PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “COMPRESSION”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17Linked to original sources

Thoracolumbar spine mechanics contrasted under compression and shear loading.

The mechanical properties of the human spine have been studied extensively in compression, but there remains a lack of fundamental data in shear. The overall goal of this study was to contrast the mechanics of the thoracolumbar functional spinal unit (FSU) under compression and shear-type loads by evaluating endplate deformation, disc pressures, and kinematics between the different loading types. Eleven T12-L1 and one L1-L2 human FSUs were tested. Compression loads consisted of pure compression, extension-compression, flexion-compression, lateral left and right compression applied individually to a maximum of 500 N. Shear loading consisted of posterior, anterior, left, and right shear to a maximum of 500 N. Intervertebral motions, disc pressure, and vertebral body deformations were recorded for all loads. The deformations were measured using strain gauge rosettes at three points on the inferior vertebral body and one on the superior endplate of the inferior vertebra. The disc pressures and endplate deformations measured were significantly less in shear loading compared to compression and did not change significantly with the type of compression load. Vertebral rim strains were generally greater under shear loading compared with compression. The mechanics of load transfer in compression was the production of high disc pressures which were not linearly correlated with the central endplate deformation. In shear, the mechanism appears to be via the annulus fibrosus without the development of significant disc pressure. These differences between compression and shear loading may have implications for injury mechanisms in the thoracolumbar spine.

Adult↗

Effects of tourniquet compression on neuromuscular function.

Neuromuscular function in New Zealand White rabbits was evaluated after thigh tourniquet compression in the directly compressed quadriceps muscles and the distal tibialis anterior by measuring isometric contractile function after supramaximal stimulation of the motor nerve. Tourniquet compression resulted in markedly decreased force production beneath and distal to the tourniquet. Two days after compression, maximal quadriceps force production was decreased to 46% of control values with 125 mm Hg compression and 21% of control values after 350 mm Hg compression. Maximum tibialis anterior force production declined to 70% of control values after 125 mm Hg thigh compression and 24% of control values after 350 mm Hg thigh compression. Functional deficits were greater in the directly compressed quadriceps muscles, but the quadriceps and tibialis anterior had significantly increased impairment when the tourniquet inflation pressure was increased from 125 mm Hg to 350 mm Hg. Three weeks after compression, quadriceps function had returned to 94% of control value after 125 mm Hg compression and 83% after 350 mm Hg. Tibialis anterior function returned to 88% of control values after 125 mm Hg thigh compression and 83% after 350 mm Hg. Clinically, the use of lower inflation pressures may minimize the complications of tourniquet use and enhance postoperative recovery.

Animals↗

Changes in nerve function and nerve fibre structure induced by acute, graded compression.

Rabbit tibial nerves were subjected to direct, acute graded compression by means of an inflatable compression chamber. The acute and long term effects of 50, 200 and 400 mmHg applied for two hours on nerve function and nerve fibre structure were investigated. A pressure of 50 mmHg applied for two hours induced only minimal or no acute deterioration of maximal conduction velocity and nerve fibre structure. Conduction velocity was gradually reduced during compression at 200-400 mmHg pressure for two hours and in those cases the recovery of nerve conduction after pressure release was incomplete. Ultrastructural analysis revealed pronounced, early nerve fibre damage in these nerves. Three weeks after compression, nerves compressed at 50 mmHg for two hours had normal afferent and motor conduction velocity, although there were morphological signs of slight nerve fibre damage. Nerves compressed at 200 mmHg for two hours exhibited reduction of conduction velocity only at the level of compression, in contrast to the nerves compressed at 400 mmHg for two hours in which conduction velocity was reduced both at the level of compression and distal to the compressed segment. Morphologically, the nerves compressed at 200-400 mmHg for two hours showed varying degrees of demyelination and axonal degeneration three weeks after compression.

Action Potentials↗

Effect of CT image compression on computer-assisted lung nodule volume measurement.

PURPOSE: To evaluate the effect of two-dimensional wavelet-based computed tomographic (CT) image compression according to the Joint Photographic Experts Group (JPEG) 2000 standard on computer-assisted assessment of nodule volume. MATERIALS AND METHODS: This HIPAA-compliant study was approved by the research board at the authors' institution; patients' informed consent was not required. Fifty-one nodules in 23 patients (seven men, 16 women; mean age, 59 years; age range, 39-75 years) were selected on low-dose CT scans that were compressed to levels of 10:1, 20:1, 30:1, and 40:1 by using a two-dimensional JPEG 2000 wavelet-based image compression method. Nodules were classified according to size (< or = 5 mm or > 5 mm in diameter), location (central, peripheral, or abutting pleura or fissures), and attenuation (solid, calcified, or subsolid). Regions of interest were placed on the original images and transposed onto compressed images. Nodule volumes on original (noncompressed) and compressed images were measured by using a computer-assisted method. A mixed-model analysis of variance was conducted for statistical evaluation. RESULTS: Nodule volumes averaged 388.1 mm3 (range, 34-3474 mm3). There were three calcified, 33 solid noncalcified, and 15 subsolid nodules (13 with ground-glass attenuation). Average volume decreased with increasing compression level, to 383 mm3 (10:1), 370 mm3 (20:1), 360 mm3 (30:1), and 354 mm3 (40:1). No significant difference was identified between measurements obtained on original images and those compressed to a level of 10:1. Significant differences were noted, however, between original images and those compressed to a level of 20:1 or greater (P < .05). Compression level significantly interacted with nodule size, location, and attenuation (P < .001). The effect of compression was greater for nodules with ground-glass attenuation than for those with higher attenuation values. The difference in mean volumes between original images and those compressed to a level of 20:1 was 34.9 mm3 for nodules with ground-glass attenuation, compared with 8.3 mm3 for higher-attenuation nodules, a 4.2-fold difference. CONCLUSION: Nodule volumes measured on images compressed to a level of 20:1 differed significantly from those measured on noncompressed images, especially for nodules with ground-glass attenuation. This difference could affect the assessment of nodule change in size as measured with computer-assisted methods.

Adult↗

Tensile and compressive responses of nociceptors in rat hairy skin.

Mechanically sensitive nociceptor afferents were studied in a preparation of isolated skin from rat leg. Each neuron was studied while the skin was subjected to tensile and compressive loading. The experiment was designed to create highly uniform states of stress in both tension and compression. Tensile loads were applied by pulling on the edges of the sample. Applied loads were used to determine the tensile stresses. Surface displacements were used to determine tensile strains. Compressive loads were applied by indenting the surface of the skin with flat indenter tips applied under force control. The skin was supported by a flat, hard substrate. Compressive stresses were determined from the applied loads and tip geometry. Compressive strains were determined from skin thickness and tip excursions. All nociceptors were activated by both tensile and compressive loading. There was no interaction between the responses to compressive and tensile stimuli (i.e., the responses were simply additive). Responses of nociceptors were better related to tensile and compressive stresses than to strains. Nociceptors responded better to tensile loading than to compressive loading. Response thresholds were lower and sensitivities were higher for tensile stress than for compressive stress. The response to compression was better related to compressive stress than to other stimulus parameters (i.e., load/circumference or simply load). Indentations of intact skin over a soft substrate such as muscle would be expected to cause widespread activation of nociceptors because of tensile stresses.

Animals↗

Reflex activity and axonal conduction in the L-7 spinal cord segment following experimental compression trauma.

In cats in which the spinal cord was transected at C-1, the exposed L-7 spinal cord segment was compressed with an electromagnetically driven rod applied to the dorsal surface of the segment. With the magnitude of compression constant at 3 mm, the cord was compressed for durations of 50 msec, 0.5 sec, or 1.0 sec. Polysynaptic reflex discharges integrated in the injured segment and action potentials conducted in dorsal column axons traversing the same region were electrophysiologically measured before, during, and for 41/2 hours after trauma. Structural changes were evaluated on frozen serial sections obtained both from compressed segments and from tissue adjacent to the injury. At a compression duration of 50 msec, the amplitude of evoked reflex activity decreased abruptly, and dorsal column axonal conduction was blocked for 1 minute following compression. This early-phase response was followed by partial recovery of both functions which persisted until the end of the experiment. Prolonging compression to 0.5 sec brought about a further decrease of polysynaptic reflex activity. Axonal conduction was also decreased, but not significantly. With compression lasting 1.0 sec, no significant changes in reflex discharges and axonal conduction occurred compared with those measured at 0.5 sec. Neither function was abolished, even after the longest compression time. Prolongation of compression significantly increased both the intensity and the spread of edema, whereas changes in hemorrhage were not significant. Thus, a plateau rather than a progressive increase in severity of functional and structural posttraumatic changes was reached by increasing the duration of compression. This injury model reduces the sources of variability found in other experimental compression trauma models and permits the quantitative assessment of basic spinal cord mechanisms and correlated histopathological changes in the same preparation following trauma.

Animals↗

Demonstration of neurovascular compression in trigeminal neuralgia with magnetic resonance imaging. Comparison with surgical findings in 52 consecutive operative cases.

Until recently, the inability to demonstrate neurovascular compression of the trigeminal nerve preoperatively resulted in surgery being offered only in cases of severe trigeminal neuralgia (TGN), frequently after a prolonged trial of medical treatment and following less invasive procedures, despite the fact that posterior fossa microvascular decompression gives long-term pain relief in 80% to 90% of cases. To assess whether vascular compression of the nerve could be demonstrated preoperatively, high definition magnetic resonance tomographic angiography (MRTA) was performed in 50 consecutive patients, five of whom had bilateral TGN, prior to posterior fossa surgery. The imaging results were compared with the operative findings in all patients, including two patients who underwent bilateral exploration. Vascular compression of the trigeminal nerve was identified in 42 of 45 patients with unilateral symptoms and on both sides in four patients with bilateral TGN. In the last patient with bilateral TGN, neurovascular compression was identified on one side, and on the other side the compressing superior cerebellar artery was separated from the nerve by a sponge placed during previous surgery. There was full agreement regarding the presence or absence of neurovascular compression demonstrated by MRTA in 50 of 52 explorations, but MRTA misclassified four vessels compressing the trigeminal nerve as arteries rather than veins. In two cases, there was disagreement between the surgical and MRTA findings. In the first of these cases, surgery revealed distortion of the nerve at the pons by a vein that MRTA had predicted to lie 6 mm remote from this point. In the second patient, venous compression was missed; however, this patient was investigated early in the series and did not have gadolinium-enhanced imaging. In nine cases, MRTA correctly identified neurovascular compression of the trigeminal nerve by two arteries. Moreover, MRTA successfully guided surgical reexploration in one patient in whom a compressing vessel was missed during earlier surgery and also prompted exploration of the posterior fossa in two patients with multiple sclerosis and one patient with Charcot-Marie-Tooth syndrome, in whom neurovascular compression was identified preoperatively. It is concluded that MRTA is an extremely sensitive and specific method for demonstrating vascular compression in TGN. As a result, open surgical procedures can be recommended with confidence, and microvascular decompression is now the treatment of choice for TGN at the authors' unit. They propose MRTA as the definitive investigation in such patients in whom surgery is contemplated.

Aged↗

Intelligibility and comprehension of time compressed sign language narratives.

A method of time compressing visual displays was devised to assess the effects of compression on the comprehension of American sign language (ASL). Two ASL narratives were visually presented to three groups of deaf ASL users. A compression group was presented narratives compressed to 50% of the duration of the normal rates. A no-compression group was presented narratives signed at normal rates. A pause groups was presented compressed narratives with blank pauses inserted so that the total time per narrative was equal to that of the no-compression versions. Following each narrative, subjects completed a written comprehension task. Comprehension in both compression and pause groups was significantly lower than in the no-compression group. Pauses did not significantly affect scores relative to compression. An additional group of deaf ASL users was presented an intelligibility task in which signs taken from the narratives were presented in isolation either with or without compression. The total number of signs correctly identified was significantly lower with compression. Decrements in comprehension were best explained as the result of cumulative decrements in sign intelligibility and not as the result of decrements in available processing time.

Deafness↗

In vitro evaluation of ureteral stent compression.

OBJECTIVES: To evaluate the force required to radially compress ureteral stents and the impact of compression on stent performance across a broad range of stent sizes and manufacturers. METHODS: Fourteen ureteral stents ranging in size from 6F to 10.3F were evaluated for radial compression using an MTS Micro Bionix Testing System using Testworks II software, 5N load cell, vibration isolation table, and socket set screws with rounded caps. Radial compression was exerted in 0.2-mm increments. Cycles of compression and a 100-second hold time were repeated for each stent to maximal compression. Three trials were completed for each stent. The Young's Modulus, E, was calculated from each trial using the engineering stress. Simultaneous flow data using normal saline were collected for the Amplatz stent. RESULTS: The Cook C-Flex (E = 30,355 +/- 910 Pa), Microvasive Percuflex Plus 6F (E = 28,973 +/- 250 Pa), Cook EndoSof (E = 28,403 +/- 471 Pa), and Fossa Open Lumen (E = 28,627 +/- 5,338) were the most resistant to compression and the Cook Amplatz 10.2F (E = 11,922 +/- 220 Pa) and Microvasive Percuflex Plus 10.3F (E = 8,247 +/- 286 Pa) were the least resistant to compression. Stress relaxation occurred similarly in all stents. Flow through the Cook Amplatz stent decreased at a rate of 5 mL/s/mm of compression linearly (R2 = 0.95). CONCLUSIONS: Stents resistant to radial compression are critical for function in the face of extrinsic ureteral obstruction. The Cook C-Flex ureteral stent resisted extrinsic compressive forces best. Although large-lumen stents are often used in this clinical situation, they were the most susceptible to compressive forces.

Equipment Design↗

External compression dressing versus standard dressing after axillary lymphadenectomy.

BACKGROUND: Closed-catheter drainage after axillary lymph node dissection (ALND) for breast cancer may constitute a significant inconvenience to the recovering patient, and may also serve as portals of entry for bacteria. Any intervention that could reduce the volume and duration of postoperative drainage would be beneficial. The purpose of this study was to determine whether an external compression dressing after ALND would decrease postoperative drainage, afford earlier drain removal, and reduce subsequent seroma formation. PATIENTS AND METHODS: One hundred thirty-five women undergoing definitive surgical treatment for breast cancer were randomized to receive a compression dressing (n = 66) or standard dressing (n = 69). They were also stratified for modified radical mastectomy (MRM; n = 74) or breast conservation therapy (BCT; n = 61). All patients had ALND. The compression dressing consisted of a circumferential chest wrap of two 6-inch Ace bandages, held in place by circumferential Elastoplast bandage, and it was applied by the same nurse. This dressing remained intact until postoperative day 4. Patients in the standard dressing group (control) were fitted with a front-fastening Surgibra only. Drains were removed when the total daily amount was <50 cc. Postoperative drainage volume, total days with drain, and frequency of seroma formation were recorded for each patient. RESULTS: After 4 days, wound drainage in both groups was nearly identical (compression = 490 cc, standard = 517 cc; P = 0.48). Total days with drain were also similar (compression = 6.4 days, standard = 6.1 days; P = 0.69). The compression dressing did not reduce seroma formation. In fact, there was a statistically significant increase in the number of seroma aspirations per patient in the compression group (compression = 2.9, standard = 1.8; P <0.01). The increase in seroma aspirations was more significant in MRM patients (compression = 3.1, standard = 1.7; P <0.01) than in BCT patients (compression = 2.6, standard = 1.8; P = 0.20). CONCLUSIONS: External compression dressing fails to decrease postoperative drainage and may increase the incidence of seroma formation after drain removal. Thus, routine use of a compression dressing to reduce postoperative drainage after ALND for breast cancer is not warranted.

Axilla↗

Quality of cardiac massage with ratio compression-ventilation 5/1 and 15/2.

OBJECTIVE: The aim of this study is to study the quality of chest compressions over a period of 5 min with a compression-ventilation ratio of 5/1 and 15/2. MATERIAL AND METHODS: This prospective study was carried out with an electronic CPR manikin (ResusciAnne with Skillmeter; Laerdal). The participants were 'ambulancier SMUR' (Emergency and Resuscitation Mobil Unit) belonging to a French prehospital emergency team. They all have been trained in cardiopulmonary resuscitation (CPR) and are certified to perform CPR. The quality of chest compression has been evaluated according to the international recommendations. Each participant provided CPR with ratio 5/1 and 15/2. RESULTS: Twenty-one subjects participated in this experiment. The mean number of attempted compressions per min was 69.24 (S.D.=8.7) for a ratio of 5/1 and 79.26 (S.D.=6.7) for a ratio of 15/2. The rates achieved were similar between the two ratios with, respectively, a mean of 103.5 and 112 per min. The mean correct compression was 56.5 (S.D.=15.7) per min for group 5/1 and 44.16 (S.D.=24.8) for group 15/2. Quality of closed chest compression was very significantly better with a ratio of 5/1 than 15/2 (P=0.0002). A significant decrease in compression quality has been found over the time for a ratio of 15/2 (P=0.011). No correlation between correct compression and duration appeared for group 5/1. Incorrect location on sternum was 24 times most frequent with a ratio of 15/2 than ratio 5/1. Compression of insufficient depth remained the most frequent error both with ratio 5/1 and 15/2 and was 2.2 times more frequent with a ratio of 15/2 than a ratio of 5/1. CONCLUSION: Effective closed chest compression was significantly better with a ratio of 5/1 than 15/2. Better management of cardiac arrest suggested by an increase in a number of compressions with a ratio of 15/2 could be attenuated by cardiac compressions of lesser quality.

Adult↗

Impact of JPEG lossy image compression on quantitative digital subtraction radiography.

OBJECTIVES: The aim of the study was to evaluate the impact of JPEG lossy image compression on the estimation of alveolar bone gain by quantitative digital subtraction radiography (DSR). METHODS: Nine dry domestic pig mandible posterior segments were radiographed three times ('Baseline', 'No change', and 'Gain') with standardized projection geometry. Bone gain was simulated by adding artificial bone chips (1, 4, and 15 mg). Images were either compressed before or after registration. No change areas in compressed and subtracted 'No change-Baseline' images and bone gain volumes in compressed and subtracted 'Gain-Baseline' images were calculated and compared to the corresponding measurements performed on original subtracted images. RESULTS: Measurements of no change areas ('No change-Baseline') were only slightly affected by compressions down to JPEG 50 (J50) applied either before or after registration. Simulated gain of alveolar bone ('Gain-Baseline') was underestimated when compression before registration was performed. The underestimation was bigger when small bone chips of 1 mg were measured and when higher compression rates were used. Bone chips of 4 and 15 mg were only slightly underestimated when using J90, J70, and J50 compressions before registration. CONCLUSIONS: Lossy JPEG compression does not affect the measurements of no change areas by DSR. Images undergoing subtraction should be registered before compression and if so, J90 compression with a compression ratio of 1:7 can be used to detect and measure 4 mg and larger bone gain.

Alveolar Process↗

A comparison of active compression-decompression cardiopulmonary resuscitation with standard cardiopulmonary resuscitation for cardiac arrests occurring in the hospital.

BACKGROUND: Recent studies have demonstrated improved cardiopulmonary circulation during cardiac arrest with the use of a hand-held suction device (Ambu CardioPump) to perform active compression-decompression cardiopulmonary resuscitation (CPR). The purpose of this study was to compare active compression-decompression with standard CPR during cardiac arrests in hospitalized patients. METHODS: All patients over the age of 18 years who had a witnessed cardiac arrest while hospitalized at our center were enrolled in this trial; they were randomly assigned according to their medical-record numbers to receive either active compression-decompression or standard CPR. The study end points were the rates of initial resuscitation, survival at 24 hours, hospital discharge, and neurologic outcome. Compressions were performed according to the recommendations of the American Heart Association (80 to 100 compressions per minute; depth of compression, 3.8 to 5.1 cm [1.5 to 2 in.]; and 50 percent of the cycle spent in compression). RESULTS: Sixty-two patients (45 men and 17 women) with a mean age (+/- SE) of 68 +/- 2 years were entered into the trial. Sixty-two percent of the patients who underwent active compression-decompression were initially resuscitated, as compared with 30 percent of the patients who received standard CPR (P < 0.03); 45 percent of the patients who underwent active compression-decompression survived for at least 24 hours, as compared with 9 percent of patients who underwent standard CPR (P < 0.004). Two of the 62 study patients survived to hospital discharge; both were randomly assigned to receive active compression-decompression. Neurologic outcome, as measured by the Glasgow coma score, was better with active compression-decompression (8.0 +/- 1.3) than with standard CPR (3.5 +/- 0.3; P < 0.02). CONCLUSIONS: In this preliminary study, we found that, as compared with standard CPR, active compression-decompression CPR improved the rate of initial resuscitation, survival at 24 hours, and neurologic outcome after in-hospital cardiac arrest. Larger trials will be required to assess the potential benefit in terms of long-term survival.

Aged↗

A randomized, controlled trial of two-thumb vs two-finger chest compression in a swine infant model of cardiac arrest [see comment].

BACKGROUND: The American Heart Association (AHA) currently recommends two-finger (TF) chest compression for infants. A previous study demonstrated that two-thumb (TT) with lateral chest wall compression provided significantly higher arterial pressures than did the TF method. Limitations of that study included the lack of an asphyxial model and non-standardized compression forces. OBJECTIVE: To test the hypothesis that TT chest compression generates higher arterial pressures than does the TF method, using an asphyxial model. Also, by standardizing sternal compression force (SCF), the authors sought to show that the increased pressures are the result of thoracic compression. METHOD: The study was a randomized, crossover trial in immature swine weighing 10 kg. Each swine was sedated, anesthetized, paralyzed, intubated, and mechanically ventilated on room air. A femoral arterial catheter was placed. Cardiac arrest was induced by asphyxiation and verified by ECG and pressure tracings. Eleven AHA-certified basic rescuers each randomly performed four 1-minute trials of external chest compressions. Each of the two CPR techniques was performed, with and without feedback of SCF. Compression forces were measured using the Uniforce Sensor System (Force Imaging Technology, Inc., Chicago, IL). During the feedback mode, the rescuers were instructed to maintain sternal pressures at 20-25 psi. During the nonfeedback mode, the rescuers were blinded to the force transducer. All compressions were analyzed for systolic blood pressure (SBP), diastolic blood pressure (DBP), and SCF. Data were analyzed using repeated-measures analysis of variance (RMANOVA) and Tukey multiple comparisons (alpha = 0.05). RESULTS: A total of 2,297 compressions were analyzed. The TT method produced significantly higher SBPs both with (25% increase) and without (57% increase) feedback when compared with the TF. The DBPs were not significantly different. The SCFs were also significantly higher in the two groups with feedback. The SCFs in the TF groups did not reach the standardized value of 20 psi, whereas in the TT groups, both were in the range of 20-25 psi. CONCLUSION: The TT method produced significantly higher SBPs. The authors were unable to demonstrate that the increased SBPs were secondary to the thoracic compression component because the rescuers did not reach the predetermined SCF in the TF groups. In this swine model of infant CPR, TT chest compression is an easier and more effective method.

Animals↗

Bulk characterization of pharmaceutical powders by low-pressure compression.

Low-pressure compression of pharmaceutical powders using small amounts of sample (50 mg) was evaluated as an alternative to traditional bulk powder characterization by tapping volumetry. Material parameters were extrapolated directly from the compression data and by fitting with the Walker, the Kawakita, and the Log-Exp compression models. The compression-derived material parameters were compared to the poured and tapped density and the Compressibility Index determined by tapping. The repeatability of the compression-derived parameters was generally high, supporting their potential for characterization purposes. Significant correlation was demonstrated between several of the compression and tapping-derived parameters. The discriminative power of the low-pressure compression test was discussed using the compressed density at 0.2 MPa, correlated with the tapped density, and the relative Walker coefficient, correlated with the Compressibility Index, as examples. The compressed density at 0.2 MPa and the relative Walker coefficient demonstrated excellent discriminative power, superior to the discriminative power of the correlated tapping derived parameters. The low-pressure compression test was concluded to provide a cost-effective and sensitive alternative to traditional tapping volumetry.

Algorithms↗

Cardiorespiratory consequences of expiratory chest wall compression during mechanical ventilation and severe hyperinflation.

OBJECTIVES: To measure and compare the effects of manual expiratory compression of either the rib cage or abdomen on cardiac output, end-expiratory lung volume, and other cardiorespiratory variables in an animal model that mimics the severe pulmonary hyperinflation and hemodynamic impairment occurring in patients with severe acute asthma during mechanical ventilation. DESIGN: Prospective, randomized, crossover trial. SETTING: Research laboratory. SUBJECTS: Seven cross-bred, anesthetized, supine dogs. INTERVENTIONS: The following sequence was employed: a) spontaneous breathing without pulmonary hyperinflation; b) positive-pressure ventilation with severe pulmonary hyperinflation (produced by an external variable expiratory flow resistor); c) approximately 7 mins of manual expiratory compression of either the rib cage or abdomen during positive-pressure ventilation-hyperinflation. This sequence was then repeated, incorporating the alternative type of expiratory compression. MEASUREMENTS AND MAIN RESULTS: Cardiac output (measured by thermodilution), aortic pressure, pleural (esophageal) pressure, and changes in end-expiratory lung volume were measured. The decrease in cardiac output due to mechanical ventilation with pulmonary hyperinflation was exacerbated by rib cage compression (p < .001; spontaneous breathing 2.9 +/- 0.2 L/min, hyperinflation 1.5 +/- 0.1 L/min, and rib cage compression 1.0 +/- 0.1 [SEM] L/min). However, the positive-pressure ventilation-hyperinflation-induced decrease in cardiac output was attenuated by abdominal compression (p < .001; spontaneous breathing 3.3 +/- 0.2 L/min, hyperinflation 1.4 +/- 0.1 L/min, and abdominal compression 2.1 +/- 0.1 L/min). Mean aortic pressure returned to prehyperinflation levels during abdominal compression (p < .001; spontaneous breathing 126 +/- 2 mm Hg, hyperinflation 75 +/- 5 mm Hg, and abdominal compression 120 +/- 3 mm Hg). Both types of compression were similarly effective (p > .75) in increasing mean expiratory pleural pressure, so that end-expiratory lung volume was similarly (p > .25) reduced (0.45 +/- 0.05 and 0.40 +/- 0.05 L for rib cage and abdominal compressions, respectively) in this non-air flow, limiting animal model. CONCLUSIONS: The cardiorespiratory effects of manually compressing the rib cage or abdomen during expiration in this animal study suggest that these techniques should be carefully evaluated in mechanically ventilated patients with severe acute asthma.

Abdomen↗

Mechanical principles of compressive interbody fusion.

STUDY DESIGN: A biomechanical study on cadaveric lumbar spines was performed measuring interfragmentary forces and contact areas between intercorporal bone blocks and vertebral endplates. OBJECTIVES: To show the correct application of internal fixators to achieve interfragmentary compression between bone blocks and adjacent endplates. SUMMARY OF BACKGROUND DATA: Several researchers have previously tried to compress interbody bone blocks by internal fixator systems. Knowledge of the correct way to use the internal fixator systems for this purpose has been lacking. METHODS: Ten cadaveric lumbar spines were analyzed by instrumenting each motion unit with an intercorporal bone block and a dorsal transpedicular arbeitsgemeinschaft osteosynthesefragen internal fixator. Interfragmentary load and compression surface and their distribution were measured with a capacitive measuring mat. The internal fixator was loaded in compression in two different ways to determine the optimum mode of application. RESULTS: Simple compression of an internal fixator did not achieve sufficient interfragmentary forces and compression surfaces. Usually lordotic contouring of the instrumented spinal motion unit with a decrease in interfragmentary forces and width of compression surfaces developed. Preloading the fixator in slight kyphosis and compressing it in a second step achieved significantly improved interfragmentary forces and sufficient compression surfaces. CONCLUSIONS: Preloading an internal fixator in kyphosis and secondary compression is mandatory to get sufficient interfragmentary forces and compression surfaces between interbody bone blocks and adjacent vertebral endplates. The technique described provides a compressive interbody fusion and can be performed preserving the physiological shape of the spine.

Biomechanical Phenomena↗

Effects of rhythmic muscle compression on cardiovascular responses and muscle oxygenation at rest and during dynamic exercise.

We examined the way in which the duration of rhythmic muscle compressions affects cardiovascular responses and muscle oxygenation at rest and during dynamic exercise. We measured the mean arterial pressure (MAP), heart rate (HR) and oxygenation of the vastus lateralis muscle (by near-infrared spectroscopy) in eight healthy male subjects at rest and during supine bicycle exercise (50 and 100 W at 60 r.p.m.) while applying pulsed muscle compressions at 1000 ms intervals. Compression pressure and durations were 150 mmHg and 300, 600, 900 and 1000 ms (1000 ms being static continuous compression), respectively. During exercise, the pulsed leg compression was synchronized to each thigh extensor muscle contraction. The observed changes in muscle oxygenation were dependent on compression duration (increased at 300 ms, no change at 600 ms and decreased at 900 or 1000 ms) and were different from those seen at rest (increases at < 1000 ms and decrease at 1000 ms). This suggests that the effects of external pulsed muscle compression may have a duration threshold below which muscle pumping counteracts the obstruction to flow caused by the compression, and that the threshold is set at a shorter compression duration during exercise than at rest. Although HR and MAP did not change during pulsed compression at rest, during exercise they both increased progressively as compression duration increased. Thus, while exercising, the increased MAP and HR seen during the compression could be due to the combination and interaction of mechanical effects and the muscle mechanoreflex and/or metaboreflex.

Adult↗