PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Radiation, Nonionizing”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16Linked to original sources

Non-ionizing radiation safety program management--one corporation's approach.

Development and implementation of non-ionizing radiation safety programs differ from ionizing radiation safety programs primarily due to the absence of prescriptive state and federal regulations. Industry consensus standards and research publications provide the basis for non-ionizing radiation safety program development. This work discusses the methodology used to develop a non-ionizing radiation safety program suitable, with minimal modification, for use both in research and industrial facilities. This program includes identification of industry consensus standards, measurement of actual or potential exposure, establishment of engineering and administrative controls, training and orientation of the workforce, and tracking of changes. Implementation of the program involves cooperation between a small corporate staff and many individuals representing various environmental, safety and health as well as manufacturing and research disciplines located in the facilities that contain the actual radiation sources. Challenges in program implementation include the wide variation in types, numbers, and uses of non-ionizing sources in numerous facilities located throughout the United States. Additional opportunities include providing advice and support to facilities located outside of the United States.

Equipment Failure Analysis↗

Effect of a high-intensity static magnetic field on sciatic nerve regeneration in the rat.

The effect of a high-intensity static magnetic field on peripheral nerve regeneration is evaluated in rat sciatic nerve. Forty-four rats underwent sciatic nerve repair using polyethylene nerve guides. Postoperatively, the animals were exposed to a 1-tesla magnetic field for 12 hours per day for 4 weeks with appropriate controls. Our results demonstrate that a 1-tesla static magnetic field has no statistically significant effect on nerve regeneration as determined by myelinated axon counts and electrophysiologic studies. Also, the specific orientation of the sciatic nerve with respect to the magnetic field has no influence on axonal growth or nerve conduction. Periods of restraint of 12 hours per day for 4 weeks significantly inhibit weight gain but have no effect on peripheral nerve regeneration.

Animals↗

Occupational exposures and risk of female infertility.

This study examined the association between occupational chemical and radiation exposures and risk of medically diagnosed infertility in 281 women compared with 216 fertile women. After adjustment for age and exposures that occurred before case/referent ascertainment, there was an increased risk of infertility among those women exposed to volatile organic solvents (odds ratio [OR], 1.74; 95% confidence interval [CI], 1.11 to 2.71), chemical dusts (OR, 2.66; CI, 1.17 to 6.05), pesticides (OR, 3.02; CI, 1.10 to 8.29), and video display terminals (OR, 2.21, CI, 1.22, to 4.01). Among the medically diagnosed causes of infertility, the adjusted risk associated with having an ovulatory factor increased among those women exposed to solvents (OR, 1.75; CI, 1.03 to 2.98), dusts (OR, 3.00; CI, 1.19 to 7.52), or pesticides (OR, 3.82; 1.28 to 11.42). Solvents and dusts also were associated with a higher risk of tubal-factor infertility (solvents; OR, 1.95; CI, 1.08 to 3.52; dusts: OR, 2.87; CI, 1.05 to 7.88) and endometriosis (solvents: OR, 2.13; CI, 0.96 to 4.72; dusts: OR, 3.63; CI, 0.99 to 13.28). Video display terminal exposure was more likely to be found among those women diagnosed with endometriosis (OR, 3.69; CI, 1.50 to 9.13) and cervical-factor infertility (OR, 2.65; CI, 0.99 to 7.12). Results suggest that among women with a medically confirmed diagnosis, fertility may be adversely affected by a variety of occupational chemical exposures.

Adolescent↗

Highly cross-linked, electron-beam-irradiated, melted polyethylene: some pros.

Extensive new evidence generated within the past the year provides strong support for the use of electron-beam highly cross-linked, subsequently melted ultra-high molecular weight polyethylene in total hip replacement arthroplasty. In terms of wear reduction, three studies involving three different demographic groups and two different measurement techniques have found that the femoral head penetration with this type of polyethylene after bedding in has finished taking place is less than 10 micra per year. This wear rate is similar to the wear rate of metal-on-metal and ceramic-on-ceramic articulations. Retrieval specimens up to 3 years after insertion confirmed the minimal wear by exhibiting persisting machine marks throughout the inside diameter of the liner. Extensive studies show no evidence of oxidation, confirming the absence of residual free radicals. No evidence of fatigue failure exists except three known cases out of 150,000, in which malposition of the acetabular component produced abnormally high contact stresses on unsupported polyethylene. The in vivo wear, oxidation resistance, and mechanical properties of this alternative bearing material are excellent, with in vivo durations now exceeding five years. The other major advantages over hard-on-hard bearings including familiarity, adaptability, forgiveness, and cost seem to be compelling.

Adult↗

Epidemiological risk assessment of mobile phones and cancer: where can we improve?

This paper aims to provide an overview of factors affecting the validity of epidemiological studies on health effects of mobile phone use. A qualitative review of published studies is presented, covering both risk assessment and exposure assessment. Considerable random error is likely to have occurred in studies carried out so far, primarily related to exposure assessment. Self-reported use of mobile phone appears to be imprecise. The relationship between the amount of mobile phone use and the radio-frequency field is unclear. Several factors affect the strength of the radio-frequency field emitted by the phone, and accommodating their effect has the potential to improve exposure assessment. The major opportunity to improve the quality of evidence is, however, through prospective studies. The major limitation of epidemiological studies addressing the health effects of mobile phone use is related to exposure assessment. These limitations are inherent in case-control studies. Quality of evidence can be improved by conducting prospective cohort studies.

Case-Control Studies↗

An analysis of differences in the low-frequency electric and magnetic field exposure standards of ices and ICNIRP.

Technical factors accounting for differences in low-frequency (0-3 kHz) standards of IEEE C95.6 and ICNIRP are identified. These factors are related to thresholds of adverse reactions, safety factors, probability factors, thresholds for different tissue types, magnetic induction models, and induced current and spark discharges with E-field exposure. This paper summarizes technical factors accounting for differences between the two standards and recommends resolution of those factors.

Electromagnetic Fields↗

Resolution of radio frequency exposure concerns at Woods Hole Oceanographic Institution with a collaborative approach.

Numerous employees at the Woods Hole Oceanographic Institution (WHOI) have expressed health concerns about occupational exposures to various radio frequency radiation (RFR) sources. These RFR sources of concern include primarily radar systems (ship and experimental) and various communication systems (ship, roof top transmitting and receiving antennas, and portable transceivers). A certified testing service and an independent health physics consultant evaluated the RFR exposures using appropriate methods and concluded that all occupied work areas were below the applicable maximum permissible exposure (MPE) limits. Despite these independent conclusions, numerous employees continued to express health concerns and an interest in evaluating their exposures with a monitoring device that was more representative of their personal exposure (i.e., could be worn on body). To facilitate resolution of these concerns, a collaborative approach between the Environmental, Health & Safety Office and the concerned employees was developed that included: 1) a literature search was conducted and information on RFR health effects, exposure limits, and assessment methods was compiled and made available to all concerned employees; 2) all RFR sources of concern were identified and characterized by frequency; 3) an RFR personal monitor was evaluated and selected; 4) RFR exposures were evaluated with full-shift monitoring; and 5) data logged monitoring results and the relevant exposure limits were evaluated. All monitored exposures have been less than 10% of the MPE limit from the Institute of Electrical and Electronics Engineers (IEEE) Standard C95.1-1999 for controlled areas, and all occupational RFR exposure concerns have been resolved.

Humans↗

Needle biopsy of anatomically unfavorable liver lesions with an electromagnetic navigation assist device in a computed tomography environment.

PURPOSE: Emerging interventional radiology assistance systems that incorporate electromagnetic navigation (EMN) can help the operator guide a needle or other instrument toward a target along preplanned oblique trajectories while avoiding critical structures. A proof-of-concept study was conducted to assess the use of EMN, and EMN was compared with the standard computed tomographic (CT) fluoroscopy guidance technique. MATERIALS AND METHODS: A total of 14 needle passes, seven each with EMN and CT fluoroscopy guidance, were performed into an artificially created liver lesion of a single swine. The accuracy of needle placement for each pass was verified with a confirmatory CT scan. The total radiation dose and time of procedure was compared between the EMN and conventional CT fluoroscopy methods. RESULTS: All needle passes were successful, and all passes conducted with EMN were completed with a single insertion, whereas multiple passes (mean, 2.9) with needle repositioning were required with CT fluoroscopic guidance. Statistically significant reduction in procedure time and overall radiation dose for EMN punctures was shown. Accuracy of needle placement was statistically equivalent for the two methods. CONCLUSIONS: This proof-of-concept study shows that EMN guidance has equivalent accuracy of needle placement to conventional CT fluoroscopy-guided methods in swine. EMN is also associated with favorable radiation-dose and time-of-procedure profiles for biopsy of liver lesions. Clinical studies are needed to evaluate the safety and efficacy of this technology in the biopsy of lesions in anatomically challenging locations that require steep angles of needle insertion.

Animals↗

Electromagnetic fields and human endocrine system.

Extremely low frequency electromagnetic fields (ELF EMF) are commonly present in daily life all over the world. Moreover, EMF are used in the physiotherapy of many diseases because of their beneficial effects. There is widespread public concern that EMF may have potential consequences for human health. Although experimental animal studies indicate that EMF may influence secretion of some hormones, the data on the effects of EMF on human endocrine system are scarce. Most of the results concentrate on influence of EMF on secretion of melatonin. In this review, the data on the influence of EMF on human endocrine system are briefly presented and discussed.

Animals↗

Effects of 2.45-GHz electromagnetic fields with a wide range of SARs on micronucleus formation in CHO-K1 cells.

There has been considerable discussion about the influence of high-frequency electromagnetic fields (HFEMF) on the human body. In particular, HFEMF used for mobile phones may be of great concern for human health. In order to investigate the properties of HFEMF, we have examined the effects of 2.45-GHz EMF on micronucleus (MN) formation in Chinese hamster ovary (CHO)-K1 cells. MN formation is induced by chromosomal breakage or inhibition of spindles during cell division and leads to cell damage. We also examined the influence of heat on MN formation, since HFEMF exposure causes a rise in temperature. CHO-K1 cells were exposed to HFEMF for 2 h at average specific absorption rates (SARs) of 5, 10, 20, 50, 100, and 200 W/kg, and the effects on these cells were compared with those in sham-exposed control cells. The cells were also treated with bleomycin alone as a positive control or with combined treatment of HFEMF exposure and bleomycin. Heat treatment was performed at temperatures of 37, 38, 39, 40, 41, and 42 degrees C. The MN frequency in cells exposed to HFEMF at a SAR of lower than 50 W/kg did not differ from the sham-exposed controls, while those at SARs of 100 and 200 W/kg were significantly higher when compared with the sham-exposed controls. There was no apparent combined effect of HFEMF exposure and bleomycin treatment. On heat treatment at temperatures from 38-42 degrees C, the MN frequency increased in a temperature-dependent manner. We also showed that an increase in SAR causes a rise in temperature and this may be connected to the increase in MN formation generated by exposure to HFEMF.

Animals↗

Influence of 50-Hz electromagnetic field on anurian (Xenopus laevis) metamorphosis.

In this study, we show the effect of a 1-mT magnetic field AC at 50 Hz on Xenopus laevis tadpole populations. In the course of a 65-day exposure to the field, tadpole survival showed a small, but significant, decrease (p < 0.0004), together with a striking parallel 6-day shift in tadpole maturation frequency and a significant impairment of their metamorphosis. Particularly, metamorphosis was successful for 85% of individuals in the unirradiated tadpole population and for 45% of individuals in the irradiated tadpole population, respectively.

Animals↗

The biological effect of extremely low frequency electromagnetic fields and vibrations on barley seed hydration and germination.

The changes of wet and dry weights and germination of barley seed in different periods of its swelling in nontreated (control), extremely low frequency electromagnetic fields (ELF EMF) )-treated, and extremely low frequency vibrations (ELFV)-treated cold (4 degrees C) and warm (20 degrees C) distilled water (DW) were studied. The metabolic-dependent seed hydration, dry weight dissolving, germination, and water binding in seed were modulated by preliminary EMF- and ELFV-treated DW. Frequency "windows" for the effect of EMF and ELFV on seed hydration, solubility, water binding in seed, and germination were discovered. These "windows" were different for EMF and ELFV, as well as in various phases of seed swelling. It is suggested that EMF-induced water structure modification has a different biological effect on the process of seed hydration, solubility, water binding in seed, and germination compared to ELFV.

Electromagnetic Fields↗

The effects of 910-MHz electromagnetic field on rat cranial arachnoid and dura mater collagen. The axial periodicity of collagen fibrils.

The axial periodicity of rat arachnoid and dura mater collagen fibrils exposed to 910 MHz for 2 h/day for 30 consecutive days was measured by means of image analysis of electron-optical data. Such measurements were compared with those from sham-exposed animals. These measurements reveal that on exposure, the intermolecular interactions during collagen fibril assembly are affected.

Animals↗

Alteration of tight and adherens junctions on 50-Hz magnetic field exposure in Madin Darby canine kidney (MDCK) cells.

Adherens (AJ) and tight junctions (TJ), as integrated parts of the junctional complex, are multifunctional specialized regions of the cell membrane in epithelial cells. They are responsible for cell-to-cell interactions and also have great importance in cellular signaling processes including Wnt protein-mediated signals. As electromagnetic field (EMF) exposure is known to cause alterations in the function as well as supramolecular organization of different cell contacts, our goal was to investigate the effect of 50-Hz magnetic field (MF) exposures on the subcellular distribution of some representative structural proteins (occludin, beta-catenin, and cadherin) found in AJ and TJ. Additionally, cellular beta-catenin content was also quantified by Western blot analysis. 50-Hz MF exposures seemed to increase the staining intensity (amount) of occludin, cadherins, and beta-catenin in the junctional area of MDCK cells, while Western blot data indicated the quantity of beta-catenin was found significantly decreased at both time points after EM exposures. Our results demonstrate that MF are able to modify the distribution of TJ and AJ structural proteins, tending to stabilize these cell contacts. The quantitative changes of beta-catenin suggest a causative relationship between MF effects on the cell junctional complex and the Wnt signaling pathway.

Adherens Junctions↗

Effects of whole-body 50-Hz magnetic field exposure on mouse Leydig cells.

The main goal of this study was to evaluate the possible effect of whole-body magnetic field (MF) exposure on the steroidogenic capacity of Leydig cells in vitro. In four separate experiments, male CFLP mice were exposed to sinusoidal 50-Hz, 100-microT MF. The duration of exposure was 23.5 h/day over a period of 14 days. At the end of the exposure, interstitial (Leydig) cells were isolated from the testicles of the sham-exposed and exposed animals. The cells were cultured for 48 h in the presence or absence of 1, 10, or 100 mIU/ml human chorionic gonadotropin (hCG). The luteinizing hormone (LH) analog hCG was used to check the testosterone (T) response of the sham-exposed controls and to evaluate the possible effect of the whole-body MF exposure on the steroidogenic capacity of Leydig cells in vitro. Testosterone content of the culture media and blood sera was measured by radioimmunoassay (RIA). In the cultures obtained from MF-exposed animals, the hCG-stimulated T response was significantly higher (p < 0.01) compared with the sham-exposed controls, while the basal T production of cells and the level of serum T remained unaltered. No MF exposure-related histopathological alterations were found in testicles, epididymes, adrenals, prostates, and pituitary glands. The MF exposure did not affect the animal growth rate and the observed hematologic and serum chemical variables. Our results indicate a presumably direct effect of whole-body MF exposure on the hCG-stimulated steroidogenic response of mouse Leydig cells.

Adrenal Glands↗

The effect on rat thymocytes of the simultaneous in vivo exposure to 50-Hz electric and magnetic field and to continuous light.

Thymus plays an important role in the immune system and can be modulated by numerous environmental factors, including electromagnetic fields (EMF). The present study has been undertaken with the aim to investigate the role of long-term exposure to extremely low frequency electric and magnetic fields (ELF-EMF) on thymocytes of rats housed in a regular dark/light cycle or under continuous light. Male Sprague-Dawley rats, 2 months old, were exposed or sham exposed for 8 months to 50-Hz sinusoidal EMF at two levels of field strength (1 kV/m, 5 microT and 5 kV/m, 100 microT, respectively). Thymus from adult animals exhibits signs of gradual atrophy mainly due to collagen deposition and fat substitution. This physiological involution may be accelerated by continuous light exposure that induces a massive death of thymocytes. The concurrent exposure to continuous light and to ELF-EMF did not change significantly the rate of mitoses compared to sham-exposed rats, whereas the amount of cell death was significantly increased, also in comparison with animals exposed to EMF in a 12-h dark-light cycle. In conclusion, long-term exposure to ELF-EMF, in animals housed under continuous light, may reinforce the alterations due to a photic stress, suggesting that, in vivo, stress and ELF-EMF exposure can act in synergy determining a more rapid involution of the thymus and might be responsible for an increased susceptibility to the potentially hazardous effects of ELF-EMF.

Animals↗