Present and future of surface plasmon resonance biosensors.

Surface plasmon resonance (SPR) biosensors are optical sensors exploiting special electromagnetic waves-surface plasmon-polaritons-to probe interactions between an analyte in solution and a biomolecular recognition element immobilized on the SPR sensor surface. Major application areas include detection of biological analytes and analysis of biomolecular interactions where SPR biosensors provide benefits of label-free real-time analytical technology. This paper reviews fundamentals of SPR affinity biosensors and discusses recent advances in development and applications of SPR biosensors.

Biosensing Techniques↗

An integrated electrochemical fructose biosensor based on tetrathiafulvalene-modified self-assembled monolayers on gold electrodes.

An integrated amperometric fructose biosensor based on a gold electrode (AuE) modified with a self-assembled monolayer (SAM) of 3-mercaptopropionic acid (MPA) on which fructose dehydrogenase (FDH) and the mediator tetrathiafulvalene (TTF) are co-immobilized by cross-linking with glutaraldehyde is reported. Variables concerning the behavior of the biosensor were optimized by taking the slope value obtained for the fructose calibration plot in the 0.1-1.0 mM concentration range as a criterion of selection. At an applied potential of +0.20 V, a good repeatability of such slope values (RSD=6.7%, n=10) was obtained with no need to apply a cleaning or pretreatment procedure to the modified electrode. Moreover, results from five different TTF-FDH-MPA-AuEs yielded a RSD of 5.8%. The useful lifetime of one single biosensor was approximately 30 days, exhibiting a 93% of the original response on the 33rd day. A linear calibration graph was obtained for fructose over the 1.0 x 10(-5)-1.0 x 10(-3) M range, with a limit of detection of 2.4 x 10(-6) M. The effect of potential interferents was evaluated. The TTF-FDH-MPA-AuE also performed well in the flow-injection mode. The biosensor was used for the determination of fructose in real samples, and the results compared with those provided by using a commercial enzyme test kit.

3-Mercaptopropionic Acid↗

Glucose biosensor based on glucose oxidase immobilized in sol-gel chitosan/silica hybrid composite film on Prussian blue modified glass carbon electrode.

An improved amperometric glucose biosensor based on glucose oxidase immobilized in sol-gel chitosan/silica hybrid composite film, which was prepared from chitosan (CS) and methyltrimethoxysilane (MTOS), on the surface of Prussian blue (PB)-modified glass carbon electrode was developed. The film was characterized by FT-IR. Effects of some experimental variables such as ratio of CS to silica, buffer pH, temperature, and applied potential on the current response of the biosensor were investigated. The biosensor fabricated under optimal conditions had a linear response to glucose over the range 5.0 x 10(-5) to 2.6 x 10(-2) M with a correlation coefficient of 0.9948 and a detection limit of 8.0 x 10(-6) M based on S/N = 3. The biosensor had a fast response time of less than 10 s, a high sensitivity of 420 nA mM(-1), a long-term stability of over 60 days, and a good selectivity. The apparent Michaelis-Menten constant K(m) was found to be 3.2 x 10(-3) M. The activation energy for enzymatic reaction was calculated to be 21.9 kJ mol(-1). This method has been used to determine the glucose concentration in real human blood samples.

Biosensing Techniques↗

TIRF-based biosensor for sensitive detection of progesterone in milk based on ultra-sensitive progesterone detection in water.

We report on recent advances of our immunoassay for the hormone progesterone in cow's milk. Detection is based on total internal reflectance fluorescence (TIRF), the binding-inhibition assay with an immobilized progesterone derivative, and a commercially available monoclonal antibody to progesterone as biological recognition element. The fully automated River Analyzer (RIANA) biosensor for unattended, cost-effective, and continuous monitoring of environmental pollution therefore was adapted for sensitive determination of progesterone in milk. First, the sensitivity and robustness of the existing progesterone assay for water analysis were improved, resulting in a detection limit (LOD) of only 0.2 pg mL(-1) and a quantification limit (LOQ) of only 2.0 pg mL(-1). These extraordinary results are the lowest detection and quantification limits for progesterone determination using biosensors yet reported in the literature. Second, the accurate indicator of ovulation was calibrated and detected in three different types of milk (UHT milk, fresh milk, and raw milk). For commercial milk and randomly procured raw milk nominal levels of progesterone are typically in the range 5-15 ng mL(-1). Limits of detection (LOD) achieved for added progesterone (i.e. spiked samples) were between 45.5 and 56.1 pg mL(-1) depending on milk type. Having in mind the 1:10 dilution factor, these results are still a success. For the first time a commercially available antibody was incorporated into an immunoassay for progesterone detection in bovine milk, giving a detection limit below 1 ng mL(-1) for a fully automated biosensor. Thus the outstanding progress made with this biosensor in environmental monitoring and water analysis has now been successfully adapted to milk analysis for use in the field of reproduction management.

Animals↗

Surface plasmon resonance biosensor based on Hg/Ag-Au film.

Mercury or silver was electrodeposited on an Au surface to form an Hg-Au or Ag-Au film. Wavelength-modulation SPR biosensors based on this Hg/Ag-Au film were then used to determine human IgG and rabbit IgG. When direct immunoreactions were performed on the Au sensing surface, the range of concentrations of human IgG and rabbit IgG that could be determined were 2.00-40.00 microg/ml and 2.50-40.00 microg/ml, respectively. When Hg was electrodeposited onto the Au film for 1200 s, the range of concentrations of human IgG and rabbit IgG that could be determined were 0.50-40.00 microg/ml and 0.63-40.00 microg/ml, respectively. When Ag was electrodeposited onto the Au film for 1500 s, the range of concentrations of human IgG and rabbit IgG that could be determined were 0.25-20.00 and 0.42-20.00 microg/ml, respectively. The biosensor based on Ag-Au film was therefore found to be the most sensitive of the three types of biosensor tested, giving limits of determination that were up to eight times lower than those obtained with a biosensor based on Au film alone.

Biosensing Techniques↗

A stable glucose biosensor prepared by co-immobilizing glucose oxidase into poly(p-chlorophenol) at a platinum electrode.

An amperometric glucose biosensor was successfully developed by electrochemical polymerization of p-chlorophenol (4-CP) at a Pt electrode in the presence of glucose oxidase. The amperometric response of this biosensor to hydrogen peroxide, formed as the product of enzymatic reaction, was measured at a potential of 0.6 V (vs. SCE) in phosphate buffer solution. The performances of sensors, prepared at different monomer concentrations and polymerization potentials, were investigated in detail. The biosensor prepared under optimal conditions had a linear response to glucose ranging from 2.5 x 10(-4) to 1.5 x 10(-2) mol L(-1) with a correlation coefficient of 0.997 and a response time of less than 2 s. Substrate selectivity of the polymer-based enzyme electrode was tested for coexisting interferents such as uric acid and ascorbic acid, and no discernible response was observed. After 90 days, the response of the biosensor remained almost unchanged, indicating very good stability.

Biosensing Techniques↗

Use of a whole-cell biosensor and flow cytometry to detect AHL production by an indigenous soil community during decomposition of litter.

Quorum sensing, mediated by acylated homoserine lactones (AHLs), is well described for pure culture bacteria, but few studies report detection of AHL compounds in natural bacterial habitats. In this study, we detect AHL production during a degradation process in soil by use of whole-cell biosensor technology and flow cytometry analysis. An indigenous soil bacterium, belonging to the family of Enterobacteriaceae, was isolated and transformed with a low-copy plasmid harboring a gene encoding an unstable variant of the green fluorescent protein (gfpASV) fused to the AHL-regulated P(luxI) promoter originating from Vibrio fischeri. This resulted in a whole-cell biosensor, responding to the presence of AHL compounds. The biosensor was introduced to compost soil microcosms amended with nettle leaves. After 3 days of incubation, cells were extracted and analyzed by flow cytometry. All microcosms contained induced biosensors. From these microcosms, AHL producers were isolated and further identified as species previously shown to produce AHLs. The results demonstrate that AHL compounds are produced during degradation of litter in soil, indicating the presence of AHL-mediated quorum sensing in this environment.

4-Butyrolactone↗

Biosensors for heavy metals.

A biosensor is an analytical device that consists of an immobilized biocomponent in conjunction with a transducer, and represents a synergistic combination of biotechnology and microelectronics. This review summarizes the use of biosensors for detecting and quantifying heavy metal ions. Heavy metal contamination is of serious concern to human health since these substances are non-biodegradable and retained by the ecological system. Conventional analytical techniques for heavy metals (such as cold vapour atomic absorption spectrometry, and inductively coupled plasma mass spectrometry) are precise but suffer from the disadvantages of high cost, the need for trained personnel and the fact that they are mostly laboratory bound. Biosensors have the advantages of specificity, low cost, ease of use, portability and the ability to furnish continuous real time signals. The analysis of heavy metal ions can be carried out with biosensors by using both protein (enzyme, metal-binding protein and antibody)-based and whole-cell (natural and genetically engineered microorganism)-based approaches.

Biosensing Techniques↗

Investigation of interaction between two neutralizing monoclonal antibodies and SARS virus using biosensor based on imaging ellipsometry.

Two neutralizing human scFv, b1 and h12 were identified initially using ELISA,employing highly purified virus as the coating antigen. The biosensor technique based on imaging ellipsometry was employed directly to detect two neutralizing monoclonal antibodies and serial serum samples from 10 SARS patients and 12 volunteers who had not SARS. Further, the kinetic process of interaction between the antibodies and SARS-CoV was studied using the real-time function of the biosensor. The biosensor is consistent with ELISA that the antibody h12 showed a higher affinity in encountering the virus than antibody b1. The affinity of antibody b1 and antibody h12 was 9.5 x 10(6) M(-1) and 1.36 x 10(7) M(- 1), respectively. As a label free method, the biosensor based on imaging ellipsometry proved to be a more competent mechanism for measuring serum samples from SARS patients and the affinity between these antibodies and the SARS coronavirus.

Antibodies, Monoclonal↗

Determination of glutamic acid decarboxylase activity and inhibition by an H2O2-sensing glutamic acid oxidase biosensor.

The catalytic activity of the enzyme L-glutamic acid decarboxylase (GAD) is determined by an amperometric method based on a recently developed glutamate-selective biosensor. The biosensor is composed of an amperometric H2O2 electrode and a biocatalytic membrane containing the enzyme glutamic acid oxidase (GAO). The biosensor allows the direct and continuous measurement of GA levels by monitoring the H2O2 produced at the electrode interface as a coproduct of the GAO-catalyzed GA oxidation to alpha-ketoglutaric acid. Since GA is transformed to gamma-aminobutyric acid and CO2 under the catalytic activity of GAD, the rate of GA consumption in solution, monitored by the GAO biosensor, represents a reliable measure of GAD catalytic activity. Additional experiments performed in the presence of different concentrations of the GAD inhibitor valproic acid have shown the suitability of the proposed approach for the study of GAD inhibitors also. Discussion of the main experimental characteristics of this new analytical method is given in terms of sensitivity, reproducibility, and reliability of the experimental results and ease, time, and cost of operation.

Amino Acid Oxidoreductases↗

Synergies between micropreparative high-performance liquid chromatography and an instrumental optical biosensor.

The recent development of an automated surface plasmon resonance technology for the measurement of biomolecular interactions (Pharmacia BIAcore) has provided new opportunities for the detection and analysis of protein-protein interactions. In the BIAcore, detection is based on changes in surface plasmon resonance which are monitored optically. Changes in surface plasmon resonance correspond to changes in surface concentration of macromolecules and can be monitored in real time. We have found that the detection sensitivity obtainable with this technology (ng/ml concentrations of specific ligands are readily detectable for many applications) is complementary "in a bidirectional manner" to micropreparative HPLC. Thus micropreparative HPLC may be used to purify and characterise reagents for the biosensor, whilst the biosensor may be used to define chromatographic parameters such as elution conditions for affinity chromatography or serve as an affinity detector for fractions obtained during chromatographic purification. Examples of such applications, including the potential of the biosensor to search for and monitor the purification of unknown ligands for which the target molecule has been identified, are shown. In particular, the use of the biosensor to monitor the purification of soluble epidermal growth factor receptor from A431 cell conditioned media is demonstrated.

Biosensing Techniques↗

Biosensors for process control.

Biosensors have been extensively studied during the last 20 years, and a myriad of laboratory biosensors have been developed. Improvements are required in biosensor design and performance before they become widely accepted in industrial process monitoring. However, as the biotechnology industry expands, biosensors may become more acceptable because, despite their limitations, they are the only devices capable of delivering the information required.

Biosensing Techniques↗

Biosensors--what real progress is being made?

Biosensors have been hailed as the solution to many analytical problems in a wide range of industries. The heterogeneity of the proposed markets is equalled by that of the technologies called 'biosensors'. The many research groups worldwide are prolific in their publication of research papers and patents. Clearly, the field is not limited by a lack of information regarding the fundamental technology. However, there are, as yet, few successful commercial biosensor products available. The principle constraints on the commercial realization of such products concern the technical and manufacturing feasibility, market development and investment strategies. Whilst commercially viable biosensors will certainly emerge eventually, the timescale is longer than many would wish.

Biosensing Techniques↗

Whole-cell biosensors for environmental monitoring.

Concern over the pollution risk to drinking water from industry and agriculture is growing, and the need for continuous on-line monitoring recognised. There is increasing use of living organisms as the sensitive agent to detect the presence of pollutants, and whole-cell biosensors are seen to have particular advantages in such environmental monitoring. The development of a mediated amperometric biosensor, incorporating the cyanobacterium Synechococcus as the biocatalyst, for on-line herbicide monitoring is described. The biosensor is able to detect a wide range of herbicides with sites of action on the photosynthetic electron transport chain, at concentrations down to 20 micrograms litre-1 and possesses a working life of up to 7 days. The use of alginate immobilisation of the biocatalyst to overcome the problems associated with obtaining a realistic shelf life for the biosensor is discussed.

Biosensing Techniques↗

Uses of biosensor technology in the development of probes for viral diagnosis.

BACKGROUND: Since 1990, a new biosensor technology based on surface plasmon resonance makes it possible to visualize molecular recognition as a function of time, in terms of change in mass concentration occurring on a sensor chip surface. One of the reactants is immobilized on a dextran matrix while the other is introduced in a flow passing over the surface. The binding is followed in real time by the increase in refractive index caused by the mass of bound species. OBJECTIVES: In the present review, the applications of this new technology for developing probes intended for viral diagnosis will be described. STUDY DESIGN: In contrast with other immunoassay systems, the biosensor technique preserves the conformational integrity of the reactants since no labelling is required. It also makes it possible to follow every step of a multiple-layer assay and allows interaction measurements in real time. Suitable antigen and antibody probes can be selected on the basis of the conditions of the diagnostic assay that is being developed, especially in terms of affinity and specificity. RESULTS: Our results suggest that when the cyclic peptide 209-222 of the E1 protein of hepatitis C virus (HCV) is immobilized on the sensor chip via a biotin moiety, it retains a constrained conformation which is better recognized by HCV antibodies than the linear form. Data are presented which indicate that the biosensor technique facilitates the screening and selection of anti HIV-1 antibodies that are likely to possess the most potent neutralizing potential. CONCLUSION: Since there is a good correlation between BIAcore and ELISA data, it seems likely that the biosensor technology will be increasingly used for developing reagents intended for viral diagnosis.

Journal Article↗

Biochemical aspects of biosensors.

A review of the major types of biological molecules and systems (including antibodies, enzymes and whole cells) on which biosensors can be based is presented. Specific emphasis is placed on a critical assessment of the relative strengths and weaknesses of the respective technologies and on analysis of the importance of practical considerations such as sample interference, signal-to-noise ratio and biomolecule stability. The importance of efficient coupling of the biological and transducer components of a biosensor is highlighted. Future trends and directions in biosensor research and commercial aspects of the technology are also discussed. The article concludes with a summary of current biosensor research activities at the GEC-Marconi Hirst Research Centre.

Animals↗

Applied biosensors.

Biosensors are important analytical tools in clinical and environmental monitoring, biotechnological process control, medicine, and in the food and drink industry. This review devotes attention to the most common biosensor in biotechnology, the glucose biosensor, and to recent contributions to the rapidly growing field of optical biosensors. Trends and developments in these areas are discussed.

Animals↗

A reagent less fluorescent sol-gel biosensor for uric acid detection in biological fluids.

The simultaneous encapsulation of a coupled uricase-peroxidase system and amplex red in a sol-gel matrix allows one to obtain a reagent-less and ready-to-use fluorescent biosensor for the accurate detection of uric acid in highly diluted biological fluids. The detection limit of the prepared biosensor was found to be 20 nM and was linear up to 1 microM. The high sensitivity found for the biosensor permitted a reliable determination of uric acid concentrations in the presence of interfering species (e.g., ascorbic acid) just by sample dilution (up to 50000 for urine and 10000 for serum and blood). The sol-gel encapsulation preserved the hierarchy of the enzyme activity as demonstrated by the performance of the fluorescent biosensor.

Ascorbic Acid↗