A strain energy function for arteries accounting for wall composition and structure.

Identification of a Strain Energy Function (SEF) is used when describing the complex mechanical properties of soft biological tissues such as the arterial wall. Classic SEFs, such as the one proposed by Chuong and Fung (J. Biomech. Eng. 105(3) (1983) 268), have been mostly phenomenological and neglect the particularities of the wall structure. A more structural model was proposed by Holzapfel et al. (J. Elasticity 61 (2000) 1-48.) when they included the characteristic angle at which the collagen fibers are helically wrapped, resulting in an excellent SEF for applications such as finite element modeling. We have expanded upon the idea of structural SEFs by including not only the wavy nature of the collagen but also the fraction of both elastin and collagen contained in the media, which can be determined by histology. The waviness of the collagen is assumed to be distributed log-logistically. In order to evaluate this novel SEF, we have used it to fit experimental data from inflation-extension tests performed on rat carotids. We have compared the results of the fit to the SEFs of Choung and Fung and Holzapfel et al. The novel SEF is found to behave similarly to that of Holzapfel et al., both succeed in describing the typical S-shaped pressure-radius curves with comparable quality of fit. The parameters of the novel SEF obtained from the fitting, bearing the physical meaning of the elastic modulus of collagen, the elastic modulus of elastin, the collagen waviness, and the collagen fiber angle, were compared to experimental data and discussed.

Animals↗

Elastic energy storage in tendons: mechanical differences related to function and age.

We investigated the possibility that tendons that normally experience relatively high stresses and function as springs during locomotion, such as digital flexors, might develop different mechanical properties from those that experience only relatively low stresses, such as digital extensors. At birth the digital flexor and extensor tendons of pigs have identical mechanical properties, exhibiting higher extensibility and mechanical hysteresis and lower elastic modulus, tensile strength, and elastic energy storage capability than adult tendons. With growth and aging these tendons become much stronger, stiffer, less extensible, and more resilient than at birth. Furthermore, these alterations in elastic properties occur to a significantly greater degree in the high-load-bearing flexors than in the low-stress extensors. At maturity the pig digital flexor tendons have twice the tensile strength and elastic modulus but only half the strain energy dissipation of the corresponding extensor tendons. A morphometric analysis of the digital muscles provides an estimate of maximal in vivo tendon stresses and suggests that the muscle-tendon unit of the digital flexor is designed to function as an elastic energy storage element whereas that of the digital extensor is not. Thus the differences in material properties between mature flexor and extensor tendons are correlated with their physiological functions, i.e., the flexor is much better suited to act as an effective biological spring than is the extensor.

Age Factors↗

Effects of fibrinogen-binding tetrapeptides on mechanical properties of fine fibrin clots.

The tetrapeptides Gly-Pro-Arg-Pro and Gly-His-Arg-Pro, analogs of the amino termini of the alpha and beta chains of fibrin monomer, respectively, were introduced by diffusion into fine unligated fibrin clots. Gly-Pro-Arg-Pro decreased the shear modulus of elasticity progressively and at a concentration of 5.8 mM the clot was eventually liquefied. The decrease in elastic modulus was accompanied by enormously enhanced viscoelastic creep under shear stress and irrecoverable deformation after removal of stress. However, the differential compliance (or modulus) for clots containing the tetrapeptide remained constant during creep and creep recovery, so the structure rearranged under stress without any permanent damage. Ligation with factor XIIIa and calcium largely eliminated these effects. From these changes in mechanical properties, it appears that Gly-Pro-Arg-Pro competes for binding sites, with consequent depolymerization. The tetrapeptide Gly-His-Arg-Pro at comparable concentrations decreased the modulus and increased the creep to a lesser degree; when combined with Gly-Pro-Arg-Pro it enhanced the effectiveness of the latter.

Binding, Competitive↗

Experimental and numerical analyses of local mechanical properties measured by atomic force microscopy for sheared endothelial cells.

Local mechanical properties were measured for bovine endothelial cells exposed to shear stress using an atomic force microscopy (AFM), and the AFM indentations were simulated using a finite element method (FEM) to determine the elastic modulus. After exposure to shear stress, the endothelial cells showed marked elongation and orientation in the flow direction, together with significant decrease in the peak cell height. The applied force-indentation depth curve was obtained at seven different locations on the major axis of the cell surface and quantitatively expressed by the quadratic equation. The elastic modulus was determined by comparison of the experimental and numerical results. The modulus using our FEM model significantly became higher from 12.2+/-4.2 to 18.7+/-5.7 kPa with exposure to shear stress. Fluorescent images showed that stress fibers of F-actin bundles were mainly formed in the central portion of the sheared cells. The significant increase in the modulus may be due to this remodeling of cytoskeletal structure. The moduli using the Hertz model are 0.87+/-0.23 and 1.75+/-0.43 kPa for control and sheared endothelial cells respectively. This difference can be attributable to the differences in approximation functions to determine the elastic modulus. The elastic modulus would contribute a better understanding of local mechanical properties of the cells.

Animals↗

Relationship among MRTA, DXA, and QUS revisited.

Inexpensive, commercially produced devices that directly measure bone strength in vivo are not currently available. Mechanical response tissue analysis (MRTA), a unique prototype device, is an in vivo vibrational test that measures transverse bending stiffness (a measure of whole bone strength expressed as the product of estimated Young's modulus of elasticity and cross-sectional moment of inertia, EI, Nm2) at ulna midshaft. We compared speed of sound (SOS; [m/s]) in ulna cortical bone using a commercially available axial transmission quantitative ultrasound (QUS) device with EI using MRTA. Dual-energy X-ray absorptiometry (DXA) was used to provide an estimate of ulna size (cm2), bone mineral content (BMC; [g/cm]) and areal bone mineral density (BMD; [g/cm2]). The objective of the study was to determine if ulna SOS--alone or in combination with BMD from DXA--was correlated with ulna EI, thus becoming a surrogate measure of transverse bending stiffness, and thus whole bone strength. Data were collected from 138 female volunteers (18-86 yr). EI and SOS were significantly correlated, r = +0.218, p = 0.01, but r2 was very low, 4.8%. SOS and total ulna BMD were combined to estimate elastic modulus, which correlated with EI, r = +0.377, p < 0.0001; however, the correlation was not significantly better than with SOS alone. We conclude that axial transmission QUS is not a strong surrogate in vivo technique for estimating transverse bending stiffness.

Absorptiometry, Photon↗

Material optimisation of the femoral component of a hip prosthesis based on the fatigue notch fatigue approach.

Previous studies have optimised the shape of a cemented stainless steel stem in order to minimise the fatigue notch factor Kf in the cement whilst at the same time maximising Kt in the proximal medial bone to prevent bone resorption [1]. The present study firstly describes the effect of changes in the modulus of elasticity of the stem material for both the original Charnley stem and the optimised shape on Kf as predicted by a 2D finite element (FE) model of the implanted prosthesis. The paper further describes a method for parametric optimisation to determine the best material properties of a layered composite femoral stem consisting of a core material (stainless steel) and an outer layer of a different material, the elastic modulus of which is used as a design variable. The overall objective of the optimisation was to maximise Kf in the proximal bone whilst at the same time constraining Kf at all cement interfaces to be no greater than its initial value. The results of the first study suggest that Young's moduli of about 145 and 210 GPa are optimal for the monolithic Charnley and optimised stems, respectively. A composite prosthesis with a layer of modulus 31 GPa added to the optimised stainless steel stem in the proximal region only was found to significantly increase the stresses in the proximal bone and reduce Kf in the cement whilst retaining the advantages of an outer stem profile very similar to that of the original Charnley prosthesis.

Bone Cements↗

Predictors of clinical wear of restorative dental composite materials.

The mode-I plane-strain fracture toughness values of eight posterior restorative composite materials were determined using straight-sided chevron-notch short-rod specimens and a special loading module. These results, together with the values of the modulus of elasticity, modulus of resilience, and flexural strength of these materials (as given in a paper by a previous worker) were used in a detailed correlational exercise, with the values of the clinical wear of restorations made from these materials (as given in the aforementioned paper) being the dependent variable. It was found that clinical wear may best be predicted using values of all four aforementioned mechanical properties.

Bicuspid↗

Mechanical properties of BIS-GMA resin short glass fiber composites.

The use of short glass fibers as a filler for dental restorations or cement resins have not been examined extensively. The mechanical properties and untreated glass fibers (5 microns dia x 25 microns) in Bis-phenol A glycidyl methacrylate (BIS-GMA) diluted with triethylene-glycol dimethacrylate (TEGDMA) resin were investigated for possible use as a restorative dental composite or bone cement. Compression, uniaxial tension and fracture toughness tests were conducted for each filler composite mixtures of 40, 50, 60 and 70%. Set time and maximum temperature of polymerization were determined. The results show that the elastic modulus, tensile strength and compressive strength are dependent on the percent of filler content. Elastic modulus and compressive yield (0.2%) strength of silane treated glass fibers filled composite increased from 2.26 to 4.59 GPa and 43.3 to 66.6 MPa, respectively, wtih increasing the filler content while the tensile strength decreased from 26.7 to 18.6 MPa. The elastic modulus of the untreated composite was less than that of the silane treated fiber composite. The tensile strength and compressive strengths were 20 to 50% lower than those of silane treated composites. The fracture toughness of the silane treated glass fiber additions were not significantly different from the untreated additions. The highest fracture toughness was obtained at 50% filler content with 1.65 MPa m.5. Set time increased from 3.5 to 7.7 minutes with increased filler content and peak temperature dropped from 68.3 to 34 degrees C. The results of this study indicate that the addition of silane coated glass fiber to BIS-GMA resin increased the elastic modulus, tensile and compressive strengths compared with non-treated fibers. The addition of either treated or non-treated fibers increased the set time of the material and decreased the maximum temperature.

Bisphenol A-Glycidyl Methacrylate↗

Age dependence of mechanical parameters in rat skin following repeated strain.

The mechanical parameters of rat skin repeatedly strained with increasing elongation or repeatedly strained with a constant elongation was studied and the hysteresis behaviour was analyzed depending on age. Male Sprague Dawlely rats of an age of 1,2,4, 12, and 24 months were used. Ultimate strain of skin showed a maximum at early adulthood (2 months) whereas the other ultimate values (ultimate load, tensile strength and ultimate modulus of elasticity) exhibited their maxima in late adulthood (4 months). All these ultimate values increased due to maturation and decreased due to senescence. At medium extensions the stress uptake and the elasticity modulus showed a minimum in adulthood. Likewise, in hysteresis experiments both energy dissipation and energy loss at medium extensions exhibited a minimum in adulthood. The ratio between these two parameters, i.e. the relative energy loss was almost independent from age. Residual extension had a minimum at 2 months of age. Therefore, in rat skin the reversibility of deformations had a maximum at early adulthood, stiffness at late adulthood. All those parameters were reversed due to the senescence process.

Age Factors↗

A nonlinear mathematical model for the development and rupture of intracranial fusiform aneurysms.

Laplace's law, which describes a linear relation between the tension and the radius, is often used to characterize the mechanical response of the aneurysm wall to distending pressures. However, histopathological studies have confirmed that the wall of the fully developed aneurysm consists primarily of collagen and is subject to large increases in tension for small increases in the radius, i.e., a nonlinear relationship exists between the tension within the aneurysm wall and the radius. Thus, a nonlinear version of Laplace's law is proposed to accurately describe the development and rupture of a fusiform saccular aneurysm. The fusiform aneurysm was modelled as a thin-walled ellipsoidal shell with a major axis radius, Ra, minor axis radius, Rb, circumferential tension, S0, and meridional tension, S phi, with phi defining the angle from the surface normal. Using both linear and nonlinear models, differential expressions of the volume distensibility evaluated at 90 degrees were used to determine the critical radius of the aneurysm along the minor axis from S0 and S phi in terms of the following geometric and biophysical variables; A, elastic modulus of collagen; E, elastic modulus of the aneurysm (elastin and collagen); t, wall thickness; P, systolic pressure; and Ra. For typical physiological values of A = 2.8 MPa, E = 1.0 MPa, T = 40 microns, P = 150 mmHg, and Ra = 4Rb, the linear model yielded critical radii of 4.0 mm from S phi and 2.2 mm from S0. The resultant critical radius was 4.56 mm. Using the same values, the critical radii from the tension components of the nonlinear model were 3.5 mm from S phi and 1.9 mm from S0.(ABSTRACT TRUNCATED AT 250 WORDS)

Aneurysm, Ruptured↗

Properties of medium density fiberboards made from renewable biomass.

The goal of this study was to determine the comparative properties of dry-formed medium density fiberboards (MDF) made from renewable biomass (wheat and soybean straw) and those from conventional soft wood fiber. The MDF properties evaluated were modulus of elasticity, modulus of rupture, internal bond strength, thickness swell, and screw holding capacity. The results show that MDF made from wheat straw fiber and soy straw fiber have weaker mechanical and water resistance properties than those made from softwood fiber. Soybean straw is comparable to wheat straw in terms of both mechanical and water resistance properties to make MDF. Water resistance of MDF decreased drastically with increasing straw fiber composition. Wheat straw fiber and soybean straw fiber should be physically or chemically treated to increase their water resistance property for MDF production.

Adhesives↗

The suitability of packable resin-based composites for posterior restorations.

BACKGROUND: Packable composites, promoted for the restoration of stress-bearing posterior teeth, have captured clinicians' interest. METHODS: The authors tested three packable composites (Alert, Jeneric/Pentron; Solitaire, Heraeus Kulzer, Wehrheim, Germany; SureFil, Dentsply De Trey, Konstanz, Germany); a new packable organically modified ceramic, or ormocer (Definite, Degussa AG, Hanau, Germany); a hybrid composite (Tetric Ceram, Ivoclar Vivadent, Schaan, Liechtenstein) and an ion-releasing composite (Ariston pHc, Ivoclar Vivadent, Schaan, Liechtenstein). They determined modulus of elasticity according to EN 24049:1993 of the European Committee for Standardization. They measured Vickers hardness using a 200-gram load for 40 seconds. To determine the materials' depth of cure, they used both a scraping method (International Standards Organization standard CD 4049:1997) and a hardness profiling method. RESULTS: The authors calculated means and standard deviations from 10 replications of each test and used one-way analysis of variance and post hoc Tukey tests (alpha = .05). The materials had significant differences (P < .001) in all characteristics. Solitaire had the significantly lowest elastic modulus and microhardness; Alert had the highest values for these characteristics. Ariston pHc exhibited the significantly lowest depth of cure. There was a significant correlation between the two methods of measuring depth of cure (r2 = 0.9945; P = .021). CONCLUSIONS: The material group of packable composites is rather inhomogeneous in terms of mechanical and physical data. Our data suggest that bulk curing of packable composites in deep cavities still is not recommendable. CLINICAL IMPLICATIONS: The clinician needs to select packable composites carefully, as it seems that not all of these materials quality for stress-loaded posterior restorations.

Analysis of Variance↗

Mechanical deterioration underlies malignant behavior of aneurysmal human ascending aorta.

OBJECTIVE: The human ascending aorta becomes markedly prone to rupture and dissection at a diameter of 6 cm. The mechanical substrate for this malignant behavior is unknown. This investigation applied engineering analysis to human ascending aortic aneurysms and compared their structural characteristics with those of normal aortas. METHODS: We measured the mechanical characteristics of the aorta by direct epiaortic echocardiography at the time of surgery in 33 patients with ascending aortic aneurysm undergoing aortic replacement and in 20 control patients with normal aortas undergoing coronary artery bypass grafting. Six parameters were measured in all patients: aortic diameter in systole and diastole, aortic wall thickness in systole and diastole, and blood pressure in systole and diastole. These were used to calculate mechanical characteristics of the aorta from standard equations. Aortic distensibility reflects the elastic qualities of the aorta. Aortic wall stress reflects the disrupting force experienced within the aortic wall. Incremental elastic modulus indicates loss of elasticity reserve. RESULTS: Aortic distensibility falls to extremely low levels as aortic dimension rises toward 6 cm (3.02 mm Hg(-1) for small aortas versus 1.45 mm Hg(-1) for aortas larger than 5 cm, P < .05). Aortic wall stress rises to 157.8 kPa for the aneurysmal aorta, compared with 92.5 kPa for normal aortas. For 6-cm aortas at pressures of 200 mm Hg or more, wall stress rises to 857 kPa, nearly exceeding the known maximal tensile strength of human aneurysmal aortic wall. Incremental elastic modulus deteriorates (1.93 +/- 0.88 MPa vs 1.18 +/- 0.21 MPa, P < .05) in aneurysmal aortas relative to that in normal aortas. CONCLUSION: The mechanical properties of the aneurysmal aorta deteriorate dramatically as the aorta enlarges, reaching critical levels associated with rupture by a diameter of 6 cm. This mechanical deterioration provides an explanation in engineering terms for the malignant clinical behavior (rupture and dissection) of the aorta at these dimensions. This work adds to our fundamental understanding of the biology of aortic aneurysms and promises to permit future application of engineering measurements to supplement aneurysm size in clinical decision making in aneurysmal disease.

Aorta↗

Leaching and mechanical properties characterization of dental composites.

The objective of this study was to determine the leaching of Ba, Si, and Sr from four dental composites: Restolux (RX), Micronew (M), Renew (RW), and Choice (C) and to correlate the effects of such leaching with flexure strength and modulus of elasticity. The specimens were 3 x 3 x 25-mm bars, polished with 120- and 240-grit SiC paper, and were aged for 4, 6, and 8 months in artificial saliva, distilled water, and a 50/50 mixture of ethanol and distilled water. Inductively coupled plasma with mass spectroscopy (ICP/MS) was used to determine the ion concentrations after aging. The greatest release of Ba and Sr occurred after aging in 50/50 volume fraction mixture of ethanol/water and for Si in artificial saliva. The 50/50 solution caused a breakdown of the resin and glass matrix, resulting in an increase of Ba and Sr, whereas aging in artificial saliva resulted in an ion charge balance, which allowed an elevated and continuous release of Si. The flexure strength and the elastic modulus showed a gradual decrease over time, with the greatest decreases occurring following aging in the 50/50 water/ethanol solution, but little correlation with the leaching of the filler ions.

Biocompatible Materials↗

Hydrothermal and mechanical stresses degrade fiber-matrix interfacial bond strength in dental fiber-reinforced composites.

Fiber-reinforced composites (FRCs) show great promise as long-term restorative materials in dentistry and medicine. Recent evidence indicates that these materials degrade in vivo, but the mechanisms are unclear. The objective of this study was to investigate mechanisms of deterioration of glass fiber-polymer matrix bond strengths in dental fiber-reinforced composites during hydrothermal and mechanical aging. Conventional three-point bending tests on dental FRCs were used to assess flexural strengths and moduli. Micro push-out tests were used to measure glass fiber-polymer matrix bond strengths, and nanoindentation tests were used to determine the modulus of elasticity of fiber and polymer matrix phases separately. Bar-shaped specimens of FRCs (EverStick, StickTech, and Vectris Pontic, Ivoclar-Vivadent) were either stored at room temperature, in water (37 and 100 degrees C) or subjected to ageing (10(6) cycles, load: 49 N), then tested by three-point bending. Thin slices were prepared for micro push-out and nanoindentation tests. The ultimate flexural strengths of both FRCs were significantly reduced after aging (p < 0.05). Both water storage and mechanical loading reduced the interfacial bond strengths of glass fibers to polymer matrices. Nanoindentation tests revealed a slight reduction in the elastic modulus of the EverStick and Vectris Pontic polymer matrix after water storage. Mechanical properties of FRC materials degrade primarily by a loss of interfacial bond strength between the glass and resin phases. This degradation is detectable by micro push-out and nanoindentation methods.

Biomechanical Phenomena↗

Water, solute, and segmental dynamics in polysaccharide hydrogels.

Polysaccharide hydrogels have found several applications in the food industry, in biomedicine, and cosmetics. The study of polysaccharide hydrogels offers a challenging scenario of intrinsic heterogeneities in the crosslinking density and large time and space ranges that characterize a number of dynamic processes entailing segmental motions, water diffusion, and small-molecule diffusion. The understanding of such complex features is essential because of the extensive use of polysaccharidic moieties in the food industry, biomedical devices, and cosmetics. The study of phenomena occurring at the nanoscale to the mesoscale requires the combination of investigative tools to probe different time and distance scales and the structural characterization of the networks by established methodologies such as swelling and elastic modulus measurements. Elastic and quasielastic neutron scattering, and fluorescence recovery after photobleaching are emerging methodologies in this field. In this feature article we focus, somewhat arbitrarily, on these new approaches because other techniques, such as low-resolution proton NMR relaxometry and rheology, have been already described thoroughly in the literature. Case examples of polysaccharide hydrogels studied by neutron scattering and fluorescence recovery are presented here as contributions to the comprehension of the dynamic behavior of physical and chemical hydrogels based on polysaccharides. Quasielastic incoherent neutron scattering experiment on a Sephadex hydrogel sample at different temperatures.

Elasticity↗

The effect of fluoride on bone of rats fed diets deficient in calcium or phosphorus.

Four groups of weanling rats were fed for 2 weeks on a diet sufficient or insufficient in calcium and/or phosphorus. Each group was divided into four subgroups which were offered distilled water supplemented with 0, 50, 75, or 150 ppm fluoride. High levels of fluoride in drinking water inhibited weight gain. This inhibition was less in rats deficient in phosphorus than when normal-phosphorus diets were offered. At a low level, fluoride was without any effect on bone ash, thickness of femoral cortical bone, and mechanical strength, as measured by maximal load, ultimate stress to breaking, and limit of elasticity. Modulus of elasticity was decreased. At higher levels fluoride tended to decrease most of these parameters, except in rats deprived of both calcium and phosphorus. The effect of fluoride was modified by lack of dietary calcium and/or phosphorus and appeared to be weaker in rats deficient in these nutrients. Lack of dietary calcium and/or phosphorus decreased bone strength more than did fluoride content of water and of bone mineral. Concentration of bone ash and thickness of femoral cortical bone were closely correlated with parameters of mechanical strength.

Animals↗

Biomechanics of the venous wall under simulated arterial conditions.

The failure of vein graft conduits implanted in the arterial circulation has been hypothesized to occur in part due to the exposure of the graft to altered biomechanical and fluid shearing forces. In the present study, these forces are characterized for canine internal jugular veins (IJV) exposed to realistic arterial flow dynamics. Freshly excised vein segments were mounted into a pulsatile perfusion apparatus and exposed to arterial flow conditions (P = 115/75 mmHg and Q = 110 ml min-1) for 2 h. Dynamic measurements of intraluminal pressure and flow rate and vessel wall radial distension were acquired to accurately quantitate the incremental modulus of elasticity; hoop, axial and radial wall stresses; and fluid shearing forces within the vessel. Identical measurements were performed on canine carotid arteries (CCA) to serve as a comparison. Under arterial conditions, IJV segments demonstrated a significant elevation (p less than 0.05) over the CCA in the incremental elasticity modulus, along with a corresponding elevation in hoop and axial wall stresses. Additionally the average wall shearing rate to which the IJV endothelial surface was exposed was a factor of six less than that observed in the CCA. These results are discussed in relationship to the clinical situation of vein graft adaptation to arterial hemodynamics.