PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Fluorescence imaging”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17Linked to original sources

Real-time multi-wavelength fluorescence imaging of living cells.

We describe a new real-time fluorescence video microscope design for capturing intensified images of cells containing dual wavelength "ratio" dyes or multiple dyes. The microscope will perform real-time capture of two separate fluorescence emission images simultaneously, improving the time resolution of spatial distribution of fluorescence to video frame rates (30 frames/s or faster). Each emission wavelength is imaged simultaneously by one of two cameras, then digitized, background corrected and appropriately combined at standard video frame rates to be stored at high resolution on tape or digital video disk for further off-line analysis. Use of low noise, high sensitivity image intensifiers, coupled to CCD cameras produce stable, high contrast images using ultra low light levels with little persistence or bloom. The design has no moving parts in its optical train, which overcomes a number of technical difficulties encountered in the present filter wheel designs for multiple imaging. Coupled to compatible image processing software utilizing PC-AT computers, the new design can be built for a significantly lower cost than many presently available commercial machines. The system is ideal for ratio imaging applications; the software can calculate the ratio of fluorescence intensities pixel by pixel and provide the information to generate false-color images of the intensity data as well as other calculations based on the two images. Thus, it provides a powerful, inexpensive tool for studying the real-time kinetics of changes in living cells. Examples are presented for the kinetics of rapidly changing intracellular calcium detected by the calcium indicator probe indo-1 and the redistribution kinetics of multiple vital dyes placed in cells undergoing cell fusion.

Animals↗

A digitized fluorescence imaging study on the effects of local anesthetics on cytosolic calcium and mitochondrial membrane potential in cultured rabbit corneal epithelial cells.

It has been documented by several investigators that local anesthetics displace calcium from calcium binding sites and alter the functioning of different calcium regulating systems. Local anesthetics have also been shown to have adverse effects on mitochondrial function and interact with cytoskeletal elements. Few studies have addressed the role that a potential disturbance of calcium homeostasis and mitochondrial function may have on the toxicity caused by local anesthetics in corneal epithelial cells. This investigation was undertaken to evaluate the effects of tetracaine (TTC), proparacaine (PPC), and cocaine (CC) on cytosolic calcium and mitochondrial membrane potential in primary cultures of rabbit corneal epithelial cells. Previous studies by our laboratory documented that the local anesthetics produce toxicity after 30 to 60 min of treatment. In this study, the cells were treated for 15 min, a time when minimal cell damage occurred. The following concentrations of local anesthetics were used to treat the cells: TTC, 0.5-2.5 mM; PPC, 1-5 mM; and CC, 4-10 mM. We utilized the technology of digitized fluorescence imaging to measure changes in intracellular calcium ([Ca2+]i) with fura-2 and mitochondrial membrane potential (delta psi) with rhodamine 123. A dose-dependent increase in [Ca2+]i was evident after treatment with each local anesthetic. Concentrations equal or greater than 2.5 mM TTC dissipated delta psi. A rise in [Ca2+]i preceded any loss of delta psi caused by TTC. PPC at high concentrations (4-5 mM) occasionally dissipated delta psi but this was not a consistent finding. The effects of CC on delta psi could not be evaluated accurately because of the extensive morphological alterations that occurred after treatment. We conclude that TTC, PPC, and CC elevate [Ca2+]i before cytotoxicity occurs and disruptions in calcium homeostasis may contribute to their toxicity.

Anesthetics, Local↗

Direct modulation of the effective sensitivity of a CCD detector: a new approach to time-resolved fluorescence imaging.

In this paper a novel approach to frequency-domain fluorescence lifetime imaging (FLIM) is described. In a CCD camera a single pixel is defined by a charge pattern on a group of electrodes. By modulation of the pattern of voltages defining the pixel structure it is possible to modulate the sensitivity of the CCD at radio frequency. The modulation enhances the noise performance of the CCD, in contrast to the deterioration in performance seen when an intensifier stage is similarly modulated. The new technology has potential applications to a wide range of assays as well as in conventional FLIM applications. Unlike intensifier-based systems, the directly modulated CCD is physically small, inexpensive, robust and offers superior resolution and noise performance.

Journal Article↗

IRDye78 conjugates for near-infrared fluorescence imaging.

The detection of human malignancies by near-infrared (NIR) fluorescence will require the conjugation of cancer-specific ligands to NIR fluorophores that have optimal photoproperties and pharmacokinetics. IRDye78, a tetra-sulfonated heptamethine indocyanine NIR fluorophore, meets most of the criteria for an in vivo imaging agent, and is available as an N-hydroxysuccinimide ester for conjugation to low-molecular-weight ligands. However, IRDye78 has a high charge-to-mass ratio, complicating purification of conjugates. It also has a potentially labile linkage between fluorophore and ligand. We have developed an ion-pairing purification strategy for IRDye78 that can be performed with a standard C18 column under neutral conditions, thus preserving the stability of fluorophore, ligand, and conjugate. By employing parallel evaporative light scatter and absorbance detectors, all reactants and products are identified, and conjugate purity is maximized. We describe reversible and irreversible conversions of IRDye78 that can occur during sample purification, and describe methods for preserving conjugate stability. Using seven ligands, spanning several classes of small molecules and peptides (neutral, charged, and/or hydrophobic), we illustrate the robustness of these methods, and confirm that IRDye78 conjugates so purified retain bioactivity and permit NIR fluorescence imaging of specific targets.

Animals↗

Site-specific confocal fluorescence imaging of biological microstructures in a turbid medium.

Normally transparent biological structures in a turbid medium are imaged using a laser confocal microscope and multiwavelength site-specific fluorescence labelling. The spatial filtering capability of the detector pinhole in the confocal microscope limits the number of scattered fluorescent photons that reach the photodetector. Simultaneous application of different fluorescent markers on the same sample site minimizes photobleaching by reducing the excitation time for each marker. A high-contrast grey-level image is also produced by summing confocal images of the same site taken at different fluorescence wavelengths. Monte Carlo simulations are performed to obtain the quantitative behaviour of confocal fluorescence imaging in turbid media. Confocal images of the following samples were also obtained: (i) 15 microm diameter fluorescent spheres placed 1.16 mm deep beneath an aqueous suspension of 0.0823 microm diameter polystyrene latex spheres, and (ii) hindbrain of a whole-mount mouse embryo (age 10 days) that was stained to fluoresce at 515 nm and 580 nm peak wavelengths. Expression of RNA transcripts of a gene within the embryo hindbrain was detected by a fluorescence-based whole-mount in situ hybridization procedure that we recently tested.

Animals↗

Automated fluorescence image cytometry. DNA quantification and detection of chlamydial infections.

Digitized fluorescence microscopy in conjunction with automated image segmentation is a promising approach for screening clinical specimens quickly and reliably. This paper describes the hardware and software of a prototype image-based cytometer that can identify fluorescent objects, discriminate true objects from artifacts and divide overlapping pairs of objects. The use of this image cytometer is discussed for: (1) the measurement of the DNA ploidy distribution of isolated mature rat liver nuclei labeled with 4',6-diamidine-2-phenylindole; (2) the comparison of the DNA ploidy distributions of the same samples measured by image cytometry (ICM) and flow cytometry (FCM); and (3) the quantification of chlamydial infection by double labeling cells with antichlamydiae antibody and Hoechst 33258 for nuclear DNA analysis. Ploidy distributions measured by the automated image cytometer compared favorably to those obtained by FCM. All pairs of overlapping nuclei were automatically detected by an additional computer algorithm, and those pairs that were clearly more than one nucleus by visual inspection were correctly divided. The irregular morphology of the chlamydiae-infected cells meant that 26% of them were not correctly identified in the fluorescein-stained images (as judged by manual inspection), but all cells were nevertheless detected correctly from the images of the Hoechst-stained samples. Automated fluorescence ICM yielded results similar to those obtained with FCM and had the additional benefit of maintaining cell and tissue architecture while preserving the opportunity for subsequent manual inspection of the specimen.

Algorithms↗

Fluorescent imaging and analysis with Typhoon 8600.

Current technologies in laser-based imaging systems for life science applications offer highly sensitive and quantitative detection of multiple labels. Typhoon 8600 variable mode imager is capable of fluorescence, storage phosphor, and chemiluminescence detection of gels and blots. The system delivers sensitive fluorescent detection of nucleic acids and proteins in both agarose and polyacrylamide gel formats. Detection and discrimination of multicolor fluorescent signals in fragment analysis, electromobility shift assays, Western blotting and other applications enhance the speed and accuracy of analysis.

DNA↗

Single molecule fluorescence imaging of the photoinduced conversion and bleaching behavior of the fluorescent protein Kaede.

Photoconversion and photobleaching behavior of the fluorescent protein Kaede immobilized in polyacrylamide gel matrix at room temperature was studied by single molecule wide-field fluorescence microscopy. Photobleaching kinetics of Kaede molecules upon excitation at 488 nm showed slight heterogeneity, suggesting the presence of different protein conformations and/or the distribution of local environments in the gel matrix. Statistical analysis of intensity trajectories of single molecules revealed four major types of fluorescence dynamics behavior upon short illumination by a violet light pulse (405 nm). In particular, two types of photoswitching behavior were observed: the green-to-red photoconversion (4% of Kaede molecules) and the photoactivation of green fluorescence without emission of red fluorescence (13%). Two other major groups show neither photoconversion nor red emission and demonstrate photoinduced partial deactivation (43%) and partial revival (30%) of green fluorescence. The significantly lower green-to-red conversion ratio as compared with bulk measurements in aqueous solution might be induced by the immobilization of the protein molecules within a polyacrylamide gel. Contrary to Ando et al. (Proc Natl Acad Sci 2002;99:12651-12656), we found a significant increase in green fluorescence emission upon illumination with 405-nm light, which is typical for GFP and related proteins.

Animals↗

Compact multiphoton/single photon laser scanning microscope for spectral imaging and fluorescence lifetime imaging.

An inverted fluorescence microscope was upgraded into a compact three-dimensional laser scanning microscope (LSM) of 65 x 62 x 48 cm dimensions by means of a fast kHz galvoscanner unit, a piezodriven z-stage, and a picosecond (ps) 50 MHz laser diode at 405 nm. In addition, compact turn-key near infrared femtosecond lasers have been employed to perform multiphoton fluorescence and second harmonic generation (SHG) microscopy. To expand the features of the compact LSM, a time-correlated single photon counting unit as well as a Sagnac interferometer have been added to realize fluorescence lifetime imaging (FLIM) and spectral imaging. Using this unique five-dimensional microscope, TauMap, single-photon excited (SPE), and two-photon excited (TPE) cellular fluorescence as well as intratissue autofluorescence of water plant leaves have been investigated with submicron spatial resolution, <270 ps temporal resolution, and 10 nm spectral resolution.

Animals↗

Multispectral imaging fluorescence microscopy for living cells.

Multispectral imaging technologies have been widely used in fields of astronomy and remote sensing. Interdisciplinary approaches developed in, for example, the National Aeronautics and Space Administration (NASA, USA), the Jet Propulsion Laboratory (JPL, USA), or the Communications Research Laboratory (CRL, Japan) have extended the application areas of these technologies from planetary systems to cellular systems. Here we overview multispectral imaging systems that have been devised for microscope applications. We introduce these systems with particular interest in live cell imaging. Finally we demonstrate examples of spectral imaging of living cells using commercially available systems with no need for user engineering.

Animals↗

Comparison of nanosecond and picosecond excitation for two-photon laser-induced fluorescence imaging of atomic oxygen in flames.

Two-photon laser-induced fluorescence (LIF) imaging of atomic oxygen is investigated in premixed hydrogen and methane flames with nanosecond and picosecond pulsed lasers at 226 nm. In the hydrogen flame, the interference from photolysis is negligible compared with the LIF signal from native atomic oxygen, and the major limitations on quantitative measurements are stimulated emission and photoionization. Excitation with a nanosecond laser is advantageous in the hydrogen flames, because it reduces the effects of stimulated emission and photoionization. In the methane flames, however, photolytic interference is the major complication for quantitative O-atom measurements. A comparison of methane and hydrogen flames indicates that vibrationally excited CO2 is the dominant precursor for laser-generated atomic oxygen. In the methane flames, picosecond excitation offers a significant advantage by dramatically reducing the photolytic interference. The prospects for improved O-atom imaging in hydrogen and hydrocarbon flames are presented.

Journal Article↗

Advances in fluorescence imaging with quantum dot bio-probes.

After much effort in surface chemistry development and optimization by several groups, fluorescent semiconductor nanocrystals probes, also known as quantum dots or qdots, are now entering the realm of biological applications with much to offer to biologists. The road to success has been paved with hurdles but from these efforts has stemmed a multitude of original surface chemistries that scientists in the biological fields can draw from for their specific biological applications. The ability to easily modulate the chemical nature of qdot surfaces by employing one or more of the recently developed qdot coatings, together with their exceptional photophysics have been key elements for qdots to acquire a status of revolutionary fluorescent bio-probes. Indeed, the unique properties of qdots not only give biologists the opportunity to explore advanced imaging techniques such as single molecule or lifetime imaging but also to revisit traditional fluorescence imaging methodologies and extract yet unobserved or inaccessible information in vitro or in vivo.

Chromogenic Compounds↗

Single-cell measurement of superoxide anion and hydrogen peroxide production by human neutrophils with digital imaging fluorescence microscopy.

Besides flow cytometry, fluorescence microscopy combined with computerized image analysis offers an alternative tool for assessing phagocyte oxidant generation at the single-cell level. This technique provides an opportunity for the direct visualization of cells and simultaneous measurement of cellular fluorescence intensity. Thus, we developed a simple method for the quantitative evaluation of intracellular superoxide anion and hydrogen peroxide production with image cytometry by using hydroethidine and dihydrorhodamine 123 dyes, respectively. Human neutrophils stimulated with phorbol dibutyrate and labeled by these fluorogenic substrates showed intense, well recognizable red or green fluorescence. The intensity of signals from individual granulocytes of cytospin preparations were quantitatively measured in digitized images. There was a great heterogeneity in response to the stimulus within the granulocyte population as shown by the integrated fluorescence intensity values. In agreement with the results of parallel flow cytometric experiments, this simple image analysis performed on cells of cytospin preparations was able to detect the defects in the oxidative metabolism of neutrophils from patients with cervix carcinoma. We demonstrated that even minor alterations in superoxide anion/hydrogen peroxide generation can be detected by image cytometry as efficiently as by flow cytometry. This result validates imaging microscopy as an alternative to flow cytometry in such experiments. In addition, the image cytometric technique allows the observation of the kinetics of free radical production in individual cell under adherent conditions. Therefore, we carried out image analysis of the oxidative burst of neutrophils adherent to uncoated glass and fibronectin- and type IV collagen-coated surfaces in response to stimulation with phorbol dibutyrate or N-formyl-methionyl-leucyl-phenylalanine. We elaborated a calibration technique for the quantitative measurement of the ethidium bromide generation mediated by superoxide anion within individual adherent granulocytes. The ethidium bromide production varied between 0.48 and 1.17 amol/cell/min.

Anions↗

Fluorescence imaging of local membrane electric fields during the excitation of single neurons in culture.

The spatial distribution of depolarized patches of membrane during the excitation of single neurons in culture has been recorded with a high spatial resolution (1 micron2/pixel) imaging system based on a liquid-nitrogen-cooled astronomical camera mounted on an inverted microscope. Images were captured from rat nodose neurons stained with the voltage-sensitive dye RH237. Conventional intracellular microelectrode recordings were made in synchrony with the images. During an action potential the fluorescence changes occurred in localized, unevenly distributed membrane areas, which formed clusters of depolarized sites of different sizes and intensities. When fast conductances were blocked by the addition of tetrodotoxin, a reduction in the number and the intensities of the depolarized sites was observed. The blockade by tetrodotoxin of voltage-clamped neurons also reduced the number of depolarized sites, although the same depolarizing voltage step was applied. Similarly, when a voltage-clamped neuron was depolarized by a constant-amplitude voltage step, the number of depolarized sites varied according to the degree of activation of the voltage-sensitive channels, which was modified by changing the holding potential. These results suggest that the spatial patterns of depolarization observed during excitation are related to the operations of ionic channels in the membrane.

Action Potentials↗

Fluorescence imaging and point measurements of tissue: applications to the demarcation of malignant tumors and atherosclerotic lesions from normal tissue.

The possibilities of using laser-induced fluorescence for tissue diagnostics are discussed. The tissue types investigated are malignant tumors and atherosclerotic lesions. Studies with natural autofluorescence as well as with fluorescent tumor markers are included in this paper. Fluorescence emission and decay data are presented for some tissue chromophores contributing to tissue autofluorescence. Optical spectroscopic characteristics of fluorescent malignant tumor markers are analyzed and instrumental designs for clinical applications are discussed. Images recorded with a multicolor fluorescence imaging system developed in Lund are presented.

Adenocarcinoma↗

Digital fluorescence imaging of elementary steps of neurosteroid synthesis in rat brain glial cells.

With fluorescence microscopic imaging, we have examined Ca2+ signaling, LDL uptake and distribution of cytochrome P450 scc on individual rat brain glial cells in order to investigate the molecular mechanisms of neurosteroid synthesis. Astrocytes and oligodendrocytes were cultured from newborn rat brain. Ca2+ signaling was observed in Calcium Green-1 loaded astrocytes upon neurotransmitter stimulations using video-enhanced microscopy. Upon stimulation of serotonin and glutamate, we observed typically three types of Ca2+ signaling which were Ca2+ oscillations, a transient increase in Ca2+ concentration and Ca2+ oscillations superimposed on a transient Ca2+ increase. On the other hand, histamine and ATP induced only a transient increase in Ca2+ without oscillatory response. Uptake of octadecyl rhodamine (R18) labeled LDL by astrocytes and oligodendrocytes was observed in the time scale of 30 min with confocal laser scanning microscopy. Some localization of LDL in the cytoplasm was observed for astrocytes. For oligodendrocytes, incorporated LDL was distributed over the entire cytoplasmic region of both cell body and multiple branched cell processes. The presence of a significant amount of cytochrome P450 scc was demonstrated with immunofluorescence staining in both astrocytes and oligodendrocytes. The density of P450 scc in both glial cells was suggested to be around 1% of that in bovine adrenocortical fasciculata cells. The results lead to an improved quantitative picture of neurosteroid synthesis in glial cells.

Adrenal Cortex↗

In vivo laser-induced fluorescence imaging of a rat pancreatic cancer with pheophorbide-a.

Laser-induced fluorescence (LIF) of pheophorbide-a (Ph-a) was used for imaging of a rat pancreatic tumor. Using a dimensionless function (the ratio of Ph-a fluorescence by bluish autofluorescence), the fluorescence contrasts between excised tumors and their paired pancreas were investigated up to 48 h after a 9 mg kg-1 Ph-a intravenous administration. Among five tested excitation wavelengths, 355 and 610 nm excitations gave the best distinctive contrasts, both 48 h after dye injection. The LIF imaging of six intrapancreatic tumors and six healthy pancreas was carried out in vivo using two laser excitations: 355 nm (Nd:YAG + tripling) for bluish autofluorescence and 610 nm (rhodamine 6G dye) for reddish autofluorescence and dye emission. Images were recorded through bandpass filters at 470 and 640 nm (autofluorescence) and at 680 nm (dye + autofluorescence) with an intensified charged-coupled device camera. Autofluorescence as Ph-a fluorescence images did not allow accurate LIF diagnosis of pancreatic carcinoma. An image processing, including for each pixel a computed division of Ph-a fluorescence (after subtraction of reddish autofluorescence) by bluish autofluorescence intensity generated poorly contrasted tumor images in five of six and false tumor localization in one of three of the tumor-bearing pancreas. A fitting of the digital 640 nm autofluorescence up to the mean 680 nm fluorescence intensity in pancreas prior to subtraction allowed a safe diagnosis to be made with well-contrasted tumor images. To assess automation ability of the processing, a same fitting coefficient (mean of individual values) was applied. In this way, false-negative (one of six) and false-positive (two of six) images were present in tumor-bearing animals as false-positive in one-half of the controls. A successful standardized procedure was then applied with a normalization of 640 and 680 nm pancreas intensities to a same set threshold prior processing. In opposition to thin-layered hollow organs, such as bronchial tube or digestive tract, LIF imaging of carcinoma inserted in a compact organ is exhausting. The use of a dye excitable in the red wavelength range (610 nm for Ph-a) may partly solve this problem, rendering LIF imaging more accurate and potentially automated.

Animals↗

Water-soluble quantum dots for multiphoton fluorescence imaging in vivo.

The use of semiconductor nanocrystals (quantum dots) as fluorescent labels for multiphoton microscopy enables multicolor imaging in demanding biological environments such as living tissue. We characterized water-soluble cadmium selenide-zinc sulfide quantum dots for multiphoton imaging in live animals. These fluorescent probes have two-photon action cross sections as high as 47,000 Goeppert-Mayer units, by far the largest of any label used in multiphoton microscopy. We visualized quantum dots dynamically through the skin of living mice, in capillaries hundreds of micrometers deep. We found no evidence of blinking (fluorescence intermittency) in solution on nanosecond to millisecond time scales.

Adipose Tissue↗