes in their enol, keto, cationic, and anionic forms. Several processes have been studied: absorption, fluorescence, 0-0 phosphorescence, and triplet-triplet excitations. For each process, detailed comparison with experimental data has been carried out. Using the PBE06-31+G(d) scheme, it turns out that for a given electronic transition the experimental shifts resulting from the substitution of the coumarin core are nicely reproduced. Indeed, once a simple statistical correction is applied, the mean absolute errors on the absorption and fluorescence wavelengths are limited to 8 nm (0.09 eV) and 9 nm (0.07 eV), respectively. A valuable correlation between the experimental and theoretical phosphorescence auxochromic displacements has also been unravelled. The differences between the wavelengths of the various electronic processes of a given dye tend to be fairly predicted, especially for the fluorescence-phosphoresence shifts that are strongly overestimated by TD-DFT.

Journal Article↗

Rotational diffusion of cell surface components by time-resolved phosphorescence anisotropy.

The rotational diffusion of concanavalin A receptors of viable Friend erythroleukemia cells and the band 3 anion transport system of human erythrocytes has been measured via the time-dependent phosphorescence emission intensity and anisotropy of triplet probes excited by a 5-ns laser pulse. High-quality phosphorescence decay curves with a 10-microseconds time resolution were obtained at concentrations of the eosin probe down to 20 nM and in aqueous media at temperatures of 4-38 degrees C. A strong temperature dependence in the rotational behavior was observed for the band 3 anion transport protein, but the lectin receptors of the Friend erythroleukemia cells were found to be immobile on the time scale of 1-4000 microseconds at either 4 degrees C or 37 degrees C. The technique is applicable to other triplet probes and membrane components of living cells under conditions that do not destroy viability.

Concanavalin A↗

Long-range electron exchange measured in proteins by quenching of tryptophan phosphorescence.

Ten proteins that span a wide range of phosphorescence lifetimes were examined for sensitivity to quenching by four agents of disparate chemical nature. The results show that quenching efficiency is relatively independent of the quencher and is highly correlated with depth of burial of the phosphorescent tryptophan. The bimolecular quenching rate constants (kq) measured for the different proteins, spanning 5 orders of magnitude in kq, are found to decrease exponentially with the distance (r) of the tryptophan in angstroms from the protein surface--i.e., kq = Aexp(-r/rho), where A contains a geometrical factor dependent on tryptophan burial and surface geometry [corrected]. Theoretical analysis shows that this behavior can be expected for an electron-exchange reaction between the buried tryptophans and quenchers in solution in the rapid diffusion limit. Therefore, the results obtained provide evidence for an exponential dependence of electron-transfer rate on distance in a protein environment and evaluate the distance parameter, rho, for electron transfer through the general protein matrix at 1.0 A. For a unimolecular donor-acceptor pair with ket = koexp(-r/rho), ko approximately 10(9) sec-1.

Enzymes↗

Ultraviolet-induced thermoluminescence and phosphorescence in Mg2SiO4:Tb.

Among the common TLD materials studied (Mg2SiO4:Tb, Al2O3:Si, Ti, CaSO4:Tm, CaSO4:Dy, Li2B4O7:Mn and LiF TLD-100), Mg2SiO4:Tb was found to have the highest intrinsic TL sensitivity to UV radiation (wavelength 253.7 nm). The TL response of the dosimetric peak (approximately 200 degrees C) of virgin Mg2SiO4:Tb was studied as a function of UV exposure in the range 10--10(4) J m-2. The UV-induced TL was not affected by room-light and no appreciable fading was observed up to 20 days after irradiation indicating that this is a promising TL phosphor for UV dosimetry. The UV sensitivity was found to increase with increasing preliminary gamma exposure above 10(-2)Ckg-1 (after a post-irradiation anneal at 300 degrees C for 1 h). The degree of sensitisation was found proportional to the intensity of the residual TL peak at 450 degrees C. A study of the TL response of the sensitised sample as a function of UV test exposure has demonstrated the transfer of charge carriers from the deep traps to the dosimetry traps. Both virgin and gamma-exposed Mg2SiO4:Tb were found to exhigit phosphorescence decay at room temperature after UV stimulation. The intensity of the UV stimulated phosphorescence was found to increase with the gamma exposure above 10(-2) C kg-1.

Aluminum Oxide↗

Synthesis and evaluation of phosphorescent oligonucleotide probes for hybridisation assays.

Monofunctional, p-isothiocyanatophenyl-derivatives of platinum (II)-coproporphyrin-I (PtCP-NCS) were evaluated as phosphorescent labelling reagents for synthetic oligonucleotides containing a 3'- or 5'-amino modification. Synthesis and purification conditions were optimised to generate high yields and purity of PtCP-labelled oligonucleotide probes. Phosphorescent properties of the PtCP label have been shown to be largely unaffected by conjugation to oligonucleotides of various length, GC composition and label attachment site. 5'-PtCP-labelled oligonucleotides were shown to work efficiently as primers in a standard PCR. A dedicated 532 nm laser-based time-resolved fluorescence plate reader enabled highly sensitive detection of PtCP-labelled oligonucleotides and PCR products, both in solution and in agarose gels, with limits of detection in the order of 0.3 pM. A model system employing two complementary oligonucleotides labelled with PtCP and QSY 7 dye (dark quencher) showed strong (approximately 20-fold) and specific proximity quenching of PtCP label upon hybridisation in solution. The potential applications of PtCP-labelled probes in hybridisation assays were discussed.

Luminescent Measurements↗

Phosphorescence of pi-conjugated oligomers and polymers.

We observed phosphorescence from a ladder-type poly-(para-phenylene) and an analogous oligomer containing five phenylene rings. The spectra are similar to the intrinsic fluorescence spectra and bear out a singlet-triplet splitting of 5000 cm(-1) (polymer) and 6800 cm(-1) (oligomer). Phosphorescence decay of the polymer occurs on a 10-100-micros scale obeying a power law and suggestive of nonradiative quenching, while that of the oligomer is asymptotically exponential with an intrinsic decay time of approximately 250 ms. The polymer also exhibits delayed fluorescence. It originates from delayed recombination of geminate electron-hole pairs rather than from triplet-triplet annihilation.

Journal Article↗

Intermolecular interaction and a concentration-quenching mechanism of phosphorescent Ir(III) complexes in a solid film.

Solid-state self-quenching processes of highly efficient Ir(III) phosphorescent emitters are investigated by the measurement of thin film photoluminescence quantum efficiency and transient lifetime as a function of doping concentration in a host matrix. The radiative decay rate constant is found to be independent from the average distance between dopant molecules (R), and the concentration-quenching rate constant is shown to be dependent on R(-6). The quenching dependence on R strongly suggests that luminescent concentration quenching in a phosphorescent Ir(III) complex:host film is controlled by dipole-dipole deactivating interactions as described by the Förster energy transfer model.

Journal Article↗

Phosphorescence evidence for the role of solvent--protein interactions in the energetics of conformational flexibility of liver alcohol dehydrogenase.

When tryptophyl side chains are hidden within relatively inflexible domains of globular proteins, the lifetime of the phosphorescence from these residues provides a measure of the local conformational flexibility. The phosphorescence decay from the tryptophan buried at the base of the nucleotide-binding domain in liver alcohol dehydrogenase (alcohol:NAD+ oxidoreductase, EC 1.1.1.1) was monitored between 1 and 40 degrees C to determine the energetics associated with the rate of local unfolding. The slow rate at which this process takes place is found to result from a high entropic barrier rather than from the disruption of strong intramolecular interactions. This observation along with the response of the system to solvent perturbations points to the significance of solvent-protein interactions in determining conformational flexibility.

Alcohol Oxidoreductases↗

Rotational mobility associated with the protein moiety of human serum lipoproteins from tryptophan phosphorescence anisotropy measurements.

The steady-state phosphorescence anisotropy of human low density (LDL) and very low density (VLDL) serum lipoproteins in a glycerol--buffer solvent has been investigated. By virtue of the long lifetime of the triplet state, depolarization of the emission resulting from slow rotational motions is observed between -90 and -50 degrees C. Despite the number of emitting residues within these complexes, the rotational behavior can be represented within experimental error by a single correlation time. The magnitude and temperature dependence of the rotational correlation times observed for LDL are consistent with overall rotation of essentially spherical rigid particles as the source of the phosphorescence depolarization. Preliminary data for VLDL indicate the presence of internal peptide motions which are more rapid than those of the overall complex.

Chemical Phenomena↗

Analysis of phosphorescence decay in heterogeneous systems: consequences of finite excitation flash duration.

Analysis of phosphorescence lifetimes using the Stern-Volmer equation is a reliable means of determining quencher concentration for a uniform sample. Methods of analysis for heterogeneous systems are based on the assumption that the excitation is produced by a momentary flash. This condition is an idealization because a real flash has a finite duration and a complex time profile. In the case of a heterogeneous quencher concentration, an excitation flash produces different initial intensities and different times of peak intensity from compartments having different concentrations of quencher. We formulated a model to explore the effects of flash duration on the shape of the emission curve obtained from systems in which the heterogeneity is continuous. We developed mathematical models that can be used to recover fitting parameters of continuous distributions of reciprocal lifetimes approximated as rectangular or Gaussian distributions, or an arbitrary histogram. We also formulated a procedure to convert the distribution of reciprocal lifetimes into a volume distribution of quencher concentration. We found that (1) the Stern-Volmer ratio of phosphorescence intensities cannot be employed for interpretation of pulse phosphorometric data in terms of a volume distribution of quencher; (2) shortening the flash duration decreases the difference of initial intensities between compartments having high and low quencher concentration; (3) the parameters of the volume distribution of quencher concentration can be recovered correctly only after taking account of the difference in initial intensities; and (4) calibration of the initial intensities for a given fitting delay and flash function is necessary.

Kinetics↗

The potential of phosphorescence spectrometry in clinical chemistry--the new generation of instrumentation and methodology.

We review recent advances in instrumentation and methodology in phosphorimetry that should facilitate the use of phosphorimetry for clinical analyses and recent phosphorescence studies of interest to the clinical chemist. We indicate recent advances, particularly improvements in instrumentation, novel methodologies, and new chemical processes that result in either an increase in sensitivity or selectivity (or both) of measurement of compounds of clinical importance. The greatest use of phosphorimetry in the clinical laboratory will not be for the analysis of very large numbers of samples for one species via automatic instrumentation, but rather will be for the analysis of those molecular species difficult or impossible to measure by conventional methods (colorimetry, fluorometry, etc.). Although various instrumental and methodological advances are discussed separately here, the most important use of these advances in clinical chemistry will undoubtedly be when two or more of them are combined, for example, in the use of time- or frequency-resolved phosphorimetry for the selective measurement of the phosphorescence resulting with inorganic probes and the appropriate choice of solvent and pH (of course, the instrument could contain an image vidicon detector for rapid determination of the spectrum, the decay curve, or both).

Antimetabolites↗

Determination of ciprofloxacin with a room-temperature phosphorescence flow-through sensor based on lanthanide-sensitized luminescence.

Direct measurement of the sensitized luminescence of the europium-ciprofloxacin chelate immobilized on a cationic exchanger was used to develop a flow-through room-temperature phosphorescence optosensor for determination of ciprofloxacin. The phosphorescent chelate is formed on-line at room temperature in a flow-injection system and is immobilized on a weakly acidic cation-exchange resin packed in a flow cell. Optimum experimental conditions and analytical performance are discussed in detail. The sensor response for ciprofloxacin was linear, from 1.5 x 10(-6) to 2.0 x 10(-5)M with a relative standard deviation of 2.5% (n = 10) and a detection limit of 1.1 x 10(-7)M. The effect of possible interferences on sensor response was studied. The sensor was successfully tested for the determination of ciprofloxacin in pharmaceutical formulations.

Anti-Infective Agents↗

[Study on the properties of solid substrate room temperature phosphorescence of the antibody labeled with fluorescein isothiocynate].

The properties of room temperature phosphorescence (RTP) of the labeled goat anti-human antibody(with fluorescein isothiocynate GAHAb-FITC) and labeled rabit anti-goat antibody(RAGAb-FITC) with FITC in different dilution ratios on many kinds of solid substrates were studied in detail. It is found that on the polyamide membrane, only using Pb(Ac)2 as a heavy atom perturber, both the labeled antibodies and their antigen-antibody conjugated compound with the human immunoglobulin G remained excellent RTP properties of isothiocyanate fluorescein, lambda ex(max)/lambda em(max) = 525/650 nm, the relation of RTP intensity to the concentration was linear in a certain range. The conditions for immunological reaction and RTP emission were optimized. The result means that it is possible to develop a new immunoassay named as solid substrate room temperature phosphorescence immunoassay (SS-RTP-IA), which combines both the specificity of immunological reaction and high sensitivity of luminescence analysis.

Animals↗

[Studies on non-protected fluid room temperature phosphorescence of phenanthrine].

A strong and stable room temperature phosphorescence (RTP) signal of phenanthrine aqueous solution in the absence of a protecting medium can be induced only by using Na2SO3 as deoxygenator and KI as heavy atom pertuber. The maximum phosphorescence intensity wavelengths are lambda ex/lambda em = 283/482,504 nm. It is also found that the kind and amount of organic solvent added to the luminescent system effects obviously the RTP properties. Under the present of 1% acetonitrile the RTP intensity is linear to phenanthrine concentration in the rage of 8.0 x 10(-7)-6.0 x 10(-6) mol.L-1 and 6.0 x 10(-6) mol.L(-1)-4.0 x 10(-5) mol.L-1, respectively. The detection limit is 2.6 x 10(-8) mol.L-1.

Acetonitriles↗

[Comparative study of room-temperature phosphorescence of 1-bromonaphthalene induced by synergetic effect of nonionic surfactants and beta-cyclodextrin].

Room-temperature phosphorescence of 1-BrN induced by a combination of OPE-10 and Triton X-100 with beta-CD was comparatively studied. In terms of molecular size and dimensions of beta-CD, the octyl group and phenyl group of OPE-10 and Triton X-100 were incorporated into the cavity of beta-CD and the complexes with the stoichiometry of 1:1 were formed. The removal of water molecules inside the cavity results in a greater apolar interior. By enhanced hydrophobic interaction, the cavity occupied by OPE-10 and Triton X-100 is able to further capture another 1-BrN and form close packing 1:1:1 ternary inclusion complexes with apparent stability constant of 1.09 x 10(5) and 4.47 x 10(5) L2 x mol(-2), respectively. 1-BrN shows bright phosphorescence at room temperature due to the greater rigidity in the limited space and the favorable microenvironment shielding from external quenchers and quenching effect on the fluorescence of the phenyl group of OPE-10 and Triton X-100 within the same cavity. In the case of Triton X-100, the larger tert-octyl group better shields off external quenchers such as dissolved oxygen and iodide ion. Energy transfer from the excited phenyl group of Triton X-100 to adjacent 1-BrN acceptor was observed.

Drug Synergism↗

[Increase in the phosphorescence and delayed fluorescence of chlorophyll in barley leaves after selective suppression of carotene biosynthesis].

The action of inhibitors of carotenoid biosynthesis--herbicides SAN 9789 and SAN 6706 on the pigment composition and chlorophyll low temperature (-196 degrees) delayed luminescence (delayed fluorescence and phosphorescence) has been studied in the barley leaves. The herbicides were introduced into etiolated leaves before greening. It is shown that in the mature leaves which were developed in the presence of herbicides biosynthesis of alpha, beta and gamma carotenes is selectively blocked while the concentration of xanthophylls and chlorophylls is not essentially changed. The lack of carotenes is accompanied by an increase of the quantum yields of chlorophyll phosphorescence and delayed fluorescence by the factors of 10 and 6 respectively. The data suggest that carotenes and xanthophylls take an approximately equal part in quenching the chlorophyll triplet states in normal chloroplasts.

Carotenoids↗