PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Denture, Partial, Immediate”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17Linked to original sources

Human ex vivo bone tissue strains around immediately loaded implants supporting maxillary overdentures.

PURPOSE: To evaluate ex vivo bone tissue strains around maxillary implants supporting immediately loaded bar-retained overdentures. MATERIAL AND METHODS: Ninety degree two-element rosette strain gauges were bonded on the labial bone of four ITI dental implants placed in the maxillary anterior region of four completely edentulous maxilla of fresh human cadavers. The installation torque value (ITV) of each implant was measured by a custom-made torque wrench and resonance frequency analyses (RFAs) were undertaken. A bar-retained overdenture was fabricated for each cadaver, and two miniature load cells were integrated in the first molar region of the overdentures for controlled loading experiments. Strain measurements were performed at a sample rate of 10 kHz and under a maximum load of 100 N, simultaneously monitored from a computer connected to a data acquisition system. Finally, removal torque values (RTVs) of the implants were measured. RESULTS: RFA values did not mirror ITVs, while RTVs of implants were slightly lower than the ITVs. Any correlation could not be obtained between RFA values and ITVs or RTVs. Maximum strains around loaded implants ranged between -100 and -550 microepsilon under 25-100 N. The axial and lateral strain values of posterior implants of both sides were higher than those of anterior implants under all loads (P<0.05). CONCLUSION: Because occlusal forces in humans tend to decrease because of age-related factors, maximum strains around immediately loaded implants supporting maxillary overdentures fall within physiologic levels.

Aged↗

Histology of retrieved immediately and early loaded oxidized implants: light microscopic observations after 5 to 9 months of loading in the posterior mandible.

BACKGROUND: An increased number of publications report that one-stage surgery and immediate/early loading of dental implants may be a feasible approach for prosthetic reconstruction of the edentate patient. However, little is known about the histologic response to implants subjected to immediate/early loading in patients. PURPOSE: The aim of the present study was to histologically evaluate oxidized titanium implants subjected to loading immediately following surgery or after 2 months of healing and removed after 5 to 9 months loading. MATERIALS AND METHODS: Five patients participated in the study; each had consulted for implant treatment in the posterior mandible and subsequently volunteered to have extra implants inserted for the purpose of histologic research. Nine oxidized titanium implants (Brånemark System TiUnite , Nobel Biocare AB, Gothenburg, Sweden) were retrieved after 5 to 9 months in function. Two implants had been loaded the same day, whereas seven implants were loaded after 2 months of healing. Resonance frequency analysis was performed at retrieval on seven implants. Ground sections were prepared for histology and analyzed using light microscopic morphometry. RESULTS: Seven and 8.5 mm implants were placed, predominantly in quality 3 and 4 bone. Four implants were straight (Mk III), and five were tapered (Mk IV). All implants were clinically stable at retrieval and showed ISQ values of 65 to 79 with a mean of 71.4 +/- 4.4. Eight of the implants were able to be used for histology. A gross histologic examination showed an undisturbed healing of soft and bone tissues with no apparent differences between response to immediately and early loaded implants. Lamellar bone surrounded the implants, and remodeling was evident and more marked near the implant surface. A condensation of bone toward the implant surface was seen; this resulted in a lamina dura-like structure in trabecular bone. Thin rims of newly formed bone were often seen following the contour of the implant surface. The morphometric measurements showed a mean bone-to-implant contact value of 84.2 +/- 10.5% and a mean bone area value of 79.1 +/- 6.8%. The two immediately loaded implants showed bone-to-implant contact and bone area values of 92.9 +/- 0.1% and 84.9 +/- 0.9%, respectively. The corresponding values for the six early loaded implants were 81.4 +/- 10.6% and 77.1 +/- 6.8%, respectively. CONCLUSIONS: The present study demonstrated that oxidized implants subjected to immediate or early loading do integrate with soft and bone tissues in the posterior mandible.

Adult↗

Radiographic bone density around immediately loaded oral implants.

OBJECTIVES: The aim of this study was to analyze the bone density around immediately loaded oral implants by a new volumetric CT scan (Maxiscan) and to compare it with that of unloaded implants. MATERIAL AND METHODS: Four patients with an age range from 44 to 65 years old were selected for this study. All the patients needed a prosthetic rehabilitation in partially edentulous posterior maxillas or mandibles. A total of 12 oral implants were placed in the four patients. Six of these implants were immediately loaded while six were left unloaded. Six months after placement, immediately loaded and unloaded oral implants were analyzed by a volumetric CT scan. RESULTS: The overall success rate in this study with immediately loaded oral implants was 100%. The radiological assessments showed that the mean densitometric profile, which is a measure of bone mineralization, was higher in the immediately loaded group than in the unloaded group. The differences observed between the two groups of oral implants (immediately loaded and unloaded) were statistically significant (P<0.05). The bone was significantly more dense around immediately loaded than unloaded oral implants on the basis of a radiological assessment. CONCLUSION: The innovative aspect of this clinical study is to propose a new method to analyze the bone density, reducing the need for histological analysis from human biopsy.

Absorptiometry, Photon↗

Histologic analysis of an immediately loaded implant retrieved after 2 months.

Human biopsy of immediately loaded implants is the most important way to determine the occurrence of osseointegration. Implants inserted in sites with poor bone quality have been associated with lower success rates. The aim of this study is to document the early healing processes in a man around an immediately loaded implant retrieved after a 2-month loading period. An implant was inserted in the mandible of a 32-year-old patient and was loaded into a nonfunctional loading mode with a fixed provisional prosthesis the same day of the implant surgery. After 2 months, because the patient had difficulty accepting the implant, the implant was retrieved with a 5-mm trephine drill. Before retrieval, the implant appeared to be clinically osseointegrated, and no mobility was present. The preexisting bone quality was type D4. The implant was surrounded by newly formed bone lamellae with a width of 200 to 400 microm. In many areas it was possible to observe osteoblasts producing osteoid matrix directly on the implant surface. Bone-to-implant contact percentage was 71% +/- 3.2%. Even in a poor bone site and after a healing period of only 2 months, we observed a high bone-to-implant contact percentage. We can confirm that immediately loaded implants placed in soft spongy bone after a 2-month healing period can present mineralized tissue at the interface.

Adult↗

Immediate cantilevered resin-bonded bridgework: a case report.

Resin-bonded bridgework (RBB) is now an accepted alternative to conventional bridgework in specific cases. This article reviews the immediate replacement of two anterior teeth with the resin-bonded technique and describes the use of immediate cantilevered RBB in the aesthetic treatment of a patient with class II division II malocclusion on a moderate skeletal II base. Both maxillary lateral incisors were extracted and immediately replaced with cantilevered RBB. This simple and conservative approach produced an instant solution to a difficult aesthetic problem of proclined lateral incisors. The reported RBB continues to function successfully after 15 months.

Adult↗

Single-tooth implants in the maxillary incisor region with immediate provisionalization: 2-year prospective study.

Osseointegrated implants have been increasingly used for aesthetic, predictable restorative treatment. This study presents the 2-year postoperative results of patients treated with immediate, single, tapered implants in the maxillary incisor region and the simultaneous placement of provisional implant-supported crowns. Of the total of 92 implants placed, 6 were lost. Eighty-six implants were reevaluated and judged to have no signs of mobility, peri-implant inflammation, or adverse reactions. When used in selected cases, this technique facilitated maintenance of the gingival architecture adjacent to immediate transalveolar implants.

Crowns↗

Early loading of interforaminal implants immediately installed after extraction of teeth presenting endodontic and periodontal lesions.

BACKGROUND: Infection in tooth extraction sites has traditionally been considered an indication to postpone implant insertion until the infection has been resolved. PURPOSE: The aim of this study was to evaluate the survival rate of early-loaded implants placed immediately after extraction of teeth with endodontic and periodontal lesions in the mandible. MATERIALS AND METHODS: Twenty patients in need of mandibular implant treatment and with teeth showing signs of infection in the interforaminal area were included in the study. The patients received four to six implants (Brånemark System, Nobel Biocare AB, Göteborg, Sweden) in or close to the fresh extraction sockets and received a provisional prosthesis within 3 days. Final prostheses were delivered after 3 to 12 months. The surgical protocol paid special attention to the preservation of high implant stability and control of the inflammatory response. The patients were followed up for 15 to 44 months. RESULTS: No implants were lost, resulting in a 100% survival rate. A mean marginal bone loss of 0.7 mm (SD 1.2 mm) was registered during the observation period. No signs of infection around the implants were detected at any follow-up visit. CONCLUSION: A high survival rate can be achieved for immediately placed and early-loaded implants in the mandible despite the presence of infection at the extracted teeth.

Aged↗

Evaluation of two vitallium blade-form implants retrieved after 13 to 21 years of function: a clinical report.

This article describes the clinical, radiographic, and histologic evaluation of 2 immediately loaded Vitallium blade-form implants retrieved from the posterior maxilla of 2 patients after 21 and 13 years of function. Neither implant demonstrated mobility or signs of pathosis, and both appeared to have integrated well with surrounding bone. The hydroxyapatite coating of the second implant, which was retrieved after 13 years of function, showed no dissolution. These observations suggest that immediately loaded dental implants have the potential to achieve and maintain osseointegration and that hydroxyapatite coatings can resist degradation over long-term service.

Aged↗

"All-on-Four" immediate-function concept with Brånemark System implants for completely edentulous mandibles: a retrospective clinical study.

BACKGROUND: Immediate-function Brånemark System implants (Nobel Biocare AB, Gothenburg, Sweden) have become an accepted alternative for fixed restorations in edentulous mandibles, based on documented high success rates. Continuous development is ongoing to find simple protocols for their use. PURPOSE: The purpose of this study was to develop and document a simple, safe, and effective surgical and prosthetic protocol for immediate function (within 2 hours) of four Brånemark System implants supporting fixed prostheses in completely edentulous mandibles: the "All-on-Four" concept. MATERIALS AND METHODS: This retrospective clinical study included 44 patients with 176 immediately loaded implants, placed in the anterior region, supporting fixed complete-arch mandibular prostheses in acrylic. In addition to the immediately loaded implants, 24 of the 44 patients had 62 rescue implants not incorporated in the provisional prostheses but incorporated in final prostheses later on. RESULTS: Five immediately loaded implants were lost in five patients before the 6-month follow-up, giving cumulative survival rates of 96.7 and 98.2% for development and routine groups, respectively. The prostheses' survival was 100%, and the average bone resorption was low. CONCLUSIONS: The high cumulative implant and prostheses survival rates indicate that the "All-on-Four" immediate-function concept with Brånemark System implants used in completely edentulous mandibles is a viable concept.

Acrylic Resins↗

[The application of overdentures in the general dental practice].

Overdenture therapy is recommended in certain dental conditions. The main reason is that remaining teeth or roots underneath an overdenture decrease the resorption of the alveolar bone. There is little information about how acquainted general practitioners are with this therapy, how often they apply it and what potential obstacles to overdenture therapy they experience. Therefore, a postal investigation was made amongst dentists in the Netherlands. The data suggest that overdenture therapy is a well-known mode of treatment. Overdentures are applied in many dental practices but to a lesser degree than conventional immediate dentures. The negative attitude of the patients seems to be the most important obstacle to overdenture therapy. Therefore, the patient should be better informed about the advantages of this prosthetic appliance.

Alveolar Bone Loss↗

Immediate loading of Brånemark implants in edentulous mandibles: a preliminary report.

A study involving the immediate loading of Brånemark implants in the edentulous mandibles of 10 patients is reported. The design involved the immediate loading of four widely distributed implants with a transitional fixed implant-supported prosthesis at first-stage surgery, avoiding the need for a removable prosthesis. A sufficient number of additional implants are allowed to heal in the conventional manner to provide sufficient support for a definitive fixed prosthesis even if all of the immediately loaded implants fail. Preliminary results have been favorable, with all patients functioning with a fixed implant prosthesis from the day of first-stage surgery.

Aged↗

Immediate functional and non-functional loading of dental implants: a 2- to 60-month follow-up study of 646 titanium implants.

BACKGROUND: The aim of this study was the evaluation, from a clinical point of view, of implants subjected to immediate functional loading (IFL) and to immediate non-functional loading (INFL) in various anatomical configurations. METHODS: The study included 152 patients who had given their informed consent. A total of 646 implants were inserted. The implants were placed in 39 totally edentulous mandibles, 14 edentulous maxillae, 23 edentulous posterior mandibles, 16 edentulous anterior mandibles, 16 edentulous anterior maxillae, and 15 edentulous posterior maxillae. Fifty-eight implants were used to replace single missing teeth. In 65 cases, IFL was carried out for 422 implants. INFL was carried out in 116 cases, (224 implants). RESULTS: In the IFL group 6 of 422 implants failed (1.4%); in the INFL group 2 of 224 implants failed (0.9%). All the other implants appeared, from clinical and radiographic observations, to have successfully osseointegrated and have been functioning satisfactorily since insertion. All failures were observed in the first few months after implant loading. CONCLUSION: Immediate functional and non-functional loading seems to be a technique that gives satisfactory results in selected cases.

Adolescent↗

Early and immediately restored and loaded dental implants for single-tooth and partial-arch applications.

PURPOSE: The objective of this consensus committee report was to review the available literature published predominantly in refereed journals to summarize findings, data, and conclusions as they related to reduced healing times and protocols for single-tooth and partial-arch clinical situations. Early loading of dental implants has been defined as restoration of implants in or out of occlusion at least 48 hours after implant placement, but at a shorter time interval than conventional healing. Immediate loading or restoration has been defined as attachment of a restoration in or out of direct occlusal function within 48 hours of surgical placement. MATERIALS AND METHODS: Six articles addressing early loading, with a mixture of single-tooth and partial-arch clinical conditions and including some controlled cohort studies, were reviewed. Immediate loading or restoration of dental implants in single-tooth and partial-arch applications, was extensively reviewed. An attempt was made to isolate and categorize similar case types to discern trends and relevant factors. Variables that were considered included single- or multiple-tooth conditions, immediate or delayed placement in extraction sockets, effect of implant surface and geometry, bone quality, implant stability, surgical technique, occlusal design, effect of cigarette smoking, and stability of results. RESULTS: Combined data from 6 early loading studies on single-tooth and partial-arch applications revealed 1,046 implants with a survival rate of 98.2%. Long-term data for most of the early loading studies were not yet available. Most of the publications on immediate loading or restoration of dental implants were written as case series rather than scientific studies. DISCUSSION AND CONCLUSIONS: In general, most publications indicated that with attention to appropriate factors, implant survival with immediate restoration was comparable to the results with conventional and early loading protocols. It should be recognized that, with few exceptions, these conclusions may be misleading statistical phenomena of the authors, as most publications were written by exceptionally experienced, highly skilled practitioners working under tightly controlled clinical conditions on a relatively small, statistically inconclusive number of implants and patients.

Crowns↗

Immediate loading of two single tooth implants in the maxilla: preliminary results after one year.

This clinical report describes the traumatic avulsion of the left maxillary central and lateral incisors with minimal tissue trauma, followed by placement of provisional restorations of two root-form implants in a 14-year old female patient. Ten days following the avulsion, implant therapy was performed with Summers osteotomes and flapless technique using a root-form 3i osseotite NT. Angulated abutments and acrylic provisional crowns were placed. No occlusal contact was detected. An impression was made 30 days after implant insertion and ceramic restorations were placed 3 months later. No significant soft tissue contraction was observed during the provisional period. The patient exhibited no clinical or radiologic complications for 8 months after loading. In carefully selected under-aged patients implant therapy and immediate loading in the anterior maxilla for traumatic tooth avulsion may prove to be valuable to avoid soft tissue contraction, alveolar bone resorption, and positive esthetic/psychological response.

Accidents, Traffic↗

Delayed immediate implants: alveolar bone changes during the healing period.

Delaying the placement of immediate fixtures by 6-8 weeks after extraction of the natural dentition allows for the elimination of associated infective processes, the achievement of maximum osteoblastic activity that theoretically could help the osseointegration process and complete wound covering that simplifies the placement of grafts or membranes. This study examines the healing associated with 21 fixtures in 14 patients. The fixtures were placed into sockets 6-8 weeks after tooth extraction without the use of barrier membranes or bone substitutes. Measurements were taken immediately prior to fixture placement and 3-6 months later at the abutment placement. Alveolar bone height, the remaining socket depth and diameter and the depth to which a 3.75 mm fixture could be inserted into the socket were measured. After fixture placement the vertical and horizontal measurements from the cover screw to the surrounding alveolar bone and the distance from the cover screw to the CEJ of the adjacent tooth were recorded. All fixtures were integrated at exposure with 1 failure during the follow-up period. The distance from the cover screw to the buccal plate decreased by a mean of 2.17 mm. There was an increase in the mean vertical bone height at all 4 surfaces. When horizontal defects were present, the mean vertical distance decreased from 2.5 +/- 0.37 mm to 0.36 +/- 0.64 mm. When horizontal defects were absent, the mean vertical distance decreased from 3.86 +/- 0.58 mm to 0.48 +/- 0.25 mm. There was also a marked decrease in the horizontal distance between the bone margin and the surface of the fixture from 1.6 +/- 1.73 mm to 0.02 +/- 0.02 mm. These results indicate a strong tendency for the defects to fill-in the horizontal plane and for bone growth to occur in the vertical plane to the height of the cover screw. In conclusion the delayed immediate placement of fixtures has a good short-term prognosis with bone regeneration occurring around the defect without the use of barrier membranes or bone substitutes.

Adolescent↗

Immediate occlusal loading of single lower molars using Brånemark System Wide-Platform TiUnite implants: an interim report of a prospective open-ended clinical multicenter study.

BACKGROUND: First and second molars in the lower jaw are the most commonly missing teeth. As in other jaw regions with tooth loss, implant therapy is an attractive concept. Owing to the wide dimension of the molar teeth, wide implants seem to be a natural choice. However, wide implants in posterior mandibular regions sometimes present a problem. As an oxidized surface seems to facilitate implant integration and to result in a stronger fixation to bone, it was hypothesized that this surface would improve the performance of wide implants in posterior mandibles. As high initial stability most often is achieved in this region, it was hypothesized that the load per se is not a problem. PURPOSE: The purpose of the present study is to evaluate immediate loading of Brånemark System TiUnite Wide-Platform implants (Nobel Biocare AB, Gothenburg, Sweden) supporting single molar crowns in the lower jaw. MATERIALS AND METHODS: The study includes 44 patients treated in three separate private dental offices between March 2001 and June 2002. A total of 50 implants were placed, and all implants have passed the 6-month follow-up; 24 have been followed up for 1 year. All implants were provided with provisional crowns in centric occlusion at the time of surgery. RESULTS: No implant has been lost. Marginal bone levels were found in accordance with normal biologic width requirements. Resonance frequency analysis showed high and consistent implant stability. No biomechanical problems were found associated with the use of wide implants, and the potential physiologic problem in dense mandibular bone was eliminated. CONCLUSION: Although limited by being a short-term study, the result encourages immediate loading of single Brånemark System TiUnite Wide-Platform implants placed in the molar regions in the lower jaw.

Adult↗

Immediate implant-supported oral rehabilitation using a photocurable plastic skull model and laser welding. A technical note on the screw-retained type: Part 1.

PURPOSE: This article describes a new procedure for immediate implant-supported oral rehabilitation using a photocurable resin skull model and a laser-welding apparatus. MATERIALS AND METHODS: Preoperatively, the framework was fabricated on a photocurable resin skull model produced from a CT scan and individually designed guide template. The implants were immediately placed using the guide template; laser welding connected the components of framework. RESULTS: Despite the custom-made prosthesis, the total treatment from implant placement to superstructure placement can be completed within only 1 day. CONCLUSION: This procedure for immediate implant-supported oral rehabilitation using a photocurable resin skull model and a laser-welding apparatus may be useful for any implant system and patient.

Dental Articulators↗