PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Anatomic Landmarks”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17Linked to original sources

Retinal cartography.

This paper analyses retinal cartography in terms of its reflection of anatomic data and its relation to several forms of geographic methods of map-making. It shows that the distances between anatomic landmarks of the eye are reasonably similar to the relative distances on the retinal drawing chart currently used. Two forms of geographic cartography--azimuth equidistant and orthographic--are described and compared with retinal cartography. The retinal drawing chart currently used most closely approximates an azimuth equidistant projection, which suffers from circumferential distortion, a fact that retinal surgeons must keep in mind. It is therefore recommended that the chart be modified to have equally spaced concentric circles and clearer identification of the ora serrata; the present accurate marking of anatomic landmarks, such as the equator and the posterior border of the ciliary body, should be preserved.

Humans↗

Maxillary sinus mucocoeles--10 cases--8 treated endoscopically.

Maxillary sinus mucocoeles are rare, but may cause significant problems outside the sinus including diplopia and cheek swelling. We present 9 patients suffering from maxillary sinus mucocoele, including one patient with bilateral involvement, representing 10 involved sinuses. Eight sinuses were treated endoscopically and followed-up for 3 to more than 6 years; one of these developed a recurrence. Two sinuses were treated using a classical external approach (Caldwell-Luc), one at the beginning of our series, and one as the endoscopic technique was difficult to perform due to loss of anatomical landmarks. One of these two sinuses developed a recurrence and was then successfully treated endoscopically. We discuss the aetiology, pathogenesis and appropriate treatment of this unusual condition. Endoscopic treatment appears to be effective and leads to minimal recurrence. The aim is to perform a wide removal of the medial wall of the maxillary sinus including most of the inferior turbinate, immediately posterior to the lachrymal duct leaving intact the sinus mucosa. In some cases, however, the endoscopic technique can be difficult to perform due to loss of essential anatomical landmarks and in these cases recourse to an external approach may be necessary.

Adult↗

Registration accuracy and practicability of laser-directed surface matching.

The aim of our study was to evaluate the registration accuracy and practicability of a new laser registration technique in comparison to marker registration. From January to August 2001, 36 patients (23 male, 13 female) with brain lesions were operated with navigational guidance. Thirty-five patients were registered by paired-point registration. In 16 patients, a second registration was carried out using a special laser pointer for surface matching (z-touch trade mark, BrainLab, Heimstetten, Germany). Accuracy was evaluated by touching seven anatomic landmarks and a target fiducial with the nonsterile pointer. The distance from the virtual pointer tip to these points was determined on the monitor display (600% zoom). Laser registration is fully retrospective and allows registrations when no markers are applied. z-touch trade mark registration is more sophisticated and time-consuming than marker-based registration (registration time for z-touch trade mark = 7.4 +/- 3.7 min; for markers = 4.1 +/- 1.7 min; p < 0.005). Marker registration proved to be more accurate than z-touch trade mark registration with regard to localization of anatomical landmarks and target fiducials (precision with z-touch trade mark = 2.77 +/- 1.64 mm; with markers = 1.31 +/- 0.87 mm; p < 0.01). Although the registration error was increased and preparation time prolonged with the z-touch trade mark technique, it proved to be a valuable option, especially in children.

Adolescent↗

Spatial registration of echocardiographic and positron emission tomographic heart studies.

A method has been developed to match corresponding heart regions from functional echocardiographic (Echo) and metabolic fluorine-18-fluoro-2-deoxy-D-glucose ([18F]FDG) positron emission tomography (PET) studies in individual patients. Echo and PET images are spatially correlated by determining homologous anatomical landmarks (the two papillary muscles and the inferior junction of the right ventricle), identifiable in images obtained by both acquisition modalities. Echo-PET image registration is first performed in the plane identified by the three landmarks, using a rigid rotate-translate scale model. The registration parameters are then used to transform the whole PET volume. This allows a consistent Echo-PET regional analysis, according to a segmental subdivision of the heart. The technique was tested on patients. The overlay of Echo and PET registered images proved the reliability of realignment of the three markers and a good spatial correlation of myocardial walls. This approach to image registration could be applied to other acquisition modalities (such as magnetic resonance imaging and single-photon emission tomography), provided that the three anatomical landmarks are visualized.

Deoxyglucose↗

Kinematic analysis of human walking gait using digital image processing.

A system using digital image processing techniques for kinematic analysis of human gait has been developed. The system is cheap, easy to use, automated and provides useful detailed quantitative information to the medical profession. Passive markers comprising black annuli on white card are placed on the anatomical landmarks of the subject. Digital images at the standard television rate of 25 per second are acquired of the subject walking past a white background. The images are obtained, stored and processed using standard commercially available hardware, i.e. video camera, video recorder, digital framestore and an IBM PC. Using a single-threshold grey level, all the images are thresholded to produce binary images. An automatic routine then uses a set of pattern recognition algorithms to locate accurately and consistently the markers in each image. The positions of the markers are analysed to determine to which anatomical landmark they correspond, and thus a stick diagram for each image is obtained. There is also a facility where the positions of the markers may be entered manually and errors corrected. The results may be presented in a variety of ways: stick diagram animation, sagittal displacement graphs, flexion diagrams and gait parameters.

Algorithms↗

Supine approach to the sciatic nerve in the popliteal fossa.

PURPOSE: Sciatic nerve block in the popliteal fossa (popliteal nerve block, PNB) is an anaesthetic technique well-suited for operations below the knee. However, difficulty with positioning the patient in the prone position often precludes the classical, posterior approach to the block. In this report, an alternative approach to PNB that can easily be performed with a patient in the supine position is described. CLINICAL FEATURES: Three patients in whom the clinical circumstances precluded the use of the classical approach to PNB are described. In each case, PNB was performed using the alternative, supine approach. With a patient in the supine position, the leg is flexed at both the hip and knee, and supported by an assistant. After the anatomical landmarks of the popliteal fossa are identified, an insulated needle attached to a peripheral nerve stimulator is inserted 7 cm above the popliteal crease, 1 cm laterally to the midline and directed 45 degrees cephalad. Upon obtaining either dorsal or plantar flexion of the foot at the output current of 0.5 mAmp or less. 30-40 ml of local anaesthetic solution are injected. CONCLUSION: The supine approach to PNB allows the use of the block in patients that cannot be positioned in the prone position. Flexion of the leg at the knee greatly facilitates identification of the anatomical landmarks. When combined with a block of the femoral or saphenous nerve, this technique provides excellent anaesthesia for patients undergoing foot and ankle surgery.

Adult↗

Optimal CT evaluation for functional endoscopic sinus surgery.

PURPOSE: To evaluate the optimal parameters for the CT examination of patients who are having functional endoscopic sinus surgery. METHODS: CT scanning was performed on two fresh cadaveric heads in the direct coronal plane, varying the section thickness, intersection gap, scanner gantry angle, and amperage. The nasal cavity and paranasal sinuses were examined independently in a blinded fashion by four staff neuroradiologists and a staff otolaryngologist with special attention to 10 anatomic landmarks within the ostiomeatal unit that are considered important for preoperative planning. A score of 0 (nonvisualization/incomplete visualization) or 1 (clear/complete visualization) was assigned to each of these 10 landmarks. Analysis of variance was used in which reader, subject, and side were simultaneously controlled by "blocking." Multiple comparison methods (ie, Bonferroni) were used to compare the different protocols. RESULTS: We found a significant reduction in the delineation, and therefore the perception, of the ostiomeatal unit structures when the section thickness was greater than 5mm, any intersection gap was used, and the gantry angle was greater than 10 degrees from the plane perpendicular to the hard palate. However, a reduction in the radiation exposure from 200 mA to 80 mA did not affect the display of the anatomic landmarks. CONCLUSION: We found the optimal screening CT protocol for the paranasal sinuses to be a section thickness of 3 mm, no intersection gap, and a section angle within 10 degrees from the plane perpendicular to the palate. Also, owing to inherent contrast between air, soft tissue, and bone in the paranasal sinuses, a reduction in the radiation exposure parameter to 80 mA did not affect image quality.

Endoscopes↗

Assessment of tibial torsion employing fluoroscopy, computed tomography and the cryosectioning technique.

Accurate assessment of tibial torsion, particularly the rotational deformity of a stabilized tibial fracture, demands precise anatomic landmarks at the proximal and distal measuring sites of the tibia. A fluoroscopic method has been proposed, utilizing the orientation of the femoral condyles and the medial malleolus to constitute two lines of reference. The relevance of using these structures for the assessment was studied while employing fluoroscopy, computed tomography, and the cryosectioning technique in 10 necropsy specimens of the human tibia. In all specimens the lines of reference were determined by each method and the tibial torsion was measured as the angle between the lines. The medial malleolus and the femoral condyles were found to present reliable anatomic landmarks for determination of the lines of reference in all employed techniques. The maximum difference between results obtained with different methods in a given specimen was 5.4 degrees. The average difference between results with two techniques and two observers varied from 1.0 to 1.5 degrees. The reproducibility of the fluoroscopic method, described by the estimated standard error of a single determination, was 1.3 degree.

Fluoroscopy↗

A comparison of intertendinous and classical approaches to popliteal nerve block using magnetic resonance imaging simulation.

UNLABELLED: The classical approach to sciatic nerve block in the popliteal fossa (popliteal block) often requires multiple attempts to localize the sciatic nerve. Recently, it has been suggested that an intertendinous approach to popliteal block may result in a more consistent localization of the sciatic nerve. In the current study, we compared anatomical landmarks for the intertendinous and classical approaches to popliteal block with respect to the accuracy in localizing the sciatic nerve using magnetic resonance imaging simulation. Two anesthesiologists experienced in popliteal block drew landmarks for the intertendinous and classical approaches on 10 volunteers; a 1.5 Tesla superconducting magnet was used to obtain simultaneous, 10-mm thick, fast-spin echo proton density transverse axial sequences of the lower extremities. Using these acquired images, the two approaches were simulated off-line using previously identified landmarks. The spatial relationships of the simulated needle paths to the nerves and vessels in the popliteal fossa, as well as other relevant structures, were measured and compared. Simulation of the intertendinous approach to popliteal block resulted in needle-to-sciatic nerve contact in 14 legs (70%) versus 5 legs (25%) when the classical approach was used (P < 0.05). We conclude that the intertendinous approach might result in a more consistent localization of the sciatic nerve and may decrease the risk of sciatic vessel puncture. IMPLICATIONS: A simulation of popliteal block using magnetic resonance imaging in volunteers suggests that using tendons of the hamstring muscles as the anatomical landmarks yields a more consistent localization of the sciatic nerve.

Adult↗

Efficacy of computed tomographic image--guided endoscopic sinus surgery in residency training programs.

OBJECTIVE: To determine the efficacy of computed tomographic image-guided endoscopic surgery in the hands of inexperienced surgeons. STUDY DESIGN: Four second-year otolaryngology residents, with no prior experience performing ethmoidectomies, performed endoscopic sinus surgery (ESS) on formalin-fixed human cadaveric specimens with and without the aid of computer-assisted surgery (CAS). METHODS: Each resident was asked to identify critical sinus, orbital, and skull base structures while performing a total ethmoidectomy and multiple sinusotomies. Their surgical accuracy (percentage of correctly identified structures), total operative time, and incidence of major complications were recorded for each side. A total of 16 sides were evaluated (8 with and 8 without CAS). Statistical significance between groups was determined by means of Pearson's chi2 analysis. RESULTS: Statistical analysis showed a significant difference (P = .001) in the mean accuracy of identifying critical anatomical landmarks between the CAS (97%) and non-CAS (76.8%) groups. Although not statistically significant, operative time appeared to be longer in the group using CAS (average of 67 vs. 80 min). Three major intracranial complications were documented only in the group not using CAS. CONCLUSIONS: Although, unquestionably, a thorough knowledge of the anatomy remains essential for performing ESS, CAS improves surgical accuracy and reduces the risk of major intracranial or intraorbital complications for residents. In additional, our data suggest that this technology may enhance surgical efficiency and improve the learning curve by reducing operative time (below one's normal baseline) while maintaining a greater than 90% accuracy in identifying critical anatomical landmarks.

Clinical Competence↗

[Perioperative radiographic reconstruction of the scoliotic vertebral column].

We have developed a new per-operative three dimensional (3D) reconstruction technique to evaluate the 3D correction of a scoliotic spine induced by surgery using Cotrel-Dubousset instrumentation. A small object with 15 embedded markers was used to calibrate the radiographic system. During surgery, the calibration object was sterilized and fixed to the patient just before the acquisition of two pairs of posterior-anterior and sagittal radiographs; one pair before the rotation maneuver of the rod and one pair after the maneuver. The markers were digitized on each radiograph and their relative 3D positions were measured to establish the relation between the 3D positions of the anatomical structures and their 2D positions on the radiographs. This relation was used to calculate the 3D position of six anatomical landmarks per vertebra (the centers of the superior and inferior vertebral body endplates and the proximal and distal bodies of both pedicles) from the identification of these landmarks on each radiograph. We made a 3D representation of the thoracic and lumbar spine of three patients with idiopathic scoliosis undergoing corrective surgery by the posterior approach. Clinical indices (Cobb angle, axial rotation and the plane of maximum curvature) computed from the 3D reconstruction of the spine obtained before and after the rotation maneuver of the rod were compared to evaluate the 3D correction performed during the surgery. The new proposed approach allows the surgeon to evaluate the per-operative shape of the spine. This approach is simpler, faster and less risky for the patient than the previous method which employed an electromagnetic digitizer to measure the 3D coordinates of anatomical landmarks located on the posterior part of the spine. Furthermore, the 3D representation of the spine visualized from different points of view gives the surgeon an accurate evaluation of the 3D correction during the surgical procedure.

Adolescent↗

Quantification of true in vivo (application) accuracy in cranial image-guided surgery: influence of mode of patient registration.

OBJECTIVE: Very few studies have attempted to quantify the true (application) accuracy of image-guidance systems during craniotomy. This is, in part, because of the lack of millimetric intraoperative targets to allow such measurements. Few in vivo studies have compared the influence of mode of patient registration on subsequent true accuracy. METHODS: Seven modes of patient registration (anatomic landmarks, 5 or 10 adhesive fiducials, bone-implanted fiducials [Stryker-Leibinger], surface matching using 45 or 100 points over scalp convexity or nose/auditory meatus contours) were compared. Thirty patients were involved in the study. Millimetric targets (bone drill holes or deep 1-mm titanium hemoclips) were placed then localized and saved at surgery. These targets were then identified on postoperative volumetric computed tomography fused with operative data sets. Localization errors of the targets were measured for each registration on an optical image-guidance system (StealthStation). RESULTS: Only implanted cranial fiducials had a statistically significant accuracy advantage (1.7 +/- 0.7 mm). All other registrations had similar accuracies (approximately 4.0 +/- 1.7 mm) except anatomic landmarks, which were worse (4.8 +/- 1.9 mm). Calculated accuracies (root mean squared) had no predictive value for true (application) accuracies. CONCLUSION: Not surprisingly, application accuracy of image-guidance is worse without implanted cranial markers. Unexpectedly, there was no major difference in localization of deep targets between the other registrations tested in this study. Care must be taken when using image-guidance tools to consider error introduced by registration. Cranium-implanted fiducials should be considered when high accuracy and reproducibility are needed.

Anthropometry↗

Accuracy evaluation of a CAS system: laboratory protocol and results with 6D localizers, and clinical experiences in otorhinolaryngology.

OBJECTIVES: The objective of the study reported in this article was to evaluate (1) localizer inaccuracies, one of the major sources of errors in Computer-Assisted Surgery (CAS) systems, and (2) the final errors obtained using surface-based registration in ear, nose, and throat (ENT) surgery. These objectives were met through (1) a technical evaluation of the accuracy and usability of several optical localizers under laboratory test conditions, and (2) a clinical measure of the global errors obtained when using a CAS system including one of the standard localizer systems (Flashpoint 5000) in Functional Endoscopic Sinus Surgery (FESS). PATIENTS AND METHODS: The technical evaluation of localizers consisted of series of geometric tests on four commercial systems. Clinical evaluation included the development of a laboratory CAS system using a markerless, skin surface registration method. This was based on a standard optical digitizing system (Flashpoint 5000), which eliminates the need for the second CT scan, which is normally performed specifically to process the position of the fiducial markers. Global accuracy was then evaluated on 20 patients by subjective and visual comparison when placing a calibrated pointer on anatomical landmarks. RESULTS: The results of the technical study indicate that the four commercial systems tested have levels of inaccuracy deemed acceptable for most CAS applications, including ENT surgery. The clinical study obtained a registration and calibration accuracy of less than 1.5 mm in 89.2% (SD = 0.20 mm) of the cases studied. Our markerless skin surface points registration method is reliable, and allows patient head movements during the procedure. The accuracy tests performed show that this type of system can be used for ENT surgery with satisfaction. CONCLUSION: CAS systems enable the surgeon to have a more thorough understanding of the complicated anatomy of paranasal sinuses, and may be especially helpful in revision surgery when normal anatomic landmarks are lacking. Further studies are necessary in FESS to improve the CAS systems that are currently available, and to determine whether these systems can minimize the overall risk of complications.

Computer Systems↗

Identification of thoracic intervertebral spaces by means of surface anatomy: a magnetic resonance imaging study.

BACKGROUND: Successful thoracic epidural analgesia depends on the sensory blockage of specific dermatomes following appropriate placement of the epidural catheter. This study aimed to ascertain how accurately anaesthesiologists identify thoracic intervertebral spaces, and whether counting from the prominent vertebra is easier than using the iliac crest as an anatomical landmark. METHODS: Five anaesthesiologists attempted to locate one out of five consecutive intervertebral spaces (Th7-Th8 to Th11-Th12) on patients referred for magnetic resonance imaging of the vertebral column. The intended thoracic interspace and the counting reference point (C7-Th1 or L3-L4) were marked with oil capsules. The body mass index, gender and position of the patient were recorded. The exact capsule positions were determined by a radiologist after the study. RESULTS: In 92 patients, 26.7% of the thoracic interspaces were correctly identified. The counting reference point was the only variable studied with a significant influence on error. The accuracy increased when the iliac crest was used as an anatomical landmark rather than the prominent vertebra (odds ratio, 0.29). The majority (76.4%) of all the incorrectly placed capsules were found cephalad to the intended level. CONCLUSION: We recommend that the caudal of two to three possible interspaces should be used when placing an epidural catheter in the thoracic spine. Because of the inaccurate localization of the thoracic intervertebral spaces, documentation should state the site of puncture as being in the upper or lower thoracic spine instead of claiming to be in an exact interspace.

Adolescent↗

The personal digital assistant (PDA) as a tool for telementoring endoscopic procedures.

The telementoring of surgical procedures is currently achieved via a wired infrastructure that usually requires sophisticated videoconference systems. This project represents the first step in assessing the potential for using handheld computers as a mobile alternative to current telementoring systems. Specifically, this project compares a handheld computer to a standard CRT monitor regarding their capability to accurately display video images from an endoscopic procedure. Video images from two previously recorded endoscopic procedures were transmitted from a standard VCR to: 1) a handheld computer (iPAQ 3670 running Pocket PC) via a wireless LAN and 2) a standard CRT monitor via a wired analog connection. The software-used on the handheld device was custom designed to allow 320 X 240 pixel video images to be broadcast in real time. Twenty-three surgical residents who had completed an endoscopy rotation were randomized to watch one of the two videotaped endoscopic procedures on the hand held computer or on the CRT monitor. After viewing the procedure, a ten-question quiz was used to assess the ability of each participant to recognize several anatomic landmarks. The result of each questionnaire was expressed as the percentage of correct responses. Using a crossover design, each participant then viewed the other videotaped procedure using the alternate device and completed a second quiz. The mean test score for each device was calculated, and these data was analyzed using a Student T test. The observed difference between the mean test score associated with the handheld device (77.93 +/- 11.26) and the CRT monitor (81.30 +/- 12.54) was not statistically significant (p<0.41). In addition, regardless of the device used, scores corresponding to video tape one were significantly higher than those recorded for video tape two (84.35 +/- 9.92 vs. 74.35 +/- 11.61; p < 0.01) All participants were able to recognize anatomic landmarks equally well when viewing broadcasted endoscopic procedures on a handheld display or a standard CRT monitor. Handheld computers may have a role in telementoring residents who are performing endoscopic procedures. Further research is needed to evaluate the integration of handheld devices into telementoring and robotic system to perform surgical procedures.

Computers, Handheld↗

Symmetry of oculomotor burst neuron coordinates about Listing's plane.

1. The purpose of this investigation was to determine the axes of eye rotation generated by oculomotor burst neuron populations and the coordinate system that they collectively define. In particular, we asked if such coordinates might be related to constraints in the emergent behavior, i.e., Listing's law for saccades. 2. The mesencephalic rostral interstitial nucleus of the medial longitudinal fasciculus (riMLF) was identified in four monkeys with the use of single-unit recording, and then explored with the use of electrical microstimulation and pharmacological inactivation with the inhibitory gamma-aminobutyric acid (GABA) agonist muscimol. Three-dimensional (3-D) eye positions and velocities were recorded in one or both eyes while alert animals made eye movements in response to visual stimuli and head rotation. 3. Unilateral stimulation of the riMLF (20 microA, 200 Hz, 300-600 ms) produced conjugate, constant velocity eye rotations, which then stopped abruptly and held their final positions. This is expected if the riMLF produces phasic signals upstream from the oculomotor integrator. 4. Units that burst before upward or downward saccades were recorded intermingled in each side of the riMLF. Unilateral stimulation of the same riMLF sites produced eye rotations about primarily torsional axes, clockwise (CW) during right riMLF stimulation and counterclockwise (CCW) during left stimulation. Only small and inconsistent vertical components were observed, supporting the view that the riMLF carries intermingled up and down signals. 5. The torsional axes of eye rotation produced by riMLF stimulation did not correlate to external anatomic landmarks. Instead, stimulation axes from both riMLF sides aligned with the primary gaze direction orthogonal to Listing's plane of eye positions recorded during saccades. 6. Injection of muscimol into one side of the riMLF produced a conjugate deficit in saccades and quick phases, including a 50% reduction in all vertical velocities and complete loss of one torsional direction. CW was lost after right riMLF inactivation, and CCW was lost after left inactivation. 7. The plane that separated the intact torsional axes from the missing axes correlated with the orientation of Listing's plane. Thus, during left or right riMLF inactivation, the vertical axes of intact horizontal saccades were abnormally aligned with Listing's plane. The orientation of these axes was not correlated with external anatomic landmarks. 8. As suggested by their alignment with Listing's plane, the intact vertical axes of horizontal saccades following riMLF inactivation were orthogonal to torsional riMLF stimulation axes.(ABSTRACT TRUNCATED AT 400 WORDS)

Algorithms↗

Morphometric analysis of implant-related anatomy in Caucasian skulls.

BACKGROUND: Sequelae related to implant placement/advanced bone grafting procedures are a result of injury to surrounding anatomic structures. Damage may not necessarily lead to implant failure; however, it is the most common cause of legal action against the practitioner. This study aimed to describe morphological aspects and variations of the anatomy directly related to implant treatment. METHODS: Morphometric analyses were performed in 22 Caucasian skulls. Measurements of the mental foramen (MF) included height (MF-H), width (MF-W), and location in relation to other known anatomical landmarks. Presence or absence of anterior loops (AL) of the inferior alveolar nerve (IAN) was determined, and the mesial extent of the loop was measured. Additional measurements included height (G-H), width (G-W), thickness (G-T), and volume (G-V) of monocortical onlay grafts harvested from the mandibular symphysis area, and thickness of the lateral wall (T-LW) of the maxillary sinus. The independent samples t test, and a two-tailed t test with equal variance were utilized to determine statistical significance to a level of P < 0.05. Multiple regression analyses were performed to determine if each one of these measurements was affected by age and gender. RESULTS: The most common location of the MF in relation to teeth was found to be below the apices of mandibular premolars. The mean MF-H was 3.47 +/- 0.71 mm and the mean MF-W was 3.59 +/- 0.8 mm. The mean distance from the MF to other anatomical landmarks were: MF-CEJ = 15.52 +/- 2.37 mm, MF to the most apical portion of the lower cortex of the mandible = 12.0 +/- 1.67 mm, MF to the midline = 27.61+/- 2.29 mm, and MF-MF = 55.23 +/- 5.34 mm. A high prevalence of AL was found (88%); symmetric occurrence was a common finding (76.2%), with a mean length of 4.13 +/- 2.04 mm. The mean size of symphyseal grafts was: G-H = 9.45 +/- 1.08 mm, G-W = 14.5 +/- 3.0 mm, and G-T = 6.15 +/- 1.04 mm, with an average G-V of 857.55 +/- 283.97 mm3 (range: 352 to 1,200 mm3). The mean T-LW of the maxillary sinus was 0.91 +/- 0.43 mm. CONCLUSION: Implant-related anatomy must be carefully evaluated before treatment due to considerable variations among individuals, in order to prevent injury to surrounding anatomical structures and possible damage.

Aged↗

Clinical and radiological results after parapedicular screw fixation of the thoracic spine.

OBJECT: The proximity of thoracic pedicles to the spinal cord and neurovascular structures has prompted numerous efforts to obtain proper screw placement. The aim of this study was to evaluate the feasibility and efficacy of thoracic parapedicular (intercostovertebral) screw fixation by following anatomical landmarks and using fluoroscopy. METHODS: Thoracic parapedicular screw fixation was performed in 41 patients (328 screws). Postoperative computerized tomography scans were obtained in all cases to analyze the position of each screw with respect to the pedicle rib unit, the spinal canal, and the vertebral body (VB) according to a proposed novel grading system. Additionally, screw convergence angles were calculated for each instrumented level. There was no additional morbidity associated with parapedicular screw insertion. In a single case a screw suspected of entering the spinal canal was revised without causing neurological damage. The remaining screws were placed entirely within the pedicle rib unit and VB without breaching the neural foramina, pleura, or vascular structures. CONCLUSIONS: Thoracic and thoracolumbar instability can be treated adequately and safely by using parapedicular screw fixation guided by anatomical landmarks and fluoroscopic imaging. The use of computer-aided navigation may be beneficial but does not appear to be mandatory.

Aged↗