PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Solid Phase Microextraction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16Linked to original sources

Air sampling with porous solid-phase microextraction fibers

A new, rapid air sampling/sample preparation methodology was investigated using adsorptive solid-phase microextraction (SPME) fiber coatings and nonequilibrium conditions for volatile organic compounds (VOCs). This method is the fastest extraction technique for air sampling at typical airborne VOC concentrations. A theoretical model for the extraction was formulated based on the diffusion through the interface between the sampled (bulk) air and the SPME coating. Parameters that affect the extraction process including sampling time, air velocity, air temperature, and relative humidity were investigated with the porous (solid) PDMS/DVB and Carboxen/PDMS coatings. Very short sampling times from 5 s to 1 min were used to minimize the effects of competitive adsorption and to calibrate the extraction process in the initial linear extraction region. The predicted amounts of extracted mass compared well with the measured amounts of target VOCs. Findings presented in this study extend the existing fundamental knowledge related to sampling/sample preparation with SPME, thereby enabling the development of new sampling devices for the rapid sampling of air, headspace, water, and soil.

Journal Article↗

The leaf volatile constituents of Isatis tinctoria by Solid-Phase Microextraction and Gas chromatography/Mass Spectrometry.

The leaf volatile constituents of Isatis tinctoria L. (Brassicaceae) have been studied by Solid-Phase Microextraction and Gas chromatography/Mass Spectrometry (SPME/GC-MS). Seventy components were fully characterized by mass spectra, linear retention indices, and injection of standards; the average composition (ppm) as single components and classes of substances is reported. Aliphatic hydrocarbons, acids, alcohols, aldehydes and esters, aromatic aldehydes, esters and ethers, furans, isothiocyanates and thiocyanates, sulfurated compounds, nitriles, terpenes and sesquiterpenes were identified. Leaf volatiles in Isatis tinctoria L. were characterized by a high amount of isothiocyanates which accounted for about 40 % of the total volatile fraction. Isothiocyanates are important and characteristic flavour compounds in Brassica vegetables and the cancer chemo-protective attributes are recently responsible for their growing interest.

Gas Chromatography-Mass Spectrometry↗

Improved solid-phase microextraction device for use in on-line immunoaffinity capillary electrophoresis.

A simple solid-phase microextraction device was fabricated for use in on-line immunoaffinity capillary electrophoresis (CE). The device, designed in the form of a four-part cross-shaped or cruciform configuration, includes a large-bore tube to transport samples and washing buffers and a small-bore fused-silica capillary for separation of analytes. At the intersection of the transport and separation tubes, a small cavity was fabricated, termed the analyte concentrator-microreactor, which contains four porous walls or semipermeable membranes (one for each inlet and outlet of the tubes) permitting the confinement of beads or suitable microstructures. The surface of the beads in the analyte concentrator carried a molecular recognition adsorbing chemical or affinity ligand material. The improved cruciform configuration of the analyte concentrator-microreactor device, designed for use in on-line immunoaffinity CE, enables it to specifically trap, enrich, and elute an analyte from any biological fluid or tissue sample extract without any sample pretreatment except filtration, centrifugation, and/or dilution allowing the separation and characterization of target analyte(s) with improved speed, sensitivity, and lower cost than existing techniques. As a model system, Fab' fragments derived from a purified immunoglobulin G (IgG) antibody were covalently bound to controlled-porosity glass and used as constituents of the analyte-microreactor device. The high-specificity polyclonal antibodies employed in these experiments were individually raised against the acidic nonsteroidal anti-inflammatory drugs ibuprofen and naproxen, and the neuropeptides angiotensin II, and neurotensin. These compounds, which were present in simple and complex matrices were captured by and eluted from the analyte concentrator-microreactor using a 50 mM sodium tetraborate buffer solution, pH 9.0, followed by a 100 nL plug of 300 mM glycine buffer, pH 3.4. Two analyte concentrators were tested independently: one containing Fab' fragments derived from antibodies raised against ibuprofen and naproxen; the other containing Fab' fragments derived from antibodies raised against angiotensin II and neurotensin. Each resulting electropherogram demonstrated the presence of two eluted materials in less than 20 min. Immunoaffinity CE performed in a cruciform structure was simpler and faster than previously reported in the literature using on-line microextraction devices designed in a linear format. The new concentration-separation system operated consistently for many runs, maintaining reproducible migration times and peak areas for every analyte studied.

Amino Acid Sequence↗

Identification and quantification of methyl jasmonate in leaf volatiles of Arabidopsis thaliana using solid-phase microextraction in combination with gas chromatography and mass spectrometry.

Static headspace sampling with solid-phase microextraction has been used in combination with GC-FID and GC-MS for the specific enrichment, identification and quantification of volatile methyl jasmonate secreted by wounded leaves of Arabidopsis thaliana. The microsample method of analysis was found to be precise, accurate, sensitive and rapid. The detection limit of the procedure is 1.5 ppb (approximately 1.3 ng) per injection, which is of adequate sensitivity to detect the natural baseline levels of methyl jasmonate (approximately 10-100 ng/g) present in plant tissues. The method can be applied to most plants, requires a minimum of sample material, and shows the additional advantage that it is suitable for automation and could thus be used for high-throughput screening.

Acetates↗

Determination of camptothecin and 10-hydroxycamptothecin in human plasma using polymer monolithic in-tube solid phase microextraction combined with high-performance liquid chromatography.

A biocompatible in-tube solid-phase microextraction (SPME) device was used for the direct and on-line extraction of camptothecin and 10-hydroxycamptothecin in human plasma. Biocompatibility was achieved through the use of a poly(methacrylic acid-ethylene glycol dimethacrylate) monolithic capillary column for extraction. Coupled to high performance liquid chromatography (HPLC) with UV detection, this on-line in-tube SPME method was successfully applied to the simultaneous determination of camptothecin and 10-hydroxycamptothecin in human plasma. The calculated detection limits for camptothecin and 10-hydroxycamptothecin were found to be 2.62 and 1.79 ng/mL, respectively. The method was linear over the range of 10-1000 ng/mL. Excellent method reproducibility was achieved, yielding RSDs of 2.49 and 1.59%, respectively. The detection limit (S/N = 3) of camptothecin was found to reach 0.1 ng/mL using fluorescence detection. The proposed method was shown to cope robustly with the extraction and analysis of camptothecin and 10-hydroxycamptothecin in plasma samples.

Camptothecin↗

Method for analysis of 4-hydroxy-2-(E)-nonenal with solid-phase microextraction.

A simple analytical method for 4-hydroxy-2-(E)-nonenal (HNE) using solid-phase microextraction (SPME) fiber was developed. HNE or the derivative of HNE formed by reaction with 2,4-dinitrophenylhydrazine (DNPH) was extracted from the sample solution by immersing the SPME fiber into the solution, and the amount of HNE was quantified by HPLC. The extraction conditions of HNE and HNE-DNPH were examined, using standard solutions, with respect to fiber coating, NaCl concentration, rate of stirring, adsorption temperature, and adsorption time. The recovery of HNE reached 80%, and the quantification limits of HNE and HNE-DNPH using standard compounds were 14.1 pmol/10 mL and 486.5 fmol/10 mL, respectively. This method can be applied to the detection of HNE in oxidized oil or samples of porcine liver.

Aldehydes↗

Application of solid-phase microextraction to the headspace gas chromatographic analysis of halogenated volatiles in selected foods.

Solid-phase microextraction (SPME), with the poly(dimethylsiloxane)-coated silica fiber suspended and equilibrated in the headspace, has been applied to the capillary gas chromatographic (GC) analysis of 33 halogenated volatile contaminants in model aqueous solutions and in foods. With electrolytic conductivity detection, the limits of detection in water ranged from 1.5 micrograms/kg for vinyl chloride to < or = 0.005 microgram/kg for the tri- to hexachlorobenzenes. Headspace SPME-GC shows a much greater response for the less volatile analytes than those of greater volatility, a procedure complementing headspace GC with gas sampling. In model systems or foods, increasing lipid material decreased the headspace extraction. With 50 mg of lipid, the headspace extraction decreased about 50% for analytes with LODs about 0.1 microgram/kg and by > or = 99.5% for the above chlorobenzenes. Standard addition was used to analyze a variety of beverages and dry foods and to determine the analyte partitions.

Beverages↗

Development of a solid-phase microextraction method for the analysis of phenolic flame retardants in water samples.

A solid-phase microextraction (SPME) method for the ultra-trace determination of brominated phenols in aqueous samples has been developed and is reported for the first time to the best of our knowledge. 3,5,3',5'-tetrabromobisphenol A (TBBPA), the most widely used brominated flame retardant, and other phenolic flame retardants in commercial use, such as 2,4-dibromophenol (2,4-DBP), 2,4,6-tribromophenol (TBP) and pentabromophenol (PBP) have been included as target analytes. The analytical procedure involves the in situ acetylation-SPME and gas chromatography-mass spectrometry (GC-MS) determination of the target analytes. A multi-factor categorical experimental design was created to study the main parameters affecting the extraction efficiency, allowing also the evaluation of interaction effects between factors. The factors studied were type of fiber, extraction mode, exposing the fiber directly into the sample (DSPME) or into the headspace over the sample (HSSPME), and extraction temperature. Carboxen-polydimethylsiloxane (CAR-PDMS) fiber appeared to be the most suitable of the five fibers tested for the extraction of most compounds, excluding PBP and TBBPA for which polydimethylsiloxane (PDMS) was the most efficient coating. The highest response was achieved for both fibers sampling in headspace mode at 100 degrees C. In order to test the linearity of the method, calibration studies were performed with both CAR-PDMS and PDMS coatings. For both fibers, the method was linear in a range of 2 orders of magnitude, giving relative standard deviation (RSD%) below 10% for most compounds and detection limits at the low pg/mL level. In addition, the feasibility of the method for simultaneous determination of chlorinated and brominated phenols was studied. Finally, the method was applied to several real samples including tap water and effluent and influent waste water samples from an urban treatment plant, in which several phenolic compounds, such as phenol, methylphenols and chlorophenols, could be detected and quantified.

Acetylation↗

Study of preservation of polydimethylsiloxane/Carboxen solid-phase microextraction fibres before and after sampling of volatile organic compounds in indoor air.

Solid-phase microextraction (SPME) was applied to the on-site analysis of volatile organic compounds (VOCs) in indoor air. The compounds were at trace levels, which complicates analysis and also sample storage. Fibre storage before and after sampling was studied. Several tests were performed, and the best results were obtained for a home-made storage assembly. To avoid contamination by acetone and acetaldehyde, activated carbon was added in the storage housing. Under these conditions, fibres can be stored up to 2 days before use. After sampling, storage of 10 VOCs was evaluated by varying air relative humidity of the air. This parameter was shown to be insignificant for 3 storage days: recoveries for acetaldehyde and acetone were 149 and 176%, respectively, and ranged from 95 to 107% for the other VOCs investigated.

Air Pollutants↗

Determination of Brett character responsible compounds in wines by using multiple headspace solid-phase microextraction.

This study presents a method based on the use of multiple headspace solid-phase microextraction (MHS-SPME) for the quantitative analysis of 4-ethylphenol, 4-ethylguaiacol, 4-vinylphenol and 4-vinylguaiacol. MHS-SPME is a modification of SPME that implies several consecutive extractions from the same sample and avoids possible matrix effects. This study demonstrates the existence of a matrix effect in the analysis of compounds responsible for Brett character in wine when an HS-SPME based method is used with a carbowax/divinylbenzene (CW/DVB) fibre. For this reason, MHS-SPME is proposed as an alternative technique with respect to HS-SPME. The method proposed was validated and the detection limits obtained were 0.06 microg/l for 4-ethylguaiacol and 4-ethylphenol and, 0.20 microg/l for 4-vinylguaiacol and 0.12 microg/l for 4-vinylphenol. These detection limits are below the odour detection thresholds of the compounds in wine matrices. The repeatability obtained, in terms of relative standard deviation (RSD), was considered acceptable, ranging from 1 to 12%. To evaluate the applicability of the proposed MHS-SPME method, concentration results were compared with those obtained with the standard addition method, and the results were similar with both methods. Furthermore, the new method was satisfactorily applied to a number of commercial red, white and rosé wines. Therefore, MHS-SPME can be considered as an alternative to avoid the matrix effect in wine samples.

Calibration↗

Solid-phase microextraction and chiral HPLC analysis of ibuprofen in urine.

A simple and rapid solid-phase microextraction method was developed for the enantioselective analysis of ibuprofen in urine. The sampling was made with a polydimethylsiloxane-divinylbenzene coated fiber immersed in the liquid sample. After desorptioning from the fiber, ibuprofen enantiomers were analyzed by HPLC using a Chiralpak AD-RH column and UV detection. The mobile phase was made of methanol-pH 3.0 phosphoric acid solution (75:25, v/v), at a flow rate of 0.45 mL/min. The mean recoveries of SPME were 19.8 and 19.1% for (-)-R-ibuprofen and (+)-(S)-ibuprofen, respectively. The method was linear at the range of 0.25-25 microg/mL. Within-day and between-day assay precision and accuracy were below 15% for both ibuprofen enantiomers at concentrations of 0.75, 7.5 and 20 microg/mL. The method was tested with urine quality control samples and human urine fractions after administration of 200 mg rac-ibuprofen.

Chromatography, High Pressure Liquid↗

Improving gas chromatographic determination of residual solvents in pharmaceuticals by the combined use of headspace solid-phase microextraction and isotopic dilution.

Cyclohexane and toluene were gas chromatographically determined via headspace solid-phase microextraction both in ketoprofen drug substance and ketoprofen capsules by a procedure relying on isotopic dilution (ID), an analytical tool derived from mass spectrometry (MS). This approach, using an internal standard method, gave mean precision and accuracy (RSD 2.56%, 2.97% and bias 0.21%, -0.99% for cyclohexane and toluene, respectively) not obtainable by the more commonly used external standard ones in the presence of real sample matrices. Optimisation of the operative conditions was also supported by experimental design. More generally, the proposed method, exploiting ID without resort to the costly MS instrumentation, could be recommended whenever opportune deuterated analogues of the target analytes and GC capillary columns able to separate all the peaks involved are ready available on the market.

Calibration↗

Solid-phase microextraction coupled to liquid chromatography for the analysis of phenolic compounds in water.

Solid-phase microextraction (SPME) coupled to high-performance liquid chromatography (HPLC) has been applied to the analysis of priority pollutant phenolic compounds in water samples. Two types of polar fibers [50 microm Carbowax-templated resin (CW-TPR) and 60 microm polydimethylsiloxane-divinylbenzene (PDMS-DVB)] were evaluated. The effects of equilibration time and ionic strength of samples on the adsorption step were studied. The parameters affecting the desorption process, such as desorption mode, solvent composition and desorption time, were optimized. The developed method was used to determine the phenols in spiked river water samples collected in the Douro River, Portugal. Detection limits of 1-10 microg l(-1) were achieved under the optimized conditions.

Chromatography, High Pressure Liquid↗

Solid-phase microextraction of monocyclic aromatic amines using novel fibers coated with crown ether.

Three solid-phase microextraction (SPME) fibers prepared by the sol-gel method, containing hydroxydibenzo-14-crown-4 (OH-DB14C4), dihydroxy-substituted saturated urushiol crown ether (DHSU14C4) and 3,5-dibutyl-unsymmetry-dibenzo-14-crown-4-dihydroxy crown ether (DBUD14C4), respectively, were evaluated for the determination of aromatic amine (aniline, m-toluidine, N,N-diethylaniline, N-ethyl-m-toluidine, 3,4-dimethylaniline). The sol-gel-derived hydroxy-dibenzo14-crown-4-coated fiber has the best affinity for several aniline derivatives. Optimization was carried out for the determination of aromatic amines with SPME fibers. The linearity was from 0.11 to 29 microg/ml and detection limits varied from 0.17 to 0.98 ng/ml. Relative standard deviation (n=5) was found to be 3.23-6.20%. The coating proved to be very stable at high temperature (to 340 degrees C) and in different solvents (organic and inorganic). The method was applied to the determination of aromatic amines in wastewater samples from a pharmaceutical factory.

Amines↗

Application of headspace solid-phase microextraction to the determination of sulphur compounds with low volatility in wines.

Headspace solid-phase microextraction (HS-SPME) has been used for determining sulphur compounds with low volatility in wines. With this technique, handling of samples is minimal so undesirable loses and reactions between compounds are prevented. Furthermore, this kind of extraction is fast and does not require any organic solvent. Under optimal conditions, the HS-SPME, using a new fibre coated with Stable Flex divinylbenzene-Carboxen-polydimethylsiloxane, makes possible the quantification of sixteen sulphur compounds with low volatility which may be present in wines. The limits of detection for the analytes studied ranged between 0.05 and 10 microg/l, and the recovery and repeatability found were acceptable. The method developed was successfully applied to determine the concentration of the target analytes in varietal wines from the Catalonian region (Spain) with some aromatic defects such as an odour of rubber, onion, rotten, unpleasant herbaceous, etc. The results show that the contents of the sulphur compounds studied in these wines are higher than in those without defects. This shows a relationship exists between the presence of sulphur compounds and the quality of the wine aroma.

Chromatography, Gas↗

Fiber introduction mass spectrometry: fully direct coupling of solid-phase microextraction with mass spectrometry.

This work describes the first fully direct coupling of solid-phase microextraction (SPME) with mass spectrometry. An inlet system using a septum as the only interface between the ambient and the high-vacuum mass spectrometer was constructed to allow the introduction of the SPME needle directly into the ionization region of a mass spectrometer. The PDMS-coated fiber was then placed and exposed exactly between the two ionization filaments. Uniform heating of the fiber, efficient thermal desorption, and electron ionization of the analytes were achieved. Using this new analytical technique, here termed fiber introduction mass spectrometry (FIMS), we have been able to detect and quantitate several volatile (VOC) and semivolatile (SVOC) organic chemicals (carbon tetrachloride, benzene, toluene, xylenes, gamma-terpinene, diisoamyl ether, chlorobenzene, and many PAHs) and two herbicides (Sylvex and its methyl ether) from aqueous solutions at low-ppb to ppt levels using either SPME headspace or solution extraction. FIMS shows high sensitivity (ng/L), good reproducibility, and accuracy, providing therefore a simple and effective approach to rapid analysis of VOC and SVOC in various matrixes.

Chemistry Techniques, Analytical↗

Solid phase microextraction with matrix assisted laser desorption/ionization introduction to mass spectrometry and ion mobility spectrometry.

Solid phase microextraction (SPME) with matrix assisted laser desorption/ionization (MALDI) introduction was coupled to mass spectrometry and ion mobility spectrometry. Nicotine and myoglobin in matrix 2,5-dihydroxybenzonic acid (DHB), enkephalin and substance P in alpha-cyano-4-hydroxy cinnaminic acid were investigated as the target compounds. The tip of an optical fiber was silanized for extraction of the analytes of interest from solution. The optical fiber thus served as the sample extraction surface, the support for the sample plus matrix, and the optical pipe to transfer the laser energy from the laser to the sample. The MALDI worked under atmospheric pressure, and both an ion mobility spectrometer and a quadrupole/time-of-flight mass spectrometer were used for the detection of the SPME/MALDI signal. The spectra obtained demonstrate the feasibility of the SPME with MALDI introduction to mass spectrometry instrumentation.

Enkephalins↗

Dynamic air sampling of volatile organic compounds using solid phase microextraction.

A new dynamic air sampling system was devised and evaluated in conjunction with solid phase microextraction (SPME) fiber materials for extracting odor-causing volatile organic compounds (VOCs) present in swine building environments. Utilizing a standard solution consisting of 11 compounds (i.e., volatile fatty acids, indoles, and phenol), sampling times, volumes, and flow rates were adjusted to establish optimal extraction conditions. Results indicated that the sampling system was effective with the Carboxen/Polydimethylsiloxane (CAR/PDMS) fiber in extracting all 11 standard compounds. The best sampling conditions for the extraction were a 100-mL sampling vial subjected to a continuous flow of 100 mL/min for 60 min. The gas chromatographic analysis showed that the reproducibility was within acceptable ranges for all compounds (RSD=4.24-17.26% by peak areas). In addition, field tests revealed that the sampling system was capable of detecting over 60 VOCs in a swine house whose major components were identified by gas chromatography-mass spectrometry (GC-MS) and by their retention times as volatile fatty acids, phenols, indole, and skatole. The field tests also showed that considerably different levels of VOCs were present in various parts of the swine building.

Air Pollutants↗