PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Polymethacrylic Acids”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16Linked to original sources

Dual-functional biomimetic materials: nonfouling poly(carboxybetaine) with active functional groups for protein immobilization.

We introduce a dual-functional biocompatible material based on zwitterionic poly(carboxybetaine methacrylate) (polyCBMA), which not only highly resists protein adsorption/cell adhesion, but also has abundant functional groups convenient for the immobilization of biological ligands, such as proteins. The dual-functional properties are unique to carboxybetaine moieties and are not found in other nonfouling moieties such as ethylene glycol, phosphobetaine, and sulfobetaine. The unique properties are demonstrated in this work by grafting a polyCBMA polymer onto a surface or by preparing a polyCBMA-based hydrogel. PolyCBMA brushes with a thickness of 10-15 nm were grafted on a gold surface using the surface-initiated atom transfer radical polymerization method. Protein adsorption was analyzed using a surface plasmon resonance sensor. The surface grafted with polyCBMA very largely prevented the nonspecific adsorption of three test proteins, that is, fibrinogen, lysozyme, and human chorionic gonadotropin (hCG). The immobilization of anti-hCG on the surface resulted in the specific binding of hCG while maintaining a high resistance to nonspecific protein adsorption. Transparent polyCBMA-based hydrogel disks were decorated with immobilized fibronectin. Aortic endothelial cells did not bind to the polyCBMA controls, but appeared to adhere well and spread on the fibronectin-modified surface. With their dual functionality and biomimetic nature, polyCBMA-based materials are very promising for their applications in medical diagnostics, biomaterials/tissue engineering, and drug delivery.

Adsorption↗

Fatigue resistance of the bond of a glass-infiltrated alumina ceramic to human dentin.

PURPOSE: To evaluate the fatigue resistance of the bond between dentin and glass-infiltrated alumina ceramic, using different luting protocols. MATERIALS AND METHODS: The null hypothesis is that the fatigue resistance varies with the luting strategy. Forty blocks of In-Ceram Alumina were prepared, and one surface of each block was abraded with 110-microm aluminum oxide particles. Then, the blocks were luted to flat dentin surfaces of 40 human third molars, using 4 different luting strategies (luting system [LS]/ceramic surface conditioning [CSC]) (n=10): (G1) [LS] RelyX-Unicem/[CSC] airborne abrasion with 110-microm Al2O3 particles; (G2) [LS] One-Step + Duo-Link (bis-GMA-based resin)/[CSC] etching with 4% hydrofluoric acid + silane agent; (G3) [LS] ED-Primer + Panavia F (MDP-based resin)/[CSC] Al2O3; (G4) [LS] Scotchbond1+RelyX-ARC (bis-GMA-based resin)/[CSC] chairside tribochemical silica coating (air abrasion with 30-microm SiOx particles + silane). After 24 h of water storage at 37 degrees C, the specimens were subjected to 106 fatigue cycles in shear with a sinusoidal load (0 to 21 N, 8 Hz frequency, 37 degrees C water). A fatigue survivor score was given, considering the number of the fatigue cycles until fracture. The failure modes of failed specimens were observed in a SEM. RESULTS: G3 (score = 5.9, 1 failure) and G4 (score = 6, no failures) were statistically similar (p = 0.33) and had significantly higher fatigue resistance than G1 (score = 3.9, 5 failures) and G2 (score = 3.7, 6 failures) (p < 0.03). SEM analysis of fractured specimens of G1 and G2 showed that almost all the failures were between ceramic and cement. CONCLUSION: The MDP-based resin cement + sandblasting with Al2O3 particles (G3) and bis-GMA-based resin cement + tribochemical silica coating (G4), both using the respective dentin bonding systems, were the best luting protocols for the alumina ceramic. The null hypothesis was confirmed.

Acid Etching, Dental↗

Spatially controlled co-culture of neurons and glial cells.

The ability to create and maintain neuron and glial cell co-cultures is important for neuronal regeneration as well as for fundamental studies on neuron and glial cell interactions. We demonstrate here a method for spatially controlling the arrangement of neurons and glial cells. Line patterns of cell resistant, poly(oligoethyleneglycol methacrylate-co-methacrylic acid), was microcontact printed on various substrates to spatially control the attachment of neurons. Neuron-like cells, PC12 and SH-SY5Y cells, were confined within the unprinted line patterns and extended neurites along the line patterns. Subsequent attachment of glial cells was accomplished by converting the originally cell-resistant line patterns of poly(oligoethyleneglycol methacrylate-co-methacrylic acid) to cell adhesive by electrostatic adsorption of cationic poly-lysine, chitosan, or poly(ethyleneimine). This method for creating patterned co-cultures of neuron and glial cells provides a useful tool for investigating neuron-glial cell interactions and has potential applications in the repair or regeneration of nervous systems.

Animals↗

Novel "plum pudding" gels as potential drug-eluting stent coatings: controlled release of fluvastatin.

This study evaluated novel structural motifs known as "plum pudding" gels as potential drug-eluting stent coatings. Controlled delivery of a HMG-CoA reductase inhibitor (statin) from the intravascular stent surface represents a potential therapeutic modality for prevention of in-stent restenosis (ISR). In this study, gels were comprised of fluvastatin-loaded thermoresponsive microgel particles containing the relatively hydrophilic N-isopropylacrylamide (NiPAAm), mixed with the more hydrophobic N-tert-butylacrylamide (NtBAAm) in different wt/wt ratios: 85/15, 65/35, and 50/50, randomly dispersed in a 65/35 or 85/15 NiPAAm/NtBAAm copolymer matrix. Fluvastatin release from 5 microm copolymer films was greatest from the most hydrophilic systems and least from the more hydrophobic systems. Release from hydrophobic matrices appeared to be via Fickian diffusion, enabling use of the Stokes-Einstein equation to determine diffusion coefficients. Release from hydrophilic matrices was non-Fickian. Eluted drug retained its bioactivity, assessed as selective inhibition of human coronary artery smooth muscle cell proliferation. When stainless steel stent wires were coated (25 microm thickness) with fluvastatin-loaded 65/35 microgels in an 85/15 copolymer matrix, drug elution into static and perfused flow environments followed similar elution profiles. In contrast to elution from copolymer films cast on flat surfaces, diffusion from stent wires coated with hydrophilic and hydrophobic systems both followed Fickian patterns, with slightly larger diffusion coefficients for elution from the flow system. We conclude that manipulation of the relative hydrophobicities of both microgel and matrix components of "plum pudding" gels results in tightly regulated release of fluvastatin over an extended time period relevant to initiation and propagation of ISR.

Anticholesteremic Agents↗

The effect of ceramic and porous fillers on the mechanical properties of experimental dental composites.

OBJECTIVES: The purpose of this study was to investigate the effect of ceramic fillers (containing leucite crystals) and their porosity on the mechanical properties of a new experimental dental composite in order to compare with the properties of composites containing conventional glass fillers. METHODS: In this study, experimental composites were prepared by mixing the silane-treated fillers with monomers. Experimental composites were divided into four groups according to their filler type, amount and porosity. The monomers were composed of 70% Bis-GMA and 30% TEGDMA by weight for all groups. Glass and leucite-containing-ceramic were prepared as different filler types. In order to make fillers porous, leucite-containing-ceramic fillers were treated with HF acid. Camphorquinone and DMAEMA were used as photo initiator system. Post-curing was done for all groups before mechanical testing. Degree of Conversion of composites was measured using FTIR spectroscopy. The diametral tensile strength (DTS), flexural strength and flexural modulus were measured and compared among the groups. RESULTS: The results showed that the stronger and more porous filler has a positive effect on flexural strength. Porosity of filler increased flexural strength significantly. No significant difference was found in DTS tests among the groups. Flexural modulus was affected and increased by using ceramic fillers. The type of the filler affected the DC of the composite and DC increased by post-curing. SIGNIFICANCE: Flexural strength is one of the most important properties of restorative dental materials. Higher flexural strength can be achieved by stronger and more porous fillers. Investigation into the effect of filler on dental material properties would be beneficial in the development of restorative dental material.

Aluminum Silicates↗

Interfacial failure of a dental cement composite bonded to glass substrates.

OBJECTIVES: To measure the interfacial fracture toughness and investigate failure mechanisms of dental cements bound to soda-lime glasses elastically equivalent to dental ceramics, as loading angle changes from 0 to 20 degrees . METHODS: Two half-circle glass discs received surface treatment were bound using dental cement (3M RelyXTM ARC BLBL) to make Brazil-nut sandwich specimens for interfacial toughness testing. Before bonding the two half-circle glass disks, 8% hydrofluoric acid (HF) was applied on the surfaces to bond for 2 min, washed thoroughly for 1 min under tap water and air dried. The surfaces were further treated using silane primer Monobond-s (Vivadent, Liechtenstein) for 60s and air dried. Interfacial toughness as a function of mode mixity was measured using an Instron testing machine by changing loading angels from 0 to 20 degrees . The interfacial fracture surfaces were examined using SEM and EDX to determine the failure modes when loading angles change. RESULTS: Interfacial toughness increases from approximately 1 to 8 J/m/m when loading angle increases from 0 to approximately 20 degrees . Increasing deformation and fracture in dental cement occur when loading angle increases. SIGNIFICANCES: Increasing interfacial toughness can be attributed to more deformation and fracture of dental cement when loading angle increases. Brazil-nut sandwich samples are shown to provide a promising alternative method to evaluate bond strength and interfacial failure for dental restoration. Research was supported by NIH (NYU/PHS No. F5262-07).

Acid Etching, Dental↗

An in vitro investigation of microtensile bond strengths of two dentine adhesives to caries-affected dentine.

OBJECTIVES: To compare the micro-tensile bond strengths of two different adhesive systems (ABF (Clearfil Protect Bond), Kuraray Medical Inc., Tokyo, Japan) and Prime & Bond NT (PBNT, Dentsply, Konstanz, Germany) bonded to caries-affected dentine retained after chemo-mechanical caries removal using Carisolv gel, with that retained after excavation using conventional hand instrumentation. METHOD: Twenty, adult, human extracted carious teeth were used in this split tooth study with bur-cut cavities in sound dentine acting as controls. After clinical caries excavation, the occlusal cavities in each experimental group were restored with either bonding system plus composite. Matchstick-shaped samples through the bond interfaces were sectioned and microtensile bond strengths recorded. Scanning electron microscopy (SEM) was used to ascertain the mode of failure at the restoration-dentine interface. RESULTS: Statistical analysis of the bond strength data showed that for the ABF group, there was no difference in bond strengths between the controls and Carisolv group but these values were significantly higher than those for the hand-excavated samples. PBNT samples showed no significant differences in any of the three test groups, with wider ranging data sets. SEM analysis indicated a variety of failures at the interface including cohesive failures within the caries-affected dentine itself. CONCLUSIONS: From the data generated by this study it could be concluded that microtensile bond strengths of PBNT/composite restorations to caries-affected dentine in clinical cavities were statistically comparable to those to sound dentine. In the ABF/composite restored group (self-etched), the use of conventional hand excavation appeared to weaken the bond strength to the remaining caries-affected dentine. However, the use of Carisolv gel excavation did not compromise bond strengths to caries-affected dentine in either group tested.

Adhesiveness↗

Unique toroidal morphology from composition and sequence control of triblock copolymers.

The mechanism by which the unique toroidal supramolecular assemblies were formed for triblock copolymers of acrylic acid (AA), methyl acrylate (MA), and styrene (S), PAA99-b-PMA73-b-PS66, was probed in this study by investigating the influences of the block copolymer compositions and sequences. Two triblock copolymers, PAA99-b-PMA73-b-PS66 and PAA99-b-PS76-b-PMA62, and two diblock copolymers, PAA99-b-PMA155 and PAA99-b-PS133, were studied under experimental solution-state conditions that involved a range of solvent/nonsolvent (tetrahydrofuran/water) compositions, each in the presence of 2,2'-(ethylenedioxy)bis(ethylamine). The resulting morphologies were determined by transmission electron microscopy. The failures to afford toroidal supramolecular assemblies from both diblock copolymers having comparable lengths of the total hydrophobic chain segment, either entirely PMA or entirely PS, and from the triblock copolymer having a reversed connection sequence for the hydrophobic (PMA and PS) segments demonstrate the unique self-assembly behaviors of triblock copolymers and the importance of the block copolymer sequence.

Acrylic Resins↗

Dentin bond strength of light-cured glass-ionomer cements.

The purpose of this study was to investigate the influence of surface treatments and irradiation conditions on the bond strength of light-cured glass-ionomer cements to dentin. The light-cured glass-ionomer cements used in this study were Vitrabond, XR Ionomer, and Fuji Lining LC. Three experiments were designed to study the influence of the following factors on bond strength to dentin: (1) effect of the surface treatment of the dentin, (2) effect of the irradiation time, (3) effect of an increase in the interval between mixing of the cement and irradiation. Samples were stored in water for 24 hours, after which shear bond testing was performed at a cross-head speed of 1 mm/min. For Vitrabond, the Scotchprep and Gluma 2 treatments gave the greatest shear bond strengths. For XR Ionomer and Fuji Lining LC, the Scotchprep treatment gave the greatest shear bond strengths. The bond strengths for all cements increased with prolonged irradiation time. Bond strengths decreased with a longer elapsed time between mixing and light-curing. This means that light-curing should be done soon after the cement is placed. The failure mode was found to be cohesive in the ionomer.

Acid Etching, Dental↗

Preparation and tabletting of dipyridamole alginate-Eudragit microspheres.

Dipyridamole alginate-Eudragit microspheres were prepared by the emulsification technique of Monshipouri and Price. After modification of the formulation and process variables of this method it was possible to obtain spherical and discrete particles. Microspheres were free flowing and the release of drug was slow compared to granules and powder. To further control the release rate of the drug, tablets of microspheres were prepared, adding 20% HPMC 90 SH 4000 and 90 SH 100,000 and compressing at 98 mPa or 147 mPa. Increasing the amount of additive and the compression pressure decreased the release rate of drug.

Acrylic Resins↗

Development of metal-resin composite restorative material. Part 2. Effects of acid and heat treatments of silver-tin filler particles on flexural properties of metal-resin composite.

The effects of acid and heat treatments of silver-tin filler particles on the flexural properties of metal-resin composite restorative materials were investigated. Five metal-resin composite restorative materials containing different silver-tin filler particles treated under different conditions were experimentally prepared. The conditions of the alloy particles were; 1) as atomized (NT), 2) 1.8% HCl acid-treated (AT), 3) heat-treated at 150 degrees C for 5 min after AT (A15), 4) heat-treated at 200 degrees C for 5 min after AT (A20) and 5) heat-treated at 250 degrees C for 5 min after AT (A25). The flexural strength and the flexural modulus of elasticity were measured for the five metal-resin composites to evaluate the effects of the acid and heat treatments. The flexural strength of the prepared composites was significantly influenced by the surface condition of the filler particles (p < 0.01), and increased significantly when the as atomized particles (NT) were acid-treated (AT) or acid- and heat-treated at 150 degrees C (A15), but then significantly decreased as the heat treatment temperature increased (A20 and A25). The strength of the A15 composite was significantly higher than those of the other composites, and exceeded that (about 60 MPa) of the previous composite with no treatment. No significant difference was found in the flexural modulus of the composites.

Acrylic Resins↗

Development of metal-resin composite restorative material. Part 4. Flexural strength and flexural modulus of metal-resin composite using Ag-In alloy particles as filler.

The flexural strength and flexural modulus of an experimental metal-resin composite, which used Ag-In alloy particle as the filler, were evaluated. The effect of acid treatment and heat treatment on the Ag-In alloy particle was investigated. The flexural strength of the experimental metal-resin composites ranged from 65.5 MPa to 91.0 MPa. The flexural strength of the metal-resin composite increased with the temperature of the heat treatment until 350 degrees C, but its effect varied with the concentrations of HCl of the acid treatment. A metal-resin composite, which used acid-treated and 350 degrees C heat-treated Ag-In alloy fillers, matched the requirement of strength of ISO 4049. The average of flexural modulus of the experimental metal-resin composite was 9.1 GPa. The flexural modulus of the metal-resin composite did not vary with the treatment conditions of the metal filler. The flexural modulus of a metal-resin composite, which used Ag-In alloy particle as the filler, was lower than that of Ag-Sn alloy metal-resin composite, which was reported previously. However, the flexural strength of the Ag-In alloy metal-resin composite was similar to that of Ag-Sn alloy metal-resin composite. We can control a flexural modulus of a metal-resin composite without decreasing flexural strength by choosing filler materials.

Algorithms↗

Development of bonding system for resin core construction by MomegaA adhesive.

We designed self-etching primers consisting of a series of four N-methacryloyl-omega-amino acids, MomegaA, of different methylene chain numbers for resin core construction. The interacted amount of MomegaA's carboxylic acid with root or crown dentin apatite was determined, and its effects on dentin bond durability examined. The addition of both dentin particles to the MomegaA solutions caused the carbonyl carbon peak of carboxylic acid in MomegaA to shift to a lower field, chiefly because of an acid-base interaction between carboxylic acid and calcium. Then, as the pKa value of MomegaA's carboxylic acid increased, the amount of carboxylic acid that interacted with calcium decreased. In terms of dentin bonding durability, the four tested MomegaA adhesives provided noticeably higher bond strengths of resin to root or crown dentin than ED Primer II. Therefore, from the perspective of restoring pulpless teeth with minimal intervention, carboxylated MomegaA adhesives seemed to be very useful as functional monomers for self-etching primers.

Animals↗

Mechanism and clinical implications of bond formation for two dentin bonding agents.

The mechanism of dentin bonding remains a subject of conjecture. However, sparse evidence is available to support current specific mechanisms for the various systems. Comprehension of the fundamental processes in bonding would encourage a greater appreciation for the critical procedures that ensure clinical success. An SEM study was conducted to examine the mechanism of bonding for two similar dentin bonding systems, Scotchbond 2 and Gluma. For these systems, experimental results support the formation of a mechanical bond resulting from resin infiltration and polymerization within the dentinal matrix. Effective bonding is dependent upon comprehension of the regimented procedures.

Acid Etching, Dental↗

Initiating polymerization of glycol methacrylate with cyclic diketo carbon acids.

Several pharmacologically active cyclic diketone carbon acids, including phenylbutazone and 2-phenyl-1,3-indandione, catalyze the polymerization of glycol methacrylate monomers. GMA-cyclic diketone carbon acid monomer mixtures incorporating imidazole polymerize smoothly without obvious exothermicity at temperatures ranging from ambient to -5 C without the use of ultraviolet light. The only equipment required for this embedding technique is a refrigerator with a freezing compartment which can maintain temperatures of -15 C. A recipe consisting of 5 ml glycol methacrylate (2-hydroxyethyl methacrylate), 0.8 ml 1-pentanol, 16 mg imidazole, and 30 mg monophenylbutazone is recommended for general use. The use of dicyclopentyl methacrylate-glycol methacrylate comonomer mixtures incorporating cyclic ketone catalysts is advocated, as blends of these monomers have low basophilia, and tissues embedded in these matrices stain sharply and brilliantly. It is hypothesized that the driving force for the cyclic ketone-mediated polymerization of glycol methacrylate under basic conditions is furnished by the lysis of cyclic ketone carbon acid peroxides.

Acrylates↗

Quantitative microleakage of some dentinal bonding restorative systems.

The quantitative microleakage of class V cementum (dentin) cavities restored with six dentinal bonding restorative systems was determined in vitro. Ninety extracted human permanent first and second mandibular and maxillary premolars were used in this study. Class V preparations were made in cementum (dentin) at the root facial surfaces. The preparations were restored with 1) a dentin bonding system containing 2% HEMA and BisGMA and a light-cured microfilled composite; 2) the same materials only substituting META/MMA base and TBB catalyst monomers for the BisGMA sealer; 3) a dentin bonding system containing 35% HEMA with META/MMA base and TBB catalyst, and a light-cured hybrid composite; 5) the same dentin bonding system only substituting the 35% glycerylmethacrylate for the 35% HEMA and using the microfilled composite; and 6) the previously described system with a substitution of 0.5 mol EDTA for the 10% citric acid -3% FeCl3. Fifteen teeth were restored with each procedure. The restorations were finished with 12-bladed carbide burs 15 min after placement, the teeth were stored in saline at 37 degrees C for 24 h, finished with Sof-Lex discs and then thermocycled in 2% methylene blue solution 500 times between 50 degrees C and 8 degrees C with a dwell time of 15 s. Quantitative microleakage was determined by a spectrophotometric dye-recovery method and expressed in microgram/dye/restoration. The data were analyzed by ANOVA, Student-Newman-Keuls and Kruskal-Wallis tests. The quantitative microleakage of the teeth restored with the adhesive systems containing 35% glyceryl methacrylate was significantly reduced. The bonding mechanism of glyceryl methacrylate is not known.

Analysis of Variance↗

Inhibition of serum albumin flux across exposed dentine following conditioning with GLUMA primer, glutaraldehyde or potassium oxalates.

A variety of medicaments used on dentine in various treatment procedures may cause a reduction in dentine permeability. By observing the flow of endogenous serum albumin across exposed dentine, agents known to promote dentine bonding of restorative resins or retard dentine sensitivity were assessed regarding their capacity to arrest dentinal fluid flow. Experiments were conducted in young adult macaque monkeys employing Class V cavity preparations in incisors and canines. A diffusion-in-gel-enzyme-linked-immunosorbent-assay (DIG-ELISA) was used to quantitate serum albumin in effluents from these cavities at various time periods following either no treatment or topical application with GLUMA primer, glutaraldehyde or potassium oxalates. While in untreated cavities serum albumin continued to flow even after a period of 1 week, a substantial reduction or complete cessation of serum albumin flux was seen following topical application of the agents tested, suggesting a durable effect on dentinal fluid flow. No difference between agents was observed. Further cutting of the cavity bottom a few tenths of a millimetre resulted in renewed flow of serum albumin. Data suggest that the solutions tested are capable of reducing dentinal fluid flow onto exposed dentine surfaces.

Acid Etching, Dental↗